Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int J Mol Sci ; 25(11)2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38892113

RESUMO

Wet age-related macular degeneration (wet AMD) is a primary contributor to visual impairment and severe vision loss globally, but the prevailing treatments are often unsatisfactory. The development of conventional treatment strategies has largely been based on the understanding that the angiogenic switch of endothelial cells (ECs) is mainly dictated by angiogenic growth factors. Even though treatments targeting vascular endothelial growth factor (VEGF), like ranibizumab, are widely administered, more than half of patients still exhibit inadequate or null responses, suggesting the involvement of other pathogenic mechanisms. With advances in research in recent years, it has become well recognized that EC metabolic regulation plays an active rather than merely passive responsive role in angiogenesis. Disturbances of these metabolic pathways may lead to excessive neovascularization in angiogenic diseases such as wet AMD, therefore targeted modulation of EC metabolism represents a promising therapeutic strategy for wet AMD. In this review, we comprehensively discuss the potential applications of EC metabolic regulation in wet AMD treatment from multiple perspectives, including the involvement of ECs in wet AMD pathogenesis, the major endothelial metabolic pathways, and novel therapeutic approaches targeting metabolism for wet AMD.


Assuntos
Células Endoteliais , Degeneração Macular Exsudativa , Humanos , Células Endoteliais/metabolismo , Degeneração Macular Exsudativa/metabolismo , Degeneração Macular Exsudativa/tratamento farmacológico , Animais , Fator A de Crescimento do Endotélio Vascular/metabolismo , Ranibizumab/uso terapêutico , Inibidores da Angiogênese/uso terapêutico , Inibidores da Angiogênese/farmacologia , Redes e Vias Metabólicas , Neovascularização Patológica/metabolismo
2.
Mikrochim Acta ; 190(2): 56, 2023 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-36645516

RESUMO

Ultrabright green-emissive AIE nanoparticles (AIENPs) were used as signal-amplification probes to enhance the detectability of lateral flow immunoassay (LFIA). The detection performances of the green-emissive AIENP probes in both sandwich and competitive LFIA formats were systematically evaluated. Benefiting from its remarkable fluorescent brightness, the developed AIENP-LFIA showed versatile applicability for the detection of small molecules and macromolecules by using ochratoxin A (OTA) and procalcitonin (PCT) as model analytes, respectively. Under the optimum conditions, the detection limits (LODs) of the fabricated AIENP-LFIA for OTA and PCT were 0.043 ng mL-1 and 0.019 ng mL-1, respectively. These LOD values are significantly lower than those of conventional LFIA methods using gold nanoparticles as signal reporters. In addition, we demonstrated the practical application potential of AIENP-LFIA for the detection of OTA in real maize samples and PCT in real serum samples. These results indicated that the ultrabright green-emissive AIENPs were promising as signal output materials for building high-performance LFIA platform and broadening the application scenarios of LFIA.


Assuntos
Nanopartículas Metálicas , Ouro , Imunoensaio/métodos
3.
J Dairy Sci ; 105(6): 4938-4945, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35465994

RESUMO

Staphylococcal enterotoxin A (SEA) is an important biotoxin, produced by Staphylococcus aureus under appropriate conditions, and often contaminates milk and dairy products. Herein, an anti-SEA monoclonal antibody (anti-SEA mAb) was prepared by injecting the SEA protein in BALB/c mice, and a novel immunochromatographic assay (ICA) was developed for the rapid and sensitive determination of SEA in pasteurized milk by using highly luminescent quantum dot beads (QB) as signal amplification probe. Given the 1020-fold enhancement in the photoluminescence intensity of QB to the original quantum dot, the proposed QB-ICA exhibits high sensitivity for SEA determination in real milk samples with a limit of detection of 1.89 ng/mL, and shows good dynamic linearity for SEA quantitative detection from 2 to 150 ng/mL within 15 min of test time. The proposed QB-ICA also shows good selectivity to SEA detection with a negligible cross-reaction to common analogs, including staphylococcal enterotoxins B, C, D, and E. In addition, the accuracy and precision of QB-ICA were assessed by analyzing SEA-fortified milk samples. The average recoveries of intra- and interassays range from 85.5 to 128.1%, and the coefficients of variation range from 4.6 to 14.2%, indicating an acceptable accuracy for the quantitative detection of SEA in real milk samples. In summary, this work provides a powerful and rapid analysis tool for the sensitive monitoring of SEA contamination in pasteurized milk samples.


Assuntos
Pontos Quânticos , Animais , Cromatografia de Afinidade/métodos , Cromatografia de Afinidade/veterinária , Enterotoxinas/análise , Imunoensaio/veterinária , Camundongos , Leite/química , Pontos Quânticos/química
4.
J Dairy Sci ; 103(8): 6940-6949, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32475677

RESUMO

Escherichia coli O157:H7 is a common harmful foodborne pathogen that can cause severe diseases at low infectious doses. Traditional lateral flow immunoassay (LFIA) for the rapid screening of E. coli O157:H7 in food suffers from low sensitivity due to its dependence on 20- to 40-nm gold nanoparticles (AuNP) with insufficient brightness as labels. To address this issue, we reported for the first time the successful synthesis of gold superparticles (GSP) by encapsulating numerous small AuNP into a polymer nanobead using an evaporation-induced self-assembly method. Results indicated that the resultant GSP exhibited remarkably enhanced absorbance compared with the most widely used 40 nm AuNP in LFIA. In addition, the absorbance of GSP could be easily tuned by varying GSP sizes. Under optimized conditions, we achieved a rapid and sensitive determination of E. coli O157:H7 in milk with a detection limit of 5.95 × 102 cfu/mL when using the GSP with a size of 342 nm as LFIA signal reporters, exhibiting improvement of approximately 32-fold relative to the conventional 40 nm AuNP-LFIA method. We further demonstrated the selectivity, accuracy, reliability, and practicality of the proposed GSP-LFIA strip. In summary, this work offers a new strategy for improving LFIA sensitivity using assembled GSP as markers and demonstrates huge potential in rapidly and sensitively detecting foodborne pathogens.


Assuntos
Escherichia coli O157/isolamento & purificação , Ouro , Imunoensaio/veterinária , Nanopartículas Metálicas/química , Leite/microbiologia , Animais , Microbiologia de Alimentos , Imunoensaio/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Mikrochim Acta ; 187(12): 640, 2020 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-33151410

RESUMO

Gold nanoparticle-decorated metal organic frameworks (MOF@AuNPs) with significantly enhanced color signal intensity were synthesized through in situ growth of AuNPs on the MOF skeleton. The resultant MOF@AuNP nanocomposites were characterized with 16.7-fold higher absorbance than conventional 40 nm AuNPs (AuNP40). Thus, for the first time, we applied it as a signal amplification label to improve the immunochromatographic assay (ICA) of human chorionic gonadotropin (HCG). The detection limit of our enhanced ICA was 1.69 mIU/mL, which is ca. 10.6-fold improvement in sensitivity compared to traditional AuNP40-ICA. The recoveries of this MOF@AuNPs-ICA ranged from 86.03 to 119.22%, with coefficients of variation of 3.05 to 13.74%. The reliability and practicability were further validated by the clinically used chemiluminescence immunoassay method. Given their excellent signal amplification ability, the proposed MOF@AuNPs could serve as an ideal ICA label for rapid and sensitive detection of disease biomarkers. Graphical abstract.


Assuntos
Gonadotropina Coriônica/sangue , Cromatografia de Afinidade/métodos , Ouro/química , Nanopartículas Metálicas/química , Estruturas Metalorgânicas/química , Humanos , Limite de Detecção , Reprodutibilidade dos Testes
6.
J Dairy Sci ; 102(3): 1997-2007, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30612795

RESUMO

We applied urease-induced silver metallization on the surface of gold nanorods (AuNR) to improve colorimetric ELISA for the rapid and sensitive detection of Salmonella enterica Choleraesuis. To this end, we introduced a biotin-streptavidin system as a bridge to determine the correlation between urease and S. enterica Choleraesuis concentrations. The captured urease can catalyze the hydrolysis of urea into carbon dioxide and ammonia, and the generated ammonia can then induce the deposition of silver shell on the surface of AuNR in the presence of silver nitrate and glucose. With the decreased aspect ratio (length divided by width) of AuNR, a multicolor change of AuNR solution and a significant blue shift in the longitudinal localized surface plasmon resonance absorption peak (Δλmax) of AuNR were obtained at the target concentrations of 1.21 × 101 to 1.21 × 108 cfu/mL. Consequently, the detection limits of our proposed colorimetric ELISA were as low as 1.21 × 102 cfu/mL for qualitative detection with naked eyes, and 1.21 × 101 cfu/mL for quantitative detection, in which changes in Δλmax of AuNR were recorded with a microplate reader. These values were at least 2 to 3 orders of magnitude lower than those obtained with conventional horseradish peroxidase-based ELISA. The analytical performance of our developed colorimetric ELISA in terms of selectivity, accuracy, reliability, and practicability were investigated by analyzing S. enterica Choleraesuis-spiked pasteurized whole milk samples.


Assuntos
Colorimetria/veterinária , Ensaio de Imunoadsorção Enzimática/veterinária , Ouro/química , Leite/microbiologia , Nanotubos/química , Salmonella enterica/isolamento & purificação , Urease/química , Animais , Colorimetria/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Microbiologia de Alimentos/métodos
7.
Biosens Bioelectron ; 261: 116458, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38852321

RESUMO

Herein, a colorimetric-fluorescent hybrid bifunctional nanobead with Janus structure (J-cf-HBN) was synthesized via one-pot microemulsification. Oleylamine-coated AuNPs and aggregation-induced emission luminogens (AIEgens) were suggested as building blocks to obtain high-performance colorimetric-fluorescent signals. The as-prepared J-cf-HBNs were used as a signal amplification probe to construct an immunochromatographic assay (J-cf-HBNs-ICA) platform for the ultrasensitive detection of staphylococcal enterotoxin B (SEB) in milk samples. Owing to the rational spatial distribution of AuNPs and AIEgens, the J-cf-HBNs present a highly retained photoluminescence and enhanced colorimetric signals. Combined with a pair of highly affinitive anti-SEB antibodies, the J-cf-HBN-ICA platform enabled the fast naked-eye visualization and fluorescent quantitative detection of SEB in various milk matrices. Given the advantages of the dual-mode high-performance J-cf-HBNs, the proposed strip achieved a high sensitivity for SEB qualitative determination with a visual limit of detection (LOD) of 1.56 ng mL-1 and exhibited ultrasensitivity for SEB quantitative detection with a LOD of 0.09 ng mL-1, which is 139-fold lower than that of ELISA using same antibodies. In conclusion, this work provides new insights into the construction of multimode immunochromatographic methods for food safety detection in the field.


Assuntos
Técnicas Biossensoriais , Colorimetria , Enterotoxinas , Ouro , Limite de Detecção , Nanopartículas Metálicas , Leite , Leite/química , Enterotoxinas/análise , Enterotoxinas/imunologia , Enterotoxinas/isolamento & purificação , Animais , Técnicas Biossensoriais/métodos , Colorimetria/métodos , Ouro/química , Nanopartículas Metálicas/química , Corantes Fluorescentes/química , Contaminação de Alimentos/análise , Cromatografia de Afinidade/métodos , Imunoensaio/métodos
8.
Adv Mater ; 36(27): e2313381, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38647215

RESUMO

Aggregation-induced emission luminogen (AIEgen)-functionalized organic-inorganic hybrid nanoparticles (OINPs) are an emerging category of multifunctional nanomaterials with vast potential applications. The spatial arrangement and positioning of AIEgens and inorganic compounds in AIEgen-functionalized OINPs determine the structures, properties, and functionalities of the self-assembled nanomaterials. In this work, a facile and general emulsion self-assembly tactic for synthesizing well-defined AIEgen-functionalized OINPs is proposed by coassembling alkane chain-functionalized inorganic nanoparticles with hydrophobic organic AIEgens. As a proof of concept, the self-assembly and structural evolution of plasmonic-fluorescent hybrid nanoparticles (PFNPs) from concentric circle to core shell and then to Janus structures is demonstrated by using alkane chain-modified AuNPs and AIEgens as building blocks. The spatial position of AuNPs in the signal nanocomposite is controlled by varying the alkane ligand length and density on the AuNP surface. The mechanism behind the formation of various PFNP nanostructures is also elucidated through experiments and theoretical simulation. The obtained PFNPs with diverse structures exhibit spatially tunable optical and photothermal properties for advanced applications in multicolor and multimode immunolabeling and photothermal sterilization. This work presents an innovative synthetic approach of constructing AIEgen-functionalized OINPs with diverse structures, compositions, and functionalities, thereby championing the progressive development of these OINPs.

9.
Food Chem ; 447: 138997, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38513493

RESUMO

Herein we developed a multicolor lateral flow immunoassay (LFIA) test strip for rapid and simultaneous quantitative detection of aflatoxin B1 (AFB1) and zearalenone (ZEN). Three differently colored aggregation-induced emission nanoparticles (AIENPs) were designed as LFIA signal tags, with red and green AIENPs for targeting AFB1 and ZEN at the test line, and yellow AIENPs for indicating the validity of the test strip at the control (C) line. After surface functionalization with antibodies, the developed AIENP-based multicolor LFIA allows simultaneous and accurate quantification of AFB1 and ZEN using an independent C-line assisted ratiometric signal output strategy. The detection limits of AFB1 and ZEN were 6.12 and 26 pg/mL, respectively. The potential of this method for real-world applications was well demonstrated in corn and wheat. Overall, this multicolor LFIA shows great potential for field screening of multiple mycotoxins and can be extended to rapid and simultaneous monitoring of other small molecule targets.


Assuntos
Nanopartículas Metálicas , Micotoxinas , Zearalenona , Zearalenona/análise , Aflatoxina B1/análise , Anticorpos Monoclonais , Micotoxinas/análise , Imunoensaio/métodos , Limite de Detecção , Contaminação de Alimentos/análise
10.
Biomed Pharmacother ; 175: 116776, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38788546

RESUMO

Choroidal neovascularization (CNV), characterized as a prominent feature of wet age-related macular degeneration (AMD), is a primary contributor to visual impairment and severe vision loss globally, while the prevailing treatments are often unsatisfactory. The development of conventional treatment strategies has largely been based on the understanding that the angiogenic switch of endothelial cells is dictated by angiogenic growth factors alone. Even though treatments targeting vascular endothelial growth factor (VEGF), like Ranibizumab, are widely administered, more than half of the patients still exhibit inadequate or null responses, emphasizing the imperative need for solutions to this problem. Here, aiming to explore therapeutic strategies from a novel perspective of endothelial cell metabolism, a biocompatible nanomedicine delivery system is constructed by loading RGD peptide-modified liposomes with 2-deoxy-D-glucose (RGD@LP-2-DG). RGD@LP-2-DG displayed good targeting performance towards endothelial cells and excellent in vitro and in vivo inhibitory effects on neovascularization were demonstrated. Moreover, our mechanistic studies revealed that 2-DG interfered with N-glycosylation, leading to the inhibition of vascular endothelial growth factor receptor 2 (VEGFR2) and its downstream signaling. Notably, the remarkable inhibitory effect on neovascularization and biocompatibility of RGD@LP-2-DG render it a highly promising and clinically translatable therapeutic candidate for the treatment of wet AMD and other angiogenic diseases, particularly in patients who are unresponsive to currently available treatments.


Assuntos
Neovascularização de Coroide , Desoxiglucose , Lipossomos , Nanomedicina , Oligopeptídeos , Receptor 2 de Fatores de Crescimento do Endotélio Vascular , Degeneração Macular Exsudativa , Oligopeptídeos/química , Animais , Humanos , Nanomedicina/métodos , Neovascularização de Coroide/tratamento farmacológico , Neovascularização de Coroide/patologia , Neovascularização de Coroide/metabolismo , Degeneração Macular Exsudativa/tratamento farmacológico , Degeneração Macular Exsudativa/metabolismo , Desoxiglucose/farmacologia , Desoxiglucose/administração & dosagem , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/metabolismo , Células Endoteliais da Veia Umbilical Humana/metabolismo , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Camundongos , Camundongos Endogâmicos C57BL , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/metabolismo
11.
Food Chem ; 412: 135580, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-36736185

RESUMO

Herein, we report a novel aggregation-induced emission nanoparticles (AIENPs)-based immunochromatography assay (ICA) platform to detect ochratoxin A (OTA) using orange-yellow-emitting AIENPs as fluorescent nanoprobes. Immunochromatographic strip is used for the quantitative detection of OTA in crop matrix using AIENPs coupled with anti-OTA ascites. Under optimal conditions, AIENPs-ICA exhibits stronger signal output capacity and higher sensitivity than traditional gold nanoparticles-based ICA. The half-maximal inhibitory concentration is as low as 0.149 ng mL-1, and the limit detection is 0.042 ng mL-1 at 10 % competitive inhibition concentration. The average recovery of AIENPs-ICA ranges from 82.60 % to 113.14 % with the coefficient of variation ranging from 1.26 % to 11.57 %, proving the proposed method possesses good reliability and reproducibility. Moreover, the developed AIENPs-ICA exhibits negligible cross-reactions with other mycotoxins. We believe the presented AIENPs-ICA platform holds promising potential as a powerful tool for on-site detection of OTA and other molecules detection in food samples.


Assuntos
Nanopartículas Metálicas , Ocratoxinas , Ouro/química , Zea mays/química , Reprodutibilidade dos Testes , Cromatografia de Afinidade/métodos , Limite de Detecção , Nanopartículas Metálicas/química , Ocratoxinas/análise
12.
Toxins (Basel) ; 15(2)2023 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-36828428

RESUMO

Staphylococcal enterotoxin A (SEA) has presented enormous difficulties in dairy food safety and the sensitive detection of SEA provides opportunities for effective food safety controls and staphylococcal food poisoning tracebacks. Herein, a novel aggregation-induced emission (AIE)-based sandwich lateral flow immunoassay (LFIA) was introduced to detect SEA by using red-emissive AIE nanoparticles (AIENPs) as the fluorescent nanoprobe. The nanoprobe was constructed by directly immobilising antibodies on boronate-tagged AIENPs (PBA-AIENPs) via a boronate affinity reaction, which exhibited a high SEA-specific affinity and remarkable fluorescent performance. Under optimal conditions, the ultrasensitive detection of SEA in pasteurised milk was achieved within 20 min with a limit of detection of 0.04 ng mL-1. The average recoveries of the PBA-AIENP-LFIA ranged from 91.3% to 117.6% and the coefficient of variation was below 15%. It was also demonstrated that the PBA-AIENP-LFIA had an excellent selectivity against other SE serotypes. Taking advantage of the excellent sensitivity of this approach, real chicken and salad samples were further analysed, with a high versatility and accuracy. The proposed PBA-AIENP-LFIA platform shows promise as a potent tool for the identification of additional compounds in food samples as well as an ideal test method for on-site detections.


Assuntos
Nanopartículas Metálicas , Nanopartículas , Animais , Enterotoxinas/análise , Imunoensaio/métodos , Leite/química , Limite de Detecção , Ouro
13.
Biosensors (Basel) ; 13(4)2023 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37185496

RESUMO

Hg2+ contamination in sewage can accumulate in the human body through the food chains and cause health problems. Herein, a novel aggregation-induced emission luminogen (AIEgen)-encapsulated hydrogel probe for ultrasensitive detection of Hg2+ was developed by integrating hydrophobic AIEgens into hydrophilic hydrogels. The working mechanism of the multi-fluorophore AIEgens (TPE-RB) is based on the dark through-bond energy transfer strategy, by which the energy of the dark tetraphenylethene (TPE) derivative is completely transferred to the rhodamine-B derivative (RB), thus resulting in intense photoluminescent intensity. The spatial networks of the supporting hydrogels further provide fixing sites for the hydrophobic AIEgens to enlarge accessible reaction surface for hydrosoluble Hg2+, as well create a confined reaction space to facilitate the interaction between the AIEgens and the Hg2+. In addition, the abundant hydrogen bonds of hydrogels further promote the Hg2+ adsorption, which significantly improves the sensitivity. The integrated TPE-RB-encapsulated hydrogels (TR hydrogels) present excellent specificity, accuracy and precision in Hg2+ detection in real-world water samples, with a 4-fold higher sensitivity compared to that of pure AIEgen probes. The as-developed TR hydrogel-based chemosensor holds promising potential as a robust, fast and effective bifunctional platform for the sensitive detection of Hg2+.


Assuntos
Mercúrio , Humanos , Hidrogéis , Corantes Fluorescentes/química , Íons , Adsorção
14.
Anal Chim Acta ; 1247: 340869, 2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36781245

RESUMO

Organic fluorescein dye-embedded fluorescent microspheres (FMs) are currently the most established commercially fluorescent markers, and they have been widely used to improve the sensitivity of immunochromatography assay (ICA). However, these FMs have natural defects, such as the aggregation-caused quenching effect and small Stokes shift, which are not conducive to improving the detection performance of ICA. Herein, two green emitted FMs, namely aggregation-induced emission FMs (AIEFMs) and fluorescein isothiocyanate FMs (FITCFMs), were prepared by swelling the AIE luminogens and FITC dyes into the carboxyl group-modified polystyrene microspheres. The average diameters of AIEFMs and FITCFMs were 350 and 450 nm, respectively. Compared with FITCFMs, the AIEFMs exhibited stronger fluorescence intensity and a larger Stokes shift. These two FMs were used as the labeling markers of ICA for procalcitonin (PCT) detection with the sandwich format. Among them, AIEFM-ICA showed dynamic linear detection of PCT from 7.6 pg mL-1 to 125 ng mL-1 with the limit of detection (LOD) at 3.8 pg mL-1. These values were remarkably superior to those of FITCFM-ICA (linear range from 61 pg mL-1 to 62.5 ng mL-1 and LOD value at 60 pg mL-1). Furthermore, the average recoveries of the intra- and inter-assays of AIEFM-ICA ranged from 86% to 112%, with coefficients of variation ranging from 1.2% to 8.8%, indicating accuracy and precision for PCT quantitative detection. Additionally, the reliability of the developed AIEFM-ICA was further assessed by analyzing 30 real serum samples from systemic inflammatory response by infectious diseases, and the results showed good agreement with the chemiluminescence immunoassay. In conclusion, compared with traditional FITCFMs, green emitted AIEFMs as a novel fluorescent label, exhibits greater potential to enhance the detection performance of the ICA platform.


Assuntos
Corantes , Luminescência , Microesferas , Reprodutibilidade dos Testes , Cromatografia de Afinidade/métodos , Fluoresceínas , Imunoensaio/métodos
15.
Toxins (Basel) ; 15(1)2023 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-36668898

RESUMO

Lateral flow immunoassay (LFIA) based on fluorescent microbeads has attracted much attention for its use in rapid and accurate food safety monitoring. However, conventional fluorescent microbeads are limited by the aggregation-caused quenching effect of the loaded fluorophores, thus resulting in low signal intensity and insufficient sensitivity of fluorescent LFIA. In this study, a green-emitting fluorophore with an aggregation-induced emission (AIE) characteristic was encapsulated in polymer nanoparticles via an emulsification technique to form ultrabright fluorescent microbeads (denoted as AIEMBs). The prepared AIEMBs were then applied in a competitive LFIA (AIE-LFIA) as signal reporters for the rapid and highly sensitive screening of fumonisin B1 (FB1) in real corn samples. High sensitivity with a detection limit of 0.024 ng/mL for FB1 was achieved by the developed AIE-LFIA. Excellent selectivity, good accuracy, and high reliability of the AIE-LFIA were demonstrated, indicating a promising platform for FB1 screening.


Assuntos
Ouro , Nanopartículas Metálicas , Reprodutibilidade dos Testes , Microesferas , Imunoensaio/métodos , Limite de Detecção
16.
J Agric Food Chem ; 71(10): 4408-4416, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36866978

RESUMO

Highly luminescent nanospheres have been demonstrated in enhancing the sensitivity of lateral flow immunoassay (LFIA) due to their loading numerous luminescent dyes. However, the photoluminescence intensities of existing luminescent nanospheres are limited due to the aggregation-caused quenching effect. Herein, highly luminescent aggregation-induced emission luminogens embedded nanospheres (AIENPs) with red emission were introduced as signal amplification probes of LFIA for quantitative detection of zearalenone (ZEN). Optical properties of red-emitted AIENPs were compared with time-resolved dye-embedded nanoparticles (TRNPs). Results showed that red-emitted AIENPs have stronger photoluminescence intensity on the nitrocellulose membrane and superior environmental tolerance. Additionally, we benchmarked the performance of AIENP-LFIA against TRNP-LFIA using the same set of antibodies, materials, and strip readers. Results showed that AIENP-LFIA exhibits good dynamic linearity with the ZEN concentration from 0.195 to 6.25 ng/mL, with half competitive inhibitory concentration (IC50) and detection of limit (LOD) at 0.78 and 0.11 ng/mL, respectively. The IC50 and LOD are 2.07- and 2.36-fold lower than those of TRNP-LFIA. Encouragingly, the precision, accuracy, specificity, practicality, and reliability of this AIENP-LFIA for ZEN quantitation were further characterized. The results verified that the AIENP-LFIA has good practicability for the rapid, sensitive, specific, and accurate quantitative detection of ZEN in corn samples.


Assuntos
Nanopartículas Metálicas , Nanosferas , Zearalenona , Zearalenona/análise , Luminescência , Contaminação de Alimentos/análise , Reprodutibilidade dos Testes , Imunoensaio/métodos , Limite de Detecção , Nanopartículas Metálicas/química
17.
ACS Nano ; 17(15): 14347-14405, 2023 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-37486125

RESUMO

Light has profoundly impacted modern medicine and healthcare, with numerous luminescent agents and imaging techniques currently being used to assess health and treat diseases. As an emerging concept in luminescence, aggregation-induced emission (AIE) has shown great potential in biological applications due to its advantages in terms of brightness, biocompatibility, photostability, and positive correlation with concentration. This review provides a comprehensive summary of AIE luminogens applied in imaging of biological structure and dynamic physiological processes, disease diagnosis and treatment, and detection and monitoring of specific analytes, followed by representative works. Discussions on critical issues and perspectives on future directions are also included. This review aims to stimulate the interest of researchers from different fields, including chemistry, biology, materials science, medicine, etc., thus promoting the development of AIE in the fields of life and health.


Assuntos
Corantes Fluorescentes , Substâncias Luminescentes , Corantes Fluorescentes/química , Luminescência , Diagnóstico por Imagem , Atenção à Saúde
18.
Theranostics ; 12(2): 574-602, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34976202

RESUMO

Lateral flow immunoassay (LFIA) with gold nanoparticles (AuNPs) as signal reporters is a popular point-of-care diagnostic technique. However, given the weak absorbance of traditional 20-40 nm spherical AuNPs, their sensitivity is low, which greatly limits the wide application of AuNP-based LFIA. With the rapid advances in materials science and nanotechnology, the synthesis of noble metal nanoparticles (NMNPs) has enhanced physicochemical properties such as optical, plasmonic, catalytic, and multifunctional activity by simply engineering their physical parameters, including the size, shape, composition, and external structure. Using these engineered NMNPs as an alternative to traditional AuNPs, the sensitivity of LFIA has been significantly improved, thereby greatly expanding the working range and application scenarios of LFIA, particularly in trace analysis. Therefore, in this review, we will focus on the design of engineered NMNPs and their demonstration in improving LFIA. We highlight the strategies available for tailoring NMNP designs, the effect of NMNP engineering on their performance, and the working principle of each engineering design for enhancing LFIA. Finally, current challenges and future improvements in this field are briefly discussed.


Assuntos
Imunoensaio/instrumentação , Nanopartículas Metálicas/química , Engenharia Química , Desenho de Fármacos , Ouro , Humanos , Magnetismo , Fenômenos Ópticos , Tamanho da Partícula
19.
Theranostics ; 12(6): 2801-2810, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35401815

RESUMO

Background: Gold nanoparticle-based immunochromatographic assay (AuNP-ICA) has insufficient sensitivity due to its inherent colorimetric signal intensity and low capture efficiency of AuNPs. The metal in situ growth is a common strategy to enhance the sensitivity of AuNP-ICA due to its superior signal amplification potential and simple operation. However, the detection distortion caused by metal self-nucleation during the growth process can seriously affect the accuracy and reproducibility of the strips. Methods: We present a pH-regulated gold in situ growth (GISG) strategy to amplify the colorimetric signal and demonstrate its application in improving the performance of traditional AuNP-ICA. The controllable growth signal amplification is achieved by lowering the pH of the growth solution to weaken the reducibility of hydroxylamine (HA), thus urging the crystallization and growth of Au3+ on the AuNP surface instead of free reduction and self-nucleation. In addition, the mechanism of pH regulation on HA reducibility is elucidated by introducing an electron-donating or electron-withdrawing group to affect the electron density of hydroxyl group. Results: The proposed GISG strategy shows improved sensitivity, low background, robust operation, and good reproducibility. The LOD values of the designed GISG-amplified AuNP-ICA are as low as 0.0198 ng mL-1 for hepatitis B surface antigen and 0.0125 ng mL-1 for HIV-1 capsid p24 antigen, which are lower by about 500- and 70-fold, respectively, than those of the unamplified AuNP-ICA. Conclusions: This method is extended to enable ultrasensitive and rapid diagnosis of viral infections, and has potential as a general signal amplification platform to redefine immunochromatographic diagnostics.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Colorimetria , Ouro/química , Concentração de Íons de Hidrogênio , Nanopartículas Metálicas/química , Reprodutibilidade dos Testes
20.
ACS Nano ; 16(2): 3351-3361, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35137583

RESUMO

Colorimetric lateral flow immunoassay (LFIA) with gold nanoparticles (AuNPs) as signal reporters has been widely used in point-of-care testing. Nonetheless, the potential of traditional AuNP-based LFIA for the early diagnosis of disease is often compromised by limited sensitivity due to the insufficient colorimetric signal brightness of AuNPs. Herein, we develop a "three-in-one" multifunctional catalytic colorimetric nanohybrid (Fe3O4@MOF@Pt) composed of Fe3O4 nanoparticles, MIL-100(Fe), and platinum (Pt) nanoparticles. Fe3O4@MOF@Pt displays enhanced colorimetric signal brightness, fast magnetic response, and ultrahigh peroxidase-mimicking activity, which are beneficial to the enhancement of the sensitivity of LFIA by coupling with magnetic separation and catalytic amplification. When integrated with the dual-antibody sandwich LFIA platform, the developed Fe3O4@MOF@Pt can achieve an ultrasensitive immunochromatographic assay of procalcitonin with a sensitivity of 0.5 pg mL-1, which is approximately 2280-fold higher than that of conventional AuNP-based LFIA and superior to previously published immunoassays. Therefore, this work suggests that the proposed catalytic colorimetric nanohybrid can act as promising signal reporters to enable ultrasensitive immunochromatographic disease diagnostics.


Assuntos
Colorimetria , Nanopartículas Metálicas , Colorimetria/métodos , Ouro/química , Imunoensaio/métodos , Fenômenos Magnéticos , Nanopartículas Metálicas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA