RESUMO
INTRODUCTION: Cardiac radioablation (CR) is a noninvasive treatment option for patients with refractory ventricular tachycardia (VT) during which high doses of radiation, typically 25 Gy, are delivered to myocardial scar. In this study, we investigate motion from cardiac cycle and evaluate the dosimetric impact in a cohort of patients treated with CR. METHODS: This retrospective study included eight patients treated at our institution who had respiratory-correlated and ECG-gated 4DCT scans acquired within 2 weeks of CR. Deformable image registration was applied between maximum systole (SYS) and diastole (DIAS) CTs to assess cardiac motion. The average respiratory-correlated CT (AVGresp ) was deformably registered to the average cardiac (AVGcardiac ), SYS, and DIAS CTs, and contours were propagated using the deformation vector fields (DVFs). Finally, the original treatment plan was recalculated on the deformed AVGresp CT for dosimetric assessment. RESULTS: Motion magnitudes were measured as the mean (SD) value over the DVFs within each structure. Displacement during the cardiac cycle for all chambers was 1.4 (0.9) mm medially/laterally (ML), 1.6 (1.0) mm anteriorly/posteriorly (AP), and 3.0 (2.8) mm superiorly/inferiorly (SI). Displacement for the 12 distinct clinical target volumes (CTVs) was 1.7 (1.5) mm ML, 2.4 (1.1) mm AP, and 2.1 (1.5) SI. Displacements between the AVGresp and AVGcardiac scans were 4.2 (2.0) mm SI and 5.8 (1.4) mm total. Dose recalculations showed that cardiac motion may impact dosimetry, with dose to 95% of the CTV dropping from 27.0 (1.3) Gy on the AVGresp to 20.5 (7.1) Gy as estimated on the AVGcardiac . CONCLUSIONS: Cardiac CTV motion in this patient cohort is on average below 3 mm, location-dependent, and when not accounted for in treatment planning may impact target coverage. Further study is needed to assess the impact of cardiac motion on clinical outcomes.
Assuntos
Planejamento da Radioterapia Assistida por Computador , Taquicardia Ventricular , Humanos , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Radiometria/métodos , Tomografia Computadorizada Quadridimensional/métodosRESUMO
PURPOSE: Heart doses have been shown to be predictive of cardiac toxicity and overall survival (OS) for esophageal cancer patients. There is potential for functional imaging to provide valuable cardiac information. The purpose of this study was to evaluate the cardiac metabolic dose-response using 18 F-deoxyglucose (FDG)-PET and to assess whether standard uptake value (SUV) changes in the heart were predictive of OS. METHODS: Fifty-one patients with esophageal cancer treated with radiation who underwent pre- and post-treatment FDG-PET scans were retrospectively evaluated. Pre- and post-treatment PET-scans were rigidly registered to the planning CT for each patient. Pre-treatment to post-treatment absolute mean SUV (SUVmean) changes in the heart were calculated to assess dose-response. A dose-response curve was generated by binning each voxel in the heart into 10 Gy dose-bins and analyzing the SUVmean changes in each dose-bin. Multivariate cox proportional hazard models were used to assess whether pre-to-post treatment cardiac SUVmean changes predicted for OS. RESULTS: The cardiac dose-response curve demonstrated a trend of increasing cardiac SUV changes as a function of dose with an average increase of 0.044 SUV for every 10 Gy dose bin. In multivariate analysis, disease stage and SUVmean change in the heart were predictive (p < 0.05) for OS. CONCLUSIONS: Changes in pre- to post-treatment cardiac SUV were predictive of OS with patients having a higher pre- to post-treatment cardiac SUV change surviving longer.
Assuntos
Neoplasias Esofágicas , Fluordesoxiglucose F18 , Humanos , Fluordesoxiglucose F18/metabolismo , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/radioterapia , Coração/diagnóstico por imagem , Compostos RadiofarmacêuticosRESUMO
The primary objective is to evaluate the potential dosimetric gains of performing functional avoidance-based proton treatment planning using 4DCT derived ventilation imaging. 4DCT data of 31 patients from a prospective functional avoidance clinical trial were evaluated with intensity modulated proton therapy (IMPT) plans and compared with clinical volumetric modulated arc therapy (VMAT) plans. Dosimetric parameters were compared between standard and functional plans with IMPT and VMAT with one-way analysis of variance and post hoc paired student t-test. Normal Tissue Complication Probability (NTCP) models were employed to estimate the risk of two toxicity endpoints for healthy lung tissues. Dose degradation due to proton motion interplay effect was evaluated. Functional IMPT plans led to significant dose reduction to functional lung structures when compared with functional VMAT without significant dose increase to Organ at Risk (OAR) structures. When interplay effect is considered, no significant dose degradation was observed for the OARs or the clinical target volume (CTV) volumes for functional IMPT. Using fV20 as the dose metric and Grade 2+ pneumonitis as toxicity endpoint, there is a mean 5.7% reduction in Grade 2+ RP with the functional IMPT and as high as 26% in reduction for individual patient when compared to the standard IMPT planning. Functional IMPT was able to spare healthy lung tissue to avoid excess dose to normal structures while maintaining satisfying target coverage. NTCP calculation also shows that the risk of pulmonary complications can be further reduced with functional based IMPT.
Assuntos
Neoplasias Pulmonares , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Órgãos em Risco , Estudos Prospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por ComputadorRESUMO
BACKGROUND: The performance of left ventricular (LV) functional assessment using gated myocardial perfusion SPECT (MPS) relies on the accuracy of segmentation. Current methods require manual adjustments that are tedious and subjective. We propose a novel machine-learning-based method to automatically segment LV myocardium and measure its volume in gated MPS imaging without human intervention. METHODS: We used an end-to-end fully convolutional neural network to segment LV myocardium by delineating its endocardial and epicardial surface. A novel compound loss function, which encourages similarity and penalizes discrepancy between prediction and training dataset, is utilized in training stage to achieve excellent performance. We retrospectively investigated 32 normal patients and 24 abnormal patients, whose LV myocardial contours automatically segmented by our method were compared with those delineated by physicians as the ground truth. RESULTS: The results of our method demonstrated very good agreement with the ground truth. The average DSC metrics and Hausdorff distance of the contours delineated by our method are larger than 0.900 and less than 1 cm, respectively, among all 32 + 24 patients of all phases. The correlation coefficient of the LV myocardium volume between ground truth and our results is 0.910 ± 0.061 (P < 0.001), and the mean relative error of LV myocardium volume is - 1.09 ± 3.66%. CONCLUSION: These results strongly indicate the feasibility of our method in accurately quantifying LV myocardium volume change over the cardiac cycle. The learning-based segmentation method in gated MPS imaging has great promise for clinical use.
Assuntos
Ventrículos do Coração/diagnóstico por imagem , Miocárdio/patologia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Algoritmos , Estudos de Viabilidade , Feminino , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Redes Neurais de Computação , Reconhecimento Automatizado de Padrão , Perfusão , Probabilidade , Reprodutibilidade dos Testes , Estudos RetrospectivosRESUMO
PURPOSE: A form of lung functional imaging has been developed that uses 4DCT data to calculate ventilation (4DCT-ventilation). Because 4DCTs are acquired as standard-of-care to manage breathing motion during radiotherapy, 4DCT-ventilation provides functional information at no extra dosimetric or monetary cost. 4DCT-ventilation has yet to be described in children. 4DCT-ventilation can be used as a tool to help assess post-treatment lung function and predict for future clinical thoracic toxicities for pediatric patients receiving radiotherapy to the chest. The purpose of this work was to perform a preliminary evaluation of 4DCT-ventilation-based lung function changes for pediatric patients receiving radiotherapy to the lungs. METHODS: The study used four patients with pre and postradiotherapy 4DCTs. The 4DCTs, deformable image registration, and a density-change-based algorithm were used to compute pre and post-treatment 4DCT-ventilation images. The post-treatment 4DCT-ventilation images were compared to the pretreatment 4DCT-ventilation images for a global lung response and for an intrapatient dose-response (providing an assessment for dose-dependent regional dose-response). RESULTS: For three of the four patients, a global ventilation decline of 7-37% was observed, while one patient did not demonstrate a global functional decline. Dose-response analysis did not reveal an intrapatient dose-response from 0 to 20 Gy for three patients while one patient demonstrated increased 4DCT-ventilation decline as a function of increasing lung doses up to 50 Gy. CONCLUSIONS: Compared to adults, pediatric patients have unique lung function, dosimetric, and toxicity profiles. The presented work is the first to evaluate spatial lung function changes in pediatric patients using 4DCT-ventilation and showed lung function changes for three of the four patients. The early changes demonstrated with lung function imaging warrant further longitudinal work to determine whether the imaging-based early changes can be predicted for long-term clinical toxicity.
Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Adolescente , Criança , Tomografia Computadorizada Quadridimensional , Humanos , Pulmão , Ventilação Pulmonar , Planejamento da Radioterapia Assistida por Computador , RespiraçãoRESUMO
INTRODUCTION: 4DCT-ventilation is an exciting new imaging modality that uses 4DCT data to calculate lung-function maps. Because 4DCTs are acquired as standard of care for lung cancer patients undergoing radiotherapy, 4DCT-ventiltation provides functional information at no extra dosimetric or monetary cost to the patient. The development of clinical trials is underway to use 4DCT-ventilation imaging to spare functional lung in patients undergoing radiotherapy. The purpose of this work was to perform a virtual trial using retrospective data to develop the practical aspects of a 4DCT-ventilation functional avoidance clinical trial. METHODS: The study included 96 stage III lung cancer patients. A 4DCT-ventilation map was calculated using the patient's 4DCT-imaging, deformable registration, and a density-change-based algorithm. Clinical trial inclusion assessment used quantitative and qualitative metrics based on the patient's spatial ventilation profile. Clinical and functional plans were generated for 25 patients. The functional plan aimed to reduce dose to functional lung while meeting standard target and critical structure constraints. Standard and dose-function metrics were compared between the clinical and functional plans. RESULTS: Our data showed that 69% and 59% of stage III patients have regional variability in function based on qualitative and quantitative metrics, respectively. Functional planning demonstrated an average reduction of 2.8 Gy (maximum 8.2 Gy) in the mean dose to functional lung. CONCLUSIONS: Our work demonstrated that 60-70% of stage III patients would be eligible for functional planning and that a typical functional lung mean dose reduction of 2.8 Gy can be expected relative to standard clinical plans. These findings provide salient data for the development of functional clinical trials.
Assuntos
Ensaios Clínicos como Assunto , Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares/fisiopatologia , Ventilação Pulmonar , Algoritmos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional , Respiração , Estudos RetrospectivosRESUMO
The American Psychiatric Association (APA) has made major changes in the way mental illness is conceptualized, assessed, and diagnosed in its new diagnostic manual, the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5), published in 2013, and has far reaching implications for health care organizations and mental health policy. This paper reviews the four new principles in DSM-5: 1) A spectrum (also called "dimensional") approach to the definition of mental illness; 2) recognition of the role played by environmental risk factors related to stress and trauma in predisposing, precipitating, and perpetuating mental illness; 3) cultural relativism in diagnosis and treatment of mental illness; and 4) recognizing the adverse effects of psychiatric medications on patients. Each of these four principles will be addressed in detail. In addition, four major implications for health care organizations and mental health policy are identified as: 1) prevention; 2) client-centered psychiatry; 3) mental health workers retraining; and 4) medical insurance reform. We conclude that DSM- 5's new approach to diagnosis and treatment of mental illness will have profound implications for health care organizations and mental health policy, indicating a greater emphasis on prevention and cure rather than long-term management of symptoms.
Assuntos
Manual Diagnóstico e Estatístico de Transtornos Mentais , Política de Saúde , Transtornos Mentais/diagnóstico , Humanos , Transtornos Mentais/classificação , PsicometriaRESUMO
PURPOSE: To examine the association between pre-radiation therapy (RT) fluorine 18 fluorodeoxyglucose (FDG) uptake and post-RT symptomatic radiation pneumonitis (RP). MATERIALS AND METHODS: In accordance with the retrospective study protocol approved by the institutional review board, 228 esophageal cancer patients who underwent FDG PET/CT before chemotherapy and RT were examined. RP symptoms were evaluated by using the Common Terminology Criteria for Adverse Events, version 4.0, from the consensus of five clinicians. By using the cumulative distribution of standardized uptake values (SUVs) within the lungs, those values greater than 80%-95% of the total lung voxels were determined for each patient. The effect of pre-chemotherapy and RT FDG uptake, dose, and patient or treatment characteristics on RP toxicity was studied by using logistic regression. RESULTS: The study subjects were treated with three-dimensional conformal RT (n = 36), intensity-modulated RT (n = 135), or proton therapy (n = 57). Logistic regression analysis demonstrated elevated FDG uptake at pre-chemotherapy and RT was related to expression of RP symptoms. Study subjects with elevated 95% percentile of the SUV (SUV95) were more likely to develop symptomatic RP (P < .000012); each 0.1 unit increase in SUV95 was associated with a 1.36-fold increase in the odds of symptomatic RP. Receiver operating characteristic (ROC) curve analysis resulted in area under the ROC curve of 0.676 (95% confidence interval: 0.58, 0.77), sensitivity of 60%, and specificity of 71% at the 1.17 SUV95 threshold. CT imaging and dosimetric parameters were found to be poor predictors of RP symptoms. CONCLUSION: The SUV95, a biomarker of pretreatment pulmonary metabolic activity, was shown to be prognostic of symptomatic RP. Elevation in this pretreatment biomarker identifies patients at high risk for posttreatment symptomatic RP.
Assuntos
Neoplasias Esofágicas/radioterapia , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Pneumonite por Radiação/diagnóstico , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Estudos Retrospectivos , Medição de RiscoRESUMO
PURPOSE: To develop a quality assurance (QA) workflow by using a robust, curated, manually segmented anatomic region-of-interest (ROI) library as a benchmark for quantitative assessment of different image registration techniques used for head and neck radiation therapy-simulation computed tomography (CT) with diagnostic CT coregistration. MATERIALS AND METHODS: Radiation therapy-simulation CT images and diagnostic CT images in 20 patients with head and neck squamous cell carcinoma treated with curative-intent intensity-modulated radiation therapy between August 2011 and May 2012 were retrospectively retrieved with institutional review board approval. Sixty-eight reference anatomic ROIs with gross tumor and nodal targets were then manually contoured on images from each examination. Diagnostic CT images were registered with simulation CT images rigidly and by using four deformable image registration (DIR) algorithms: atlas based, B-spline, demons, and optical flow. The resultant deformed ROIs were compared with manually contoured reference ROIs by using similarity coefficient metrics (ie, Dice similarity coefficient) and surface distance metrics (ie, 95% maximum Hausdorff distance). The nonparametric Steel test with control was used to compare different DIR algorithms with rigid image registration (RIR) by using the post hoc Wilcoxon signed-rank test for stratified metric comparison. RESULTS: A total of 2720 anatomic and 50 tumor and nodal ROIs were delineated. All DIR algorithms showed improved performance over RIR for anatomic and target ROI conformance, as shown for most comparison metrics (Steel test, P < .008 after Bonferroni correction). The performance of different algorithms varied substantially with stratification by specific anatomic structures or category and simulation CT section thickness. CONCLUSION: Development of a formal ROI-based QA workflow for registration assessment demonstrated improved performance with DIR techniques over RIR. After QA, DIR implementation should be the standard for head and neck diagnostic CT and simulation CT allineation, especially for target delineation.
Assuntos
Algoritmos , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Garantia da Qualidade dos Cuidados de Saúde , Tomografia Computadorizada por Raios X , Idoso , Benchmarking , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos RetrospectivosRESUMO
Four-dimensional computed tomography (4D CT) is used to account for respiratory motion in radiation treatment planning, but artifacts resulting from the acquisition and postprocessing limit its accuracy. We investigated the efficacy of three experimental 4D CT acquisition methods to reduce artifacts in a prospective institutional review board approved study. Eighteen thoracic patients scheduled to undergo radiation therapy received standard clinical 4D CT scans followed by each of the alternative 4D CT acquisitions: 1) data oversampling, 2) beam gating with breathing irregularities, and 3) rescanning the clinical acquisition acquired during irregular breathing. Relative values of a validated correlation-based artifact metric (CM) determined the best acquisition method per patient. Each 4D CT was processed by an extended phase sorting approach that optimizes the quantitative artifact metric (CM sorting). The clinical acquisitions were also postprocessed by phase sorting for artifact comparison of our current clinical implementation with the experimental methods. The oversampling acquisition achieved the lowest artifact presence among all acquisitions, achieving a 27% reduction from the current clinical 4D CT implementation (95% confidence interval = 34-20). The rescan method presented a significantly higher artifact presence from the clinical acquisition (37%; p < 0.002), the gating acquisition (26%; p < 0.005), and the oversampling acquisition (31%; p < 0.001), while the data lacked evidence of a significant difference between the clinical, gating, and oversampling methods. The oversampling acquisition reduced artifact presence from the current clinical 4D CT implementation to the largest degree and provided the simplest and most reproducible implementation. The rescan acquisition increased artifact presence significantly, compared to all acquisitions, and suffered from combination of data from independent scans over which large internal anatomic shifts occurred.
Assuntos
Artefatos , Neoplasias Esofágicas/diagnóstico por imagem , Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Mesotelioma/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Idoso , Simulação por Computador , Neoplasias Esofágicas/radioterapia , Feminino , Humanos , Neoplasias Pulmonares/radioterapia , Medidas de Volume Pulmonar , Masculino , Mesotelioma/radioterapia , Estudos Prospectivos , Radiografia Torácica , Mecânica RespiratóriaRESUMO
A loop ileostomy with intraoperative anterograde colonic lavage has been described as an alternative to colectomy in the management of cases of Clostridium difficile infection refractory to medical treatment. We report a 69 years old diabetic women admitted with a septic shock. An abdominal CAT scan showed a pan-colitis that seemed to be infectious. A polymerase chain reaction was positive for Clostridium Difficile. Due to the failure to improve after full medical treatment, a derivative loop ileostomy and intra-operatory colonic lavage were performed, leaving a Foley catheter in the proximal colon. In the postoperative period, anterograde colonic instillations of Vancomycin flushes through the catheter were performed every 6 hours. Forty eight hours after surgery, the patient improved. A colonoscopy prior to discharge showed resolution of the pseudomembranous colitis.
Assuntos
Clostridioides difficile , Enterocolite Pseudomembranosa/terapia , Ileostomia/métodos , Irrigação Terapêutica/métodos , Idoso , Animais , Terapia Combinada/métodos , Feminino , Humanos , Vancomicina/administração & dosagemRESUMO
To evaluate the utility of automated deformable image registration (DIR) algorithms, it is necessary to evaluate both the registration accuracy of the DIR algorithm itself, as well as the registration accuracy of the human readers from whom the "gold standard" is obtained. We propose a Bayesian hierarchical model to evaluate the spatial accuracy of human readers and automatic DIR methods based on multiple image registration data generated by human readers and automatic DIR methods. To fully account for the locations of landmarks in all images, we treat the true locations of landmarks as latent variables and impose a hierarchical structure on the magnitude of registration errors observed across image pairs. DIR registration errors are modeled using Gaussian processes with reference prior densities on prior parameters that determine the associated covariance matrices. We develop a Gibbs sampling algorithm to efficiently fit our models to high-dimensional data, and apply the proposed method to analyze an image dataset obtained from a 4D thoracic CT study.
Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Estatísticos , Teorema de Bayes , Biometria/métodos , Simulação por Computador , Prova Pericial , Tomografia Computadorizada Quadridimensional/estatística & dados numéricos , Humanos , Distribuição NormalRESUMO
The benefits of four-dimensional computed tomography (4D CT) are limited by the presence of artifacts that remain difficult to quantify. A correlation-based metric previously proposed for ciné 4D CT artifact identification was further validated as an independent artifact evaluator by using a novel qualitative assessment featuring a group of observers reaching a consensus decision on artifact location and magnitude. The consensus group evaluated ten ciné 4D CT scans for artifacts over each breathing phase of coronal lung views assuming one artifact per couch location. Each artifact was assigned a magnitude score of 1-5, 1 indicating lowest severity and 5 indicating highest severity. Consensus group results served as the ground truth for assessment of the correlation metric. The ten patients were split into two cohorts; cohort 1 generated an artifact identification threshold derived from receiver operating characteristic analysis using the Youden Index, while cohort 2 generated sensitivity and specificity values from application of the artifact threshold. The Pearson correlation coefficient was calculated between the correlation metric values and the consensus group scores for both cohorts. The average sensitivity and specificity values found with application of the artifact threshold were 0.703 and 0.476, respectively. The correlation coefficients of artifact magnitudes for cohort 1 and 2 were 0.80 and 0.61, respectively, (p < 0.001 for both); these correlation coefficients included a few scans with only two of the five possible magnitude scores. Artifact incidence was associated with breathing phase (p < 0.002), with presentation less likely near maximum exhale. Overall, the correlation metric allowed accurate and automated artifact identification. The consensus group evaluation resulted in efficient qualitative scoring, reduced interobserver variation, and provided consistent identification of artifact location and magnitudes.
Assuntos
Artefatos , Imageamento Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
PURPOSE: Women remain underrepresented in medical physics in the United States, and determinants of persisting disparities remain unclear. Here, we performed a detailed investigation of American Association of Physicists in Medicine (AAPM) membership trajectories to evaluate trends in Full membership with respect to gender, age, and highest degree. METHODS AND MATERIALS: Membership data, including gender, date of birth, highest degree, membership type, and years of active membership for 1993 to 2023 were obtained from AAPM. Group 1 included Full members who joined AAPM in 1993 or later. A subset of group 1 including only members who joined and left AAPM since 1993 (former members, group 1F) was used to calculate age at membership cessation and duration. Results were compared by gender and highest degree. A Kaplan-Meier analysis was also used to evaluate membership "survival" by age and highest degree. RESULTS: Complete data were available for 6647 current and former Full members (group 1), including 2211 former members (group 1F). On average, women became Full members at a significantly younger age than men (34.6 vs 37.5 years of age, P < .001) and ended their memberships (if applicable) at a significantly younger age than men (46.1 vs 50.1 years of age, P < .001). The Kaplan-Meier "survival" analysis showed that for a given age, women were at a significantly greater risk of membership cessation than men, and women with master's degrees had the lowest membership survival of any gender/degree subgroup. When analyzing by membership duration, there was no difference in survival by gender alone. Still, women with PhDs were found to have the greatest membership survival among gender/degree subgroups. CONCLUSIONS: Both gender and degree type influenced AAPM membership trajectories. Although we have offered a discussion of possible explanations, qualitative data collected from both continuing and departing AAPM members will be critical in the ongoing journey toward gender parity in the profession of medical physics.
Assuntos
Física Médica , Feminino , Humanos , Estados Unidos , Masculino , Física Médica/estatística & dados numéricos , Adulto , Médicas/estatística & dados numéricos , Médicas/tendências , Sociedades Médicas , Pessoa de Meia-Idade , Fatores Etários , Fatores Sexuais , Estimativa de Kaplan-Meier , Sociedades CientíficasRESUMO
PURPOSE: A novel form of lung functional imaging applied for functional avoidance radiation therapy has been developed that uses 4-dimensional computed tomography (4DCT) data and image processing techniques to calculate lung ventilation (4DCT-ventilation). Lung segmentation is a common step to define a region of interest for 4DCT-ventilation generation. The purpose of this study was to quantitatively evaluate the sensitivity of 4DCT-ventilation imaging using different lung segmentation methods. METHODS AND MATERIALS: The 4DCT data of 350 patients from 2 institutions were used. Lung contours were generated using 3 methods: (1) reference segmentations that removed airways and pulmonary vasculature manually (Lung-Manual), (2) standard lung contours used for planning (Lung-RadOnc), and (3) artificial intelligence (AI)-based contours that removed the airways and pulmonary vasculature (Lung-AI). The AI model was based on a residual 3-dimensional U-Net and was trained using the Lung-Manual contours of 279 patients. We compared the Lung-RadOnc or Lung-AI with Lung-Manual contours for the entire 4DCT-ventilation functional avoidance process including lung segmentation (surface Dice similarity coefficient [Surface DSC]), 4DCT-ventilation generation (correlation), and subanalysis of 10 patients on a dosimetric endpoint (percentage of high functional volume of lung receiving ≥20 Gy [fV20{%}]). RESULTS: Surface DSC comparing Lung-Manual/Lung-RadOnc and Lung-Manual/Lung-AI contours was 0.40 ± 0.06 and 0.86 ± 0.04, respectively. The correlation between 4DCT-ventilation images generated with Lung-Manual/Lung-RadOnc and Lung-Manual/Lung-AI were 0.48 ± 0.14 and 0.85 ± 0.14, respectively. The difference in fV20[%] between 4DCT-ventilation generated with Lung-Manual/Lung-RadOnc and Lung-Manual/Lung-AI was 2.5% ± 4.1% and 0.3% ± 0.5%, respectively. CONCLUSIONS: Our work showed that using standard planning lung contours can result in significantly variable 4DCT-ventilation images. The study demonstrated that AI-based segmentations generate lung contours and 4DCT-ventilation images that are similar to those generated using manual methods. The significance of the study is that it characterizes the lung segmentation sensitivity of the 4DCT-ventilation process and develops methods that can facilitate the integration of this novel imaging in busy clinics.
Assuntos
Neoplasias Pulmonares , Ventilação Pulmonar , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Inteligência Artificial , Pulmão/diagnóstico por imagem , Tomografia Computadorizada Quadridimensional/métodosRESUMO
PURPOSE: A novel form of lung function imaging has been developed that uses 4-dimensional computed tomography (4DCT) data to generate lung ventilation images (4DCT-ventilation). Functional avoidance uses 4DCT-ventilation to reduce doses to functional lung with the aim of reducing pulmonary side effects. A phase 2, multicenter 4DCT-ventilation functional avoidance clinical trial was completed. The purpose of this work was to quantify changes in patient-reported outcomes (PROs) for patients treated with functional avoidance and determine which metrics are predictive of PRO changes. MATERIALS AND METHODS: Patients with locally advanced lung cancer receiving curative-intent radiation therapy were accrued. Each patient had a 4DCT-ventilation image generated using 4DCT data and image processing. PRO instruments included the Functional Assessment of Cancer Therapy-Lung (FACT-L) questionnaire administered pretreatment; at the end of treatment; and at 3, 6, and 12 months posttreatment. Using the FACT-Trial Outcome Index and the FACT-Lung Cancer Subscale results, the percentage of clinically meaningful declines (CMDs) were determined. A linear mixed-effects model was used to determine which patient, clinical, dose, and dose-function metrics were predictive of PRO decline. RESULTS: Of the 59 patients who completed baseline PRO surveys. 83% had non-small cell lung cancer, with 75% having stage 3 disease. The median dose was 60 Gy in 30 fractions. CMD FACT-Trial Outcome Index decline was 46.3%, 38.5%, and 26.8%, at 3, 6, and 12 months, respectively. CMD FACT-Lung Cancer Subscale decline was 33.3%, 33.3%, and 29.3%, at 3, 6, and 12 months, respectively. Although an increase in most dose and dose-function parameters was associated with a modest decline in PROs, none of the results were significant (all P > .053). CONCLUSIONS: The current work presents an innovative combination of use of functional avoidance and PRO assessment and is the first report of PROs for patients treated with prospective 4DCT-ventilation functional avoidance. Approximately 30% of patients had clinically significant decline in PROs at 12 months posttreatment. The study provides additional data on outcomes with 4DCT-ventilation functional avoidance.
Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Medidas de Resultados Relatados pelo Paciente , Qualidade de Vida , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Feminino , Estudos Prospectivos , Idoso , Pessoa de Meia-Idade , Pulmão/efeitos da radiação , Pulmão/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Idoso de 80 Anos ou maisRESUMO
OBJECTIVE: Current ventilation and perfusion dose-response studies focus on single-modalities (ventilation or perfusion) and perform pulmonary-toxicity assessment related to radiotherapy on a population-based basis. This study aims at quantitative and clinical evaluation of intrapatient differences between ventilation and perfusion dose-responses among lung cancer patients treated with radiotherapy. METHODS: 20 patients enrolled on a prospective functional avoidance protocol underwent single photon emission computed tomography-CT ventilation and perfusion scans pre- and post-radiotherapy. Relative changes in pre- to post-treatment ventilation and perfusion in lung regions receiving ≥20 Gy were calculated. In addition, the slopes of the linear fit to the relative ventilation and perfusion changes in regions receiving 0-60 Gy were calculated. A radiologist read and assigned a functional defect score to pre- and post-treatment ventilation/perfusion scans. RESULTS: 25% of patients had a difference >35% between ventilation and perfusion pre- to post-treatment changes and 20-30% of patients had opposite directions for ventilation and perfusion pre- to post-treatment changes. Using a semi-quantitative scale, radiologist assessment showed that 20% of patients had different pre- to post-treatment ventilation changes when compared to pre- to post-treatment perfusion changes. CONCLUSION: Our data showed that ventilation dose-response can differ from perfusion dose-response for 20-30% of patients. Therefore, when performing thoracic dose-response in cancer patients, it is insufficient to look at ventilation or perfusion alone; but rather both modes of functional imaging may be needed when predicting for clinical outcomes. ADVANCES IN KNOWLEDGE: The significance of this study can be highlighted by the differences between the intrapatient dose-response assessments of this analysis compared to existing population-based dose-response analyses. Elucidating intrapatient ventilation and perfusion dose-response differences may be valuable in predicting pulmonary toxicity in lung cancer patients post-radiotherapy.
Assuntos
Pneumopatias , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Estudos Prospectivos , Pulmão , Respiração , Tomografia Computadorizada de Emissão de Fóton Único/métodos , PerfusãoRESUMO
Purpose: While disparities in the inclusion and advancement of women and minorities in science, technology, engineering, mathematics, and medical fields have been well documented, less work has focused on medical physics specifically. In this study, we evaluate historical and current diversity within the medical physics workforce, in cohorts representative of professional advancement (PA) in the field, and within National Institutes of Health (NIH)-funded medical physics research activities. Methods and Materials: The 2020 American Association of Physicists in Medicine (AAPM) membership was queried as surrogate for the medical physics workforce. Select subsets of the AAPM membership were queried as surrogate for PA and early career professional advancement (ECPA) in medical physics. Self-reported AAPM-member demographics data representative of study analysis groups were identified and analyzed. Demographic characteristics of the 2020 AAPM membership were compared with those of the PA and ECPA cohorts and United States (US) population. The AAPM-NIH Research Database was appended with principal investigator (PI) demographics data and analyzed to evaluate trends in grant allocation by PI demographic characteristics. Results: Women, Hispanic/Latinx/Spanish individuals, and individuals reporting a race other than White or Asian alone comprised 50.8%, 18.7%, and 32.4% of the US population, respectively, but only 23.9%, 9.1%, and 7.9% of the 2020 AAPM membership, respectively. In general, representation of women and minorities was further decreased in the PA cohort; however, significantly higher proportions of women (P < .001) and Hispanic/Latinx/Spanish members (P < .05) were observed in the ECPA cohort than the 2020 AAPM membership. Analysis of historical data revealed modest increases in diversity within the AAPM membership since 2002. Across NIH grants awarded to AAPM members between 1985 and 2020, only 9.4%, 5.3%, and 1.7% were awarded to women, Hispanic/Latinx/Spanish, and non-White, non-Asian PIs, respectively. Conclusions: Diversity within medical physics is limited. Proactive policy should be implemented to ensure diverse, equitable, and inclusive representation within research activities, roles representative of PA, and the profession at large.
RESUMO
PURPOSE: Functional avoidance radiotherapy uses functional imaging to reduce pulmonary toxicity by designing radiotherapy plans that reduce doses to functional regions of the lung. A phase-II, multi-center, prospective study of 4DCT-ventilation functional avoidance was completed. Pre and post-treatment pulmonary function tests (PFTs) were acquired and assessed pulmonary function change. This study aims to evaluate which clinical, dose and dose-function factors predict PFT changes for patients treated with 4DCT-ventilation functional avoidance radiotherapy. MATERIALS AND METHODS: 56 patients with locally advanced lung cancer receiving radiotherapy were accrued. PFTs were obtained at baseline and three months following radiotherapy and included forced expiratory volume in 1-second (FEV1), forced vital capacity (FVC), and FEV1/FVC. The ability of patient, clinical, dose (lung and heart), and dose-function metrics (metrics that combine dose and 4DCT-ventilation-based function) to predict PFT changes were evaluated using univariate and multivariate linear regression. RESULTS: Univariate analysis showed that only dose-function metrics and the presence of chronic obstructive pulmonary disease (COPD) were significant (p<0.05) in predicting FEV1 decline. Multivariate analysis identified a combination of clinical (immunotherapy status, presence of thoracic comorbidities, smoking status, and age), along with lung dose, heart dose, and dose-function metrics in predicting FEV1 and FEV1/FVC changes. CONCLUSION: The current work evaluated factors predicting PFT changes for patients treated in a prospective functional avoidance radiotherapy study. The data revealed that lung dose- function metrics could predict PFT changes, validating the significance of reducing the dose to the functional lung to mitigate the decline in pulmonary function and providing guidance for future clinical trials.
Assuntos
Neoplasias Pulmonares , Pulmão , Humanos , Neoplasias Pulmonares/radioterapia , Estudos Prospectivos , Respiração , Testes de Função RespiratóriaRESUMO
PURPOSE: Gender-based discrimination and sexual harassment have been well-studied in the fields of science, technology, engineering, math, and medicine. However, less is known about these topics and their effect within the profession of medical physics. We aimed to better understand and clarify the views and experiences of practicing medical physicists and medical physics residents regarding gender-based discrimination and sexual harassment. METHODS AND MATERIALS: We conducted in-depth, semistructured, and confidential interviews with 32 practicing medical physicists and medical physics residents across the United States. The interviews were broad and covered the topics of discrimination, mentorship, and work/life integration. All participants were associated with a department with a residency program accredited by the Commission on Accreditation of Medical Physics Education Programs and had appointments with a clinical component. RESULTS: Participants shared views about gender-based discrimination and sexual harassment that were polarized. Some perceived that discrimination and harassment were a current concern within medical physics, while some either perceived that they were not a concern or that discrimination positively affected women and minoritized populations. Many participants shared personal experiences of discrimination and harassment, including those related to unequal compensation, discrimination against mothers, discrimination during the hiring process, gender-biased assumptions about behaviors or goals, communication biases, and overt and persistent sexual harassment. CONCLUSIONS: There is an urgent need to acknowledge, better understand, and address gender-based discrimination and sexual harassment in the field of medical physics.