1.
Rev Sci Instrum ; 82(5): 053501, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21639498

RESUMO

Deconvolution of Thomson scattering (TS) profiles is required when the gradient length of the electron temperature (T(e)) or density (n(e)) are comparable to the instrument function length (Δ(R)). The most correct method for deconvolution to obtain underlying T(e) and n(e) profiles is by consideration of scattered signals. However, deconvolution at the scattered signal level is complex since it requires knowledge of all spectral and absolute calibration data. In this paper a simple technique is presented where only knowledge of the instrument function I(r) and the measured profiles, T(e, observed)(r) and n(e, observed)(r), are required to obtain underlying T(e)(r) and n(e)(r). This method is appropriate for most TS systems and is particularly important where high spatial sampling is obtained relative to Δ(R).

2.
Rev Sci Instrum ; 81(10): 10D738, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033929

RESUMO

A motional Stark effect (MSE) diagnostic is now installed and operating routinely on the MAST spherical tokamak, with 35 radial channels, spatial resolution of ∼2.5 cm, and time resolution of ∼1 ms at angular noise levels of ∼0.5°. Conventional (albeit very narrow) interference filters isolate π or σ polarized emission. Avalanche photodiode detectors with digital phase-sensitive detection measure the harmonics of a pair of photoelastic modulators operating at 20 and 23 kHz, and thus the polarization state. The π component is observed to be significantly stronger than σ, in reasonably good agreement with atomic physics calculations, and as a result, almost all channels are now operated on π. Trials with a wide filter that admits the entire Stark pattern (relying on the net polarization of the emission) have demonstrated performance almost as good as the conventional channels. MSE-constrained equilibrium reconstructions can readily be produced between pulses.

3.
Rev Sci Instrum ; 79(10): 10F524, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044669

RESUMO

A multichord motional Stark effect (MSE) system has recently been built on the MAST tokamak. In MAST the pi and sigma lines of the MSE spectrum overlap due to the low magnetic field typical for present day spherical tokamaks. Also, the field curvature results in a large change in the pitch angle over the observation volume. The measured polarization angle does not relate to one local pitch angle but to an integration over all pitch angles in the observation volume. The velocity distribution of the neutral beam further complicates the measurement. To take into account volume effects and velocity distribution, an ab initio code was written that simulates the MSE spectrum on MAST. The code is modular and can easily be adjusted for other tokamaks. The code returns the intensity, polarized fraction, and polarization angle as a function of wavelength. Results of the code are presented, showing the effect on depolarization and wavelength dependence of the polarization angle. The code is used to optimize the design and calibration of the MSE diagnostic.

4.
Rev Sci Instrum ; 79(10): 10E730, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044546

RESUMO

A new infrared Thomson scattering system has been designed for the MAST tokamak. The system will measure at 120 spatial points with approximately 10 mm resolution across the plasma. Eight 30 Hz 1.6 J Nd:YAG lasers will be combined to produce a sampling rate of 240 Hz. The lasers will follow separate parallel beam paths to the MAST vessel. Scattered light will be collected at approximately f/6 over scattering angles ranging from 80 degrees to 120 degrees. The laser energy and lens size, relative to an existing 1.2 J f/12 system, greatly increases the number of scattered photons collected per unit length of laser beam. This is the third generation of this polychromator to be built and a number of modifications have been made to facilitate mass production and to improve performance. Detected scattered signals will be digitized at a rate of 1 GS/s by 8 bit analog to digital converters (ADCs.) Data may be read out from the ADCs between laser pulses to allow for real-time analysis.

5.
Phys Rev Lett ; 88(3): 035002, 2002 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-11801066

RESUMO

H-mode plasmas have been achieved on the MAST spherical tokamak at input power considerably higher than predicted by conventional threshold scalings. Following L- H transition, a clear improvement in energy confinement is obtained, exceeding recent international scalings even at densities approaching the Greenwald density limit. Transition is accompanied by an order-of-magnitude increase in edge-density gradient, a marked decrease in turbulence, the efficient conversion of internal electron Bernstein waves into free space waves, and the onset and saturation of edge poloidal rotation.