1.
Indian Pacing Electrophysiol J ; 24(2): 68-74, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38096986

RESUMO

INTRODUCTION: During radiofrequency (RF) ablation, impedance monitoring has been used to avoid steam-pop caused by excessive intramyocardial temperature (IMT) rise. However, it is uncertain why the impedance decline is related to steam-pop and whether the impedance decline is correlated to IMT. METHODS: Twenty-one bipolar ablations (40 W, 30-g contact, 120 s) were attempted for seven perfused porcine myocardium. Immediately after ablation, a temperature electrode was inserted into the mid-myocardial portion, and the recovery process of impedance and its correlation to IMT were assessed. RESULTS: Transmural lesion was created in all 21 applications but steam-pop occurred in 5/21 applications with large impedance decline. In the 16 applications without steam-pop, impedance and IMT soon after ablation were 97.2 ± 4.0 Ω and 66.1 ± 4.8 °C, respectively. Reasonably high linear correlation was demonstrated between the maximum IMT after ablation and impedance differences before and after ablation. Recovery processes of the decreased impedance and the elevated IMT fit well to each equation of the single exponential decay function and showed symmetric shapes with no statistical difference of time constant (100.1 ± 34.5 s in impedance vs. 108.7 ± 27.3 s in IMT) and half-time of recovery (144.5 ± 49.8 s in impedance vs. 156.9 ± 39.4 s in IMT). Recovered impedance after ablation (104.8 ± 3.9 Ω) was 5.1 ± 2.0 Ω smaller than that before ablation (109.9 ± 2.7 Ω), suggesting several factors other than IMT rise participate in impedance decline in RF ablation. CONCLUSIONS: Recovery of impedance and IMT after ablation well correlated, which supports the usefulness of impedance monitoring for safe RF ablation.

2.
J Cardiovasc Electrophysiol ; 34(4): 928-941, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36852910

RESUMO

INTRODUCTION: Radiofrequency (RF) catheter ablation induces excitation recoverable myocardium around durable core lesions, and its distribution may be different depending on energy delivery methods. METHODS AND RESULTS: In coronary perfusing porcine hearts, pacing threshold through the ventricle was measured using eight-pole (1-mm distance) needle electrodes vertically inserted into myocardium before, within 3 min after and 40 min after 40 W ablation with 10-g catheter contact (Group 1: irrigation catheter for 15 s, Group 2: irrigation catheter for 40 s, Group 3: nonirrigation catheter for 15 s, Group 4: nonirrigation catheter for 40 s). Ablation was accomplished in all 12 ablations in Groups 1-3 whereas in 8/12 ablations in Group 4 because of high-temperature rise. Within 3 min after ablation, 10.0 V pacing uncaptured electrodes were distributed from the surface to inside the myocardium, and its depth was deeper in 40 s than in 15 s ablation. 40 min after ablation, excitation recovery at one or more electrodes below the durable lesion was observed in all Groups. Excitation recovery electrodes were also observed on the surface in Group 1 but not the other Groups. Accordingly, the number of excitation-recovered electrodes were larger in Group 1 than the other Groups. CONCLUSIONS: Regardless of the ablation methods, excitation recoverable myocardium was present around 1.0 mm below the durable lesions. Lesions created by short application time using an irrigation catheter may have included large excitation recoverable myocardium soon after ablation because of the presence of reversible myocardium on well-irrigated myocardial surfaces.


Assuntos
Ablação por Cateter , Miocárdio , Animais , Suínos , Miocárdio/patologia , Coração , Ablação por Cateter/métodos , Eletrodos , Ventrículos do Coração/cirurgia
3.
J Cardiovasc Electrophysiol ; 33(12): 2538-2545, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36135613

RESUMO

INTRODUCTION: Bipolar (BIP) radiofrequency (RF) ablation creates deep myocardial lesions but ideal energy application modes to treat ventricular arrhythmias originating from deep inside the thick myocardium have not been well established. An experimental study was performed to clarify whether high power and long application time BIP ablation were performable by impedance-decline-guide power control (PC) and whether it could create transmural lesions in the thick ventricle with a minimum risk of steam-pop. METHODS AND RESULTS: Perfused porcine ventricle (18.4 ± 2.3 mm) was placed in an experimental bath and BIP ablation (50 W) for 120 s was attempted with catheter contact of 30-g using two protocols; fixed power (FP) and impedance-decline-guide PC. In the latter protocol, BIP ablation was started from 50 W, while the energy was decreased to 40-20 W according to the impedance decline during RF ablation. FP ablation was attempted in 30 applications and the transmural lesion was created in all 30, although steam-pop occurred in 16/30 applications (53%). Low minimum impedance, large total impedance decline (TID), and %-TID were associated with the steam-pop occurrence. PC ablation was attempted in another 21 applications, and the transmural lesion was created in all 21 without steam-pop. PC ablation was superior to FP ablation (21/21 vs. 14/30, p < .001) in the creation of a transmural lesion without resulting in steam-pop. CONCLUSIONS: High power and long application time BIP ablation seems to be feasible according to the impedance-decline-guide approach, which could create transmural lesions in thick porcine ventricles with minimal risk of steam-pop.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Impedância Elétrica , Irrigação Terapêutica/métodos , Modelos Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Desenho de Equipamento
4.
Pacing Clin Electrophysiol ; 45(11): 1330-1337, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36111963

RESUMO

BACKGROUND: The incidence of electrical storm (ES) is significantly higher during the daytime. However, the association between nocturnal ventricular tachyarrythmias during ES and prognosis remains unclear. Therefore, this study aimed to investigate the clinical characteristics and outcomes of ES with midnight ventricular tachyarrythmias. METHODS: We included 48 consecutive patients who had an implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator implanted between 2010 and 2020 and those who had experienced the onset of an out-of-hospital ES episode. According to the midnight (0:00 a.m.-6:00 a.m.) occurrence of ventricular arrythmia events consisting of ventricular tachycardia (VT) and ventricular fibrillation (VF), we divided them into two groups (with-midnight group: n = 27, without-midnight group: n = 21). The clinical characteristics and outcomes of the two groups were compared. RESULTS: The patients in the with-midnight group were mostly males, had longer QRS duration, and longer corrected QT-interval than those in the without-midnight group (p < .05). The incidence of all-cause death, especially heart failure death, was higher in the with-midnight group than in the without-midnight group (p < .01). Multivariate analysis showed that the presence of midnight VT/VF during ES was the only independent risk factors for heart failure death (HR = 18.9, 95%CI = 1.98-181, p = .011). CONCLUSIONS: The presence of midnight VT/VF during ES might be associated with the poor prognosis. The loss of a sympathetic circadian pattern of VT/VF distribution during ES might suggest advanced stages of the cardiac disease.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Masculino , Humanos , Feminino , Fibrilação Ventricular/etiologia , Taquicardia Ventricular/etiologia , Desfibriladores Implantáveis/efeitos adversos , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/terapia , Arritmias Cardíacas/terapia , Fatores de Risco
5.
Int Heart J ; 63(3): 476-485, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35650149

RESUMO

Antimitochondrial antibodies (AMA) are serum autoantibodies specific to primary biliary cholangitis and are linked to myopathy and myocardial damage; however, the presence of AMA as a risk factor for ventricular tachyarrhythmias (VTs) has remained unknown. This study aimed to elucidate whether the presence of AMA-related noncardiac diseases indicates VTs risk.This cohort study enrolled 1,613 patients (883 females) who underwent AMA testing to assess noncardiac diseases. The incidence of VTs and supraventricular tachyarrhythmias (SVTs) from a year before the AMA testing to the last visit of the follow-up were retrospectively investigated as primary and secondary objectives. Using propensity score matching, we extracted AMA-negative patients whose covariates were matched to those of 152 AMA-positive patients. In this propensity score-matched cohort, the incidence of VTs and SVTs in the AMA-positive patients were compared with that in AMA-negative patients.The AMA-positive patients had higher estimated cumulative incidence (log-rank, P = 0.013) and prevalence (5.9% versus 0.7%, P = 0.020) of VTs than the AMA-negative patients. The presence of AMA was an independent risk factor for VTs (hazard ratio, 4.02; 95% CI, 1.44-20.01; P = 0.005). Meanwhile, AMA were associated with atrial flutter and atrial tachycardia development. In AMA-positive patients, VTs were associated with male sex, underlying myopathy, high creatine kinase levels, presence of chronic heart failure or ischemic heart disease, left ventricular dysfunction, presence of SVTs, and the electrocardiographic parameters indicating atrial disorders.The presence of AMA-related noncardiac diseases is an independent risk factor for VTs.


Assuntos
Flutter Atrial , Taquicardia Supraventricular , Taquicardia Ventricular , Flutter Atrial/complicações , Estudos de Coortes , Feminino , Humanos , Masculino , Estudos Retrospectivos , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia
6.
J Cardiovasc Electrophysiol ; 32(7): 1939-1946, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33928698

RESUMO

INTRODUCTION: The local conduction delay has been deemed to play an important role in the perpetuation of ventricular fibrillation (VF) in Brugada syndrome (BrS). We evaluated the relationship between the activation delay during programmed stimulation and cardiac events in BrS patients. METHODS: This study included 47 consecutive BrS patients who underwent an electrophysiological study and received implantable cardiac defibrillator therapy. We divided the patients into two groups based on whether they had developed VF (11 patients) or not (36 patients) during the follow-up period of 89 ± 53 months. The activation delay was assessed using the interval between the stimulus and the QRS onset during programmed stimulation. The mean increase in delay (MID) was used to characterize the conduction curves. RESULTS: The MID at the right ventricular outflow tract (RVOT) was significantly greater in patients with VF (4.5 ± 1.2 ms) than in those without VF (2.2 ± 0.9 ms) (p < .001). A receiver operating characteristics curve analysis indicated that the optimal cut-off point for discriminating VF occurrence was 3.3 with 88.9% sensitivity and 91.3% specificity. Furthermore, patients with an MID at the RVOT ≥ 3.3 ms showed significantly higher rates of VF recurrence than those with an MID at the RVOT < 3.3 ms (p < .001). The clinical characteristics, including the signal-averaged electrocardiogram measurement and VF inducibility were similar between the two groups. CONCLUSION: A prolonged MID at the RVOT was associated with VF and maybe an additional electrophysiological risk factor for VF in BrS patients.


Assuntos
Síndrome de Brugada , Arritmias Cardíacas , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia , Ventrículos do Coração , Humanos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia
7.
Europace ; 23(12): 2029-2038, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34179980

RESUMO

AIMS: Although shortening of the corrected QT interval (QTc) is a key finding in the diagnosis of short QT syndrome (SQTS), there may be overlap of the QTc between SQTS patients and normal subjects in childhood and adolescence. We aimed to investigate electrocardiographic findings for differentiation of SQTS patients. METHODS AND RESULTS: The SQTS group comprised 34 SQTS patients <20 years old, including 9 from our institutions and 25 from previous reports. The control group comprised 61 apparently healthy subjects with an QTc of <360 ms who were selected from 13 314 participants in a school-based screening programme. We compared electrocardiographic findings, including QT and Jpoint-Tpeak intervals (QT and J-Tpeak, respectively), those corrected by using the Bazett's and Fridericia's formulae (cB and cF, respectively) and early repolarization (ER) between the groups. QT, QTc by using Bazett's formula (QTcB), QTc by using Fridericia's formula (QTcF), J-Tpeak, J-Tpeak cB, and J-Tpeak cF were significantly shorter in the SQTS group than in the control group. On receiver operating characteristic curve analysis, the area under the curve (AUC) was largest for QTcB (0.888) among QT, QTcB, and QTcF, with a cut-off value of 316 ms (sensitivity: 79.4% and specificity: 96.7%). The AUC was largest for J-Tpeak cB (0.848) among J-Tpeak, J-Tpeak cB, and J-Tpeak cF, with a cut-off value of 181 ms (sensitivity: 80.8% and specificity: 91.8%). Early repolarization was found more frequently in the SQTS group than in the control group (67% vs. 23%, P = 0.001). CONCLUSION: A QTcB <316 ms, J-Tpeak cB < 181 ms, and the presence of ER may indicate SQTS patients in childhood and adolescence.


Assuntos
Arritmias Cardíacas , Eletrocardiografia , Adolescente , Adulto , Arritmias Cardíacas/diagnóstico , Criança , Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Humanos , Adulto Jovem
8.
Pacing Clin Electrophysiol ; 44(10): 1675-1682, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34346080

RESUMO

BACKGROUND: Remote monitoring (RM) has been shown to reduce all-cause mortality in patients with implantable cardioverter-defibrillators or cardiac resynchronization therapy defibrillators (ICD/CRT-D). Not all devices transmit an alert for antitachycardia pacing (ATP) therapy, and it is unknown whether differences of RM alert affect the outcomes of electrical storm (ES). METHODS: We enrolled 42 patients with ICD/CRT-D whose out-of-hospital ES were detected by RM between 2013 and 2020. We divided their 54 episodes into two groups (ATP-alert-on; 22, ATP-alert-off; 32), and clinical outcomes were compared between the two groups. RESULTS: In 35 of 54 episodes of ES, ventricular tachycardia (VT) could be terminated within 24 h of ES onset just by ATP (ATP-alert-on: 14, ATP-alert-off: 21); however, many patients subsequently received shock delivery for VT. Among the 35 episodes, only in ATP-alert-on group, seven patients were prompted to visit our hospital without ICD shock through confirmation of ES by ATP-alert. Episodes that led to shock delivery 24 h or longer after the ES onset were significantly less common in the ATP-alert-on group (ATP-alert-on: 1/14, ATP-alert-off: 9/21, p = .03). Although there were no significant differences in the number of shock deliveries between episodes in the two groups, the number of ATP deliveries were significantly fewer in the ATP-alert-on group (12[7-26] vs. 29[16-53] in ATP-alert-off group, p = .03). Multivariate logistic regression analyses showed that the only ATP-alert significantly reduced ATP deliveries (HR = 0.14, 95%CI = 0.04-0.57, p = .003). CONCLUSION: Remote monitoring with an ATP-alert function during electrical storm may reduce appropriate ICD therapy through prompting early review.


Assuntos
Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Tecnologia sem Fio , Idoso , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
J Cardiovasc Electrophysiol ; 31(12): 3302-3310, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32981132

RESUMO

INTRODUCTION: This experimental study was conducted to explore impedance monitoring for safely performing bipolar (BIP) radiofrequency (RF) ablation targeted to arrhythmia focus. METHODS AND RESULTS: Using a newly designed dual-bath experimental model, contact-force-controlled (20-g) BIP ablation (50 W, 60 s) was attempted for porcine left ventricle (17.0 ± 2.7 mm thickness). BIP ablation was successfully accomplished for 60 s in 75 of the 89 RF applications (84.3%), whereas audible steam-pop occurred in the other 14 RF applications (15.7%). Receiver operating characteristic analysis demonstrated the optimal predictive values regarding the occurrence of steam-pop as follows; thinner myocardial wall (≤14.8 mm), low minimum impedance (≤89 ohm), greater total impedance decrement (TID) (≤ -25 ohm) and %TID (≤ -22.5%). Greater impedance decrement was not observed immediately preceding the occurrence of steam-pop but appeared around 15 s before. Four steam-pops happened before reaching the optimal predictive values of minimum impedance, whereas all 14 steam-pops developed 11.5 ± 9.2 and 8.1 ± 8.1 s after reaching the optimal predictive values of TID and %TID, respectively. Total lesion depth (endocardial plus epicardial) was 10.7 ± 1.2 mm on average, and was well correlated with TID and %TID. Transmural lesion through the myocardial wall was created in 22 RF applications. CONCLUSION: Relatively thinner areas of the myocardium are likely to be at greater risk for steam-pop during BIP RF ablation. Lowering the RF application energy to reduce the impedance decrement may help to lessen this risk.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Animais , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Vapor , Suínos
10.
Pacing Clin Electrophysiol ; 43(9): 983-991, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32524624

RESUMO

BACKGROUND: Anti-tachycardia pacing (ATP) delivered from an implantable device is an important tool to terminate ventricular tachycardia (VT). But its real-world efficacy for fast VT has not been fully studied. METHODS: Using the database of Nippon-storm study, effect of patient-by-patient basis ATP programming for fast VT (≥188 bpm) was assessed for the patients with structural heart diseases. Fast VTs were divided into three groups depending on heart rate (HR); Group A was 188-209 bpm, and Group-B and Group-C were 210-239 bpm and ≥240 bpm, respectively. RESULTS: During a median follow-up of 28 months, 202 fast VT episodes (209 ± 19 bpm) were demonstrated in the 85 patients. ATP terminated 151 of the 202 episodes (74.8%) in total. The success rate of the ATP was not different among the three groups: 73.3% in Group A, 80.6% in Group B, and 66.7% in Group C. ATP success rate of >50% and >70% was 77.6% and 64.7% of the patients, respectively. Left ventricular ejection fraction (LVEF) was significantly higher in the patients with rather than without successful ATP therapy, and receiver operating characteristic (ROC) analysis revealed that LVEF of 23% was the optimal cut-off value. ATP was less effective in patients taking amiodarone, but etiology of the structural heart diseases, indication of the device implantation, and all Electrocardiogram (ECG) parameters were not useful predictors for successful ATP therapy. CONCLUSIONS: ATP highly terminated fast VT with wide HR ranges in patients with structural heart diseases, and should be considered as the first-line therapy for fast VT except for patients with very low LVEF.


Assuntos
Cardioversão Elétrica/instrumentação , Cardiopatias/complicações , Taquicardia Ventricular/prevenção & controle , Idoso , Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Eletrocardiografia , Feminino , Humanos , Japão , Masculino , Taquicardia Ventricular/fisiopatologia
11.
Int Heart J ; 61(2): 338-346, 2020 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-32173709

RESUMO

Sympathetic nerve activity has arrhythmogenic potential for ventricular arrhythmias associated with structural heart diseases. However, a sufficient amount of beta-blockers occasionally cannot be prescribed in some patients.An experimental study was performed to clarify the therapeutic effects of bepridil, a multiple ionic current inhibitor that does not affect beta-adrenergic receptors, for premature beats occurring during enhanced sympathetic nerve activity. Cardio-sympathetic nerve activity was augmented via stellate-ganglion (SG) stimulation in a canine model (n = 8), and the arrhythmogenic potential and anti-arrhythmic effects of bepridil (2 and 4 mg/kg intravenously) were assessed. For safe use, vagal-stimulation-induced slow HR and programmed electrical stimulation were applied to evaluate possible pro-arrhythmic effects of the drug. Heart rate variability (HRV) indexes were used to estimate cardio-autonomic nerve activity.Either side of the SG-stimulation increased BP and HR. Premature beats were induced in 10/16 SG-stimulations and it was more frequent in left (8/8) rather than right stimulation (2/8). Following 2 mg/kg drug administration, premature beats were still inducible in 8/16 stimulations (7/8 in left and 1/8 in right), but burden of the premature beats decreased from 87.1 ± 46.8 to 62.1 ± 42.6 beats. After 4 mg/kg administration, premature beats were inducible in one SG-stimulation. Proarrhythmic effects were not observed in all experiments. Steady-state HRV indexes and percent increases in SG-stimulation-induced BP-elevation and HR-acceleration were similar among the 3 periods (before, 2 and 4 mg/kg of the drug).Bepridil may be an option for ventricular arrhythmias developed during enhanced cardio-sympathetic nerve activity with minimal effect on autonomic nerve responses.


Assuntos
Antiarrítmicos/uso terapêutico , Bepridil/uso terapêutico , Complexos Ventriculares Prematuros/tratamento farmacológico , Animais , Antiarrítmicos/farmacologia , Bepridil/farmacologia , Pressão Sanguínea/efeitos dos fármacos , Cães , Avaliação Pré-Clínica de Medicamentos , Estimulação Elétrica , Eletrocardiografia/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Gânglio Estrelado
12.
J Stroke Cerebrovasc Dis ; 28(3): 612-618, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30472173

RESUMO

OBJECTIVE: To investigate the prevalence and outcomes of asymptomatic coronary artery disease (CAD) in patients with the first episode of ischemic stroke. METHODS: Patients admitted to our hospital between November 2001 and January 2009 for the episode of an acute ischemic stroke/transient ischemic attack were included. Stress-Tl-201 scintigraphy was performed and followed by coronary angiography (CAG). The prevalence and risks for asymptomatic CAD, and long-term outcomes were studied. RESULTS: Of 1309 patients, only 15 (1.1%) patients presented with a history of CAD. Excluding 406 patients because of severity, systemic infection, early transfer to another hospital, or a refusal to participate, myocardial scintigraphy was performed in 903 patients (mean age, 72 ± 10 years, male 63.9%), and myocardial ischemia was diagnosed in 214 patients (23.7%). Of these patients, 76 patients underwent CAG, and showed significant stenosis (>75%) of a coronary artery in 61 (80.3%) patients. The risk factors for positive scintigraphy findings and CAG were high-grade premature complexes via Holter monitoring (P < .0001), enlarged left ventricle (P = .0051) and wall motion abnormalities (P = .0014) observed on echocardiography, and carotid artery stenosis observed in magnetic resonance angiography imaging (P < .0001). During the follow-up periods of 83 ± 47 months and of 91 ± 47 months, 17.2% of scintigraphy-positive and 2.8% of scintigraphy-negative patients developed episodes of myocardial ischemia, respectively (P < .001). CONCLUSIONS: Symptomatic CAD was rare in Japanese patients with the first episode of ischemic stroke, but asymptomatic CAD was identified by stress Tl-201 myocardial scintigraphy in one-quarter of the patients. Positive scintigraphy was associated with asymptomatic CAD and future cardiac events.


Assuntos
Isquemia Encefálica/epidemiologia , Doença da Artéria Coronariana/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/terapia , Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Progressão da Doença , Feminino , Humanos , Japão/epidemiologia , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Admissão do Paciente , Tomografia por Emissão de Pósitrons , Prevalência , Prognóstico , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Fatores de Tempo
13.
Int Heart J ; 60(5): 1161-1167, 2019 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-31484866

RESUMO

Therapy-resistant ventricular arrhythmias can occur during accidental advanced hypothermic conditions. On the other hand, hypothermic therapy using mild cooling has been successfully accomplished with infrequent ventricular arrhythmia events.To further clarify the therapeutic-resistant arrhythmogenic substrate which develops in hypothermic conditions, an experimental study was performed using a perfusion wedge preparation model of porcine ventricle, and electrophysiological characteristics, inducibility of ventricular arrhythmias, and effects of therapeutic interventions were assessed at 3 target temperatures (37, 32 and 28°C).As the myocardial temperature decreased, myocardial contractions and the number of spontaneous beats deceased. Depolarization (QRS width, stimulus-QRS interval) and repolarization (QT interval, ERP) parameters progressively increased, and dispersion of the ventricular repolarization increased. At 28°C, VF tended to be inducible more frequently (1/11 at 37°C, 1/11 at 32°C, and 5/11 hearts at 28°C), and some VFs at 28°C required greater defibrillation energy to resume basic rhythm.An advanced but not a mild hypothermic condition had an enhanced arrhythmogenic potential in our model. In the advanced hypothermic condition, VF with relatively prolonged F-F intervals and a greater defibrillation energy were occasionally inducible based on the arrhythmogenic substrate characterized as slowed conduction and prolonged repolarization of the ventricle.


Assuntos
Antiarrítmicos/administração & dosagem , Eletrocardiografia/métodos , Hipotermia Induzida/métodos , Fibrilação Ventricular/diagnóstico por imagem , Fibrilação Ventricular/terapia , Análise de Variância , Animais , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Eletrofisiologia Cardíaca/métodos , Modelos Animais de Doenças , Resistência a Medicamentos , Distribuição Aleatória , Medição de Risco , Suínos , Resultado do Tratamento
15.
Pacing Clin Electrophysiol ; 40(3): 223-231, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27943352

RESUMO

BACKGROUND: During bipolar (BIP) radiofrequency (RF) ablation using two catheters in humans, each catheter is placed in separate cardiac chambers or spaces. We developed a contact force-controlled experimental preparation, and compared measurements made with two catheters placed in a single bath (SB), versus each catheter placed in separate baths, in order to assess the preparation-dependent differences in the results of BIP-RF ablation. METHODS: In the SB experiments, a porcine heart was placed in the center of the bath, while in the dual-bath (DB) experiments, it was placed between two half baths communicating through windows. RESULTS: The initial impedance was greatest (110.5 ± 7.2 Ω) with the BIP-DB, followed by the BIP-SB (92.0 ± 5.6 Ω) and the unipolar (UNIP) DB (84.9 ± 4.7 Ω) configurations. During 50-W ablation for 60 seconds at a 20-g contact force, the root mean square voltage was 75.7 ± 2.5 V in the BIP-DB, 68.0 ± 2.1 V in the BIP-SB, and 66.8 ± 2.0 V in the UNIP-DB. The mean surface lesion diameters were similar among the three configurations. However, the endocardial lesion depth was 5.60 ± 0.56 mm with the BIP-DB, 4.71 ± 0.64 mm with the BIP-SB, and 4.24 ± 0.58 mm with the UNIP-DB configuration. On average, the endocardial lesions were significantly deeper than the epicardial ones. CONCLUSIONS: BIP ablation created much deeper lesions as compared to UNIP ablation. Lesion depth could be different depending on experimental preparation, and contact force-controlled DB preparation may be a much more appropriate model for studying the effects of BIP ablation.


Assuntos
Eletrodos , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Modelos Animais , Técnicas de Cultura de Órgãos/métodos , Cloreto de Sódio/química , Animais , Impedância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Pressão , Estresse Mecânico , Suínos
16.
J Electrocardiol ; 50(3): 277-281, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28238302

RESUMO

BACKGROUND: Patients with repetitive ventricular tachyarrhythmias - so-called electrical storm - frequently require antiarrhythmic drugs. Amiodarone is widely used for the treatment of electrical storm but is ineffective in some patients. Therefore, we investigated the efficacy of stepwise administration of nifekalant, a pure potassium channel blocker, and mexiletine for electrical storm. METHODS: This study included 44 patients with repetitive ventricular tachyarrhythmias who received stepwise therapy with nifekalant and mexiletine for electrical storm. Nifekalant was initially administered, and mexiletine was subsequently added if nifekalant failed to control ventricular tachyarrhythmias. RESULTS: Nifekalant completely suppressed recurrences of ventricular arrhythmias in 28 patients (64%), including 6 patients in whom oral amiodarone failed to control arrhythmias. In 9 of 16 patients in whom nifekalant was partially effective but failed to suppress ventricular arrhythmias, mexiletine was added. The addition of mexiletine prevented recurrences of ventricular tachyarrhythmias in 5 of these 9 patients (56%). There was no death associated with electrical storm. In total, the stepwise treatment with nifekalant and mexiletine was effective in preventing ventricular tachyarrhythmias in 33 of 44 patients (75%). There was no difference in cycle length of the ventricular tachycardia, QRS interval, QT interval, or left ventricular ejection fraction between patients who responded to antiarrhythmic drugs and those who did not. During follow-up, 8 patients had repetitive ventricular tachyarrhythmia recurrences, and the stepwise treatment was effective in 6 of these 8 patients (75%). CONCLUSIONS: The stepwise treatment with nifekalant and mexiletine was highly effective in the suppression of electrical storm.


Assuntos
Eletroencefalografia/efeitos dos fármacos , Mexiletina/administração & dosagem , Bloqueadores dos Canais de Potássio/administração & dosagem , Pirimidinonas/administração & dosagem , Bloqueadores dos Canais de Sódio/administração & dosagem , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/mortalidade , Administração Oral , Humanos , Japão/epidemiologia , Prevalência , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Taquicardia Ventricular/diagnóstico , Resultado do Tratamento
17.
Circ J ; 80(7): 1548-55, 2016 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-27251064

RESUMO

BACKGROUND: The proportion of patients with atrial fibrillation (AF) treated with anticoagulation varies from country to country. In Japan, little is known about regional differences in frequency of warfarin use or prognosis among patients with non-valvular AF (NVAF). METHODS AND RESULTS: In J-RHYTHM Registry, the number of patients recruited from each of 10 geographic regions of Japan was based on region population density. A total of 7,406 NVAF patients were followed up prospectively for 2 years. At baseline, significant differences in various clinical characteristics including age, sex, type of AF, comorbidity, and CHADS2score, were detected among the regions. The highest mean CHADS2score was recorded in Shikoku. Frequency of warfarin use differed between the regions (P<0.001), with lower frequencies observed in Hokkaido and Shikoku. Baseline prothrombin time international normalized ratio differed slightly but significantly between the regions (P<0.05). On univariate analysis, frequency of thromboembolic events differed among the regions (P<0.001), with the highest rate seen in Shikoku. An inverse correlation was detected between frequency of thromboembolic and of major hemorrhagic events (P=0.062). On multivariate analysis, region emerged as an independent risk for thromboembolism. CONCLUSIONS: Thromboembolic risk, frequency of warfarin use, and intensity and quality of warfarin treatment differed significantly between geographic regions of Japan. Region was found to be an independent predictor of thromboembolic events. (Circ J 2016; 80: 1548-1555).


Assuntos
Fibrilação Atrial/tratamento farmacológico , Sistema de Registros , Tromboembolia/tratamento farmacológico , Varfarina/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Humanos , Pessoa de Meia-Idade , Fatores de Risco , Tromboembolia/etiologia
20.
Heart Vessels ; 31(7): 1200-5, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26022375

RESUMO

A 73-year-old woman first visited our emergency room with multiple syncopal attacks. Before admission, she had received an antibiotic (Garenoxacin) for 3 days from a local clinic. First electrocardiogram (ECG) showed no ST-segment deviation but mild QT interval prolongation with a positive U wave. Second ECG recording 3 h later showed slightly slower heart rate and revealed marked QTU interval prolongation suggesting the cause of her syncopal attacks. After cessation of Garenoxacin, the QTU interval prolongation shortened. However, both epinephrine infusion and treadmill exercise test reproduced similar QTU interval prolongation and T wave deformities. Later, genetic analysis demonstrated that this patient had a mutation in KCNH2 gene, and she was diagnosed as a type-2 long-QT syndrome which was accentuated by use of garenoxacin. At the emergency out-patient clinic, repetitive ECG recordings can be useful and should be considered in order to identify the cause of syncopal attacks in patients who were prescribed antibiotics and had mild QT interval abnormalities.


Assuntos
Antibacterianos/efeitos adversos , Eletrocardiografia , Serviço Hospitalar de Emergência , Fluoroquinolonas/efeitos adversos , Frequência Cardíaca/efeitos dos fármacos , Síndrome do QT Longo/diagnóstico , Síncope/induzido quimicamente , Agonistas Adrenérgicos/administração & dosagem , Antagonistas de Receptores Adrenérgicos beta 1/uso terapêutico , Idoso , Canal de Potássio ERG1/genética , Epinefrina/administração & dosagem , Teste de Esforço , Feminino , Predisposição Genética para Doença , Humanos , Síndrome do QT Longo/complicações , Síndrome do QT Longo/tratamento farmacológico , Síndrome do QT Longo/genética , Síndrome do QT Longo/fisiopatologia , Metoprolol/uso terapêutico , Mutação , Fenótipo , Valor Preditivo dos Testes , Recidiva , Fatores de Risco , Síncope/diagnóstico , Síncope/fisiopatologia
SELEÇÃO DE REFERÊNCIAS