Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(7)2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37050555

RESUMO

Colorimetric sensors are widely used because of their inherent advantages including accuracy, rapid response, ease-of-use, and low costs; however, they usually lack reusability, which precludes the continuous use of a single sensor. We have developed a threshold-responsive colorimetric system that enables repeated analyte measurements by a single colorimetric sensor. The threshold responsive algorithm automatically adjusts the sensor exposure time to the analyte and measurement frequency according to the sensor response. The system registers the colorimetric sensor signal change rate, prevents the colorimetric sensor from reaching saturation, and allows the sensor to fully regenerate before the next measurement is started. The system also addresses issues common to colorimetric sensors, including the response time and range of detection. We demonstrate the benefits and feasibility of this novel system, using colorimetric sensors for ammonia and carbon dioxide gases for continuous monitoring of up to (at least) 60 detection cycles without signs of analytical performance degradation of the sensors.

2.
Desalination ; 5502023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-37274380

RESUMO

Thin-film nanocomposite (TFN) membranes are emerging water-purification membranes that could provide enhanced water permeance with similar solute removal over traditional thin-film composite (TFC) membranes. However, the effects of nanofiller incorporation on active layer physico-chemical properties have not been comprehensively studied. Accordingly, we aimed to understand the correlation between nanofillers, active layer physico-chemical properties, and membrane performance by investigating whether observed performance differences between TFN and control TFC membranes correlated with observed differences in physico-chemical properties. The effects of nanofiller loading, surface area, and size on membrane performance, along with active layer physico-chemical properties, were characterized in TFN membranes incorporated with Linde Type A (LTA) zeolite and zeolitic imidazole framework-8 (ZIF-8). Results show that nanofiller incorporation up to ~0.15 wt% resulted in higher water permeance and unchanged salt rejection, above which salt rejection decreased 0.9-25.6% and 26.1-48.3% for LTA-TFN and ZIF-8-TFN membranes, respectively. Observed changes in active layer physico-chemical properties were generally unsubstantial and did not explain observed changes in TFN membrane performance. Therefore, increased water permeance in TFN membranes could be due to preferential water transport through porous structures of nanofillers or along polymer-nanofiller interfaces. These findings offer new insights into the development of high-performance TFN membranes for water/ion separations.

3.
Analyst ; 146(5): 1633-1641, 2021 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-33595556

RESUMO

Disorders in iron metabolism are endemic globally, affecting more than several hundred million individuals and often resulting in increased rates of mortality or general deterioration of quality of life. To both prevent and monitor treatment of iron related disorders, we present a point of care medical device which leverages a simple smartphone camera to measure total iron concentration from a finger-prick sample. The system consists of a smartphone and an in-house developed app, a 3D printed sensing chamber and a vertical flow membrane-based sensor strip designed to accommodate 50 µl of whole blood, filter out the cellular components and carry out a colorimetric chelation reaction producing a colour change which is detected by our smartphone device. The app's accuracy and precision were assessed via comparison of the mobile app's RGB output to a reference imaging software, ImageJ for the same colorimetric sensing strip. Correlation plots resulted in slopes of 0.99 and coefficient of determination (R2 = 0.99). The device was determined to have a signal to noise ratio >40 and a mean bias of 2% which both indicate high analytical accuracy and precision (in terms of RGB measurement). The smartphone device's iron concentration readout was then studied using an extensively validated laboratory developed test (LDT) for iron detection, which is an optimized spectrophotometry-based technique (this is considered the gold standard for iron quantification among LDTs). In comparison of the smartphone-based technique with the gold standard LDT, a calibration slope of 0.0004 au µg-1 dL-1, a correlation plot with slope of 1.09 and coefficient of determination (R2) of 0.96 and a mean bias of 5.3%, our device can accurately measure iron levels in blood. With detection times of five minutes, fingerpick sample and sensor cost less than 10 cents, the device shows great promise in being developed as the first ever commercial device for iron quantification in blood.


Assuntos
Ferro , Sistemas Automatizados de Assistência Junto ao Leito , Colorimetria , Humanos , Qualidade de Vida , Smartphone
4.
IEEE J Transl Eng Health Med ; 6: 2800610, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30112251

RESUMO

This paper introduces a wireless, solid-state, portable, and automated device capable of measuring the total ammonia [ammonia (NH3) and ammonium (NH4+)] levels of fluids, including biological samples. This device reliably measures the total ammonia of biological samples (e.g., urine) faster than the current ammonia quantification techniques. Medical professionals typically estimate NH4+ levels using error-prone indirect measurement techniques (i.e., urine anion gap), which are time-consuming and are seldom suitable for periodic measurements. Several instantaneous measurements of total ammonia levels in a patient urine could be utilized as an early warning for both acid-base and/or potassium disturbances. Given the device's operation mechanism, it is able to quantify the total ammonia concentration within a biological sample in only 5 s and can simultaneously transmit data to other devices via Bluetooth. The analytical operation demonstrated high sensitivity, high specificity, fast reversibility, rapid response time, and has enabled the accurate determination of total ammonia concentration in urine samples produced by subjects who had consumed diets of variable protein compositions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA