Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur Radiol ; 25(4): 1208-17, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25424562

RESUMO

OBJECTIVE: The objective is to determine cardiac computed tomography (CCT) features capable of differentiating between bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV) in severe aortic stenosis (AS) patients with fused cusp and without elliptical-shaped systolic orifices. METHODS: We retrospectively enrolled 53 patients who had severe AS with fused cusps and without an elliptical-shaped systolic orifice on CCT and who had undergone surgery. CCT features were analyzed using: 1) aortic valve findings including cusp size, cusp area, opening shape, midline calcification, fusion length, calcium volume score, and calcium grade; 2) diameters of ascending and descending aorta, and main pulmonary artery; and 3) rheumatic mitral valve findings. The variables were evaluated using univariate and multivariate logistic regression analyses. RESULTS: At surgery, 19 patients had BAV and 34 had TAV. CCT features including uneven cusp size, uneven cusp area, round-shaped systolic orifice, longer cusp fusion, and dilatation of ascending aorta were significantly associated with BAV (P < 0.05). In particular, fusion length (OR, 1.76; P = 0.001), uneven cusp area (OR, 10.46; P = 0.012), and midline calcification (OR, 0.08; P = 0.013) were strongly associated with BAV. CONCLUSION: CCT provides diagnostic clues that helps differentiate between BAV with raphe and TAV with commissural fusion in patients with severe AS. KEY POINTS: • Accurate morphologic assessment of the aortic valve is important for treatment planning. • It is difficult to differentiate BAV from TAV with a fused cusp. • CCT provides diagnostic clues for the differentiation of BAV and TAV.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Valva Tricúspide/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
Eur Radiol ; 25(7): 2103-14, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25591751

RESUMO

OBJECTIVE: To characterize aortic valve dysfunction and ascending aorta dimensions according to bicuspid aortic valve (BAV) morphology using computed tomography (CT) and surgical findings. METHODS: We retrospectively enrolled 209 patients with BAVs who underwent transthoracic echocardiography (TTE) and CT. BAVs were classified as anterior-posterior (BAV-AP) or lateral (BAV-LA) orientation of the cusps and divided according to the presence (raphe+) or absence (raphe-) of a raphe. Ascending aortic dimensions were measured by CT at four levels. RESULTS: BAV-AP was present in 129 patients (61.7%) and raphe+ in 120 (57.4%). Sixty-nine patients (33.0%) had aortic regurgitation (AR), 70 (33.5%) had aortic stenosis (AS), and 58 (27.8%) had combined AS and AR. AR was more common in patients with BAV-AP and raphe+; AS was more common with BAV-LA and raphe-.Annulus/body surface area and tubular portion/body surface area diameters in patients with BAV-AP (17.1 ± 2.3 mm/m(2) and 24.2 ± 5.3 mm/m(2), respectively) and raphe+ (17.3 ± 2.2 mm/m(2) and 24.2 ± 5.5 mm/m(2), respectively) were significantly different from those with BAV-LA (15.8 ± 1.9 mm/m(2) and 26.4 ± 5.5 mm/m(2), respectively) and raphe- (15.7 ± 1.9 mm/m(2) and 26.2 ± 5.4 mm/m(2), respectively). CONCLUSION: The morphological characteristics of BAV might be associated with the type of valvular dysfunction, and degree and location of an ascending aorta dilatation. KEY POINTS: • The BAV-AP type had more frequent aortic regurgitation, raphe, and a larger aortic annulus. • BAV without raphe had more frequent aortic stenosis and mid-ascending aorta dilatation. • CT allows assessment of the morphological characteristics of BAV and associated aortopathy.


Assuntos
Aorta/patologia , Insuficiência da Valva Aórtica/patologia , Estenose da Valva Aórtica/patologia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/patologia , Aorta/fisiopatologia , Valva Aórtica/patologia , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Superfície Corporal , Dilatação Patológica/patologia , Dilatação Patológica/fisiopatologia , Ecocardiografia , Eletrocardiografia , Feminino , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
3.
AJR Am J Roentgenol ; 203(6): W605-13, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25415725

RESUMO

OBJECTIVE: The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. SUBJECTS AND METHODS: One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. RESULTS: The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. CONCLUSION: Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.


Assuntos
Estenose Coronária/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Eur Radiol ; 21(1): 26-35, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20658242

RESUMO

OBJECTIVE: To evaluate the feasibility and diagnostic accuracy of adenosine-stress dual-energy computed tomography (DECT) for detecting haemodynamically significant stenosis causing reversible myocardial perfusion defect (PD) compared with stress perfusion magnetic resonance imaging (SP-MRI) and conventional coronary angiography (CCA). METHODS: Fifty patients with known coronary artery disease (CAD) detected by dual-source CT (DSCT) were investigated by contrast-enhanced, stress DECT with high- and low-energy x-ray spectra settings during adenosine infusion. A colour-coded iodine map was used for evaluation of myocardial PDs compared with rest DSCT perfusion images. Reversible myocardial PDs according to the stress DECT/rest DSCT were compared with SP-MRI on a segmental basis and CCA on a vascular territorial basis. RESULTS: A total of 697 myocardial segments and 123 vascular territories of 41 patients were analysed. Three hundred one segments and 72 vascular territories in 38 patients showed reversible PDs on stress DECT. Stress DECT had 89% sensitivity, 78% specificity and 82% accuracy for detecting segments with reversible PDs seen on SP-MRI (n=28). Compared with CCA (n=41), stress DECT had 89% sensitivity, 76% specificity and 83% accuracy for the detection of vascular territories with reversible myocardial PDs that had haemodynamically relevant CAD. CONCLUSION: Adenosine stress DECT can identify stress-induced myocardial PD in patients with CAD.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Ecocardiografia sob Estresse , Coração/diagnóstico por imagem , Angiografia por Ressonância Magnética , Tomografia Computadorizada por Raios X , Adenosina , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Int J Cardiovasc Imaging ; 31 Suppl 1: 103-14, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25011534

RESUMO

This study aimed to evaluate the utility of dual-source computed tomography (DSCT) for quantification of the mitral valve area (MVA) in patients with atrial fibrillation (AF) and mitral stenosis (MS) and to compare the results of DSCT with those of cardiovascular magnetic resonance (CMR) and transthoracic echocardiography (TTE). One hundred-two patients with AF and MS who had undergone electrocardiography-gated DSCT, TTE and CMR prior to operation were retrospectively enrolled. The MVA was planimetrically determined by DSCT, CMR, and TTE, as well as by Doppler TTE using the pressure half-time method (TTE-PHT). Agreement, relationship between measurements, and the highest accuracy were evaluated using Bland-Altman, Pearson correlation, and receiver operating characteristic analyses. The MVA on DSCT (mean, 1.27 ± 0.27 cm(2)) was significantly larger than that on CMR (1.15 ± 0.28 cm(2), P < 0.05), TTE-planimetry and TTE-PHT (1.16 ± 0.28 and 1.07 ± 0.30 cm(2), respectively; P < 0.05). TTE-planimetry had better correlation with planimetry on DSCT and CMR (r = 0.65 and 0.67, respectively; P < 0.05) than TTE-PHT (r = 0.51 and 0.55, respectively; P < 0.05). Using an MVA of 1.0 cm(2) on TTE-planimetry and TTE-PHT as the reference, the optimal thresholds for detecting severe MS on DSCT was 1.19 cm(2). The planimetry of the MVA measured by DSCT may be a reliable, alternative method for the quantification of MS in patients with AF.


Assuntos
Fibrilação Atrial/diagnóstico , Ecocardiografia , Imageamento por Ressonância Magnética , Estenose da Valva Mitral/diagnóstico , Valva Mitral , Tomografia Computadorizada por Raios X , Adulto , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/patologia , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/patologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/patologia , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos
6.
Korean J Radiol ; 11(5): 514-21, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20808694

RESUMO

OBJECTIVE: To evaluate the depiction rate and morphologic features of myocardial bridging (MB) of the left anterior descending coronary artery (LAD) using dual-source CT (DSCT). MATERIALS AND METHODS: CT scans from a total of 1,353 patients who underwent DSCT were reviewed retrospectively for LAD-MB. Seventy-eight patients were excluded due to poor image quality or poor enhancement of the coronary artery. The length and depth of the MB were analyzed and classified as superficial or deep with respect to the depth ( 1 mm) of the LAD tunneled segment. Superficial MB was subdivided into complete or incomplete types according to full or partial encasement of the myocardium. RESULTS: Of the 1,275 patients included in this study, 557 cases of MB were found from 536 patients (42%). Superficial MB was observed in 368 of 557 (66%) cases, and deep MB was seen in 189 of 557 (34%) cases. Superficial MB showed 2 types: complete (128 of 368, 35%) and incomplete (240 of 368, 65%). The mean length of a tunneled segment for superficial MB was 16.4 +/- 8.6 mm. The mean length and depth of a tunneled segment for deep MB were 27.6 +/- 12.8 mm and 3.0 +/- 1.4 mm, respectively. The incidence of atherosclerotic plaques in a 2-cm-long segment proximal to MB was 16%. CONCLUSION: The depiction rate of LAD-MB using DSCT in a large series of patients was 42%, with two-thirds of MB segments being the superficial type.


Assuntos
Angiografia Coronária/métodos , Ponte Miocárdica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA