Circulation ; 134(8): 576-85, 2016 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-27496856

RESUMO

BACKGROUND: The ideal aortic valve substitute in young and middle-aged adults remains unknown. We sought to compare the long-term outcomes of patients undergoing the Ross procedure and those receiving a mechanical aortic valve replacement (AVR). METHODS: From 1990 to 2014, 258 patients underwent a Ross procedure and 1444 had a mechanical AVR at a single institution. Patients were matched into 208 pairs through the use of a propensity score. Mean age was 37.2±10.2 years, and 63% were male. Mean follow-up was 14.2±6.5 years. RESULTS: Overall survival was equivalent (Ross versus AVR: hazard ratio, 0.91, 95% confidence interval, 0.38-2.16; P=0.83), although freedom from cardiac- and valve-related mortality was improved in the Ross group (Ross versus AVR: hazard ratio, 0.22; 95% confidence interval, 0.034-0.86; P=0.03). Freedom from reintervention was equivalent after both procedures (Ross versus AVR: hazard ratio, 1.86; 95% confidence interval, 0.76-4.94; P=0.18). Long-term freedom from stroke or major bleeding was superior after the Ross procedure (Ross versus AVR: hazard ratio, 0.09; 95% confidence interval, 0.02-0.31; P<0.001). CONCLUSIONS: Long-term survival and freedom from reintervention were comparable between the Ross procedure and mechanical AVR. However, the Ross procedure was associated with improved freedom from cardiac- and valve-related mortality and a significant reduction in the incidence of stroke and major bleeding. In specialized centers, the Ross procedure represents an excellent option and should be considered for young and middle-aged adults undergoing AVR.


Assuntos
Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Pontuação de Propensão , Adolescente , Adulto , Insuficiência da Valva Aórtica/diagnóstico , Causas de Morte/tendências , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
2.
J Thorac Cardiovasc Surg ; 156(1): 5-13.e1, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29656818

RESUMO

OBJECTIVE: Whether the aortopathy associated with bicuspid aortic valve (BAV) disease occurs secondary to genetic or hemodynamic factors remains controversial. In this article we describe the natural history of the aortic root in patients with bicuspid versus tricuspid aortic valves (TAVs) after replacement of the aortic valve and ascending aorta. METHODS: From 1990 to 2010, 406 patients (269 BAV, 137 TAV) underwent aortic valve and ascending aorta replacement at a single institution. Patients with aortic dissection, endocarditis, previous aortic surgery, or Marfan syndrome were excluded. All available follow-up imaging was reviewed. RESULTS: Mean imaging follow-up was 5.5 (±5.3) years. Of all patients, 66.5% had at least 1 aortic root measurement after the index operation. Baseline aortic diameter was comparable between groups. In patients with BAV, aortic root diameter increased at a clinically negligible rate over time (0.654 mm per year; 95% confidence interval, 0.291-1.016; P < .001), similar to patients with TAV (P = .92). Mean clinical follow-up was 8.1 (±5.4) years. During follow-up, 18 patients underwent reoperation, 89% for a degenerated bioprosthetic aortic valve. Only 1 patient underwent reoperation for a primary indication of aortic aneurysmal disease, 22 years after the index operation. There were no differences in cumulative incidence rates of aortic reoperation (P = .14) between patients with BAV and TAV. CONCLUSIONS: Mid-term imaging after aortic valve and ascending aorta replacement indicates that if the aortic root is not dilated at the time of surgery, the risk of enlargement over time is minimal, negating the need for prophylactic root replacement in patients with BAV or TAV.


Assuntos
Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Valva Aórtica/anormalidades , Implante de Prótese Vascular , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Idoso , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/etiologia , Aneurisma Aórtico/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Implante de Prótese Vascular/efeitos adversos , Dilatação Patológica , Feminino , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento