Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Doc Ophthalmol ; 136(1): 57-68, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29124422

RESUMO

PURPOSE: To characterize the ultrastructural and functional correlates of hydroxychloroquine (HCQ)-induced subclinical bull's eye lesion seen on near-infrared reflectance (NIR) imaging. METHODS: An asymptomatic 54-year-old male taking HCQ presented with paracentral ring-like scotoma, abnormal multifocal electroretinography (mfERG) and preserved ellipsoid zone on optical coherence tomography (OCT). Dense raster OCT was performed to create en face reflectivity maps of the interdigitation zone. Macular Integrity Assessment (MAIA) microperimetry and mfERG findings were compared with NIR imaging, en face OCT, retinal thickness profiles and wave-guiding cone density maps derived from flood-illumination adaptive optics (AO) retinal photography. RESULTS: The bull's eye lesion is an oval annular zone of increased reflectivity on NIR with an outer diameter of 1450 µm. This region corresponds exactly to an area of preserved interdigitation zone reflectivity in en face OCT images and of normal cone density on AO imaging. Immediately surrounding the bull's eye lesion is an annular zone (3°-12° eccentricity) of depressed retinal sensitivity on MAIA and reduced amplitude density on mfERG. Wave-guiding cone density at 2° temporal was 25,400 per mm2. This declined rapidly to 12,900 and 1200 per mm2 at 3° and 4°. CONCLUSION: Multimodal imaging illustrated pathology in the area surrounding the NIR bull's eye, characterized by reduced reflectance, wave-guiding cone density and retinal function. Further studies are required to investigate whether the bull's eye on NIR imaging and en face OCT is prominent or consistent enough for diagnostic use.


Assuntos
Antirreumáticos/toxicidade , Fóvea Central/efeitos dos fármacos , Hidroxicloroquina/toxicidade , Doenças Retinianas/induzido quimicamente , Escotoma/induzido quimicamente , Eletrorretinografia , Angiofluoresceinografia , Fóvea Central/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Retina/fisiopatologia , Células Fotorreceptoras Retinianas Cones/patologia , Doenças Retinianas/diagnóstico por imagem , Doenças Retinianas/fisiopatologia , Escotoma/diagnóstico por imagem , Escotoma/fisiopatologia , Tomografia de Coerência Óptica/métodos , Testes de Campo Visual
2.
Doc Ophthalmol ; 134(3): 227-235, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28382556

RESUMO

PURPOSE: Paraneoplastic retinopathy can be the first manifestation of systemic malignancy. A subset of paraneoplastic retinopathy is characterized by negative-type electroretinography (ERG) without fundus abnormality. Here we describe the multimodal imaging and clinico-pathological correlation of a unique case of acute progressive paravascular placoid neuroretinopathy with suspected retinal depolarizing bipolar cell dysfunction preceding the diagnosis of metastatic small cell carcinoma of the prostate. METHODS: ERG was performed according to the International Society for Clinical Electrophysiology of Vision standards. Imaging modalities included near-infrared reflectance, blue-light autofluorescence, fluorescein and indocyanine green angiographies, spectral domain optical coherence tomography, ultra-widefield colour and green-light autofluorescence imaging, microperimetry and adaptive optics imaging. Patient serum was screened for anti-retinal antibodies using western blotting. Immunostaining and histological analyses were performed on sections from human retinal tissues and a patient prostate biopsy. RESULTS: Serial multimodal retinal imaging, microperimetry and adaptive optics photography demonstrated a paravascular distribution of placoid lesions characterized by hyper-reflectivity within the outer nuclear layer resembling type 2 acute macular neuroretinopathy. There was no visible lesion within the inner nuclear layer despite electronegative-type ERG. Six months later, the patient presented with metastatic small cell carcinoma of the prostate. Tumour cells were immunopositive for glyceraldehyde-3-phosphate dehydrogenase, enolase and recoverin as well as neuroendocrine markers. The patient's serum reacted to cytoplasmic and nuclear antigens in the prostate biopsy and in human retina. Anti-retinal antibodies against several antigens were detected by both commercial and in-house western blots. CONCLUSIONS: A spectrum of autoreactive anti-retinal antibodies is associated with a unique phenotype of acute progressive paravascular placoid neuroretinopathy resulting in degeneration of photoreceptor cells, inner retinal dysfunction and classic electronegative ERG in paraneoplastic retinopathy. Detailed clinical, functional and immunological phenotyping of paraneoplastic retinopathy illustrated the complex mechanism of paraneoplastic syndrome.


Assuntos
Eletrorretinografia , Síndromes Paraneoplásicas/diagnóstico , Retina/patologia , Doenças Retinianas/diagnóstico , Doença Aguda , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal
3.
Retina ; 37(1): 124-134, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28005720

RESUMO

PURPOSE: To illustrate altered fundus autofluorescence in rubella retinopathy and to investigate their relationships with photoreceptor structure and function using multimodal imaging. METHODS: The authors report four cases of rubella retinopathy aged 8, 33, 42, and 50 years. All patients had dilated clinical fundus examination; wide-field color photography; blue, green, and near-infrared autofluorescence imaging and spectral domain optical coherence tomography. Two patients also underwent microperimetry and adaptive optics imaging. En face optical coherence tomography, cone mosaic, and microperimetry were coregistered with autofluorescence images. The authors explored the structure-function correlation. RESULTS: All four patients had a "salt-and-pepper" appearance on dilated fundus examination and wide-field color photography. There were variable-sized patches of hypoautofluorescence on both blue and near-infrared excitation in all four patients. Wave-guiding cones were visible and retinal sensitivity was intact over these regions. There was no correlation between hypoautofluorescence and regions of attenuated ellipsoid and interdigitation zones. Hyperautofluorescent lesions were also noted and some of these were pseudo-vitelliform lesions. CONCLUSION: Patchy hypoautofluorescence on near-infrared excitation can be a feature of rubella retinopathy. This may be due to abnormal melanin production or loss of melanin within retinal pigment epithelium cells harboring persistent rubella virus infection. Preservation of the ellipsoid zone, wave-guiding cones, and retinal sensitivity within hypoautofluorescent lesions suggest that these retinal pigment epithelium changes have only mild impact on photoreceptor cell function.


Assuntos
Células Fotorreceptoras Retinianas Cones/patologia , Doenças Retinianas/fisiopatologia , Rubéola (Sarampo Alemão)/complicações , Adulto , Criança , Angiofluoresceinografia , Fundo de Olho , Humanos , Pessoa de Meia-Idade , Células Fotorreceptoras Retinianas Cones/fisiologia , Doenças Retinianas/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Testes de Campo Visual , Campos Visuais/fisiologia
4.
Clin Exp Ophthalmol ; 43(5): 422-8, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25556534

RESUMO

BACKGROUND: The survival rates for patients diagnosed with uveal melanoma in Australia are unknown. Few long-term studies of uveal melanoma are available, and it is unclear whether their results are applicable to the Australian population. DESIGN: Retrospective population-based study. PARTICIPANTS: Patients diagnosed with uveal melanoma between 1981 and 2005 in Western Australia. METHODS: Three hundred eight cases were included. Relative survival and Cox regression were performed. Variables tested for their predictive ability included patient age and sex, tumour-specific variables, and treatment modality. MAIN OUTCOME MEASURES: All-cause survival rates and relative survival rates of patients with diagnosed uveal melanoma. RESULTS: Relative survival rates for the entire cohort were 88.2%, 81.4% and 71.4% at 3, 5 and 10 years, respectively. Predictors of worse survival included mixed-cell tumour morphology (hazard ratio [HR] = 2.1; P-value = 0.002), tumour location at the ciliary body (HR = 1.7; P-value = 0.029) and tumour apical height more than 5 mm (HR 1.9, P-value = 0.026). Of all patients who underwent enucleation, those diagnosed in 1998-2005 died twice as fast (HR = 2.3; P-value = 0.004). In the 17 patients with metastasis, the median survival time from date of diagnosis of metastasis was 3.1 months. CONCLUSIONS: These survival estimates are comparable to those reported for the USA, and more optimistic than those reported for most European-based studies. Tumour apical height, tumour site, tumour morphology and having an enucleation in certain calendar periods of diagnosis were independent predictors of survival. Survival prognosis for patients with diagnosed metastatic uveal melanoma is very poor.


Assuntos
Melanoma/mortalidade , Neoplasias Uveais/mortalidade , Adolescente , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/uso terapêutico , Braquiterapia , Feminino , Humanos , Masculino , Melanoma/patologia , Melanoma/terapia , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Oftalmológicos , Sistema de Registros , Estudos Retrospectivos , Distribuição por Sexo , Taxa de Sobrevida , Neoplasias Uveais/patologia , Neoplasias Uveais/terapia , Austrália Ocidental/epidemiologia
6.
Sci Rep ; 11(1): 16641, 2021 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-34404857

RESUMO

Adaptive optics flood illumination ophthalmoscopy (AO-FIO) is an established imaging tool in the investigation of retinal diseases. However, the clinical interpretation of AO-FIO images can be challenging due to varied image quality. Therefore, image quality assessment is essential before interpretation. An image assessment tool will also assist further work on improving the image quality, either during acquisition or post processing. In this paper, we describe, validate and compare two automated image quality assessment methods; the energy of Laplacian focus operator (LAPE; not commonly used but easily implemented) and convolutional neural network (CNN; effective but more complex approach). We also evaluate the effects of subject age, axial length, refractive error, fixation stability, disease status and retinal location on AO-FIO image quality. Based on analysis of 10,250 images of 50 × 50 µm size, at 41 retinal locations, from 50 subjects we demonstrate that CNN slightly outperforms LAPE in image quality assessment. CNN achieves accuracy of 89%, whereas LAPE metric achieves 73% and 80% (for a linear regression and random forest multiclass classifier methods, respectively) compared to ground truth. Furthermore, the retinal location, age and disease are factors that can influence the likelihood of poor image quality.

7.
Transl Vis Sci Technol ; 10(6): 16, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-34111262

RESUMO

Purpose: Microperimetry measures differential light sensitivity (DLS) at specific retinal locations. The aim of this study is to examine the variation in DLS across the macula and the contribution to this variation of cone distribution metrics and retinal eccentricity. Methods: Forty healthy eyes of 40 subjects were examined by microperimetry (MAIA) and adaptive optics imaging (rtx1). Retinal DLS was measured using the grid patterns: foveal (2°-3°), macular (3°-7°), and meridional (2°-8° on horizontal and vertical meridians). Cone density (CD), distribution regularity, and intercone distance (ICD) were calculated at the respective test loci coordinates. Linear mixed-effects regression was used to examine the association between cone distribution metrics and loci eccentricity, and retinal DLS. Results: An eccentricity-dependent reduction in DLS was observed on all MAIA grids, which was greatest at the foveal-parafoveal junction (2°-3°) (-0.58 dB per degree, 95% confidence interval [CI]; -0.91 to -0.24 dB, P < 0.01). Retinal DLS across the meridional grid changed significantly with each 1000 cells/deg2 change in CD (0.85 dB, 95% CI; 0.10 to 1.61 dB, P = 0.03), but not with each arcmin change in ICD (1.36 dB, 95% CI; -2.93 to 0.20 dB, P = 0.09). Conclusions: We demonstrate significant variation in DLS across the macula. Topographical change in cone separation is an important determinant of the variation in DLS at the foveal-parafoveal junction. We caution the extrapolation of changes in DLS measurements to cone distribution because the relationship between these variables is complex. Translational Relevance: Cone density is an independent determinant of DLS in the foveal-parafoveal junction in healthy eyes.


Assuntos
Fotofobia , Células Fotorreceptoras Retinianas Cones , Contagem de Células , Voluntários Saudáveis , Humanos , Acuidade Visual
8.
Transl Vis Sci Technol ; 9(7): 19, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32832226

RESUMO

Purpose: Macular Integrity Assessment (MAIA) microperimetry is used widely in clinical trials and routine practice to assess paracentral scotoma. Current interpretation of MAIA is based on an assumed uniform 25 decibel (dB) cutoff for normal function irrespective of subject age and retinal location. We examined this convention by establishing an age- and loci-specific reference in healthy eyes and comparing this to the <25 dB cutoff. Methods: Retrospective MAIA results from healthy eyes were analyzed for prevalence of loci with <25 dB. At each locus, a new reference cutoff was derived from quantile regression of sensitivity against age at the 2.5th percentile. Two clinical cases of serial MAIA testing were analyzed using the new approach and compared to the <25 dB cutoff. Results: Fifty-four and 56 age-matched (range: 16-75 years) healthy eyes underwent small (37 loci) and large (68 loci) grid testing, respectively. Retinal sensitivity <25 dB was found in 5% of the small grid (1998 data points) and 10% of the large grid (3808 data points). These were found predominantly in older subjects and at the central point or in the perifoveal region. Quantile regression at each individual locus showed age-related decline with a median gradient of 0.6 dB/decade. Conclusions: We caution against using <25 dB cutoff in MAIA interpretation and advocate an age- and loci-specific cutoff criterion. Translational Relevance: Our study suggests that MAIA interpretation is influenced by the criterion used for defining abnormal pointwise measurement.


Assuntos
Testes de Campo Visual , Campos Visuais , Adolescente , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Retina/diagnóstico por imagem , Estudos Retrospectivos , Acuidade Visual , Adulto Jovem
9.
Biomed Opt Express ; 9(2): 679-693, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29552404

RESUMO

Adaptive optics flood illumination ophthalmoscopy (AO-FIO) allows imaging of the cone photoreceptor in the living human retina. However, clinical interpretation of the AO-FIO image remains challenging due to suboptimal quality arising from residual uncorrected wavefront aberrations and rapid eye motion. An objective method of assessing image quality is necessary to determine whether an AO-FIO image is suitable for grading and diagnostic purpose. In this work, we explore the use of focus measure operators as a surrogate measure of AO-FIO image quality. A set of operators are tested on data sets acquired at different focal depths and different retinal locations from healthy volunteers. Our results demonstrate differences in focus measure operator performance in quantifying AO-FIO image quality. Further, we discuss the potential application of the selected focus operators in (i) selection of the best quality AO-FIO image from a series of images collected at the same retinal location and (ii) assessment of longitudinal changes in the diseased retina. Focus function could be incorporated into real-time AO-FIO image processing and provide an initial automated quality assessment during image acquisition or reading center grading.

10.
Transl Vis Sci Technol ; 6(6): 9, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29285417

RESUMO

PURPOSE: We compared cone density measurements derived from the center of gaze-directed single images with reconstructed wide-field montages using the rtx1 adaptive optics (AO) retinal camera. METHODS: A total of 29 eyes from 29 healthy subjects were imaged with the rtx1 camera. Of 20 overlapping AO images acquired, 12 (at 3.2°, 5°, and 7°) were used for calculating gaze-directed cone densities. Wide-field AO montages were reconstructed and cone densities were measured at the corresponding 12 loci as determined by field projection relative to the foveal center aligned to the foveal dip on optical coherence tomography. Limits of agreement in cone density measurement between single AO images and wide-field AO montages were calculated. RESULTS: Cone density measurements failed in 1 or more gaze directions or retinal loci in up to 58% and 33% of the subjects using single AO images or wide-field AO montage, respectively. Although there were no significant overall differences between cone densities derived from single AO images and wide-field AO montages at any of the 12 gazes and locations (P = 0.01-0.65), the limits of agreement between the two methods ranged from as narrow as -2200 to +2600, to as wide as -4200 to +3800 cones/mm2. CONCLUSIONS: Cone density measurement using the rtx1 AO camera is feasible using both methods. Local variation in image quality and altered visibility of cones after generating montages may contribute to the discrepancies. TRANSLATIONAL RELEVANCE: Cone densities from single AO images are not interchangeable with wide-field montage derived-measurements.

11.
Asia Pac J Ophthalmol (Phila) ; 6(1): 70-79, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28161925

RESUMO

We reviewed the current literature on the ability of microperimetry to detect non-neovascular age-related macular degeneration (AMD) disease progression. The index test was retinal sensitivity measurement assessed by microperimetry and comparators were other functional measures (best-corrected and low-luminance visual acuities, and fixation stability) and structural parameters [retinal thickness, choroidal thickness, and area of geographic atrophy (GA) determined by color fundus photographs, short-wave or near-infrared fundus autofluorescence]. The reference standard was area of GA. The literature search was conducted in January 2016 and included MEDLINE, EMBASE, the Cochrane Library, Biosis, Science Citation Index, ProQuest Health and Medicine, CINAHL, and Highwire Press. We included 6 studies that enrolled 41 eyes with intermediate AMD (from a single study) and 80 eyes with GA secondary to AMD. Retinal sensitivity measured by microperimetry was the only functional measure that consistently detected progression in each cohort. Insufficient reported data precluded meta-analysis. Various microperimetry parameters were used to assess cohort-level change in retinal sensitivity, but the methods of analysis have yet to mature in complexity in comparison with established glaucoma field progression analysis. Microperimetry-assessed retinal sensitivity measurement may be more sensitive in detecting progression than other functional measures in non-neovascular AMD. However, the lack of standardized testing protocol and methods of progression analysis hindered comparison. Harmonization of testing protocol and development of more robust methods of analyzing raw microperimetric data will facilitate clinical implementation of this valuable retinal assessment tool.


Assuntos
Degeneração Macular/diagnóstico , Testes de Campo Visual/métodos , Progressão da Doença , Fixação Ocular/fisiologia , Atrofia Geográfica/diagnóstico , Atrofia Geográfica/fisiopatologia , Humanos , Degeneração Macular/fisiopatologia , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia , Campos Visuais/fisiologia
12.
PLoS One ; 11(12): e0168275, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27959968

RESUMO

PURPOSE: To present en face optical coherence tomography (OCT) images generated by graph-search theory algorithm-based custom software and examine correlation with other imaging modalities. METHODS: En face OCT images derived from high density OCT volumetric scans of 3 healthy subjects and 4 patients using a custom algorithm (graph-search theory) and commercial software (Heidelberg Eye Explorer software (Heidelberg Engineering)) were compared and correlated with near infrared reflectance, fundus autofluorescence, adaptive optics flood-illumination ophthalmoscopy (AO-FIO) and microperimetry. RESULTS: Commercial software was unable to generate accurate en face OCT images in eyes with retinal pigment epithelium (RPE) pathology due to segmentation error at the level of Bruch's membrane (BM). Accurate segmentation of the basal RPE and BM was achieved using custom software. The en face OCT images from eyes with isolated interdigitation or ellipsoid zone pathology were of similar quality between custom software and Heidelberg Eye Explorer software in the absence of any other significant outer retinal pathology. En face OCT images demonstrated angioid streaks, lesions of acute macular neuroretinopathy, hydroxychloroquine toxicity and Bietti crystalline deposits that correlated with other imaging modalities. CONCLUSIONS: Graph-search theory algorithm helps to overcome the limitations of outer retinal segmentation inaccuracies in commercial software. En face OCT images can provide detailed topography of the reflectivity within a specific layer of the retina which correlates with other forms of fundus imaging. Our results highlight the need for standardization of image reflectivity to facilitate quantification of en face OCT images and longitudinal analysis.


Assuntos
Aumento da Imagem/métodos , Imagem Multimodal , Retina/diagnóstico por imagem , Epitélio Pigmentado da Retina/diagnóstico por imagem , Tomografia de Coerência Óptica , Adulto , Algoritmos , Lâmina Basilar da Corioide/patologia , Feminino , Angiofluoresceinografia , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Oftalmoscopia , Óptica e Fotônica , Retina/patologia , Epitélio Pigmentado da Retina/patologia , Software , Espectroscopia de Luz Próxima ao Infravermelho
13.
Biomed Opt Express ; 6(12): 4676-93, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26713186

RESUMO

A large number of human retinal diseases are characterized by a progressive loss of cones, the photoreceptors critical for visual acuity and color perception. Adaptive Optics (AO) imaging presents a potential method to study these cells in vivo. However, AO imaging in ophthalmology is a relatively new phenomenon and quantitative analysis of these images remains difficult and tedious using manual methods. This paper illustrates a novel semi-automated quantitative technique enabling registration of AO images to macular landmarks, cone counting and its radius quantification at specified distances from the foveal center. The new cone counting approach employs the circle Hough transform (cHT) and is compared to automated counting methods, as well as arbitrated manual cone identification. We explore the impact of varying the circle detection parameter on the validity of cHT cone counting and discuss the potential role of using this algorithm in detecting both cones and rods separately.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA