Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 102(2): 318-327, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37354444

RESUMO

BACKGROUND: Transcatheter mitral valve implantation (TMVI) is a novel therapeutic option for treating symptomatic mitral valve disease. Evaluating patient anatomical suitability is a critical step in the TMVI screening process, but currently requires specialized software and computerized device models. AIMS: This analysis sought to assess the effectiveness of simple and standardized multislice computed tomography (MSCT) anatomic measurements for their ability to discriminate between patients who passed anatomical screening for Tendyne™ TMVI. METHODS: Subjects screened for the Tendyne Expanded Clinical Study from January 2016 through September 2019 were included. Core laboratory screening measurements included mitral annular (MA) dimensions at end-systole and end-diastole, simulated device implantation, and neo-left ventricular outflow tract (LVOT) area. Additionally, nine standard measurements of patient anatomy were assessed for their predictive value of patients passing the anatomic screening process. RESULTS: Out of 496 subjects screened for eligibility, 257 subjects met clinical eligibility criteria with MA dimensions within the manufacturer's suggested range: 153 (59.5%) underwent TMVI while 104 (40.5%) were excluded from the study for other anatomic reasons (76% due to risk of LVOT obstruction). CT-derived left ventricular end-systole diameter (LVESD) had the highest discriminatory power for predicting TMVI anatomical suitability (area under the curve of 0.908, p < 0.0001). The mitral inter-commissural (IC) dimension was best predictive of annular dimensions being within range, with dimensions <30 or >50 mm resulting in a negative predictive value of 94.4%. CONCLUSIONS: MSCT-derived mitral IC dimension and LVESD easily performed measures that are effective predictors of anatomical suitability or screen failure for this tether-based TMVI device.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco , Resultado do Tratamento
2.
Radiology ; 304(3): 542-550, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35638924

RESUMO

Background Arterial arteriosclerosis and atherosclerosis reflect vascular disease, the subclinical detection of which allows opportunity for cardiovascular disease (CVD) prevention. Larger cohort studies simultaneously quantifying anatomic thoracic and abdominal aortic pathologic abnormalities are lacking in the literature. Purpose To investigate the association of aortic wall area (AWA) and atherosclerotic plaque presence and burden as measured on MRI scans with incident CVD in a community sample. Materials and Methods In this prospective cohort study, participants in the Framingham Heart Study Offspring Cohort without prevalent CVD underwent 1.5-T MRI (between 2002-2005) of the descending thoracic and abdominal aorta with electrocardiogram-gated axial T2-weighted black-blood acquisitions. The wall thickness of the thoracic aorta was measured at the pulmonary bifurcation level and used to calculate the AWA as the difference between cross-sectional vessel area and lumen area. For primary or secondary analyses, multivariable Cox proportional hazards regression models were used to examine the association of aortic MRI measures with risk of first-incident CVD events or stroke and coronary heart disease, respectively. Results In 1513 study participants (mean age, 64 years ± 9 [SD]; 842 women [56%]), 223 CVD events occurred during follow-up (median, 13.1 years), of which 97 were major events (myocardial infarction, ischemic stroke, or CVD death). In multivariable analysis, thoracic AWA and prevalent thoracic plaque were associated with incident CVD (hazard ratio [HR], 1.20 per SD unit [95% CI: 1.05, 1.37] [P = .006] and HR, 1.63 [95% CI: 1.12, 2.35] [P = .01], respectively). AWA and prevalent thoracic plaque were associated with increased hazards: 1.32 (95% CI: 1.07, 1.62; P = .01) and 2.20 (95% CI: 1.28, 3.79; P = .005), for stroke and coronary heart disease, respectively. Conclusion In middle-aged community-dwelling adults, thoracic aortic wall area (AWA), plaque prevalence, and plaque volumes measured with MRI were independently associated with incident cardiovascular disease, with AWA associated in particular with stroke, and plaque associated with coronary heart disease. Clinical trial registration no. NCT00041418 © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Peshock in this issue.


Assuntos
Doenças Cardiovasculares , Doença das Coronárias , Infarto do Miocárdio , Placa Aterosclerótica , Acidente Vascular Cerebral , Idoso , Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/epidemiologia , Estudos Transversais , Feminino , Humanos , Incidência , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico por imagem , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/complicações
3.
Artigo em Inglês | MEDLINE | ID: mdl-36525386

RESUMO

INTRODUCTION: The EXTRACT-PE trial evaluated the safety and performance of the Indigo Aspiration System (Penumbra Inc.) with an 8F continuous mechanical aspiration thrombectomy system for the treatment of pulmonary embolism (PE). This subgroup analysis evaluates performance outcomes of patients with main pulmonary artery (PA) emboli versus discrete unilateral or bilateral PA emboli without main PA involvement. METHODS: The EXTRACT-PE trial was a prospective, single-arm, multicenter trial that enrolled 119 patients with acute submassive PE. Emboli location was collected at the time of enrollment, CT obstruction was measured and assessed by a Core Lab, and patients were grouped on whether emboli involved the main PA (with or without branch vessels) or not (branch vessels alone). Procedural device time, changes in the right ventricle to left ventricle (RV/LV) ratio, and systolic PA pressure from pre-and posttreatment were compared between the two groups. RESULTS: Out of the 119 patients enrolled, 118 had core lab-assessed clot locations. Forty-five (38.1%) had emboli that involved the main PA and 73 (61.9%) had only branch emboli. No significant difference was observed between these groups for 30-day mortality, procedural device time, changes in RV/LV ratio, reduction in CT Obstruction Index, or for systolic PA pressure from pre-and posttreatment. The mean absolute reduction in clot burden was significant in both groups. CONCLUSION: Continuous mechanical aspiration thrombectomy with the 8F Indigo Aspiration System was effective at improving clinical outcomes for submassive PE patients regardless of emboli location, and clot burden was significantly reduced in both groups.

4.
J Med Virol ; 93(4): 2513-2522, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33448439

RESUMO

Emerging evidence has underscored the potential usefulness of red blood cell distribution width (RDW) measurement in predicting the mortality and disease severity of COVID-19. This study aimed to assess the association of the plasma RDW levels with adverse prognosis in COVID-19 patients. A comprehensive literature search from inception to September 2020 was performed to harvest original studies reporting RDW on admission and clinical outcomes among patients hospitalized with COVID-19. RDW levels were compared between cases (patients who died or developed more severe symptoms) and controls (patients who survived or developed less severe symptoms). A total of 14,866 subjects from 10 studies were included in the meta-analysis. Higher levels of RDW were associated with adverse outcomes in COVID-19 patients (mean differences = 0.72; 95% CI = 0.47-0.97; I2 = 89.51%). Deceased patients had higher levels of RDW compared to patients who survived (mean differences = 0.93; 95% CI = 0.63-1.23; I2 = 85.58%). Severely ill COVID-19 patients showed higher levels of RDW, as opposed to patients classified to have milder symptoms (mean differences = 0.61; 95% CI = 0.28-0.94; I2 = 82.18%). Elevated RDW levels were associated with adverse outcomes in COVID-19 patients. This finding warrants further research on whether RDW could be utilized as a simple and reliable biomarker for predicting COVID-19 severity and whether RDW is mechanistically linked with COVID-19 pathophysiology.


Assuntos
COVID-19/sangue , COVID-19/mortalidade , Eritrócitos/patologia , Biomarcadores/sangue , COVID-19/virologia , Bases de Dados Factuais , Índices de Eritrócitos , Mortalidade Hospitalar , Humanos , Prognóstico , SARS-CoV-2/isolamento & purificação , Índice de Gravidade de Doença
5.
J Cardiovasc Magn Reson ; 20(1): 66, 2018 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-30231875

RESUMO

BACKGROUND: Left bundle branch block (LBBB) is associated with abnormal left ventricular (LV) contraction, and is frequently associated with co-morbid cardiovascular disease, but the effect of an isolated (i.e. in the absence of cardiovascular dissease) LBBB on biventricular volumes and ejection fraction (EF) is not well characterized. The objective of this study was to compare LV and right ventricular (RV) volumes and EF in adults with an isolated LBBB to matched healthy controls and to population-derived normative values, using cardiovascular magnetic resonance (CMR) imaging. METHODS: We reviewed our clinical echocardiography database and the Framingham Heart Study Offspring cohort CMR database to identify adults with an isolated LBBB. Age-, sex-, hypertension-status, and body-surface area (BSA)-matched controls were identified from the Offspring cohort. All study subjects were scanned using the same CMR hardware and imaging sequence. Isolated-LBBB cases were compared with matched controls using Wilcoxon paired signed-rank test, and to normative reference values via Z-score. RESULTS: Isolated-LBBB subjects (n = 18, 10F) ranged in age from 37 to 82 years. An isolated LBBB was associated with larger LV end-diastolic and end-systolic volumes (both p < 0.01) and lower LVEF (56+/- 7% vs. 68+/- 6%; p <0.001) with similar myocardial contraction fraction. LVEF in isolated LBBB was nearly two standard deviations (Z = - 1.95) below mean sex and age-matched group values. LV stroke volume, cardiac output, and mass, and all RV parameters were similar (p = NS) between the groups. CONCLUSIONS: Adults with an isolated LBBB have greater LV volumes and markedly reduced LVEF, despite the absence of overt cardiovascular disease. These data may be useful toward the clinical interpretation of imaging studies performed on patients with an isolated LBBB.


Assuntos
Bloqueio de Ramo/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Imageamento por Ressonância Magnética , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/complicações , Bloqueio de Ramo/fisiopatologia , Estudos de Casos e Controles , Bases de Dados Factuais , Feminino , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Valor Preditivo dos Testes , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
6.
Nephrol Dial Transplant ; 32(8): 1344-1350, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27325252

RESUMO

BACKGROUND: Total kidney volume (TKV) is an imaging biomarker that may have diagnostic and prognostic utility. The relationships between kidney volume, renal function and cardiovascular disease (CVD) have not been characterized in a large community-dwelling population. This information is needed to advance the clinical application of TKV. METHODS: We measured TKV in 1852 Framingham Heart Study participants (mean age 64.1 ± 9.2 years, 53% women) using magnetic resonance imaging. A healthy sample was used to define reference values. The associations between TKV, renal function and CVD risk factors were determined using multivariable logistic regression analysis. RESULTS: Overall, mean TKV was 278 ± 54 cm3 for women and 365 ± 66 cm3 for men. Risk factors for high TKV (>90% healthy referent size) were body surface area (BSA), diabetes, smoking and albuminuria, while age, female and estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2 were protective. Participants with high TKV had higher odds of diabetes [odds ratio (OR) 2.15, P < 0.001] and lower odds of eGFR <60 mL/min/1.73 m2 (OR 0.32, P = 0.007). Risk factors for low TKV (<10% healthy referent size) were age, female and eGFR <60 mL/min/1.73 m2, while BSA and diabetes were protective. Participants with low TKV had higher odds of eGFR <60 mL/min/1.73 m2 (OR 6.12, P < 0.001) and albuminuria (OR 1.56, P = 0.03). CONCLUSIONS: Low TKV is associated with markers of kidney damage including albuminuria and eGFR <60 mL/min/1.73 m2, while high TKV is associated with diabetes and decreased odds of eGFR <60 mL/min/1.73 m2. Prospective studies are needed to characterize the natural progression and clinical consequences of TKV.


Assuntos
Albuminúria/patologia , Doenças Cardiovasculares/complicações , Nefropatias/patologia , Rim/patologia , Idoso , Albuminúria/etiologia , Estudos de Casos e Controles , Estudos Transversais , Progressão da Doença , Feminino , Taxa de Filtração Glomerular , Humanos , Nefropatias/etiologia , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Prognóstico , Fatores de Risco
7.
J Magn Reson Imaging ; 41(4): 1038-45, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24817313

RESUMO

PURPOSE: To determine normative values for left ventricular (LV) volumes, mass, concentricity, and ejection fraction (EF) and investigate associations between sex, age, and body size with LV parameters in community-dwelling adults. MATERIALS AND METHODS: In all, 1794 Framingham Heart Study Offspring cohort members underwent LV short-axis oriented, contiguous multislice cine steady-state free precession MR of the left ventricle; from these a healthy referent group (n = 852, 61 ± 9 years, 40% men) free of clinical cardiac disease and hypertension (SBP < 140, DBP < 90 mmHg, never used antihypertensive medication ≥30 years prior to scanning) was identified. Referent participants were stratified by sex and age group (≤55, 56-65, >65 years); LV parameters were indexed to measures of body size. RESULTS: Men have greater LV volumes and mass than women both before and after indexation to height, powers of height, and body surface area (P < 0.01 all), but indexation to fat-free mass yielded greater LV volume and mass in women. In both sexes, LV volumes and mass decrease with advancing age, although indexation attenuates this association. LVEF is greater in women than men (68 ± 5% vs. 66 ± 5%, P < 0.01) and increases with age in both sexes (P < 0.05). CONCLUSION: Among nonhypertensive adults free of cardiac disease, men have greater LV volumes and mass with sex differences generally persisting after indexation to body size. LV volumes and mass tend to decrease with greater age in both sexes. Female sex and advanced age were both associated with greater LVEF. J. Magn. Reson. Imaging 2015;41:1038-1045. © 2014 Wiley Periodicals, Inc.


Assuntos
Envelhecimento/fisiologia , Tamanho Corporal/fisiologia , Ventrículos do Coração/anatomia & histologia , Imageamento por Ressonância Magnética/normas , Função Ventricular Esquerda/fisiologia , Antropometria/métodos , Biometria/métodos , Estudos de Coortes , Humanos , Tamanho do Órgão/fisiologia , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Caracteres Sexuais , Volume Sistólico , Estados Unidos
8.
Arterioscler Thromb Vasc Biol ; 34(7): 1580-6, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24833796

RESUMO

OBJECTIVE: The objective of this study was to determine the prevalence and risk factor (RF) correlates of aortic plaque (AP) detected by cardiovascular magnetic resonance (CMR), which mainly shows noncalcified plaques, and by noncontrast computed tomography (CT), which best depicts calcified plaques, in community-dwelling adults. APPROACH AND RESULTS: A total of 1016 Framingham Heart Study Offspring cohort members (64 ± 9 years; 474 men) underwent CMR and CT of the aorta. Potential RFs for AP (age; sex; body mass index; blood pressure; low-density lipoprotein and high-density lipoprotein cholesterol; fasting glucose; C-reactive protein; prevalent hypertension, diabetes mellitus, smoking; use of antihypertensive, diabetes mellitus, or lipid-lowering drugs) were compared between participants, with zero versus nonzero AP by CMR and by CT. Candidate RFs attaining P<0.05 for difference with either imaging modality were entered into multivariable logistic regression models adjusting for age, sex, and other RFs. Odds ratios were calculated for modality-specific prevalence of AP. Associations between RFs and continuous measures of AP were assessed using Tobit regression. Prevalence of CMR and CT AP was 49% and 82%, respectively. AP burdens by CMR and CT were correlated, r=0.28, P<0.0001. Increasing age and smoking were associated with prevalent AP by both CMR and CT. Additionally, prevalent AP by CMR was associated with female sex and fasting glucose and prevalent AP by CT with hypertension treatment and adverse lipid profile. CONCLUSIONS: AP by CMR and CT are both associated with smoking and increasing age, but other RFs differ between calcified and noncalcified AP. The relative predictive value of AP detected by CMR versus by CT for incident cardiovascular events remains to be determined.


Assuntos
Doenças da Aorta/epidemiologia , Aterosclerose/epidemiologia , Placa Aterosclerótica , Calcificação Vascular/epidemiologia , Fatores Etários , Idoso , Doenças da Aorta/diagnóstico , Aortografia/métodos , Aterosclerose/diagnóstico , Feminino , Humanos , Modelos Logísticos , Imageamento por Ressonância Magnética , Masculino , Massachusetts/epidemiologia , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Prevalência , Fatores de Risco , Fumar/efeitos adversos , Fumar/epidemiologia , Calcificação Vascular/diagnóstico
9.
J Magn Reson Imaging ; 39(4): 895-900, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24123369

RESUMO

PURPOSE: To determine sex-specific reference values for left ventricular (LV) volumes, mass, and ejection fraction (EF) in healthy adults using computer-aided analysis and to examine the effect of age on LV parameters. MATERIALS AND METHODS: We examined data from 1494 members of the Framingham Heart Study Offspring cohort, obtained using short-axis stack cine SSFP CMR, identified a healthy reference group (without cardiovascular disease, hypertension, or LV wall motion abnormality) and determined sex-specific upper 95th percentile thresholds for LV volumes and mass, and lower 5th percentile thresholds for EF using computer-assisted border detection. In secondary analyses, we stratified participants by age-decade and tested for linear trend across age groups. RESULTS: The reference group comprised 685 adults (423F; 61 ± 9 years). Men had greater LV volumes and mass, before and after indexation to common measures of body size (all P = 0.001). Women had greater EF (73 ± 6 versus 71 ± 6%; P = 0.0002). LV volumes decreased with greater age in both sexes, even after indexation. Indexed LV mass did not vary with age. LV EF and concentricity increased with greater age in both sexes. CONCLUSION: We present CMR-derived LV reference values. There are significant age and sex differences in LV volumes, EF, and geometry, whereas mass differs between sexes but not age groups.


Assuntos
Envelhecimento/fisiologia , Ventrículos do Coração/anatomia & histologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão/fisiologia , Reconhecimento Automatizado de Padrão/métodos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Circ Cardiovasc Imaging ; 17(2): e016090, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38377242

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) reference values are relied upon to accurately diagnose left ventricular (LV) and right ventricular (RV) pathologies. To date, reference values have been derived from modest sample sizes with limited patient diversity and attention to 1 but not both commonly used tracing techniques for papillary muscles and trabeculations. We sought to overcome these limitations by meta-analyzing normal reference values for CMR parameters stemming from multiple countries, vendors, analysts, and patient populations. METHODS: We comprehensively extracted published and unpublished data from studies reporting CMR parameters in healthy adults. A steady-state free-precession short-axis stack at 1.5T or 3T was used to trace either counting the papillary muscles and trabeculations in the LV volume or mass. We used a novel Bayesian hierarchical meta-analysis model to derive the pooled lower and upper reference values for each CMR parameter. Our model accounted for the expected differences between tracing techniques by including informative prior distributions from a large external data set. RESULTS: A total of 254 studies from 25 different countries were systematically reviewed, representing 12 812 healthy adults, of which 52 were meta-analyzed. For LV parameters counting papillary muscles and trabeculations in the LV volume, pooled normative reference ranges in men and women, respectively, were as follows: LV ejection fraction of 52% to 73% and 54% to 75%, LV end-diastolic volume index of 60 to 109 and 56 to 96 mL/m2, LV end-systolic volume index of 18 to 45 and 16 to 38 mL/m2, and LV mass index of 41 to 76 and 33 to 57 g/m2. For LV parameters counting papillary muscles and trabeculations in the LV mass, pooled normative reference ranges in men and women, respectively, were as follows: LV ejection fraction of 57% to 74% and 57% to 75%, LV end-diastolic volume index of 60 to 97 and 55 to 88 mL/m2, LV end-systolic volume index of 18 to 37 and 15 to 34 mL/m2, and LV mass index of 50 to 83 and 38 to 65 g/m2. For RV parameters, pooled normative reference ranges in men and women, respectively, were as follows: RV ejection fraction of 47% to 68% and 49% to 71%, RV end-diastolic volume index of 64 to 115 and 57 to 99 mL/m2, RV end-systolic volume index of 23 to 52 and 18 to 42 mL/m2, and RV mass index of 14 to 29 and 13 to 25 g/m2. CONCLUSIONS: Our Bayesian hierarchical meta-analysis provides normative reference values for CMR parameters of LV and RV size, systolic function, and mass, encompassing both tracing techniques across a diverse multinational sample of healthy men and women.


Assuntos
Ventrículos do Coração , Função Ventricular Esquerda , Adulto , Masculino , Humanos , Feminino , Valores de Referência , Teorema de Bayes , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico , Músculos Papilares , Espectroscopia de Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Reprodutibilidade dos Testes
11.
EuroIntervention ; 20(14): e887-e897, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007829

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is a therapeutic option for patients with severe mitral regurgitation (MR) who are ineligible for conventional surgery. There are limited data on the outcomes of large patient cohorts treated with TMVR. AIMS: This study aimed to investigate the outcomes and predictors of mortality for patients treated with transapical TMVR. METHODS: This analysis represents the clinical experience of all patients enrolled in the Tendyne Expanded Clinical Study. Patients with symptomatic MR underwent transapical TMVR with the Tendyne system between November 2014 and June 2020. Outcomes and adverse events up to 2 years, as well as predictors of short-term mortality, were assessed. RESULTS: A total of 191 patients were treated (74.1±8.0 years, 62.8% male, Society of Thoracic Surgeons Predicted Risk of Mortality 7.7±6.6%). Technical success was achieved in 96.9% (185/191), and there were no intraprocedural deaths. At 30-day, 1- and 2-year follow-up, the rates of all-cause mortality were 7.9%, 30.8% and 40.5%, respectively. Complete MR elimination (MR <1+) was observed in 99.3%, 99.1% and 96.3% of patients, respectively. TMVR treatment resulted in consistent improvement of New York Heart Association Functional Class and quality of life up to 2 years (both p<0.001). Independent predictors of early mortality were age (odds ratio [OR] 1.11; p=0.003), pulmonary hypertension (OR 3.83; p=0.007), and institutional experience (OR 0.40; p=0.047). CONCLUSIONS: This study investigated clinical outcomes in the full cohort of patients included in the Tendyne Expanded Clinical Study. The Tendyne TMVR system successfully eliminated MR with no intraprocedural deaths, resulting in an improvement in symptoms and quality of life. Continued refinement of clinical and echocardiographic risks will be important to optimise longitudinal outcomes.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/mortalidade , Masculino , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Idoso , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Resultado do Tratamento , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Próteses Valvulares Cardíacas , Fatores de Risco , Pessoa de Meia-Idade
12.
Am Heart J Plus ; 262023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36742989

RESUMO

Study Objective: Aortic arch geometry changes with age, including an increase in aortic arch width (AAW). High AAW is a predictor of incident adverse cardiovascular disease (CVD) events, but its distribution and determinants are unknown. We hypothesized that traditional CVD risk factors, in addition to age, are associated with increased AAW in community-dwelling adults. Study Design: Framingham Offspring and Third Generation cohort participants (N=3026, 52% Men) underwent thoracic multidetector computed tomography (MDCT). A referent group (733M, 738W) free of clinical CVD, hypertension, dyslipidemia, smoking, and diabetes was used to generate sex and 10-year age-group specific upper 90th percentile (P90) cut-points for AAW. AAW was measured as the distance between the cross-sectional centroids of the ascending and descending thoracic aorta. Multivariable logistic regression models were used to identify clinical correlates of high AAW (≥referent P90) in the overall study group. Results: Among referent participants, AAW increased with greater age-group, p for trend <0.0001 in each sex. Overall and within each age group, AAW was greater in men than women, p<0.0001 all comparisons. Across all participants, high AAW was associated with greater age (odds ratio, OR=1.34/10y; 95% confidence interval 1.20 - 1.50), body surface area (OR=1.97/SD; 1.62 - 2.40), diastolic blood pressure (OR=1.59/10mmHg; 1.40 - 1.81), pack-years smoked (OR=1.07; 1.02 - 1.13), and prevalent CVD (OR=1.64; 1.08 - 2.49). Conclusion: AAW increases with greater age, body size, diastolic blood pressure and burden of smoking. High AAW (≥referent P90) is also associated with prevalent (clinically apparent) CVD. AAW is often seen on and easily measured from tomographic thoracic images and has prognostic value.

13.
Clin Imaging ; 94: 79-84, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36495849

RESUMO

RATIONALE AND OBJECTIVES: Atherosclerosis of the aorta is associated with increased risk of cardiovascular mortality and vascular events. We aim to describe the prevalence and distribution of non-calcified atherosclerotic plaque in the descending aorta as quantified by noncontrast cardiovascular magnetic resonance (CMR) in a community-dwelling cohort of adults. MATERIALS AND METHODS: We used CMR to quantify noncalcified aortic plaque in 1726 participants (aged 65 ± 9 years, 46.7% men) from the Cohort Study Offspring cohort. ECG-gated, fat-suppressed, T2-weighted, black blood turbo spin echo sequence was used to acquire 36 transverse slices covering the descending aorta from just below the arch to the aortoiliac bifurcation. Plaque was defined as discrete luminal protrusions ≥1 mm; these were manually traced, then summed to determine total descending aortic plaque (DAP) and segmental thoracic and abdominal aortic plaque (TAP, AAP). Participants were stratified by sex and age group (<55, 55-64, 65-74, ≥75y). A healthy referent group (without clinical cardiovascular disease, smoking, diabetes, impaired renal function; (N = 768, 43.8% men) was used to determine upper 90th percentile cutpoints for DAP and AAP which were then applied to the overall study cohort. RESULTS: Prevalence of DAP was similar between men (47.3%) and women (48.9%), p = 0.50, as was AAP prevalence (men: 44.5%, women: 46.7%, p = 0.16); TAP was less prevalent in both sexes (men: 8.9%, women: 7.1%, p = 0.15). Both prevalence and burden of DAP, AAP and TAP increased with advancing age. CONCLUSION: Noncalcified plaque prevalence, visualized on CMR, in community-dwelling adults is similar between the sexes, and both prevalence and burden of aortic plaque increase with greater age.


Assuntos
Doenças da Aorta , Placa Aterosclerótica , Masculino , Adulto , Humanos , Feminino , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Estudos de Coortes , Prevalência , Vida Independente , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/epidemiologia , Fatores de Risco
14.
Magn Reson Med ; 67(5): 1478-86, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22021128

RESUMO

Quantitative analysis of short-axis functional cardiac magnetic resonance images can be performed using automatic contour detection methods. The resulting myocardial contours must be reviewed and possibly corrected, which can be time-consuming, particularly when performed across all cardiac phases. We quantified the impact of manual contour corrections on both analysis time and quantitative measurements obtained from left ventricular short-axis cine images acquired from 1555 participants of the Framingham Heart Study Offspring cohort using computer-aided contour detection methods. The total analysis time for a single case was 7.6 ± 1.7 min for an average of 221 ± 36 myocardial contours per participant. This included 4.8 ± 1.6 min for manual contour correction of 2% of all automatically detected endocardial contours and 8% of all automatically detected epicardial contours. However, the impact of these corrections on global left ventricular parameters was limited, introducing differences of 0.4 ± 4.1 mL for end-diastolic volume, -0.3 ± 2.9 mL for end-systolic volume, 0.7 ± 3.1 mL for stroke volume, and 0.3 ± 1.8% for ejection fraction. We conclude that left ventricular functional parameters can be obtained under 5 min from short-axis functional cardiac magnetic resonance images using automatic contour detection methods. Manual correction more than doubles analysis time, with minimal impact on left ventricular volumes and ejection fraction.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Disfunção Ventricular Esquerda/diagnóstico , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico
15.
Thromb Haemost ; 122(7): 1159-1168, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35717948

RESUMO

BACKGROUND: The efficacy and safety of pharmacological thromboprophylaxis in patients with intracerebral hemorrhage (ICH) remains unclear. METHODS: A literature search was performed to collect studies comparing the effect of thromboprophylaxis in patients with ICH. The primary endpoints were deep vein thrombosis (DVT), pulmonary embolism (PE), and hematoma expansion or rebleeding. A meta-analytic approach was employed to estimate the relative risk (RR) by fitting fixed-effects (FE) and random-effects (RE) models. RESULTS: A total of 28 studies representing 3,697 hospitalized patients with ICH were included. Thromboprophylaxis was initiated within 4 days following hospital presentation and continued for 10 to 14 days in most of studies. Compared with control, thromboprophylaxis was associated with a reduced risk of DVT (47/1,399 [3.4%] vs. 202/1,377 [14.7%]; FE: RR, 0.24; 95% CI, 0.18-0.32; RE: RR, 0.27; 95% CI, 0.19-0.39) as well as PE (9/953 [0.9%] vs. 37/864 [4.3%]; FE: RR, 0.33; 95% CI, 0.19-0.57; RE: RR, 0.37; 95% CI, 0.21-0.66). Thromboprophylaxis was not associated with increased risk of hematoma expansion or rebleeding (32/1,319 [2.4%] vs. 37/1,301 [2.8%]; FE: RR, 0.75; 95% CI, 0.48-1.18; RE: RR, 0.80; 95% CI, 0.49-1.30) or mortality (117/925 [12.6%] vs. 139/904 [15.4%]; FE: RR, 0.82; 95% CI, 0.65-1.03; RE: RR, 0.83; 95% CI, 0.66-1.04). CONCLUSION: Thromboprophylaxis was effective in preventing DVT and PE without increasing the risk of hematoma expansion or bleeding among ICH patients. Future studies should explore the long-term effects of thromboprophylaxis in this population, particularly on the functional outcomes.


Assuntos
Embolia Pulmonar , Tromboembolia Venosa , Trombose Venosa , Anticoagulantes/efeitos adversos , Hemorragia Cerebral/tratamento farmacológico , Hematoma/induzido quimicamente , Hematoma/complicações , Heparina/efeitos adversos , Heparina de Baixo Peso Molecular/uso terapêutico , Humanos , Embolia Pulmonar/complicações , Embolia Pulmonar/prevenção & controle , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/tratamento farmacológico , Tromboembolia Venosa/etiologia , Trombose Venosa/tratamento farmacológico , Trombose Venosa/etiologia , Trombose Venosa/prevenção & controle
16.
Magn Reson Med ; 66(6): 1674-81, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21671266

RESUMO

Prospective right hemidiaphragm navigator (NAV) is commonly used in free-breathing coronary MRI. The NAV results in an increase in acquisition time to allow for resampling of the motion-corrupted k-space data. In this study, we are presenting a joint prospective-retrospective NAV motion compensation algorithm called compressed-sensing motion compensation (CosMo). The inner k-space region is acquired using a prospective NAV; for the outer k-space, a NAV is only used to reject the motion-corrupted data without reacquiring them. Subsequently, those unfilled k-space lines are retrospectively estimated using compressed sensing reconstruction. We imaged right coronary artery in nine healthy adult subjects. An undersampling probability map and sidelobe-to-peak ratio were calculated to study the pattern of undersampling, generated by NAV. Right coronary artery images were then retrospectively reconstructed using compressed-sensing motion compensation for gating windows between 3 and 10 mm and compared with the ones fully acquired within the gating windows. Qualitative imaging score and quantitative vessel sharpness were calculated for each reconstruction. The probability map and sidelobe-to-peak ratio show that the NAV generates a random undersampling k-space pattern. There were no statistically significant differences between the vessel sharpness and subjective score of the two reconstructions. Compressed-sensing motion compensation could be an alternative motion compensation technique for free-breathing coronary MRI that can be used to reduce scan time.


Assuntos
Artefatos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Vasos Coronários/anatomia & histologia , Compressão de Dados/métodos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Adulto , Algoritmos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
J Magn Reson Imaging ; 33(5): 1248-55, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21509886

RESUMO

PURPOSE: To investigate the efficacy of distributed compressed sensing (CS) to accelerate free-breathing, electrocardiogram (ECG)-triggered noncontrast pulmonary vein (PV) magnetic resonance angiography (MRA). MATERIALS AND METHODS: Fully sampled ECG-triggered noncontrast PV MRA, using a spatially selective slab inversion preparation sequence, was acquired on seven healthy adult subjects (27 ± 17 years, range: 19-65 years, 4 women). The k-space data were retrospectively randomly undersampled by factors of 2, 4, 6, 8, and 10 and then reconstructed using distributed CS and coil-by-coil CS methods. The reconstructed images were evaluated by two blinded readers in consensus for assessment of major PV branches as well as the presence of artifacts in left atrium (LA) and elsewhere. Diameters of right inferior and right superior PV branches were measured. Additionally, mean square errors (MSE) of the reconstructions were calculated. RESULTS: Both CS methods resulted in image quality scores similar to the fully sampled reference images at undersampling factors up to 6-fold for distributed CS and 4-fold for coil-by-coil CS reconstructions. There was no difference in the presence of artifacts in LA and freedom from important artifacts elsewhere between the two techniques up to undersampling factors of 10 compared to the fully sampled reconstruction. For the PV diameters, no systematic variation between the reference and the reconstructions were observed for either technique. There were no significant differences in MSE between the two methods when compared at a given rate, but the difference was significant when compared across all rates. CONCLUSION: The sparsity of noncontrast PV MRA and the joint sparsity of different coil images allow imaging at high undersampling factors (up to 6-fold) when distributed CS is used.


Assuntos
Angiografia por Ressonância Magnética/métodos , Veias Pulmonares/patologia , Adulto , Idoso , Algoritmos , Eletrocardiografia/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos
18.
JACC Cardiovasc Interv ; 14(3): 319-329, 2021 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-33454291

RESUMO

OBJECTIVES: This study sought to prospectively evaluate the safety and efficacy of the Indigo aspiration system in submassive acute pulmonary embolism (PE). BACKGROUND: PE treatment with thrombolytics has bleeding risks. Aspiration thrombectomy can remove thrombus without thrombolytics, but data are lacking. METHODS: This study was a prospective, single-arm, multicenter study that enrolled patients with symptomatic acute PE ≤14 days, systolic blood pressure ≥90 mm Hg, and right ventricular-to-left ventricular (RV/LV) ratio >0.9. The primary efficacy endpoint was change in RV/LV ratio from baseline to 48 h post-procedure on core lab-adjudicated computed tomography angiography. The primary safety endpoint was a composite of 48-h major adverse events: device-related death, major bleeding, and device-related serious adverse events (clinical deterioration, pulmonary vascular, or cardiac injury). All sites received Institutional Review Board approval. RESULTS: A total of 119 patients (mean age 59.8 ± 15.0 years) were enrolled at 22 U.S. sites between November 2017 and March 2019. Median device insertion to removal time was 37.0 (interquartile range: 23.5 to 60.0) min. Two (1.7%) patients received intraprocedural thrombolytics. Mean RV/LV ratio reduction from baseline to 48 h post-procedure was 0.43 (95% confidence interval: 0.38 to 0.47; p < 0.0001). Two (1.7%) patients experienced 3 major adverse events. Rates of cardiac injury, pulmonary vascular injury, clinical deterioration, major bleeding, and device-related death at 48 h were 0%, 1.7%, 1.7%, 1.7%, and 0.8%, respectively. CONCLUSIONS: In this prospective, multicenter study the Indigo aspiration system was associated with a significant reduction in the RV/LV ratio and a low major adverse event rate in submassive PE patients. Intraprocedural thrombolytic drugs were avoided in 98.3% of patients. (Evaluating the Safety and Efficacy of the Indigo aspiration system in Acute Pulmonary Embolism [EXTRACT-PE]; NCT03218566).


Assuntos
Embolia Pulmonar , Doença Aguda , Adulto , Idoso , Fibrinolíticos/uso terapêutico , Humanos , Índigo Carmim/uso terapêutico , Pessoa de Meia-Idade , Estudos Prospectivos , Embolia Pulmonar/tratamento farmacológico , Terapia Trombolítica , Resultado do Tratamento
19.
JACC Cardiovasc Imaging ; 14(8): 1644-1658, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33744155

RESUMO

A plethora of catheter-based strategies have been developed to treat mitral valve disease. Evolving 3-dimensional (3D) multidetector computed tomography (MDCT) technology can accurately reconstruct the mitral valve by means of 3-dimensional computational modeling (3DCM) to allow virtual implantation of catheter-based devices. 3D printing complements computational modeling and offers implanting physician teams the opportunity to evaluate devices in life-size replicas of patient-specific cardiac anatomy. MDCT-derived 3D computational and 3D-printed modeling provides unprecedented insights to facilitate hands-on procedural planning, device training, and retrospective procedural evaluation. This overview summarizes current concepts and provides insight into the application of MDCT-derived 3DCM and 3D printing for the planning of transcatheter mitral valve replacement and closure of paravalvular leaks. Additionally, future directions in the development of 3DCM will be discussed.


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Estudos Retrospectivos
20.
J Am Coll Cardiol ; 78(19): 1847-1859, 2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34736561

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is feasible for selected patients with severe mitral regurgitation (MR) who are poor candidates for valve surgery. Intermediate-term to long-term TMVR outcomes have not been reported. OBJECTIVES: This study sought to evaluate the safety and effectiveness through 2-year follow-up of TMVR in high-surgical-risk patients with severe MR. METHODS: The first 100 patients enrolled in the Expanded Clinical Study of the Tendyne Mitral Valve System, an open-label, nonrandomized, prospective study of transapical TMVR, were followed for 2 years. RESULTS: The patients (aged 74.7 ± 8.0 years, 69.0% male) had symptomatic (66.0% New York Heart Association [NYHA] functional class III or IV) grade 3+ or 4+ MR that was secondary or mixed in 89 (89.0%). Prostheses were successfully implanted in 97 (97.0%) patients. At 2 years, all-cause mortality was 39.0%; 17 (43.6%) of 39 deaths occurred during the first 90 days. Heart failure hospitalization (HFH) fell from 1.30 events per year preprocedure to 0.51 per year in the 2 years post-TMVR (P < 0.0001). At 2 years, 93.2% of surviving patients had no MR. No patient had >1+ MR. The improvement in symptoms at 1 year (88.5% NYHA functional class I or II) was sustained to 2 years (81.6% NYHA functional class I or II). Among survivors, the left ventricular ejection fraction was 45.6 ± 9.4% at baseline and 39.8 ± 9.5% at 2 years (P = 0.0012). Estimated right ventricular systolic pressure decreased from 47.6 ± 8.6 mm Hg to 32.5 ± 10.4 mm Hg (P < 0.005). CONCLUSIONS: In this study, the impact of TMVR on severity of MR, reduction in HFH rate, and improvement in symptoms was sustained through 2 years. All-cause mortality and the need for HFH was highest in the first 3 months postprocedure. (Expanded Clinical Study of the Tendyne Mitral Valve System; NCT02321514).


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Efeitos Adversos de Longa Duração/mortalidade , Insuficiência da Valva Mitral , Valva Mitral , Complicações Pós-Operatórias , Disfunção Ventricular Esquerda , Idoso , Ecocardiografia/métodos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA