Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 95(19): 7693-7701, 2023 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-37145768

RESUMO

Post-arthroplasty periprosthetic joint infection (PJI) is a serious ailment that can be difficult to diagnose. Herein, we developed a novel integrated microfluidic system (IMS) capable of detecting two common PJI biomarkers, alpha defensin human neutrophil peptide 1 (HNP-1) and C-reactive protein (CRP), from synovial fluid (SF). A magnetic bead-based one-aptamer-one-antibody assay was carried out automatically within 45 min on a single chip for simultaneous detection of both biomarkers at concentration ranges of 0.01-50 (HNP-1) and 1-100 (CRP) mg/L. It is the first report for utilizing these two biomarkers as targets to establish the new one-aptamer-one-antibody assay to detect PJI on-chip, and the aptamers demonstrated high specificity to their SF targets. As 20 clinical samples were correctly diagnosed with our IMS (verified by a common gold standard kit), it could serve as a promising tool for PJI diagnostics.


Assuntos
Artrite Infecciosa , Infecções Relacionadas à Prótese , Humanos , Líquido Sinovial/química , Infecções Relacionadas à Prótese/diagnóstico , Microfluídica , Sensibilidade e Especificidade , Biomarcadores/metabolismo , Proteína C-Reativa/análise , Artrite Infecciosa/diagnóstico , Artrite Infecciosa/metabolismo
2.
Biosens Bioelectron ; 229: 115120, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36963324

RESUMO

The diagnosis of periprosthetic joint infection (PJI) remains a labor-intensive and challenging issue, with life-threatening complications associated with misdiagnoses. Superior diagnostic approaches are therefore urgently needed, and synovial biomarkers are gaining substantial attention in this capacity. A new aptamer-based sandwich assay was developed where the aptamer probes specific to one such biomarker, alpha-defensin human neutrophil protein 1 (HNP 1), was integrated herein into a new microfluidic platform. The magnetic beads coated with the primary aptamer probe were able to bind the target protein with high affinity and high specificity in synovial fluid and a fluorescent-labelled secondary aptamer were further used to quantify HNP 1 in a sandwich approach. Up to four clinical samples with low volume (∼50 µL each) in a much faster assay including detection within <60 min with 100% accuracy (with totally 13 clinical samples without the need of sample pretreatment) through the use of the aptamer-based sandwich assay were automatically detected on a single chip. The wide dynamic range of this compact device, 0.5-100 mg/L, highlights its utility for future PJI diagnostics in the clinic.


Assuntos
Artrite Infecciosa , Técnicas Biossensoriais , alfa-Defensinas , Humanos , Microfluídica , Neutrófilos , Biomarcadores , Oligonucleotídeos , Líquido Sinovial , Artrite Infecciosa/diagnóstico , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA