Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Phys Rev Lett ; 131(19): 197001, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38000439

RESUMO

The spin-orbit interaction in spin qubits enables spin-flip transitions, resulting in Rabi oscillations when an external microwave field is resonant with the qubit frequency. Here, we introduce an alternative driving mechanism mediated by the strong spin-orbit interactions in hole spin qubits, where a far-detuned oscillating field couples to the qubit phase. Phase-driving at radio frequencies, orders of magnitude slower than the microwave qubit frequency, induces highly nontrivial spin dynamics, violating the Rabi resonance condition. By using a qubit integrated in a silicon fin field-effect transistor, we demonstrate a controllable suppression of resonant Rabi oscillations and their revivals at tunable sidebands. These sidebands enable alternative qubit control schemes using global fields and local far-detuned pulses, facilitating the design of dense large-scale qubit architectures with local qubit addressability. Phase-driving also decouples Rabi oscillations from noise, an effect due to a gapped Floquet spectrum and can enable Floquet engineering high-fidelity gates in future quantum processors.

2.
Phys Rev Lett ; 127(5): 057701, 2021 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34397233

RESUMO

We experimentally determine isotropic and anisotropic g-factor corrections in lateral GaAs single-electron quantum dots. We extract the Zeeman splitting by measuring the tunnel rates into the individual spin states of an empty quantum dot for an in-plane magnetic field with various strengths and directions. We quantify the Zeeman energy and find a linear dependence on the magnetic field strength that allows us to extract the g factor. The measured g factor is understood in terms of spin-orbit interaction induced isotropic and anisotropic corrections to the GaAs bulk g factor. Experimental detection and identification of minute band-structure effects in the g factor is of significance for spin qubits in GaAs quantum dots.

3.
Phys Rev Lett ; 122(20): 207701, 2019 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-31172765

RESUMO

We show that in-plane magnetic-field-assisted spectroscopy allows extraction of the in-plane orientation and full 3D size parameters of the quantum mechanical orbitals of a single electron GaAs lateral quantum dot with subnanometer precision. The method is based on measuring the orbital energies in a magnetic field with various strengths and orientations in the plane of the 2D electron gas. From such data, we deduce the microscopic confinement potential landscape and quantify the degree by which it differs from a harmonic oscillator potential. The spectroscopy is used to validate shape manipulation with gate voltages, agreeing with expectations from the gate layout. Our measurements demonstrate a versatile tool for quantum dots with one dominant axis of strong confinement.

4.
Exp Eye Res ; 116: 298-307, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24095823

RESUMO

The current study investigates the structural and compositional changes of ocular basement membranes (BMs) during long-term diabetes. By comparing retinal vascular BMs and the inner limiting membrane (ILM) from diabetic and non-diabetic human eyes by light and transmission electron microscopy (TEM), a massive, diabetes-related increase in the thickness of these BMs was detected. The increase in ILM thickness was confirmed by atomic force microscopy (AFM) on native ILM flat-mount preparations. AFM also detected a diabetes-induced increase in ILM stiffness. The changes in BM morphology and biophysical properties were accompanied by partial changes in the biochemical composition as shown by immunocytochemistry and western blots: agrin, fibronectin and tenascin underwent relative increases in concentration in diabetic BMs as compared to non-diabetic BMs. Fibronectin and tenascin were particularly high in the BMs of outlining microvascular aneurisms. The present data showed that retinal vascular BMs and the ILM undergo morphological, biomechanical and compositional changes during long-term diabetes. The increase in BM thickness not only resulted from an up-regulation of the standard BM proteins, but also from the expression of diabetes-specific extracellular matrix proteins that are not normally found in retinal BMs.


Assuntos
Membrana Basal/química , Retinopatia Diabética/metabolismo , Proteínas da Matriz Extracelular/análise , Retina/química , Adulto , Idoso , Idoso de 80 Anos ou mais , Membrana Basal/ultraestrutura , Western Blotting , Retinopatia Diabética/patologia , Retinopatia Diabética/fisiopatologia , Elasticidade , Feminino , Humanos , Masculino , Microscopia de Força Atômica , Microscopia Eletrônica de Transmissão , Pessoa de Meia-Idade , Retina/ultraestrutura
5.
Nat Nanotechnol ; 16(3): 308-312, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33432204

RESUMO

Quantum computers promise to execute complex tasks exponentially faster than any possible classical computer, and thus spur breakthroughs in quantum chemistry, material science and machine learning. However, quantum computers require fast and selective control of large numbers of individual qubits while maintaining coherence. Qubits based on hole spins in one-dimensional germanium/silicon nanostructures are predicted to experience an exceptionally strong yet electrically tunable spin-orbit interaction, which allows us to optimize qubit performance by switching between distinct modes of ultrafast manipulation, long coherence and individual addressability. Here we used millivolt gate voltage changes to tune the Rabi frequency of a hole spin qubit in a germanium/silicon nanowire from 31 to 219 MHz, its driven coherence time between 7 and 59 ns, and its Landé g-factor from 0.83 to 1.27. We thus demonstrated spin-orbit switch functionality, with on/off ratios of roughly seven, which could be further increased through improved gate design. Finally, we used this control to optimize our qubit further and approach the strong driving regime, with spin-flipping times as short as ~1 ns.

6.
Nat Commun ; 9(1): 3454, 2018 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-30150721

RESUMO

Understanding and control of the spin relaxation time T1 is among the key challenges for spin-based qubits. A larger T1 is generally favored, setting the fundamental upper limit to the qubit coherence and spin readout fidelity. In GaAs quantum dots at low temperatures and high in-plane magnetic fields B, the spin relaxation relies on phonon emission and spin-orbit coupling. The characteristic dependence T1 ∝ B-5 and pronounced B-field anisotropy were already confirmed experimentally. However, it has also been predicted 15 years ago that at low enough fields, the spin-orbit interaction is replaced by the coupling to the nuclear spins, where the relaxation becomes isotropic, and the scaling changes to T1 ∝ B-3. Here, we establish these predictions experimentally, by measuring T1 over an unprecedented range of magnetic fields-made possible by lower temperature-and report a maximum T1 = 57 ± 15 s at the lowest fields, setting a record electron spin lifetime in a nanostructure.

7.
Invest Ophthalmol Vis Sci ; 57(6): 2839-49, 2016 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-27233032

RESUMO

PURPOSE: Cataract surgery requires the removal of a circular segment of the anterior lens capsule (LC) by manual or femtosecond laser (FL) capsulotomy. Tears in the remaining anterior LC may compromise surgical outcome. We investigated whether biophysical differences in the rim properties of the LC remaining in the patient after manual or FL capsulotomy (FLC) lead to different risks with regard to anterior tear formation. METHODS: Lens capsule samples obtained by either continuous curvilinear capsulorhexis (CCC) or FLC were investigated by light microscopy, laser scanning confocal microscopy, and scanning electron microscopy; atomic force microscopy (AFM) was used to test the biomechanical properties of the LC. The mechanical stability of the LC following either of the two capsulotomy techniques was simulated by using finite-element modeling. RESULTS: Continuous curvilinear capsulorhexis produced wedge-shaped, uniform rims, while FLC resulted in nearly perpendicular, frayed rims with numerous notches. The LC is composed of two sublayers: a stiff epithelial layer that is abundant with laminin and a softer anterior chamber layer that is predominantly made from collagen IV. Computer models show that stress is uniformly distributed over the entire rim after CCC, while focal high stress concentrations are observed in the frayed profiles of LC after FLC, making the latter procedure more prone to anterior tear formation. CONCLUSIONS: Finite-element modeling based on three-dimensional AFM maps indicated that CCC leads to a capsulotomy rim with higher stress resistance, leading to a lower propensity for anterior radial tears than FLC.


Assuntos
Cápsula Anterior do Cristalino/ultraestrutura , Capsulorrexe/métodos , Terapia a Laser/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cápsula Anterior do Cristalino/fisiopatologia , Cápsula Anterior do Cristalino/cirurgia , Fenômenos Biomecânicos , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Microscopia de Força Atômica , Microscopia Confocal , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Adulto Jovem
9.
FEBS J ; 282(23): 4466-79, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26299746

RESUMO

Basement membranes (BMs) are thin sheets of extracellular matrix that outline epithelia, muscle fibers, blood vessels and peripheral nerves. The current view of BM structure and functions is based mainly on transmission electron microscopy imaging, in vitro protein binding assays, and phenotype analysis of human patients, mutant mice and invertebrata. Recently, MS-based protein analysis, biomechanical testing and cell adhesion assays with in vivo derived BMs have led to new and unexpected insights. Proteomic analysis combined with ultrastructural studies showed that many BMs undergo compositional and structural changes with advancing age. Atomic force microscopy measurements in combination with phenotype analysis have revealed an altered mechanical stiffness that correlates with specific BM pathologies in mutant mice and human patients. Atomic force microscopy-based height measurements strongly suggest that BMs are more than two-fold thicker than previously estimated, providing greater freedom for modelling the large protein polymers within BMs. In addition, data gathered using BMs extracted from mutant mice showed that laminin has a crucial role in BM stability. Finally, recent evidence demonstrate that BMs are bi-functionally organized, leading to the proposition that BM-sidedness contributes to the alternating epithelial and stromal tissue arrangements that are found in all metazoan species. We propose that BMs are ancient structures with tissue-organizing functions and were essential in the evolution of metazoan species.


Assuntos
Membrana Basal/química , Membrana Basal/metabolismo , Animais , Membrana Basal/ultraestrutura , Humanos , Microscopia de Força Atômica , Proteômica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA