1.
Value Health ; 19(4): 494-504, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27325342

RESUMO

BACKGROUND: Mechanical circulatory support (MCS) is an option for the treatment of medically intractable end-stage heart failure. MCS therapy, however, is resource intensive. OBJECTIVE: The purpose of this report was to systematically review the MCS cost-effectiveness literature as it pertains to the treatment of adult patients in end-stage heart failure. METHODS: We conducted a systematic search and narrative review of available cost- effectiveness and cost-utility analyses of MCS in adult patients with end-stage heart failure. RESULTS: Eleven studies analyzing the cost-effectiveness or cost-utility of MCS were identified. Seven studies focused on bridge to transplantation, three studies focused on destination therapy, and one study presented analyses of both strategies. Two articles evaluated the cost-effectiveness of the HeartMate II (Thoratec Corp., Pleasanton, CA). Incremental cost-effectiveness ratios between MCS and medical management ranged between $85,025 and $200,166 for bridge to transplantation and between $87,622 and $1,257,946 for destination therapy (2012 Canadian dollars per quality-adjusted life-year). Sensitivity analyses indicated that improvements in survival and quality of life and reductions in device and initial hospital-stay costs may improve the cost-effectiveness of MCS. CONCLUSIONS: Current studies suggest that MCS is likely not cost-effective with reference to generally accepted or explicitly stated thresholds. Refined patient selection, complication rates, achieved quality of life, and device/surgical costs, however, could modify the cost-effectiveness of MCS.


Assuntos
Insuficiência Cardíaca/economia , Coração Auxiliar/economia , Análise Custo-Benefício , Insuficiência Cardíaca/terapia , Transplante de Coração , Humanos , Qualidade de Vida , Anos de Vida Ajustados por Qualidade de Vida , Avaliação da Tecnologia Biomédica
2.
Can Pharm J (Ott) ; 149(3): 113-5, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27212957
3.
Blood Press Monit ; 18(3): 167-72, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23635486

RESUMO

OBJECTIVE: Public-use blood pressure (BP) kiosks are commonly used, and yet their accuracy has been questioned on the basis of the results of the published validation studies. However, the adherence of these studies to established validation standards has not been studied. We carried out a systematic review of the published peer-reviewed literature on the validity of public-use BP kiosks to assess their adherence to validation standards. METHODS: With medical librarian assistance, the literature was searched systematically for studies claiming to validate kiosks up to June 2012. Studies were limited to English articles that studied adult patients and were excluded if they were carried out solely on pregnant women. Two authors independently compared the study methods with those recommended in the Association for the Advancement of Medical Instrumentation, British Hypertension Society and the European Society of Hypertension International Protocol validation standards. RESULTS: Nine studies were identified, of which only one came close to adhering to selected validation standard criteria, and found the device to be accurate. One study found device accuracy with poor adherence to standards, whereas the remaining seven found device inaccuracy with poor adherence to standards, therefore potentially reporting false conclusions. CONCLUSION: The majority of the reviewed studies validating public-use BP kiosks did not adhere to existing validation standards and therefore may have reported false conclusions. The one study that came close to following the validation standards found the device tested to be accurate. Readers must critically appraise the quality of validation studies published on these devices before interpreting their accuracy, and future studies should better adhere to existing validation standards to reduce the risk of reporting potentially false conclusions.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/instrumentação , Monitorização Ambulatorial da Pressão Arterial/métodos , Monitorização Ambulatorial da Pressão Arterial/normas , Cooperação do Paciente , Adulto , Ensaios Clínicos como Assunto , Reações Falso-Positivas , Feminino , Humanos , Masculino , Gravidez