Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Pharm Sci ; 111(9): 2451-2457, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35753411

RESUMO

Fast-acting insulin drug products (DPs) are carried and administered by diabetic patients to maintain their blood glucose level throughout the day, exposing the DPs to stress conditions. Apidra, Novolog, and Humalog insulin DPs were tested under various stress conditions. Dynamic light scattering (DLS), and size exclusion chromatography (SEC) were used to monitor the stability and aggregation. Thermal stress alone did not influence the stability. However, 24 hr exposure to vigorous mechanical stress shifted the DLS size peaks of Novolog and Humalog from 5 ± 1 nm to > 50.9 ± 25.6 nm, and the SEC native protein peak areas decreased 52% for Novolog and 18.4% for Humalog. Combined stress accelerated protein aggregation more drastically. Novolog and Humalog size shifted (>75 nm) after 3 hr and the peak area decreased > 97.9% after 6 hr exposure, indicating that high temperature accelerated the aggregation triggered by agitation. Soluble aggregates were captured by DLS early on compared to SEC. Apidra was comparably stable indicating DP formulation plays a critical role in stability. Our study provides a greater understanding of potential failure modes patients and care givers may encounter while handling insulin DPs.


Assuntos
Insulina Aspart , Agregados Proteicos , Cromatografia em Gel , Difusão Dinâmica da Luz , Humanos , Insulina Lispro
2.
J Pharm Sci ; 109(11): 3330-3339, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32835703

RESUMO

The presence of aggregates in monoclonal antibody (mAb) drug product (DP) formulations can present product quality challenges. Here we show that use of High Performance Size Exclusion Chromatography (HP-SEC), in conjunction with high-throughput dynamic light scattering (HT-DLS) analyses of mAb DPs can be a useful strategy to determine monomer content and the presence of aggregates under simulated stress conditions. This analytical approach was used to evaluate four commercially available mAb DPs under different conditions i.e.; original formulations, diluted, and thermo-mechanical stressed condition. Due to particle size limitations of HP-SEC columns, resulting in particles accumulating in the column frits prior to reaching the detector for analysis, there is a possibility that large mAb aggregates may not be detected. Both HP-SEC and HT-DLS were able to detect and resolve the mAb monomer (~10-12 nm) of the DPs in their recommended storage conditions. However, the ability to detect large aggregates (>40 nm) by both analytical methods differed, and HT-DLS was able to detect aggregates between 60 nm and 1400 nm under stress conditions. Our data indicates that HP-SEC, in conjunction with HT-DLS, may be beneficial to detect both mAb DP monomer content and multiple aggregate species (1-1000 nm) in the submicron size range.


Assuntos
Antineoplásicos Imunológicos , Preparações Farmacêuticas , Anticorpos Monoclonais , Cromatografia em Gel , Difusão Dinâmica da Luz
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA