Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
J Prosthodont ; 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38517983

RESUMO

PURPOSE: To investigate the long-term implant survival rate and marginal bone loss (MBL) of implants with different variables associated over an observational period of at least 20 years. MATERIALS AND METHODS: Patients with at least one implant placed prior to 2001 were recalled and visited. Data on implant macro-design, prosthetic aspects, site distribution, and patient-related factors were collected. MBL was evaluated on intraoral X-rays and peri-implant soft tissue parameters were recorded. The patients were asked to fill out a questionnaire to evaluate their satisfaction with the treatment received. Descriptive statistics indicators were estimated. Analysis of variance and analysis of covariance models were used to investigate any differences in the MBL and peri-implant probing depth (PPD) among the variables. A chi-square analysis was performed to investigate any association between different types of prosthetic implant-supported rehabilitations and survival/success outcomes. RESULTS: Forty-one (41) patients and 174 implants were included with a mean observational period of 23.3 ± 2.8 years. The implant survival and success rates were 96.5% and 83.3% respectively, while 3.5% of early failures were detected. The lowest success rates were observed for implants supporting fixed full-arch rehabilitations (71.05%) and overdenture rehabilitations (86.11%). A mean MBL of 1.81 ± 0.71 mm and a mean PPD of 3.38 ± 1.62 mm were recorded. The interaction between the collected data with MBL and PPD did not reveal any statistically significant differences between the variables (p > 0.05). A statistically significant difference was recorded when analyzing the association between the different types of prosthetic implant-supported rehabilitations and success rates (p = 0.014), with fixed and removable full-arch rehabilitations presenting with lower success rates. Answers to the questionnaire showed a generally high level of satisfaction. CONCLUSIONS: Within the limits of this retrospective study and based on the results, an implant survival rate higher than 96% was observed after a mean observational period of 23.3 ± 2.8 years. Both the implant survival rate and MBL seemed stable after a mean observational period of 23.3 ± 2.8 years. Implants supporting fixed and removable full-arch rehabilitations seemed to present lower success rates over time. Implant rehabilitation seemed to provide patients with optimal long-term outcomes in terms of functional and psychological aspects.

2.
Int J Dent Hyg ; 22(2): 294-305, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-36951198

RESUMO

OBJECTIVES: To date, there is a lack of data regarding the acceptance of the guidelines for infective endocarditis (IE) prevention among dentists in Italy, and similarly, there are no data on the understanding and compliance of those among dental hygienists (DH). Thus, we tried to assess the ability of DH to recognize and manage categories of patients at high risk of EI, to identify which dental procedures are at increased risk and to assess the level of knowledge of doses and how antibiotic prophylaxis should be administered in specific cases. METHODS: An anonymous questionnaire was prepared and made accessible online by sharing a Google Forms® link; general personal data and educational background information were collected to obtain a profile of the participants. RESULTS: A total of 362 DH answered to our web-based survey, showing a prevalent female percentage (86.7%) and the most represented age group of 30-39 years old (43.1%). Regarding the gender differences, there were not overall statistically significant differences; similarly, we did not find any differences regarding the overall number of wrong questions if considering the different ages of the participant and the year of graduation. Graduates in Northern Italy have mistaken fewer questions than graduates in other geographical areas. CONCLUSION: To the best of our knowledge, this is the largest survey about the knowledge of IE for DH ever performed. Because the overprescription of antibiotics contributes to the development of drug resistance, antibiotic stewardship should be at the forefront of patient care. Our data reflect the need for placing a greater emphasis on IE prophylaxis education in training and during continuing professional development events for DH.


Assuntos
Endocardite Bacteriana , Endocardite , Humanos , Feminino , Adulto , Higienistas Dentários , Endocardite/complicações , Endocardite/tratamento farmacológico , Endocardite/prevenção & controle , Endocardite Bacteriana/prevenção & controle , Endocardite Bacteriana/tratamento farmacológico , Endocardite Bacteriana/etiologia , Antibioticoprofilaxia/efeitos adversos , Antibacterianos/uso terapêutico
3.
BMC Oral Health ; 22(1): 530, 2022 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-36424574

RESUMO

BACKGROUND: Data regarding the efficacy of the dental clearance required prior to kidney transplantation (KT) for preventing post-transplant complications is controversial. The aim of this retrospective study was to investigate a possible correlation between any untreated oral infectious foci and the onset of systemic complications in KT patients. METHODS: Patients scheduled for regular check-ups during the post-transplant period were visited at the C.I.R. Dental School in Turin, Italy. Patients were asked to bring orthopantomography (OPT) acquired prior to transplantation to compare the possible presence of untreated infectious foci at the time of transplantation with the time of their post-transplant visit. Patients were then divided, according to the evaluation of the OPT obtained prior to the transplantation, into two groups according to their dental status prior to the transplant. "Group Infected" was comprised of patients with no dental clearance, and "Group Clear" included patients with dental clearance. The medical records were then retrospectively reviewed for the evaluation of any systemic complications that occurred after transplantation. The following medical complications were considered: fever, pneumonia, urinary tract infections, systemic infections, kidney rejection, and death. Complications were divided in two groups: early complications, which occurred within 100 days of transplantation, and late complications, which occurred more than 100 days after transplantation. RESULTS: A total of 77 patients were enrolled in the study. Group Infected was composed of 19 subjects (25%), while Group Clear was composed of 58 patients (75%). In Group Infected, 13 (68%) patients developed complications within 100 days of transplantation, and 11 (58%) did so after 100 days. In Group Clear, 31 (53%) patients had complications within 100 days of the transplant, and 23 (40%) did after 100 days. Patients in Group Infected had a statistically significant increase in episodes of fever (p = 0.03), compared to Group Clear, with a higher relative risk (RR) of 3.66 in the first 100 days after transplantation. CONCLUSION: Within the limitations of the present retrospective pilot study, and based on the results, a correlation between the absence of dental clearance prior to KT and a higher RR of developing a fever within the first 100 days post transplantation was highlighted. The present results encourage doctors to continue research on the topic, which remains controversial. Further prospective studies are required to confirm the results of the present study.


Assuntos
Transplante de Rim , Doenças da Boca , Humanos , Transplante de Rim/efeitos adversos , Estudos Retrospectivos , Projetos Piloto , Doenças da Boca/etiologia , Itália
4.
BMC Oral Health ; 22(1): 482, 2022 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-36357901

RESUMO

BACKGROUND: Endodontic ledge (EL) formation is the most common complication of endodontic treatment. Although various etiological factors have been identified, canal curvature is the most significant variable correlated with EL formation. The aim of this micro-computed tomographic (micro-CT) study was to evaluate EL position in the mesial canals of the lower molars in relation to the degree of canal curvature. METHODS: Forty intact mandibular first molars with independent mesial canals with 20°-40° primary mesio-distal curvature, 10°-30° buccal-lingual canal curvature and 4 < r ≤ 8 mm main curvature radius were selected. Working length was measured with a K-File #10 and a high resolution pre-operative micro-CT analysis was performed. Ledges were created at the point of maximum canal curvature using stainless steel K-Files #30-35, alternating irrigation with 5% NaOCl and 10% EDTA. A post-operative high-resolution micro-CT analysis was then completed. Pre- and post-operative images were analyzed. The angle (α) formed between the vector passing through the geometric center of the EL and the center of the original canal lumen and the line joining the centers of the mesio-buccal and mesio-lingual canal orifices was calculated, and a descriptive statistical analysis was achieved. The α angle values were analyzed in relation to canal curvature using Kruskal-Wallis and post hoc Dunn's tests. The level of significance was set at P < 0.05. RESULTS: The α angles appeared inversely proportional to canal curvatures in the buccal-lingual and mesio-distal projections. The mean α angle was 36.4° (standard deviation 10.64; 95% confidence interval 34.1-40.9). CONCLUSION: Within the limitations of this study, endodontic ledges develop in the opposite direction to the three-dimensional canal curvature and their position is influenced by the degree of curvature. Clinically, the α angle values may be related to the recommended direction to manage endodontic ledges.


Assuntos
Cavidade Pulpar , Dente Molar , Humanos , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/cirurgia , Dente Molar/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Preparo de Canal Radicular/efeitos adversos , Preparo de Canal Radicular/métodos
5.
Int J Mol Sci ; 21(19)2020 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-32977633

RESUMO

Reconstruction of bony defects is challenging when conventional grafting methods are used because of their intrinsic limitations (biological cost and/or biological properties). Bone regeneration techniques are rapidly evolving since the introduction of three-dimensional (3D) bioprinting. Bone tissue engineering is a branch of regenerative medicine that aims to find new solutions to treat bone defects, which can be repaired by 3D printed living tissues. Its aim is to overcome the limitations of conventional treatment options by improving osteoinduction and osteoconduction. Several techniques of bone bioprinting have been developed: inkjet, extrusion, and light-based 3D printers are nowadays available. Bioinks, i.e., the printing materials, also presented an evolution over the years. It seems that these new technologies might be extremely promising for bone regeneration. The purpose of the present review is to give a comprehensive summary of the past, the present, and future developments of bone bioprinting and bioinks, focusing the attention on crucial aspects of bone bioprinting such as selecting cell sources and attaining a viable vascularization within the newly printed bone. The main bioprinters currently available on the market and their characteristics have been taken into consideration, as well.


Assuntos
Bioimpressão , Regeneração Óssea , Substitutos Ósseos/química , Impressão Tridimensional/instrumentação , Engenharia Tecidual , Alicerces Teciduais/química , Bioimpressão/instrumentação , Bioimpressão/métodos , Humanos , Engenharia Tecidual/instrumentação , Engenharia Tecidual/métodos
6.
BMC Oral Health ; 20(1): 271, 2020 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-33028288

RESUMO

BACKGROUND: Fully adjustable articulators and pantographs record and reproduce individual mandibular movements. Although these instruments are accurate, they are operator-dependant and time-consuming. Pantographic recording is affected by inter and intra operator variability in the individuation of clinical reference points and afterwards in reading pantographic recording themselves. Finally only border movements can be reproduced. METHODS: Bionic Jaw Motion system is based on two components: a jaw movement analyzer and a robotic device that accurately reproduces recorded movements. The jaw movement analyzer uses an optoelectronic motion system technology made of a high frequency filming camera that acquires 140frames per second and a custom designed software that recognizes and determines the relative distance at each point in time of markers with known geometries connected to each jaw. Circumferential modified retainers connect markers and do not cover any occlusal surfaces neither obstruct occlusion. The recording process takes 5 to 10 s. Mandibular movement performance requires six degrees of freedom of movement, 3 rotations and 3 translations. Other robots are based on the so-called delta mechanics that use several parallel effectors to perform desired movements in order to decompose a complex trajectory into multiple more simple linear movements. However, each parallel effector introduces mechanical inter-component tolerances and mathematical transformations that are required to transform a recorded movement into the combination of movements to be performed by each effector. Bionic Jaw Motion Robot works differently, owing to three motors that perform translational movements and three other motors that perform rotations as a gyroscope. This configuration requires less mechanical components thus reducing mechanical tolerances and production costs. Both the jaw movement analyzer and the robot quantify the movement of the mandible as a rigid body with six degrees of freedom. This represents an additional advantage as no mathematical transformation is needed for the robot to reproduce recorded movements. RESULTS: Based on the described procedure, Bionic Jaw Motion provide accurate recording and reproduction of maxillomandibular relation in static and dynamic conditions. CONCLUSION: This robotic system represents an important advancement compared to available analogical and digital alternatives both in clinical and research contexts for cost reduction, precision and time saving opportunities.


Assuntos
Robótica , Articuladores Dentários , Registro da Relação Maxilomandibular , Mandíbula , Movimento , Reprodução
7.
Int J Mol Sci ; 19(2)2018 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-29425177

RESUMO

The rapid development and application of nanotechnology to biological interfaces has impacted the bone implant field, allowing researchers to finely modulate the interface between biomaterials and recipient tissues. In the present study, oxidative anodization was exploited to generate two alumina surfaces with different pore diameters. The former displayed surface pores in the mean range of 16-30 nm, while in the latter pores varied from to 65 to 89 nm. The samples were characterized by Field Emission Scanning Electron Microscopy (FESEM) and Energy Dispersive X-ray spectroscopy (EDX) analysis prior to being tested with pre-osteoblastic MC3T3-E1 cells. In vitro cell response was studied in terms of early cell adhesion, viability, and morphology, including focal adhesion quantification. Both the alumina samples promoted higher cell adhesion and viability than the control condition represented by the standard culture dish plastic. Osteogenic differentiation was assessed through alkaline phosphatase activity and extracellular calcium deposition, and it was found that of the two nano-surfaces, one was more efficient than the other. By comparing for the first time two nano-porous alumina surfaces with different pore diameters, our data supported the role of nano-topography in inducing cell response. Modulating a simple aspect of surface texture may become an attractive route for guiding bone healing and regeneration around implantable metals.


Assuntos
Óxido de Alumínio/química , Nanoporos , Osteoblastos/efeitos dos fármacos , Alicerces Teciduais/química , Animais , Adesão Celular , Técnicas de Cultura de Células/métodos , Diferenciação Celular , Linhagem Celular , Camundongos , Osteoblastos/citologia , Osteoblastos/fisiologia , Alicerces Teciduais/efeitos adversos
8.
J Clin Med ; 13(2)2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-38256586

RESUMO

The present study aimed to investigate the effect of HA in improving post-extraction socket healing in subjects with diabetes mellitus (DM) type 2. DM patients requiring bilateral extraction of the homologous teeth were visited at the C.I.R. Dental School, University of Turin. After the extractions, one site was randomly assigned to the test (T) group (postoperative application of HA), while the other site was assigned to the control group (C, no treatment). Patients were then followed after 3, 7, 14, and 21 days. Primary outcomes were the healing index and socket closure. The Mann-Whitney test or the Student's t-test was used for nonparametric or parametric distributed variables. The chi-square test was used if the estimated data in any given cell were >5, otherwise the Fisher test was adopted. A p < 0.05 was considered statistically significant. In total, 36 patients (n = 36) were enrolled in this study for a total of 72 extractions (n = 72). Sockets treated with HA showed significantly (p < 0.05) better healing index values at day 7 (p = 0.01) and at day 14 (p = 0.02) and significantly (p < 0.05) better socket closure values at day 3 (p = 0.04), day 7 (p = 0.001) and day 14 (p = 0.001) compared to the C group. Based on the clinical results, HA seems to be promising in improving the timing and the quality of post-extractive wound healing in DM patients. Further clinical research, as well as histological investigations, are required to confirm the results.

9.
Int J Prosthodont ; 0(0): 0, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37729489

RESUMO

PURPOSE: This study aimed to evaluate the tensile strength of five different thicknesses of two resin cements placed between two titanium surfaces, before and after ageing. MATERIALS AND METHODS: One hundred titanium 5 grade models composed of two surfaces simulating a semiprecision attachment for overdenture and its housing in the framework, were used. Samples were cemented using two different resin cements (SoloCem and OT-Cem). Five groups representing five different cement thicknesses (from 50 to 250µm) were created by varying the housing diameter. A half of the sample underwent to a tensile strength test 24h after luting, while the other half after 30000 thermic cycles from 5°C to 55°C. Shapiro-Wilk and ANOVA with post-hoc tests were performed to relate the tensile strength to the variables: cement type, thermal ageing and cement thickness (p <0.05). RESULTS: Statistical differences were found between the cements both at T0 and T1; the mean values of tensile strength of SoloCem were three times higher than those of OT-Cem. The thermic cycles determined a reduction of the tensile force values for both cements; statistical evidence was found only for the SoloCem except for the 100µm thickness group. Significant differences were also found between the cement thicknesses of both cements, with 50µm and 100µm expressed the best tensile strength. Most of the fractures were of cohesive nature. CONCLUSION: SoloCem showed a higher tensile strength than OT-Cem but has been more stressed by the ageing. For each group the cement thickness influenced the tensile strength values with an inverse relationship.

10.
J Adhes Dent ; 25(1): 87-97, 2023 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-37093568

RESUMO

PURPOSE: To retrospectively evaluate the clinical behavior of direct anterior composite restorations performed with a universal adhesive or with a three-step etch-and-rinse (E&R) adhesive. MATERIAL AND METHODS: Patients were randomly treated with a three-step E&R adhesive (Optibond FL, Kerr) or a universal adhesive (Clearfil Universal Bond Quick, Kuraray Noritake) applied in E&R mode. All restorations were performed with a nanohybrid composite (ClearFil Majesty ES-2, Kuraray Noritake) by the same experienced operator. Two calibrated examiners evaluated the restorations using a dental mirror and explorer, in accordance with modified United States Public Health Service (USPHS) procedures. Clinical events were registered and classified as either failure (F), survival (SR), or success (S). RESULTS: 168 restorations were evaluated in 90 patients with an average follow-up period of 37.9 (± 22.9) months. A total of 132 restorations were performed on vital teeth, and 36 were performed on endodontically treated teeth (ETT). A total of 128 Class-IV and 40 Class-III restorations were performed. In 89 restorations, a three-step E&R adhesive was applied (14 Class-III and 75 Class-IV), while in 79, a universal adhesive was used (26 Class-III and 53 Class-IV, p = 0.0091). A Cox regression analysis was performed (p < 0.05) to analyze which factors were involved in the failure of the restorations, considering failure (F) as restorations that needed re-intervention at the follow-up period of 37.9 (± 22.9) months. No statistically significant differences were observed when considering parameters directly involved with the adhesives tested. Endodontically treated teeth were more prone to fractures (p = 0.0006) compared to vital teeth. Restorations made with universal adhesives failed by fracturing significantly more frequently (p = 0.0234), while restorations made on endodontically treated teeth had a significantly worse outcome (p = 0.0001). Restorations made on canines also failed significantly more frequently (HR = 3.8, 95% CI = 1.4-10.1, p = 0.0062). CONCLUSIONS: Based on the obtained results, both the universal adhesive and the three-step E&R adhesive proved to be good treatment choices for direct anterior restorations after 37.9 (± 22.9) months of follow-up. Tooth vitality seems fundamental for the prognosis of a direct anterior composite restoration over time.


Assuntos
Colagem Dentária , Dente não Vital , Humanos , Resinas Compostas/química , Colagem Dentária/métodos , Cimentos Dentários/química , Restauração Dentária Permanente/métodos , Adesivos Dentinários/química , Cimentos de Resina/química , Estudos Retrospectivos
11.
Materials (Basel) ; 16(2)2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36676569

RESUMO

BACKGROUND: The aim of the present study was to investigate the accuracy of a new digital impression system, comparing it to the plaster impression technique in the realization of full-arch implant-supported metal frameworks. METHODS: We took 11 scans (8 of the upper maxilla and 3 of the lower jaw) on a sample of nine patients previously rehabilitated with fixed full-arch screw-retained prostheses following the Columbus Bridge Protocol (CBP) with four to six implants (total: 51) since at least 4 months. Two impressions were taken for each dental arch: one analogic plaster impression using pick-up copings and an open tray technique and a second one using an intra-oral scanner. Two milled metal substructures were realised. The precision and passivity of the substructures were clinically analysed through the Sheffield test and endo-oral radiographs. Laboratory scans of the plaster casts obtained from an intra-oral scanner (IOS) and of the plaster casts obtained from traditional impression were compared with the intraoral scans following Hausdorff's method and an industrial digital method of optical detection to measure discrepancies. A Mann-Whitney test was performed in order to investigate average distances between surfaces after the superposition. RESULTS: The Sheffield test demonstrated an excellent passivity of the frameworks obtained through both the digital and the analogic method. In 81.81% of cases (n = 9) both substructures were found to have a perfect fit with excellent passivity, while in 18.18% (n = 2) of cases the substructures were found to have a very slight discrepancy. From the radiographic examination, no gaps between the frameworks and the implant heads or multiunit abutments were observed, with 100% accuracy. By superimposing digital files of scans according to Hausdorff's method, a statistically significant discrepancy (p = 0.006) was found between the digital scans and the digital models obtained from plaster impressions. Three-dimensional optical detection found a mean discrepancy of 0.11 mm between the analogic cast and the cast derived from the digital impression. CONCLUSIONS: The present study clinically demonstrates that milled implant-supported full-arch frameworks obtained through a digital scan and the herein described technique have an accuracy comparable to those obtained with traditional plaster impression.

12.
Minerva Dent Oral Sci ; 72(5): 230-238, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37194244

RESUMO

BACKGROUND: The aim of the present observational study was to investigate the application of transmucosal tissue-level implants in immediate loading full-arch rehabilitation with different variables associated. METHODS: Patients needing a full-arch implant rehabilitation were recruited and rehabilitated with four transmucosal tissue level implants. Data related to implants' diameters and lengths, jaw distributions, and presence of angulated abutments were collected. The following outcomes were evaluated: survival rate, marginal bone loss (MBL), Plaque Index (PI), bleeding on probing (BoP), probing depth (PD). Descriptive statistical analysis was reported and univariate linear regression models were built to assess a significant correlation between MBL and the different implant related factors. RESULTS: Twenty patients were rehabilitated for a total implant number of 80; 11 rehabilitations were performed on the maxilla, while 9 were performed on the mandible; 48 implants presented a 3.8 mm diameter and 32 implants presented a 4.25 mm diameter. Implants length varied between 10 to 15 mm; 40 tilted implants were connected to angulated abutment, while 40 straight implants were connected directly to the prostheses (no abutments). At the one year follow-up visit no implants failed resulting in an implant survival rate of 100%. The overall MBL was 1.19±0.30 mm. No statistically significant difference (P>0.05) was highlighted among any of the subgroups analyzed. CONCLUSIONS: Despite different variables associated, tissue level implants seem to represent a valid option when applied in immediate loading full-arch rehabilitation. Further research and longer observational periods are encouraged to confirm the result.

13.
Dent J (Basel) ; 10(7)2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35877390

RESUMO

Recently, tissue-level implants with a convergent collar have been introduced. While different studies have investigated the outcomes of this implant design in the rehabilitation of single teeth, its use in full-arch rehabilitation has yet to be investigated. The present case report describes the clinical outcomes of a full-arch immediate loading rehabilitation using tissue-level implants, with and without using implant-abutment units, with 2 years of follow-up. A female patient with mandibular terminal dentition and a high level of bone resorption (distal areas with a few millimeters of residual bone in the vertical dimension and both distal and anterior areas with narrow crestal bone in the horizontal dimension) was seen at the C.I.R Dental School, Turin, Italy. The patient was seeking to be rehabilitated with fixed prosthodontics, and she was found eligible for an immediate loading implant full-arch rehabilitation. Four implants were inserted in the same appointment. The two anterior implants were inserted straight and connected directly to the prosthesis (no abutments); the two distal implants were tilted in order to avoid the alveolar nerve and connected to two 30° angulated abutments. Two years post-implant placement, all of the implants were successfully integrated, resulting in an implant survival rate of 100%. The peri-implant soft tissues were stable at all the implant sites. No differences were highlighted between those implants with and without abutments. Within the limitations of the present clinical report, implant full-arch rehabilitations with tissue-level implants both with and without implant-abutment units showed optimal outcomes after two years of follow-up. Further research is encouraged to confirm whether this implant design may be a valid alternative to traditional implants in this type of rehabilitation, with or without implant-abutment units.

14.
Biomolecules ; 12(9)2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36139059

RESUMO

This paper aims to review the evidence of the cellular activity on titanium samples exposed to Plasma of Argon (PoA) treatment. A systematic review was carried out based on the PRISMA statement by searching the Cochrane Library, PubMed, Web of Science, EMBASE and Scopus, up to October 2020. Papers were selected according to PICOS format that is: Population (P): osteoblasts, fibroblasts, gingival cells; Intervention (I): PoA disinfection treatment; Comparison (C): untreated controls; Outcome (O): cell culture; Setting (S): in vitro assays. The quality assessment was performed according to the CRIS Guidelines (Checklist for Reporting In vitro Studies). A total of 661 articles were found, of which 16 were included. The quality assessment revealed an overall poor quality of the studies analyzed. In vitro studies on the potential of PoA showed a potential effect in promoting higher cell adhesion and protein adsorption in the earliest times (hours). This outcome was not so evident when later stages of cell growth on the surfaces were tested and compared to the control groups. Only one study was conducted in vivo on a human sample regarding abutment cleaning. No meta-analysis was conducted because of the variety of experimental settings, mixed methods and different cell lines studied. PoA seems to be effective in promoting cell adhesion and protein adsorption. The duration of this effect remains unclear. Further evidence is required to demonstrate the long-term efficacy of the treatment and to support the use of PoA treatment in clinical practice.


Assuntos
Osteoblastos , Titânio , Argônio/farmacologia , Adesão Celular , Humanos , Propriedades de Superfície , Titânio/farmacologia
15.
Biomedicines ; 10(7)2022 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-35884986

RESUMO

The present study aimed to evaluate the wear rate of polymer-infiltrated network composites and ceramics against enamel in a bruxism-simulated scenario. Ninety-six (n = 96) molars were divided into six groups (n = 16) according to their occlusal material: group 1-a polymer-infiltrated network ceramic (PINC); group 2-a second polymer-infiltrated network ceramic (PINC2); group 3-nanohybrid resin-based composite (CO); group 4-cubic zirconia (ZR); group 5-lithium disilicate (LS); and group 6-sound enamel (EN). A laser scanner was used to digitalize all of the occlusal surfaces before and after a fatigue test, which was conducted with a chewing simulator set at 80 N and semicircular movement in order to simulate bruxist movement and loads. Statistical analysis of volume loss was performed with a one-way ANOVA and post hoc Bonferroni test. ZR had significantly inferior wear to PINC (p ≤ 0.01) and CO (p = 0.04). LS wore the antagonist enamel significantly more than PINC, CO, PINC2 and EN (p ≤ 0.01). On the other hand, ZR wore the antagonist enamel significantly more than CO (p ≤ 0.01) and PINC2 (p = 0.05). In conclusion, PINCs better preserved antagonist enamel at the expense of a higher wear of their own. LS causes significantly higher enamel wear compared with PINCs. ZR caused significantly higher enamel wear compared with CO and PINC2, but it was wear-resistant.

16.
Clin Implant Dent Relat Res ; 24(5): 602-610, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35700161

RESUMO

OBJECTIVE: To compare the clinical outcomes of extra-short implants (≤6.5 mm) inserted with one-stage versus two-stage technique in adjacent sites of the upper or lower jaw. MATERIALS AND METHODS: In this split-mouth multicenter study, implants were randomly divided into two groups according to the healing phase: two-stage and one-stage technique. Primary outcome measures were implant survival, implant success, and prosthodontic complications. Secondary outcome measurements were: implant stability quotient (ISQ) collected at surgery time (T0), and after 3 (T3) and 12 (T12) months, marginal bone level (MBL) evaluated at T0, T3, T6, and T12, marginal bone loss evaluated at T6 and T12, plaque index (PI), probing depth (PD), bleeding on probing (BoP) evaluated at T3, T6, and T12. Significances of differences between groups were tested by linear mixed model with random intercept. RESULTS: Nineteen patients (8 males and 11 females) were included. A total of 38 implants were inserted. At T12 implant cumulative survival and implant success rate were 100% in both groups. No statistically significant differences were recorded for any of the analyzed parameters between the two groups at any time point. ISQ values were similar at T0 (two-stage: mean 67.53 ± SD 19.47; one-stage: mean 66.53 ± 19.07 p = 0.8738) and increased in both groups at the 12-month follow-up appointment (two-stage: 81.1 ± 7.04; one-stage: 81.39 ± 0.9266). MBL values were similar in the two groups at any time point. At T12 marginal bone loss was 0.46 ± 0.41 (two-stage) and 0.45 ± 0.38 (one-stage) mm (p = 0.9417), while mean PD was 2.7 ± 0.85 (two-stage) and 2.69 ± 0.89 (one-stage) mm. CONCLUSIONS: Within the limits of the present short-term report, extra-short implants demonstrated optimal clinical outcomes using the one-stage technique, without statistically significant differences compared with the traditional two-stage approach.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/etiologia , Índice de Placa Dentária , Feminino , Seguimentos , Humanos , Masculino , Mandíbula/cirurgia , Boca , Resultado do Tratamento
17.
Materials (Basel) ; 15(4)2022 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-35208121

RESUMO

The aim of this study was to evaluate the stability of prosthetic screws after applying cyclic loadings in an "all-on-four" rehabilitation model with the OT Bridge system. The model was tested both with and without anterior screws. Four implant analogues following the "all-on-four" concept were inserted in an edentulous mandibular resin model. An OT Bridge system with a Cr-Co prosthetic framework was fabricated. Depending on the presence or absence of one or two anterior screws on the implant analogues, three groups were created, i.e., Gr.1: three tightening screws, Gr.2: two tightening screws, Control Group: four tightening screws. Each single group underwent subsequent 400,000 cyclic loads, simulating approximately a year of chewing by using a dynamometer machine. This cycle was repeated five times for each group, and preload loss values were evaluated on each prosthetic screw after each cycle. All the data obtained were analyzed by one-way ANOVA and Student's t-test. No statistically significant differences after intragroup analysis were found. A statistically significant difference within the Gr.1 between the screws in positions 33 and 36, equal to 15.2% (p-value = 0.0176), was found. The OT Bridge seems a useful system to maintain the retention of a prosthesis during mechanical stress conditions even in the absence of one screw in an "all-on-four" rehabilitation. This could represent a good solution to solve the esthetic problem of the screw buccal access hole for fixed solutions.

18.
J Mech Behav Biomed Mater ; 125: 104886, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34695660

RESUMO

OBJECTIVE: To evaluate the effects of curing time, post-space region and cyclic fatigue on the micromechanical properties of a fiber-post luting cement. The null hypotheses were that (1) curing time, (2) fatigue and (3) post-space region does not affect the nanoindentation modulus and hardness of the dual-curing cement. MATERIALS AND METHODS: 48 premolars were endodontically treated and a class I cavity and 8 mm deep post space was prepared. Fiber posts were luted with a universal, dualized adhesive system and a dual-curing cement following manufacturer's instructions. Specimens were divided into three groups (16 specimens for each group) according to light-curing time (no light-curing, 20 s light-curing and 120 s light-curing), which was performed with a LED lamp at 1000 mW/cm 2. The coronal part of the cavity was restored using a nano-filled resin composite. After 24 h, 8 specimens for each group were randomly extract in order to undergo to fatigue test in wet condition through a chewing simulator, while the other specimens were kept in distilled water as benchmark. All the restored teeth were then sectioned in 1 mm thick slices perpendicularly to the fiber post axis. Specimen slices were classified in coronal and apical to be tested through a nanoindenter. Data were analyzed through Kruskal-Wallis test with a significance level of 1%, in order to evaluate the influence of treatments (i.e., curing time and cyclic loading) on the micromechanical properties of the tested luting cement. RESULTS: Both fatigue and curing time significantly influenced nanoindentation modulus and hardness of dual-curing cement (p < 0.01). No significant differences were reported for post space region. A significant interaction was found among the analyzed factors (p < 0.01). SIGNIFICANCE: 120 s light-curing time is recommended in order to achieve optimal mechanical proprieties, independently from post space region and cyclic fatigue. As matter of fact, 120 s light-curing allowed to prevent strain hardening induced by the fatigue simulation.


Assuntos
Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Cimentos Ósseos , Resinas Compostas , Cimentos de Ionômeros de Vidro
19.
Materials (Basel) ; 16(1)2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36614586

RESUMO

Background: The aim of the present multi-center split-mouth randomized control trial was to investigate the effect on peri-implant tissue of abutment with chromium nitride/ niobium nitride (CrN/NbN) coatings (superlattice) compared to traditional machined surface. Methods: Two adjacent posterior implants were inserted in 20 patients. A machined abutment was randomly screwed on either the mesial or distal implant, while a superlattice abutment was screwed on the other one. Implant survival rate, peri-implant probing depth (PPD), plaque index (PI), and bleeding index (BI) were collected 6 months after surgery, while marginal bone loss (MBL) was evaluated at T0 and T6.; Results: Implant survival rate was 97.7%. A total MBL of 0.77 ± 0.50 mm was recorded for superlattice abutments, while a mean MBL of 0.79 ± 0.40 mm was recorded for the abutment with machined surface. A mean PPD of 1.3 ± 0.23 mm was recorded for the superlattice Group, and a mean PPD of 1.31 ± 0.3 was recorded for the machined surface Group. PI was of 0.55 ± 0.51 for superlattice Group and 0.57 ± 0.50 for machined Group, while BI was of 0.47 ± 0.49 for superlattice Group and of 0.46 ± 0.40 for the machined one. No statistically significant difference was highlighted between the two Groups (p > 0.05). Conclusions: After a 6-month observational period, no statistically significant differences were highlighted between superlattice abutment and traditional machined abutment. Further in vitro studies as well as clinical research with longer follow-ups are required to better investigate the surface properties of the novel abutments' superlattice coating and its effect on the oral tissues.

20.
Polymers (Basel) ; 14(23)2022 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-36501478

RESUMO

The aim of the present study was to evaluate the fatigue to cyclic and static resistance of indirect restorations with different preparation designs made either of lithium disilicate (LS) or polymer-infiltrated ceramic network (PICN). Eighty-four (n = 84) molars were chosen, endodontically treated, and prepared with standardized MOD cavities. The molars were randomly divided into 6 study groups (n = 14) taking into account the "preparation design'' (occlusal veneer with 1.2 mm occlusal thickness; overlay with 1.6 mm occlusal thickness; adhesive crown with 2 mm occlusal thickness) and the "CAD/CAM material'' (E-max CAD, Ivoclar vivadent; Vita Enamic, Vita). A fatigue test was conducted with a chewing simulator set at 50 N for 1,500,000 cycles. Fracture resistance was assessed using a universal testing machine with a 6 mm diameter steel sphere applied to the specimens at a constant speed of 1 mm/min. A SEM analysis before the fracture test was performed to visually analyze the tooth-restoration margins. A statistical analysis was performed with a two-way ANOVA and a post-hoc pairwise comparison was performed using the Tukey test. The two-way ANOVA test showed that both the preparation design factor (p = 0.0429) and the CAD/CAM material factor (p = 0.0002) had a significant influence on the fracture resistance of the adhesive indirect restorations. The interaction between the two variables did not show any significance (p = 0.8218). The occlusal veneer had a lower fracture resistance than the adhesive crown (p = 0.042) but not lower than the overlay preparation (p = 0.095). LS was more resistant than PICN (p = 0.002). In conclusion, in the case of endodontically treated teeth, overlay preparation seems to be a valid alternative to the traditional full crown preparation, while occlusal veneers should be avoided in restoring non-vital molars with a high loss of residual tooth structure. LS material is more resistant compared to PICN.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA