Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
G Ital Cardiol (Rome) ; 19(9): 519-529, 2018 Sep.
Artigo em Italiano | MEDLINE | ID: mdl-30087514

RESUMO

Transcatheter aortic valve implantation (TAVI) has revolutionized the management of patients with symptomatic severe aortic stenosis and has become the standard of care for inoperable patients and the preferred therapy for those at increased surgical risk with peculiar clinical and anatomic features. Technology advances, growing experience and accumulating data prompted the update of the 2011 Italian Society of Interventional Cardiology (SICI-GISE) position paper on institutional and operator requirements to perform TAVI. The main objective of this document is to provide a guidance to assess the potential of institutions and operators to initiate and maintain an efficient TAVI program.


Assuntos
Estenose da Valva Aórtica/cirurgia , Desenvolvimento de Programas/métodos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/fisiopatologia , Tecnologia Biomédica/tendências , Humanos , Itália , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/instrumentação
2.
J Cardiovasc Med (Hagerstown) ; 10(2): 212-4, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19377387

RESUMO

In patients with acute aortic dissection, an early diagnosis is essential to anticipate aortic rupture, cardiac tamponade, organ ischemia and improve surgical results. A specific blood laboratory marker able to rule out the presence of aortic dissection has not been identified yet. Recently, several studies suggested using D-dimers as a negative predicting test to rule out diagnosis of acute aortic dissection in patients presenting with chest pain. In 61 patients with confirmed aortic dissection, preoperative D-dimers were assayed and correlated with time from symptom onset and extension of the false lumen dissection (according with De Bakey classification). Abnormal D-dimers values were considered those being greater than 400 microg/l. D-dimers values were above 400 microg/l in 50 patients (82%) and below 400 microg/l in 11 patients (18%). There was no correlation between preoperative D-dimers values and time from symptoms onset (r = -0.232; P = 0.1). We found that D-dimers are not always elevated in patients presenting with acute aortic dissection. Given the potential devastating effects of denying the diagnosis of acute aortic dissection with consequent delay of adequate treatment, a word of caution regarding the negative predictive value of D-dimer test in the diagnosis of aortic dissection seems warranted.


Assuntos
Aneurisma Aórtico/diagnóstico , Dissecção Aórtica/diagnóstico , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Doença Aguda , Adulto , Idoso , Dissecção Aórtica/sangue , Dissecção Aórtica/complicações , Aneurisma Aórtico/sangue , Aneurisma Aórtico/complicações , Biomarcadores/sangue , Dor no Peito/sangue , Dor no Peito/etiologia , Reações Falso-Negativas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Regulação para Cima
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA