Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 254
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38096587

RESUMO

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Cardiopatia Reumática , Insuficiência da Valva Tricúspide , Humanos , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/complicações , Cardiopatia Reumática/complicações , Estudos Retrospectivos
2.
Nucleic Acids Res ; 50(D1): D578-D586, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34718729

RESUMO

The Complex Portal (www.ebi.ac.uk/complexportal) is a manually curated, encyclopaedic database of macromolecular complexes with known function from a range of model organisms. It summarizes complex composition, topology and function along with links to a large range of domain-specific resources (i.e. wwPDB, EMDB and Reactome). Since the last update in 2019, we have produced a first draft complexome for Escherichia coli, maintained and updated that of Saccharomyces cerevisiae, added over 40 coronavirus complexes and increased the human complexome to over 1100 complexes that include approximately 200 complexes that act as targets for viral proteins or are part of the immune system. The display of protein features in ComplexViewer has been improved and the participant table is now colour-coordinated with the nodes in ComplexViewer. Community collaboration has expanded, for example by contributing to an analysis of putative transcription cofactors and providing data accessible to semantic web tools through Wikidata which is now populated with manually curated Complex Portal content through a new bot. Our data license is now CC0 to encourage data reuse. Users are encouraged to get in touch, provide us with feedback and send curation requests through the 'Support' link.


Assuntos
Curadoria de Dados/métodos , Bases de Dados de Proteínas , Complexos Multiproteicos/química , Coronavirus/química , Visualização de Dados , Bases de Dados de Compostos Químicos , Enzimas/química , Enzimas/metabolismo , Escherichia coli/química , Humanos , Cooperação Internacional , Anotação de Sequência Molecular , Complexos Multiproteicos/metabolismo , Interface Usuário-Computador
3.
Eur Heart J ; 44(33): 3121-3135, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37561995

RESUMO

Mitral valve prolapse (MVP) is the most frequent valve condition but remains a conundrum in many aspects, particularly in regard to the existence and frequency of an arrhythmic form (AMVP) and its link to sudden cardiac death. Furthermore, the presence, frequency, and significance of the anatomic functional feature called mitral annular disjunction (MAD) have remained widely disputed. Recent case series and cohorts have shattered the concept that MVP is most generally benign and have emphasized the various phenotypes associated with clinically significant ventricular arrhythmias, including AMVP. The definition, evaluation, follow-up, and management of AMVP represent the focus of the present review, strengthened by recent coherent studies defining an arrhythmic MVP phenotypic that would affect a small subset of patients with MVP at concentrated high risk. The role of MAD in this context is of particular importance, and this review highlights the characteristics of AMVP phenotypes and MAD, their clinical, multimodality imaging, and rhythmic evaluation. These seminal facts lead to proposing a risk stratification clinical pathway with consideration of medical, rhythmologic, and surgical management and have been objects of recent expert consensus statements and of proposals for new research directions.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Prolapso da Valva Mitral/complicações , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/complicações , Arritmias Cardíacas/terapia , Arritmias Cardíacas/complicações , Medição de Risco
4.
Eur Heart J ; 44(1): 28-40, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36167923

RESUMO

Adverse cardiac remodelling is the main determinant of patient prognosis in degenerative valvular heart disease (VHD). However, to give an indication for valvular intervention, current guidelines include parameters of cardiac chamber dilatation or function which are subject to variability, do not directly reflect myocardial structural changes, and, more importantly, seem to be not sensitive enough in depicting early signs of myocardial dysfunction before irreversible myocardial damage has occurred. To avoid irreversible myocardial dysfunction, novel biomarkers are advocated to help refining indications for intervention and risk stratification. Advanced echocardiographic modalities, including strain analysis, and magnetic resonance imaging have shown to be promising in providing new tools to depict the important switch from adaptive to maladaptive myocardial changes in response to severe VHD. This review, therefore, summarizes the current available evidence on the role of these new imaging biomarkers in degenerative VHD, aiming at shifting the clinical perspective from a valve-centred to a myocardium-focused approach for patient management and therapeutic decision-making.


Assuntos
Cardiomiopatias , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Humanos , Coração , Miocárdio/patologia , Cardiomiopatias/patologia , Biomarcadores
5.
Circulation ; 146(6): 480-493, 2022 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-35862182

RESUMO

BACKGROUND: Although transcatheter aortic valve replacement (TAVR) therapy continues to grow, there have been concerns about the occurrence of hypoattenuating leaflet thickening (HALT), which may affect prosthesis function or durability. This study aimed to examine prosthesis frame factors and correlate their extent to the frequency of HALT and clinical outcomes. METHODS: We prospectively examined 565 patients with cardiac computed tomography screening for HALT at 30 days after balloon-expandable SAPIEN3 and self-expanding EVOLUT TAVR. Deformation of the TAVR prostheses, asymmetric prosthesis leaflet expansion, prosthesis sinus volumes, and commissural alignment were analyzed on the postprocedural computed tomography. For descriptive purposes, an index of prosthesis deformation was calculated, with values >1.00 representing relative midsegment underexpansion. A time-to-event model was performed to evaluate the association of HALT with the clinical outcome. RESULTS: Overall, HALT was present in 21% of SAPIEN3 patients and in 16% of EVOLUT patients at 30 days after TAVR. The occurrence of HALT was directly associated with greater prosthesis frame deformation (P<0.001), worse asymmetry of the leaflets (P<0.001), and smaller TAVR neosinus volumes (P<0.001). These relations were present in both prosthetic types and in all of their size ranges (all P<0.05). In multivariable analyses that include clinical variables previously associated with HALT (eg, anticoagulant therapy), variables of TAVR prosthesis deformation remained predictive of HALT. Although HALT was not associated with changes in prosthetic hemodynamics, its presence was associated with the risk of mortality at 1 year, with respect to greater incidences of all-cause mortality (hazard ratio, 2.98 [95% CI, 1.57-5.63]; P=0.001), cardiac death (hazard ratio, 4.58 [95% CI, 1.81-11.6]; P=0.001), and a composite outcome of all-cause mortality and heart failure hospitalization (hazard ratio, 1.94 [95% CI, 1.14-3.30]; P=0.02) with adjustment for age, sex, and comorbidities. CONCLUSIONS: Nonuniform expansion of TAVR prostheses resulting in frame deformation, asymmetric leaflet, and smaller neosinus volume is related to occurrence of HALT in patients who undergo TAVR. These data may have implications for both prosthesis valve design and deployment techniques to improve clinical outcomes for these patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Am Heart J ; 258: 27-37, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36596333

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become the standard of care for most patients with severe aortic stenosis (AS), but the impact of medical therapy prescribing patterns on post-TAVR patients has not been thoroughly investigated. METHODS: We analyzed Optum claims data from 9,012 adults who received TAVR for AS (January 2014-December 2018). Pharmacy claims data were used to identify patients who filled ACEI/ARB and/or statin prescriptions during the study's 90-day landmark period post-TAVR. Kaplan-Meier and adjusted Cox Proportional Hazards models were used to evaluate the association of prescribing patterns with mortality during the 3-year follow-up period. Subgroup analyses were performed to examine the impact of 11 potential confounders on the observed associations. RESULTS: A significantly lower adjusted 3-year mortality was observed for patients with post-TAVR prescription for ACEI/ARBs (hazard ratio [HR] = 0.82, 95% confidence interval [CI] 0.74-0.91, P = .0003) and statins (HR = 0.85, 95% CI 0.77-0.94, P = .0018) compared to patients who did not fill prescriptions for these medications post-TAVR. Subgroup analyses revealed that the survival benefit associated with ACEI/ARB prescription was not affected by any of the potential confounding variables, except preoperative ACEI/ARB prescription was associated with significantly lower risk of mortality vs postoperative prescription only. No other subgroup variables had significant interactions associated with survival benefits, including preoperative use of statins. CONCLUSIONS: In this large-scale, real-world analysis of patients undergoing TAVR, the prescription of ACEI/ARB and statins was associated with a significantly lower risk of mortality at 3-years, especially in those where the medications were initiated preoperatively.


Assuntos
Estenose da Valva Aórtica , Inibidores de Hidroximetilglutaril-CoA Redutases , Substituição da Valva Aórtica Transcateter , Adulto , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Resultado do Tratamento , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Valva Aórtica/cirurgia , Fatores de Risco
7.
J Cardiovasc Magn Reson ; 24(1): 38, 2022 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-35725565

RESUMO

The 25th Society for Cardiovascular Magnetic Resonance (SCMR) Annual Scientific Sessions saw 1524 registered participants from more than 50 countries attending the meeting virtually. Supporting the theme "CMR: Improving Cardiovascular Care Around the World", the meeting included 179 invited talks, 52 sessions including 3 plenary sessions, 2 keynote talks, and a total of 93 cases and 416 posters. The sessions were designed so as to showcase the multifaceted role of cardiovascular magnetic resonance (CMR) in identifying and prognosticating various myocardial pathologies. Additionally, various social networking sessions as well as fun activities were organized. The major areas of focus for the future are likely to be rapid efficient and high value CMR exams, automated and quantitative acquisition and post-processing using artificial intelligence and machine learning, multi-contrast imaging and advanced vascular imaging including 4D flow.


Assuntos
Inteligência Artificial , Sistema Cardiovascular , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
8.
J Clin Ultrasound ; 50(2): 265-270, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34818437

RESUMO

PURPOSE: Despite continued efforts, a majority of patients with valvular heart disease (VHD) remain undiagnosed and untreated. This study aimed to assess the adoptability and accuracy of point-of-care handheld echocardiographic assessments (POCE) in the primary care setting. METHODS: Eleven previously untrained primary care providers were trained to use the Vscan Extend (GE, WI) POCE to assess VHD, left ventricular function (LVEF), and major extra-cardiac findings. Their assessments were compared to those of three blinded expert readers. A total of 175 patients underwent POCE assessments which were evaluated using Kappa statistics (κ) together with their estimated standard error, p value, and 95% CI bounds. RESULTS: Each patient had a mean of 3.3 ± 1.1 (±SD) assessments performed. Identical or nearly identical agreement between previously untrained primary providers and expert readers was evident for the diagnosis of tricuspid regurgitation, mitral regurgitation, pericardial effusion, and volume status. These agreements were strongest in apical long axis (κ = 1, p < 0.001) and parasternal long and short axis views (κ > =0.82 p < 0.001), though agreement remained robust in apical 4-chamber views (κ ≥ 0.76). The agreements in LVEF assessment were identical in the apical long axis view (κ = 1, p < 0.001) and robust in the remaining 3 views (κ > =0.66, p < 0.001). The assessments of aortic stenosis (parasternal/long, κ = 0.42, and parasternal/short, κ = 0.47, both p < 0.001) were weak in their agreement. CONCLUSION: Compared to expert echocardiography readers, the untrained providers' use of POCE for VHD shows high user adoptability and diagnostic accuracies in the primary care setting.


Assuntos
Doenças das Valvas Cardíacas , Sistemas Automatizados de Assistência Junto ao Leito , Ecocardiografia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Atenção Primária à Saúde , Função Ventricular Esquerda
9.
Funct Integr Genomics ; 21(3-4): 523-531, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34279742

RESUMO

Essential genes are so-called because they are crucial for organism perpetuation. Those genes are usually related to essential functions to cellular metabolism or multicellular homeostasis. Deleterious alterations on essential genes produce a spectrum of phenotypes in multicellular organisms. The effects range from the impairment of the fertilization process, disruption of fetal development, to loss of reproductive capacity. Essential genes are described as more evolutionarily conserved than non-essential genes. However, there is no consensus about the relationship between gene essentiality and gene age. Here, we identified essential genes in five model eukaryotic species (Saccharomyces cerevisiae, Schizosaccharomyces pombe, Drosophila melanogaster, Caenorhabditis elegans, and Mus musculus) and estimate their evolutionary ancestry and their network properties. We observed that essential genes, on average, are older than other genes in all species investigated. The relationship of network properties and gene essentiality convey with previous findings, showing essential genes as important nodes in biological networks. As expected, we also observed that essential orthologs shared by the five species evaluated here are old. However, all the species evaluated here have a specific set of young essential genes not shared among them. Additionally, these two groups of essential genes are involved with distinct biological functions, suggesting two sets of essential genes: (i) a set of old essential genes common to all the evaluated species, regulating basic cellular functions, and (ii) a set of young essential genes exclusive to each species, which perform specific essential functions in each species.


Assuntos
Caenorhabditis elegans , Drosophila melanogaster , Evolução Molecular , Genes Essenciais , Saccharomyces cerevisiae , Schizosaccharomyces , Animais , Caenorhabditis elegans/genética , Drosophila melanogaster/genética , Camundongos , Saccharomyces cerevisiae/genética , Schizosaccharomyces/genética
10.
BMC Cardiovasc Disord ; 21(1): 108, 2021 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-33607944

RESUMO

BACKGROUND: The natural history of patients with moderate aortic stenosis (AS) is poorly understood. We aimed to determine the long-term outcomes of patients with moderate AS. METHODS: We examined patients with moderate AS defined by echocardiography in our healthcare system, and performed survival analyses for occurrence of death, heart failure (HF) hospitalization, and progression of AS, with accounting for symptoms, left ventricular dysfunction, and comorbidities. RESULTS: We examined 729 patients with moderate AS (median age, 76 years; 59.9 % men) with a median follow-up of 5.0 years (interquartile range: 2.0 to 8.1 years). The 5-year overall survival was 52.3 % (95 % confidence interval [CI]: 48.6 % to 56.0 %) and survival free of death or HF hospitalization was 43.2 % (95 % CI: 39.5 % to 46.9 %). Worse New York Heart Association (NYHA) functional class was associated with poor long-term survival, with mortality rates ranging from 7.9 % (95 % CI: 6.6-9.2 %) to 25.2 % (95 % CI: 20.2-30.3 %) per year. Among patients with minimal or no symptoms, no futility markers, and preserved left ventricular function, 5-year overall survival was 71.9 % (95 % CI: 66.4-77.4 %) and survival free of death or HF hospitalization was 61.4 % (95 % CI: 55.5-67.3 %). Risk factors associated with adverse events were age, NYHA class, low ejection fraction and high aortic valve velocity (all p < 0.05). CONCLUSIONS: Patients with moderate AS are at significant risk of death. Our findings highlight the need for more study into appropriate therapeutic interventions to improve the prognosis of these patients.


Assuntos
Estenose da Valva Aórtica/mortalidade , Insuficiência Cardíaca/mortalidade , Disfunção Ventricular Esquerda/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/terapia , Comorbidade , Progressão da Doença , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Estudos Longitudinais , Masculino , Intervalo Livre de Progressão , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda
11.
Rev Panam Salud Publica ; 45: e65, 2021.
Artigo em Português | MEDLINE | ID: mdl-34007263

RESUMO

OBJECTIVE: To describe the characteristics of fake news about COVID-19 disseminated in Brazil from January to June 2020. METHOD: The fake news recorded until 30 June 2020 in two websites (Globo Corporation website G1 and Ministry of Health) were collected and categorized according to their content. From each piece of fake news, the following information was extracted: publication date, title, channel (e.g., WhatsApp), format (text, photo, video), and website in which it was recorded. Terms were selected from fake news titles for analysis in Google Trends to determine whether the number of searches using the selected terms had increased after the fake news appeared. The Brazilian regions with the highest percent increase in searches using the terms were also identified. RESULTS: In the two websites, 329 fake news about COVID-19 were retrieved. Most fake news were spread through WhatsApp and Facebook. The most frequent thematic categories were: politics (20.1%), epidemiology and statistics (e.g., proportion of cases and deaths) (19.5%), and prevention (16.1%). According to Google Trends, the number of searches using the terms retrieved from the fake news increased 34.3% during the period studied. The largest increase was recorded in the Southeast (45.1%) and the Northeast (27.8%). CONCLUSIONS: The fake news spread during the first 6 months of the COVID-19 pandemic in Brazil were characterized by political content as well as misinformation about the number of cases and deaths and about prevention measures and treatment. The main dissemination channels were WhatsApp and Facebook, with the use of messages, images, and videos, with greater reach in the Southeast and Northeast of Brazil.


OBJETIVO: Analizar algunas características de las noticias falsas sobre la COVID-19 en circulación en Brasil de enero a junio del 2020. MÉTODOS: Se recolectaron las noticias falsas registradas hasta el 30 de junio del 2020 en dos sitios (G1, perteneciente a la Corporación Globo, y el Ministerio de Salud) y se clasificaron de acuerdo con su contenido. Se extrajeron los siguientes datos de cada noticia engañosa: fecha de circulación, título, canal (por ejemplo, WhatsApp) y formato de divulgación (texto, fotografía o video) y portal de registro. Se analizaron en Google Trends los términos encontrados en los títulos de las noticias falsas para determinar si había aumentado el número de búsquedas en Google con esos términos después de la difusión de una noticia engañosa. También se determinaron las macrorregiones brasileñas con el mayor aumento porcentual en las búsquedas hechas con los términos analizados. RESULTADOS: Se encontraron 329 noticias falsas relacionadas con la pandemia de COVID-19 en los sitios estudiados (253 en el G1 y 76 en el Ministerio de Salud). Esas noticias se divulgaron principalmente por medio de WhatsApp y Facebook. Las categorías temáticas más frecuentes fueron política (por ejemplo, falsificación de la vacuna contra la COVID-19 por los gobernantes, 20,1%), epidemiología y estadística (proporción de casos y muertes, 19,5%) y prevención (16,1%). Según Google Trends, aumentaron un 34,3% las búsquedas en las cuales se utilizaban términos contenidos en las noticias falsas. El mayor aumento de esa clase se registró en el sudeste (45,1%) y el nordeste (27,8%) del país. CONCLUSIONES: Las noticias falsas divulgadas durante los seis primeros meses de la pandemia de COVID-19 en Brasil se caracterizaron por contenidos de posicionamiento político y desinformación sobre el número de casos y muertes y sobre las medidas de prevención y tratamiento. Los principales medios de divulgación fueron WhatsApp y Facebook, con utilización de mensajes, imágenes y videos, y un mayor alcance en las regiones sudeste y nordeste del país.

12.
Catheter Cardiovasc Interv ; 96(4): 972-978, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32077618

RESUMO

BACKGROUND: We sought to quantify and compare changes in quality of life measures after transcatheter aortic valve replacement (TAVR) in patients with low-flow (LF) and normal-flow (NF) aortic stenosis (AS). METHODS: We included 297 patients treated with TAVR at Abbott Northwestern Hospital from January 2015 to October 2017. Health status was assessed at baseline and 30 days post-procedure using the Kansas City Cardiomyopathy Questionnaire 12 (KCCQ-12). Overall (KCCQ-OS) and domain-specific (physical limitation, symptom frequency, quality of life, and social limitation) scores were compared in three subsets of patients as defined by stroke volume index (≤ or >35 ml/m2 ), ejection fraction (EF) (≤ or >40%), and mean gradient (≤ or >40 mmHg). RESULTS: Of the 297 patients included, 129 (43%) had NF high-gradient (NF AS group) and 168 (56%) had LF severe AS, including 25 (8%) with low EF (8%) ("Classical" low-flow low-gradient LEF [LF-LG-LEF] group) and 143 (48%) with preserved EF ("Paradoxical" LF-LG group). At baseline, patients with LF-LG-LEF AS had more severe impairment in symptoms frequency (p = .06) but similar KCCQ-OS. At 1-month after TAVR, all groups had moderate improvements in quality of life (Delta KCCQ-OS: "Classical" LF-LG-LEF 18 ± 21, paradoxical AS 14 ± 18, and NF AS 15 ± 16, p = .57). During a median follow-up time of 2.4 years, there was no difference in mortality (p = .34) but patients with paradoxical LF-LG AS had a higher risk of rehospitalization for heart failure (p = .01). CONCLUSIONS: Patients with LF severe AS derive significant improvements in quality of life measures after TAVR, indistinguishable from patients with NF AS.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Hemodinâmica , Qualidade de Vida , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Nível de Saúde , Humanos , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Inquéritos e Questionários , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 95(5): 1034-1041, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-31419009

RESUMO

BACKGROUND: There is conflicting data as to whether diastolic dysfunction (DD) affects the prognosis of patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). METHODS: Consecutive patients undergoing TAVR underwent assessment of DD with preoperative echocardiography and NT-pro BNP. Long-term survival was ascertained every 6 months by clinic visits or phone. DD was graded according to the new American Society of Echocardiography recommendations. Health status was assessed at baseline and 30 days post-procedure using the KCCQ-12 questionnaire. Long-term survival was displayed using Kaplan-Meier curves according to NT-pro BNP levels and DD grades. RESULTS: We included 222 patients, mean age 78 (±8) years, median STS score 4 (interquartile range = 3-7), median follow-up time 385 days (IQR = 180-640). DD was absent in 25, Grade I in 13, Grade II in 74, Grade III in 24, and indeterminate in 86 patients. Advanced (Grades II-III) DD was associated with higher pre-procedural NT-pro BNP levels (p < .001), worse quality of life (p < .001) but similar surgical risk (p = .43). Advanced and indeterminate DD were associated with increased long-term mortality (25-28% vs. 5%, p = .02) and elevated NT-pro BNP levels (26.4% vs. 9.8%, p = .05). Improvements in quality of life measures were seen in all DD groups (median change in KCCQ score no or Grade I DD:14 [3-21] vs. Grades II-III DD: 15 [16-26; p = .37]). CONCLUSION: Preoperative NT-pro BNP levels and echocardiographic indices of indeterminate or advanced DD are associated with increased long-term mortality after TAVR but similar improvements in quality of life.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Qualidade de Vida , Substituição da Valva Aórtica Transcateter/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Biomarcadores/sangue , Diástole , Feminino , Humanos , Masculino , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Estudos Prospectivos , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade
14.
Kidney Int ; 96(4): 836-849, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31543156

RESUMO

Chronic kidney disease (CKD) is a major risk factor for valvular heart disease (VHD). Mitral annular and aortic valve calcifications are highly prevalent in CKD patients and commonly lead to valvular stenosis and regurgitation, as well as complications including conduction system abnormalities and endocarditis. VHD, especially mitral regurgitation and aortic stenosis, is associated with significantly reduced survival among CKD patients. Knowledge related to VHD in the general population is not always applicable to CKD patients because the pathophysiology may be different, and CKD patients have a high prevalence of comorbid conditions and elevated risk for periprocedural complications and mortality. This Kidney Disease: Improving Global Outcomes (KDIGO) review of CKD and VHD seeks to improve understanding of the epidemiology, pathophysiology, diagnosis, and treatment of VHD in CKD by summarizing knowledge gaps, areas of controversy, and priorities for research.


Assuntos
Estenose da Valva Aórtica/epidemiologia , Valva Aórtica/patologia , Calcinose/epidemiologia , Endocardite/epidemiologia , Insuficiência da Valva Mitral/epidemiologia , Estenose da Valva Mitral/epidemiologia , Insuficiência Renal Crônica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/terapia , Calcinose/diagnóstico , Calcinose/etiologia , Calcinose/terapia , Congressos como Assunto , Endocardite/diagnóstico , Endocardite/etiologia , Endocardite/terapia , Humanos , Valva Mitral/patologia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/terapia , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Mitral/etiologia , Estenose da Valva Mitral/terapia , Prevalência , Fatores de Risco
16.
J Cardiovasc Magn Reson ; 19(1): 98, 2017 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-29212513

RESUMO

BACKGROUND: Non-invasive cardiac imaging allows detection of cardiac amyloidosis (CA) in patients with aortic stenosis (AS). Our objective was to estimate the prevalence of clinically suspected CA in patients with moderate and severe AS referred for cardiovascular magnetic resonance (CMR) in age and gender categories, and assess associations between AS-CA and all-cause mortality. METHODS: We retrospectively identified consecutive AS patients defined by echocardiography referred for further CMR assessment of valvular, myocardial, and aortic disease. CMR identified CA based on typical late-gadolinium enhancement (LGE) patterns, and ancillary clinical evaluation identified suspected CA. Survival analysis with the Log rank test and Cox regression compared associations between CA and mortality. RESULTS: There were 113 patients (median age 74 years, Q1-Q3: 62-82 years), 96 (85%) with severe AS. Suspected CA was present in 9 patients (8%) all > 80 years. Among those over the median age of 74 years, the prevalence of CA was 9/57 (16%), and excluding women, the prevalence was 8/25 (32%). Low-flow, low-gradient physiology was very common in CA (7/9 patients or 78%). Over a median follow-up of 18 months, 40 deaths (35%) occurred. Mortality in AS + CA patients was higher than AS alone (56% vs. 20% at 1-year, log rank 15.0, P < 0.0001). Adjusting for aortic valve replacement modeled as a time-dependent covariate, Society of Thoracic Surgery predicted risk of mortality, left ventricular ejection fraction, CA remained associated with all-cause mortality (HR = 2.92, 95% CI = 1.09-7.86, P = 0.03). CONCLUSIONS: Suspected CA appears prevalent among older male patients with AS, especially with low flow, low gradient AS, and associates with all-cause mortality. The importance of screening for CA in older AS patients and optimal treatment strategies in those with CA warrant further investigation, especially in the era of transcatheter aortic valve implantation.


Assuntos
Amiloidose/epidemiologia , Estenose da Valva Aórtica/epidemiologia , Cardiomiopatias/epidemiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Amiloidose/diagnóstico por imagem , Amiloidose/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/mortalidade , Distribuição de Qui-Quadrado , Comorbidade , Meios de Contraste/administração & dosagem , Ecocardiografia Doppler , Feminino , Gadolínio/administração & dosagem , Implante de Prótese de Valva Cardíaca , Compostos Heterocíclicos/administração & dosagem , Humanos , Estimativa de Kaplan-Meier , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Compostos Organometálicos/administração & dosagem , Pennsylvania/epidemiologia , Prevalência , Prognóstico , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Fatores de Tempo
17.
Curr Cardiol Rep ; 18(9): 89, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27448403

RESUMO

Non-invasive external magnetic resonance imaging (MRI) of large vessel atherosclerosis is a robust and promising imaging modality that can be applied for the evaluation of the atherosclerotic process in large vessels. However, it requires expertise for setup and time for data acquisition and analysis. Intravascular MRI is a promising tool, but its use remains at the pre-clinical stage within selected research groups. In this review, the current status and future role of intravascular MRI for atherosclerotic plaque characterization are summarized, along with important challenges which will be necessary to overcome prior to the wide adoption of this technique.


Assuntos
Procedimentos Endovasculares/métodos , Angiografia por Ressonância Magnética/métodos , Placa Aterosclerótica/diagnóstico por imagem , Procedimentos Endovasculares/tendências , Humanos , Artéria Ilíaca/diagnóstico por imagem , Angiografia por Ressonância Magnética/tendências
18.
Circulation ; 138(18): 1948-1950, 2018 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-30372139
19.
Am Heart J ; 168(2): 220-8.e1, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25066562

RESUMO

UNLABELLED: Cardiac magnetic resonance (CMR) identifies important prognostic variables in ischemic cardiomyopathy (ICM) patients such as left ventricular (LV) volumes, LV ejection fraction (LVEF), peri-infarct zone, and myocardial scar burden (MSB). It is unknown whether Doppler-based diastolic dysfunction (DDF) retains its prognostic value in ICM patients, in the context of current imaging, medical, and device therapies. METHODS: Diastolic function was evaluated in ICM patients (LVEF ≤ 40% and ≥ 70% stenosis in ≥ 1 coronary artery) who underwent transthoracic echocardiogram and delayed hyperenhancement CMR studies within 7 days. The association of DDF with the combined end point was assessed after risk-adjustment using Cox proportional hazards models. RESULTS: A total of 360 patients with severe LV dysfunction (LVEF = 24 ± 9%) and extensive MSB (31 ± 17%) were evaluated; DDF was present in all patients (stage 1%-44%, stage 2%-25%, stage 3%-31%). There were 130 events (124 deaths and 6 heart transplants) over a median follow-up of 5.8 years (IQR, 3.7-7.4 years). On multivariable analysis, DDF > stage 1 (HR, 1.37; P = .007) was associated with the combined end-point, independent of clinical risk score (HR, 2.40; P < .0001), implantable cardioverter defibrillator implantation (HR, 0.60; P = .009), incomplete revascularization (HR, 1.32; P = .003), mitral regurgitation (HR, 3.37; P = .01), peri-infarct zone area (HR, 1.04; P = 0.02), and MSB (HR, 1.02; P = .01). DDF had incremental prognostic value for the combined end-point (model χ(2) increased from 89 to 95, P = .02). CONCLUSION: DDF is a powerful predictor of mortality in ICM patients with significant LV dysfunction, independent of clinical and CMR data. DDF assessment provides incremental value, improving risk stratification.


Assuntos
Cardiomiopatias/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/mortalidade , Cicatriz/patologia , Meios de Contraste , Estenose Coronária , Diástole/fisiologia , Feminino , Humanos , Aumento da Imagem , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio , Isquemia Miocárdica/patologia , Isquemia Miocárdica/fisiopatologia , Miocárdio/patologia , Prognóstico , Modelos de Riscos Proporcionais , Medição de Risco , Ultrassonografia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia
20.
J Cardiol ; 83(6): 351-358, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38432474

RESUMO

Transcatheter aortic valve replacement (TAVR) has emerged as a preferred treatment modality for aortic stenosis, marking a significant advancement in cardiac interventions. Transcatheter heart valves (THVs) have also received approval for treating failed bioprosthetic valves and rings across aortic, mitral, tricuspid, and pulmonic positions. Unlike surgically implanted valves, which are sewn into the annulus, THVs are anchored through relative oversizing. Although THVs are designed to function optimally in a fully expanded state, they exhibit a certain degree of tolerance to underexpansion. However, significant deformation beyond this tolerance can adversely affect the valve's hemodynamics and durability, ultimately impacting patient outcomes. Such post-implantation deviations from the valve's intended three-dimensional design are influenced by a variety of physiological and anatomical factors unique to each patient and procedure, leading to underexpansion, eccentric expansion, and vertical deformation. These deformation patterns increase leaflet stress and strain, potentially causing fatigue and damage. This review article delves into the extent of THV deformation, its impact on leaflet function, hypoattenuating leaflet thickening, and structural valve degeneration. It provides an in-depth analysis of deformation specifics in different procedural contexts, including TAVR in native aortic stenosis, aortic and mitral valve-in-valve procedures, and redo-TAVR. Additionally, the review discusses strategies to mitigate THV deformation during the procedure, offering insights into potential solutions to these challenges.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA