Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Infect Dis ; 24(1): 130, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38267905

RESUMO

BACKGROUND: Leprosy is a chronic infectious disease caused by Mycobacterium leprae, predominantly affecting the peripheral nerves, resulting in sensory and motor deficits in the feet. Foot ulcers and imbalances are frequent manifestations in leprosy, often correlating with diminished sensitivity. While clinical scales and monofilament esthesiometers are conventionally utilized to evaluate foot sensitivity and balance in these patients, their discriminatory power is limited and their effectiveness is greatly dependent on the examiner's proficiency. In contrast, baropodometry and posturography offer a more comprehensive evaluation, aiming to preempt potential damage events. This study aimed was to assess the correlation between baropodometry and force plate measurements in leprosy patients and control participants, to improve the prevention and treatment of foot ulcers and complications associated with leprosy. METHODOLOGY: This cross-sectional study was conducted during 2022 and enrolled 39 participants (22 patients with multibacillary leprosy and 17 non-leprosy controls). Demographic data were collected, and a monofilament esthesiometer was used to assess sensory deficits. In addition, physical examinations and balance and plantar pressure tests were conducted. The Student's t-test was used to compare mean and maximum plantar pressures between groups. For most COP variables, a Mann-Whitney Wilcoxon test was used, except for AP amplitude which was analyzed with the Student's t-test due to its normal distribution. The relationship between foot pressure and balance control was assessed using Spearman's correlation, focusing on areas with significant pressure differences between groups. PRINCIPAL FINDINGS: Leprosy patients showed increased pressure in forefoot areas (T1, M1, T2-T5, and M2) and decreased pressure in hindfoot regions (MH and LH) compared to controls. These patients also displayed higher AP and ML amplitudes, suggesting poorer COP control. Correlation analyses between the two groups revealed that foot plantar pressures significantly impact balance control. Specifically, increased T1 region pressures correlated with greater sway in balance tasks, while decreased MH region pressures were linked to reduced COP control. CONCLUSIONS/SIGNIFICANCE: The findings suggest a joint disturbance of plantar pressure distribution and static balance control in leprosy patients. These alterations may increase the risk of tissue injuries, including calluses and deformities, as well as falls.


Assuntos
Pé Diabético , Hanseníase Multibacilar , Humanos , Estudos Transversais , , Extremidade Inferior
2.
World J Surg Oncol ; 22(1): 71, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38419082

RESUMO

BACKGROUND: Objective assessment of pre-operative functional capacity in cancer patients using the smartphone gyroscope during the Chester step (CST) test may allow greater sensitivity of test results. This study has investigated whether the CST is a postoperative hospital permanence predictor in cancer patients undergoing abdominopelvic surgery through work, VO2MAX and gyroscopic movement analysis. METHODS: Prospective, quantitative, descriptive and inferential observational cohort study. Fifty-one patients were evaluated using CST in conjunction with a smartphone gyroscope. Multivariate linear regression analysis was used to examine the predictive value of the CST. RESULTS: The duration of hospital permanence 30 days after surgery was longer when patients who performed stage 1 showed lower RMS amplitude and higher peak power. The work increased as the test progressed in stage 3. High VO2MAX seemed to be a predictor of hospital permanence in those who completed levels 3 and 4 of the test. CONCLUSION: The use of the gyroscope was more accurate in detecting mobility changes, which predicted a less favorable result for those who met at level 1 of the CST. VO2MAX was a predictor of prolonged hospitalization from level 3 of the test. The work was less accurate to determine the patient's true functional capacity.


Assuntos
Teste de Esforço , Neoplasias , Humanos , Tempo de Internação , Teste de Esforço/métodos , Estudos Prospectivos , Smartphone , Análise Multivariada
3.
An Acad Bras Cienc ; 96(suppl 1): e20231244, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39082591

RESUMO

It was compared smartphone-based measurements of static balance control and mobility of elderly population with and without type 2 diabetes mellitus (DM2). The present cross-sectional study investigated 73 participants grouped in a control group (n = 36) and a DM2 group (n = 37). Smartphone's built in inertial sensors were used to record inertial changes of the participants during static balance and mobility (Timed Up and Go test - TUG) tasks. The inertial variations as a function of the time were analyzed and compared between groups. Both groups were matched in age, body mass index, male-female proportion, but DM2 group had significant larger fasting glucose than control group. Additionally, DM2 group had worst static balance control with open and closed eyes than the controls (p < 0.05) as well as they also had longer duration to execute the different events of the mobility test than the controls (p < 0.05). DM2 patients had decline of motor functions compared to controls and the use of bult-in sensors of smartphones was feasible to identify these functional impairments. The easy access of smartphones could be improving the screening of functional impairments in DM2 patients.


Assuntos
Diabetes Mellitus Tipo 2 , Equilíbrio Postural , Smartphone , Humanos , Diabetes Mellitus Tipo 2/fisiopatologia , Masculino , Feminino , Estudos Transversais , Equilíbrio Postural/fisiologia , Idoso , Pessoa de Meia-Idade , Estudos de Casos e Controles
4.
Sensors (Basel) ; 24(14)2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39066013

RESUMO

During pregnancy, biomechanical changes are observed due to hormonal and physical modifications, which can lead to alterations in the curvature of the spine, balance, gait patterns, and functionality of the pelvic floor muscles. This study aimed to investigate the progressive impact of biomechanical changes that occur during gestational weeks on the myoelectric activity of the pelvic floor muscles, plantar contact area, and functional mobility of high-risk pregnant women. METHODS: This was a cross-sectional observational study carried out from November 2022 to March 2023. A total of 62 pregnant women of different gestational ages with high-risk pregnancies were analyzed using surface electromyography to assess the functionality of the pelvic floor muscles, plantigraphy (Staheli index and plantar contact area), and an accelerometer and gyroscope using the timed up and go test via an inertial sensor on a smartphone. Descriptive statistics and multivariate linear regression analyses were carried out to test the predictive value of the signature. RESULTS: Increasing weeks of gestation resulted in a decrease in the RMS value (ß = -0.306; t = -2.284; p = 0.026) according to the surface electromyography analyses. However, there was no association with plantar contact (F (4.50) = 0.697; p = 0.598; R2 = 0.53). With regard to functional mobility, increasing weeks of gestation resulted in a decrease in time to standing (ß = -0.613; t = -2.495; p = 0.016), time to go (ß = -0.513; t = -2.264; p = 0.028), and first gyrus peak (ß = -0.290; t = -2.168; p = 0.035). However, there was an increase in the time to come back (ß = 0.453; t = 2.321; p = 0.025) as the number of gestational weeks increased. CONCLUSIONS: Increased gestational age is associated with a reduction in pelvic floor myoelectric activity. The plantar contact area did not change over the weeks. Advancing gestation was accompanied by a decrease in time to standing, time to go, and first gyrus peak, as well as an increase in time to come back.


Assuntos
Eletromiografia , Idade Gestacional , Diafragma da Pelve , Humanos , Feminino , Gravidez , Diafragma da Pelve/fisiologia , Estudos Transversais , Eletromiografia/métodos , Adulto , Músculo Esquelético/fisiologia , Músculo Esquelético/fisiopatologia , Marcha/fisiologia , Fenômenos Biomecânicos/fisiologia , Acelerometria/métodos
5.
Sensors (Basel) ; 24(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38733024

RESUMO

The Timed-Up and Go (TUG) test is widely utilized by healthcare professionals for assessing fall risk and mobility due to its practicality. Currently, test results are based solely on execution time, but integrating technological devices into the test can provide additional information to enhance result accuracy. This study aimed to assess the reliability of smartphone-based instrumented TUG (iTUG) parameters. We conducted evaluations of intra- and inter-device reliabilities, hypothesizing that iTUG parameters would be replicable across all experiments. A total of 30 individuals participated in Experiment A to assess intra-device reliability, while Experiment B involved 15 individuals to evaluate inter-device reliability. The smartphone was securely attached to participants' bodies at the lumbar spine level between the L3 and L5 vertebrae. In Experiment A, subjects performed the TUG test three times using the same device, with a 5 min interval between each trial. Experiment B required participants to perform three trials using different devices, with the same time interval between trials. Comparing stopwatch and smartphone measurements in Experiment A, no significant differences in test duration were found between the two devices. A perfect correlation and Bland-Altman analysis indicated good agreement between devices. Intra-device reliability analysis in Experiment A revealed significant reliability in nine out of eleven variables, with four variables showing excellent reliability and five showing moderate to high reliability. In Experiment B, inter-device reliability was observed among different smartphone devices, with nine out of eleven variables demonstrating significant reliability. Notable differences were found in angular velocity peak at the first and second turns between specific devices, emphasizing the importance of considering device variations in inertial measurements. Hence, smartphone inertial sensors present a valid, applicable, and feasible alternative for TUG assessment.


Assuntos
Smartphone , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Reprodutibilidade dos Testes , Acidentes por Quedas/prevenção & controle
6.
Sensors (Basel) ; 22(21)2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36365967

RESUMO

INTRODUCTION: Evidence supports the importance of efficient postural control to improve performance in sports. This involves the use of strategies such as anticipatory posture adjustments and compensatory adjustments. Technology makes analysis and assessments in sports cheaper, while being valid and reliable compared to the gold-standard assessment equipment. OBJECTIVES: This article aimed to test the validity and reliability of signals extracted from the sensor's accelerometer (Metamotion C), by comparing it to the data obtained from the gold-standard equipment (a three-dimensional video-motion-capture system). DESIGN: Observational, cross-sectional study. METHODS: We exposed 20 healthy young standing people to the pendulum impact paradigm, which consisted of predictable anteroposterior disturbances applied at the shoulder level. In order to measure this, we observed the acceleration of the center of mass in the anticipatory and compensatory phase of the disturbance and compared the signals of the two devices (Metamotion C and a motion-capture system). RESULTS: The validation results showed the significant linear correlation of all variables with a moderate to large correlation of r ≥ 0.5 between the devices. In contrast, the reliability results between sessions obtained by filming were all significant and above 0.75, indicating excellent reliability. The APAonset variable had a reasonable to high intra-class correlation in the anticipatory phase. In the compensatory phase, the CPAtime variable showed an excellent correlation. CONCLUSIONS: Metamotion C proved reasonably valid and highly reliable in measuring the center of mass acceleration compared to the camera system in both the anticipatory and compensatory phases.


Assuntos
Equilíbrio Postural , Dispositivos Eletrônicos Vestíveis , Humanos , Reprodutibilidade dos Testes , Estudos Transversais , Postura
7.
Sensors (Basel) ; 22(8)2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35458920

RESUMO

The evaluation of anticipatory postural adjustments (APAs) requires high-cost and complex handling systems, only available at research laboratories. New alternative methods are being developed in this field, on the other hand, to solve this issue and allow applicability in clinic, sport and hospital environments. The objective of this study was to validate an app for mobile devices to measure the APAs during gait initiation by comparing the signals obtained from cell phones using the Momentum app with measurements made by a kinematic system. The center-of-mass accelerations of a total of 20 healthy subjects were measured by the above app, which read the inertial sensors of the smartphones, and by kinematics, with a reflective marker positioned on their lumbar spine. The subjects took a step forward after hearing a command from an experimenter. The variables of the anticipatory phase, prior to the heel-off and the step phase, were measured. In the anticipatory phase, the linear correlation of all variables measured by the two measurement techniques was significant and indicated a high correlation between the devices (APAonset: r = 0.95, p < 0.0001; APAamp: r = 0.71, p = 0.003, and PEAKtime: r = 0.95, p < 0.0001). The linear correlation between the two measurement techniques for the step phase variables measured by ques was also significant (STEPinterval: r = 0.56, p = 0.008; STEPpeak1: r = 0.79, p < 0.0001; and STEPpeak2: r = 0.64, p < 0.0001). The Bland−Altman graphs indicated agreement between instruments with similar behavior as well as subjects within confidence limits and low dispersion. Thus, using the Momentum cell phone application is valid for the assessment of APAs during gait initiation compared to the gold standard instrument (kinematics), proving to be a useful, less complex, and less costly alternative for the assessment of healthy individuals.


Assuntos
Transtornos Neurológicos da Marcha , Aplicativos Móveis , Marcha , Humanos , Equilíbrio Postural , Reprodutibilidade dos Testes , Smartphone
8.
Hong Kong Physiother J ; 41(2): 77-87, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34177196

RESUMO

OBJECTIVES: (1) To assess the effects of a conventional, delayed physiotherapy protocol used by Ischemic Stroke (IS) and Hemorrhagic Stroke (HS) post-stroke patients, in their electromyographic activation patterns during hemiparetic gait; and (2) to study whether this protocol may improve the functional abilities in this population. METHODS: This is an observational, descriptive, and analytical quasi-experimental trial. Forty patients with unilateral IS ( n = 25 ) and HS ( n = 15 ) stroke were recruited; the stroke involved the motor cortex or sub-cortical areas, and the patients were able to walk independently. Interventions with standard protocols of physiotherapy were carried out. Evaluations (clinical and gait assessment) were performed at the time of admission and at the end of the protocol. Outcome measures include Stroke Impact Scale, Timed Up and Go Test, and gait electromyographic evaluation. RESULTS: Only IS patients (with an average of 124 . 4 ± 45 . 4 months delayed access to physiotherapy rehabilitation) had improvements in Timed Up and Go Test (change in speed =- 8 . 0 seg p < 0 . 05 ) and presented an anticipation of the onset in Upper leg muscles after the intervention. BF ( p = 0 . 05 ), ST ( p = 0 . 001 ), and RF ( p = 0 . 024 ), started their recruitment (onset) earlier at the swing phase of the gait cycle, which is more similar to the normal pattern (grey shadow). IS and HS ( 120 . 4 ± 28 . 4 months since last stroke) patients presented higher electromyographic activation, after physiotherapy, of the posterior leg muscles (gastrocnemius, semitendinosus and biceps femoris) during stance phase ( p < 0 . 05 ). CONCLUSION: IS patients had improvements after delayed conventional physiotherapy. For HS limited response to intervention was observed.

9.
J Hand Ther ; 31(1): 42-51, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28236562

RESUMO

STUDY DESIGN: Case series (longitudinal). INTRODUCTION: Only few reports concerning the efficacy of commonly used strategies for preventing upper limb occupational disorders associated with prolonged typing exist. PURPOSE OF THE STUDY: We aimed to investigate whether the duration of typing and the use of 2 strategies (hand rest and wrist support) changes muscle physiological response and therefore the electromyography records. METHODS: We enrolled 25 volunteers, who were unfamiliar with the task and did not have musculoskeletal disorders. The subjects underwent 3 prolonged typing protocols to investigate the efficacy of the 2 adopted strategies in reducing the trapezius, biceps brachii, and extensor digitorum communis fatigue. RESULTS: Typing for 1 hour induced muscular fatigue (60%-67% of the subjects). The extensor digitorum communis muscle exhibited the highest percentage of fatigue (72%-84%) after 1 and 4 hours of typing (1 hour, P = .04; 4 hours, P = .02). Fatigue levels in this muscle were significantly reduced (24%) with the use of pause typing (4 hours, P = .045), whereas biceps brachii muscle fatigue was reduced (32%) only with the use of wrist supports (P = .02, after 4 hours). Trapezius muscle fatigue was unaffected by the tested occupational strategies (1 hour, P = .62; 4 hours, P = .85). DISCUSSION: Despite presenting an overall tendency for fatigue detected during the application of the protocols, the assessed muscles exhibited different behavior patterns, depending on both the preventive strategy applied and the muscle mechanical role during the task. CONCLUSION: Hand rest and wrist support can successfully reduce muscle fatigue in specific upper limb muscles during prolonged typing, leading to a muscle-selective reduction in the occurrence of fatigue and thus provide direct evidence that they may prevent work-related musculoskeletal disorders. LEVEL OF EVIDENCE: N/A.


Assuntos
Mãos , Fadiga Muscular , Doenças Musculoesqueléticas/prevenção & controle , Doenças Profissionais/prevenção & controle , Aparelhos Ortopédicos , Descanso , Adulto , Eletromiografia , Feminino , Humanos , Estudos Longitudinais , Músculo Esquelético/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
10.
J Manipulative Physiol Ther ; 41(4): 323-331, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29751850

RESUMO

OBJECTIVE: The purpose of this study was to compare transcutaneous electrical nerve stimulation (TENS) and stabilization exercises in an attempt to prevent fatigue and improve muscle activation in patients with lumbar disk herniation associated with low back pain. METHODS: This study involved 29 patients (age range 25-58 years) randomized into 2 groups: the segmental stabilization group (n = 15), who received stabilization exercises on the transversus abdominis (TrA) and lumbar multifidus muscles; and the TENS group (n = 14), who received electrotherapy. Groups underwent 16 sessions, for 60 minutes, twice per week, and they were evaluated before and after intervention. Pain was measured using a visual analog scale, functional disability using the Oswestry Disability Index, muscle activation and fatigue with electromyography, and patients' ability to contract the TrA with a pressure biofeedback unit. Analyses within and between groups were performed. RESULTS: The stabilization group improved lumbar multifidus fatigue (median frequency [MF] initial [P = .002], MF final [P < .001], MF slope [P = .001], and resistance time [P < .001]), ability to contract the TrA (P < .001), pain (P < .001), and functional disability (P < .001). TENS only was effective for pain (P = .012). CONCLUSION: Although it relieved pain, TENS was not effective as a single treatment to prevent fatigue, increase TrA contraction, and reduce functional disability in herniated disk patients. Stabilization exercises alone improved all measured outcomes.


Assuntos
Terapia por Exercício/métodos , Degeneração do Disco Intervertebral/terapia , Deslocamento do Disco Intervertebral/terapia , Região Lombossacral/fisiopatologia , Estimulação Elétrica Nervosa Transcutânea/métodos , Músculos Abdominais/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fadiga Muscular , Músculos Paraespinais/fisiopatologia
11.
J Sport Rehabil ; 26(1): 65-71, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27632837

RESUMO

CONTEXT: Pelvic-drop exercises are often used to strengthen the gluteus medius (GM) muscle with the aim of increasing or prioritizing its recruitment. However, the effect of hip rotation on the performance of the action of the GM is unknown. OBJECTIVE: To evaluate the effect of hip rotation on the recruitment of the GM, tensor fasciae latae (TFL), and quadratus lumborum (QL). METHOD: Seventeen healthy subjects performed 2 sets of 4 repetitions of pelvic-drop exercise in random order with pelvic-drop lateral, medial, and neutral rotation of the hip. MAIN OUTCOME MEASURES: The electromyographic (EMG) activity of the GM, TFL, and QL was evaluated using surface electromyography. RESULTS: There were significant increases in the activation of the GM with medial and neutral rotation compared with lateral rotation (P = .03, P = .01, respectively), and there was no difference between medial and neutral rotation (P = 1.00). There was no difference in EMG activity of the TFL and QL in any of the positions. The GM:TFL ratio was the same in all analyzed positions. Regarding the GM:QL ratio, there was a significant increase with medial rotation compared with lateral rotation (P = .02). CONCLUSIONS: Pelvic-drop exercises are more efficient for activating the GM when the hip is in medial rotation and neutral position.


Assuntos
Eletromiografia , Teste de Esforço/métodos , Quadril/fisiologia , Músculo Esquelético/fisiologia , Rotação , Adulto , Nádegas/fisiologia , Feminino , Humanos , Adulto Jovem
12.
Eur Spine J ; 25(5): 1435-1442, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26769037

RESUMO

PURPOSE: The aims of this study were to assess lumbar multifidus fatigue (LM) and transversus abdominis activation (TrA) in individuals with lumbar disc herniation associated with low back pain. METHODS: Sixty individuals were divided into the lumbar herniation (LHG, n = 30) and control groups (CG, n = 30). Fatigue of the LM was assessed using surface electromyography during the Sorensen effort test, and activation of the TrA with a pressure biofeedback unit. Pain intensity was determined using a visual analog scale and the McGill pain questionnaire. The Oswestry disability questionnaire and the Borg scale for self-evaluating exertion were used to assess functional disability. RESULTS: Fatigue was significantly more intense and the TrA activation was insufficient (p < 0.01) in individuals with disc herniation relative to the control group. The LHG had mild functional disability and moderate pain. There were differences in the initial exertion self-evaluation between groups, which were not observed in the final exertion evaluation. CONCLUSION: Individuals with lumbar disc herniation associated with low back pain have increased fatigue of the LM and decreased activation of the TrA, when compared to the control group.


Assuntos
Músculos Abdominais/fisiologia , Deslocamento do Disco Intervertebral , Dor Lombar , Região Lombossacral/fisiopatologia , Músculos Paraespinais/fisiopatologia , Adulto , Estudos de Casos e Controles , Humanos , Deslocamento do Disco Intervertebral/epidemiologia , Deslocamento do Disco Intervertebral/fisiopatologia , Dor Lombar/epidemiologia , Dor Lombar/fisiopatologia , Pessoa de Meia-Idade , Fadiga Muscular , Adulto Jovem
13.
PLoS One ; 19(5): e0302542, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38743710

RESUMO

To evaluate the effectiveness of a home exercise program called Home Exercise Booklet for People Living with Human T Lymphotropic Virus 1 (HTLV-1). This is a methodological study of content validation with expert judges. A questionnaire with a Likert scale was applied, containing 16 items referring to the content domain. Descriptive statistics were used to obtain the content validity index. In total, 46 judges participated, 24 physiotherapists (PG) and 22 professionals from other health areas specializing in methodological studies and HTLV-1 (EG). In the validation process, each evaluator judged the technology and scored their considerations. In the end, we obtained the following results for the Content Validity Index (CVI): PG CVI: 94.3%, GE CVI: 93.4%. Although the index was sufficient to consider the technology validated, modifications were made to the second and final version of the booklet, considering the judges' observations and suggestions, which we consider relevant. The technology proved to be valid for use with the target audience. The development and validation of this product provides support to help prevent functional decline in people living with HTLV-1; standardize guidelines for physiotherapy professionals who monitor these issues; start a home exercise program aimed at other comorbidities; open the possibility of creating and validating home exercise programs with other comorbidities.


Assuntos
Terapia por Exercício , Vírus Linfotrópico T Tipo 1 Humano , Humanos , Terapia por Exercício/métodos , Inquéritos e Questionários , Feminino , Infecções por HTLV-I/prevenção & controle , Masculino , Adulto , Pessoas com Deficiência/reabilitação , Pessoa de Meia-Idade , Exercício Físico
14.
Front Digit Health ; 6: 1345562, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38835672

RESUMO

Several protocols for motor assessment have been validated for use on smartphones and could be employed by public healthcare systems to monitor motor functional losses in populations, particularly those with lower income levels. In addition to being cost-effective and widely distributed across populations of varying income levels, the use of smartphones in motor assessment offers a range of advantages that could be leveraged by governments, especially in developing and poorer countries. Some topics related to potential interventions should be considered by healthcare managers before initiating the implementation of such a digital intervention.

15.
Games Health J ; 13(2): 100-108, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38436585

RESUMO

Background: Virtual reality (VR) has been suggested as a new therapeutic approach in various sectors of rehabilitation, including the treatment of patients with knee osteoarthritis (OA), and one of its treatment goals is to improve the gait pattern and walking ability of patients. Objective: This study aimed to evaluate if VR, along with conventional physiotherapy treatment (CT), has superior effects to kinesiotherapy alone on pain, physical capacity, balance, and the parameters of anticipatory postural adjustments (APAs) in patients with knee OA. Design: This study is a single-blind randomized controlled trial. Setting: Secondary care at Hospital SARAH Network of Rehabilitation Hospitals, Brazil. Participants: Forty participants (31 women and 9 men) with knee OA in at least one knee and able to ambulate independently. Intervention: A rehabilitation program (8 consecutive weeks, 50-minute session, twice a week). Patients were randomized into the intervention groups CT or VR. Main Outcome Measures: Primary-latency of APA, amplitude of APA, and time to reach the maximum acceleration amplitude. Secondary-balance control by Mini-Balance Evaluation Systems Test, pain, and physical capacity by Western Ontario and McMaster Universities Arthritis Index. Results: The results of the study showed that conventional treatment significantly improved pain intensity, physical capacity, and balance in individuals with knee OA; however, only the group that used VR showed improvement in the APA parameters. Conclusion: This study demonstrated that VR associated with conventional treatment improved APAs in patients with knee OA.


Assuntos
Osteoartrite do Joelho , Masculino , Humanos , Feminino , Osteoartrite do Joelho/reabilitação , Método Simples-Cego , Equilíbrio Postural , Articulação do Joelho , Dor , Resultado do Tratamento
16.
Sci Rep ; 14(1): 17409, 2024 07 29.
Artigo em Inglês | MEDLINE | ID: mdl-39075219

RESUMO

Anticipatory postural adjustments (APAs) involve a complex coordination of sensorimotor information that can be impaired in diseases that affect nerve conduction. Assessing APAs typically requires costly video recording technology, posing a challenge to the study of postural changes. This hurdle is compounded in impoverished communities affected by diseases such as leprosy, which often receive limited government support. Recent years have seen the validation of inertial sensors in wearable devices and smartphones for APA analysis in diverse populations, including adults, the elderly and people with Parkinson's disease. This progress offers economically efficient alternatives for the study of APA in leprosy. Do patterns of activation of anticipatory postural adjustment differ between leprosy patients and healthy controls? We also investigated the validity and replicability of APAs recorded in leprosy patients using inertial measurements and video capture recordings. Thirty healthy individuals in the control group and 30 individuals with leprosy in the leprosy group performed ten gait initiation trials. To record the APA for gait initiation, the participants stood on a 2 m platform. Each participant was informed that the experimenter would give an signal, after which the participant would initiate a two-step walk on the platform. Inertial recordings (low-cost method) and video capture recordings (gold-standard method) from center of mass displacements were used to extract the APA before gait initiation. The results show that APAs are similar between groups (control and leprosy), but leprosy patients have less consistent APAs. In addition, this study highlights the reproducibility and high correlation between the values of variables obtained from both instruments, the video recording as gold standard method and portable digital inertial sensor as a low-cost alternative method. These promising findings support the use of affordable inertial sensors to track and record APAs in underserved populations that lack easy access to gold standard methods such as video recording. This approach has the potential to improve the therapeutic care and rehabilitation of these patients. Although not currently part of official protocols for leprosy patients, this assessment method could prove particularly valuable in situations where significant sensorimotor impairments are suspected or documented.


Assuntos
Acelerometria , Hanseníase , Humanos , Hanseníase/fisiopatologia , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Acelerometria/instrumentação , Acelerometria/métodos , Equilíbrio Postural/fisiologia , Marcha/fisiologia , Estudos de Casos e Controles , Dispositivos Eletrônicos Vestíveis , Idoso , Caminhada/fisiologia
17.
PLoS One ; 19(3): e0291588, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38536803

RESUMO

The pelvic floor requires an integrated anatomical structure owing to its multiple functions. Therefore, it is necessary to study methods for improving muscle recruitment during training. This study aimed to analyze the effect of using an innovative vaginal trainer on the bioelectrical activity of the pelvic floor muscles. Pelvic positioning and interference factors, such as age, childbirth, sexual activity, urinary incontinence, and menopause, were also analyzed. A cross-sectional study assessed 30 women using an evaluation form, International Consultation on Incontinence Questionnaire-Short Form, and surface electromyography. The root mean square of a 5-second contraction period, peak root mean square values, area values, % maximal voluntary contraction (root mean square normalized by peak signal), and median frequency were collected. These findings with and without the use of a vaginal educator were compared in the anteversion, neutral, and retroversion pelvic positions. The use of a vaginal educator was found to increase the electromyographic activity of the pelvic floor muscles in the neutral position. In this position, older women showed an increased peak contraction when using the educator. Multiparas also benefited from increased bioelectric activity (root mean square and area). Sexually active women increased their bioelectric activity in a neutral position when using the trainer, exerting less effort in retroversion (%-maximal voluntary contraction). Incontinent and menopausal women exhibited slower body-building activation (decreased frequency) with the device, which requires further investigation. Our innovative biofeedback device induced greater recruitment of muscle fibers, is more effective in the neutral pelvic position, and may be effective in training the pelvic floor muscles, even in women with a greater tendency toward pelvic floor dysfunction.


Assuntos
Diafragma da Pelve , Incontinência Urinária , Feminino , Humanos , Idoso , Estudos Transversais , Contração Muscular/fisiologia , Eletromiografia/métodos
18.
BMC Infect Dis ; 13: 119, 2013 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-23510379

RESUMO

BACKGROUND: Ventilator-associated pneumonia (VAP) is considered the most common nosocomial infection in the intensive care unit (ICU), but its features are not fully known in many hospitals in Brazil. We identified clinical and epidemiological aspects associated with VAP in an intensive care unit (ICU) in a general public hospital in northern Brazil and performed an analytical descriptive prospective cohort study. METHODS: We analyzed data from thirty-three patients who developed VAP while in the ICU. Clinical and epidemiological data of patients were obtained and tracheal secretions were submitted to culture. Microbial isolates were identified and evaluated for resistance against antimicrobial agents by using the automated Vitek 2 system. RESULTS: The frequency of VAP was 26.2% in patients submitted to invasive mechanical ventilation for at least 48 hours, and death occurred in 78.8% of cases. Only the presence of comorbidity showed a significant association (P = 0.029) with death. The most commonly found bacteria were Pseudomonas aeruginosa, Acinetobacter spp., and Enterobacteriaceae. We also found a frequency of 54.5% of multiresistant bacteria associated with VAP, and previous antibiotic therapy was used in 97% of patients. CONCLUSIONS: VAP in our ICU presented with a high frequency and was mainly caused by multiresistant bacteria. Implementation of rational protocols for the use of antibacterial agents and rapid delivery of culture and susceptibility test results are essential. This may help decrease VAP-related mortality rates by multiresistant bacteria in the ICU.


Assuntos
Pneumonia Associada à Ventilação Mecânica/epidemiologia , Adulto , Idoso , Antibacterianos/uso terapêutico , Brasil/epidemiologia , Farmacorresistência Bacteriana Múltipla , Feminino , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Negativas/isolamento & purificação , Infecções por Bactérias Gram-Negativas , Humanos , Unidades de Terapia Intensiva , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Pneumonia Associada à Ventilação Mecânica/tratamento farmacológico , Pneumonia Associada à Ventilação Mecânica/microbiologia , Pneumonia Associada à Ventilação Mecânica/mortalidade , Estudos Prospectivos , Estatísticas não Paramétricas , Resultado do Tratamento
19.
Infect Dis Rep ; 15(5): 478-493, 2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37736995

RESUMO

To achieve the objective of this study, we conducted a narrative review on physical therapeutic modalities applied to prevent functional losses associated with human T-lymphotropic virus 1 (HTLV-1) infections to promote health education and viable and accessible alternatives in the development of health education technology adapted to the home environment. This study comprised a qualitative stage of theoretical development to construct a digital booklet with an observational basis based on studies that reiterate themes about educational technologies as tools to conduct a home protocol of guided exercises without the direct supervision of professional physical therapists. Results indicate a lack of research on the development of health education technologies to assist patients with HTLV-1 without tropical spastic paraparesis or HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM/TSP). We believe that this narrative review can initiate a theoretical framework to conduct a home exercise program aimed at people with HTLV-1 who have subtle symptoms, and also at people without the clinical definition of HAM/TSP, helping to train human resources for care and research on the subject and increase scientific production in physical therapy.

20.
PLoS One ; 18(8): e0289588, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37561689

RESUMO

Older adults with moderate to severe knee osteoarthritis (KOA) exhibit adaptive strategy for initiating walking, known as anticipatory postural adjustments (APAs). While video motion kinematics has been the traditional way of measuring APAs, it can be difficult to transport and install, making it impractical for medical settings. Inertial sensors have become a more popular method for evaluating APAs, but no prior research has used accelerometers to measure gait initiation in individuals with KOA. The study aimed to assess the validity and reliability of a wearable accelerometer device for measuring APAs older adults with and without KOA. 25 individuals with KOA and 10 healthy individuals underwent evaluation using a wearable commercially available accelerometer (MetamotionC) and a video motion capture system. Reflective markers were placed on the lumbar vertebra and calcaneus. Participants were asked to initiate a step, and the researchers measured the APAlatency and APAamplitude of each subject. APAlatency showed an very large to almost perfect correlation in both groups (CG:r = 0.82; p = 0.003 and KOA r = 0.98; p < 0.00001) between the instruments, while APAamplitude had a moderate to very large correlation (CG: r = 0.65; p = 0.04and KOA: r = 0.80; p < 0.00001). Overall, the measurements showed fair to high reliability for intraclass correlation for video and accelerometer variables. Significant group effect was found for both variables: APAlatency (F1, 66 = 7.3; p = 0.008) and APAamplitude (F1,66 = 9.5; p = 0.00). The wearable tri-axial accelerometer is a valid and reliable for assessing APAs during gait initiation in individuals with KOA, and this population exhibits lower APAs when initiating a step.


Assuntos
Osteoartrite do Joelho , Humanos , Idoso , Reprodutibilidade dos Testes , Equilíbrio Postural , Marcha , Caminhada , Fenômenos Biomecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA