Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Pediatr Gastroenterol Nutr ; 75(5): e98-e105, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35930026

RESUMO

OBJECTIVES: High manganese (Mn) levels during fetal growth or prolonged parenteral nutrition (PN) may have adverse effects on neurodevelopment. We aim to report on Mn levels and their short-term impact on clinical course in very low birth weight infants. METHODS: An observational study including newborns with a gestational age (GA) ≤32 weeks and/or ≤1500 g of birth weight (BW). Newborns received intravenous supplementation of Mn at 1 µg/kg/day (Peditrace ® ) in PN and continued with fortified breast milk. Mothers answered surveys about dietary and other habits and blood levels of Mn in newborns were analyzed at days 1, 15, and 30 of life. Associations of Mn levels with mothers' and newborns' data were evaluated and adjusted for multiple comparisons. RESULTS: One hundred and sixty premature infants were recruited. Median blood Mn levels at birth were 43.0 and 24.5 µg/L at day 30. No important association with mothers' data was found. Median [interquartile range (IQR)] duration of PN was 8 days (7-14). A prolonged PN and late oral feeding showed a nonsignificant association with lower blood Mn levels at day 30 ( P = 0.010, P threshold 0.003). Mn levels at day 15 and 30 were associated with increasing GA ( P < 0.001). Low Mn was not a significant predictor of adverse outcomes such as retinopathy of prematurity, bronchopulmonary dysplasia, or respiratory distress syndrome after adjusting for potential confounders and multiple testing. CONCLUSIONS: Mn showed lower levels with decreasing GA and prolonged PN. Using a low Mn PN solution may not raise blood Mn levels in premature infants.


Assuntos
Doenças do Prematuro , Manganês , Lactente , Feminino , Recém-Nascido , Humanos , Recém-Nascido de muito Baixo Peso , Recém-Nascido Prematuro , Nutrição Parenteral/efeitos adversos , Idade Gestacional , Doenças do Prematuro/etiologia , Peso ao Nascer
2.
J Matern Fetal Neonatal Med ; 34(16): 2754-2757, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31575302

RESUMO

BACKGROUND: Newborns diagnosed with craniofacial malformations or laryngeal and tracheal alterations may often need advanced airway-management for airway stabilization. Although fiberoptic bronchoscopy (FB) is currently the gold standard for difficult airway management, there is a scarcity of published data on the application of FB in newborns for intubation and controlled extubation (CE). OBJECTIVES: This study describes a case series where FB is used for intubation and/or extubation to manage newborns with difficult airway in either urgent procedures or scheduled ones. METHODS: All FB were carried out on newborns with difficult airway in the neonatal unit over the period January 2005 to December 2018. Patient characteristics were collected from clinical reports, description of the technique from the procedure report. RESULTS: 66 FBs were performed from a total of 40 newborns, a median age of 25 days and a weight of 3217 g. Eighteen were ex-premature babies (45%). Six (15%) had craniocervical malformations. 17 (25.7%) FBs were performed for tracheal intubation (TI), 6 in emergency situations, 34 (51.5%) for CE, and 15 (22.7%) for precise tube placement. Clearing of the airway was achieved in all cases and thus there were no failed TIs. In 32 cases (94.1%), CE was successfully performed. In 6 cases, withdrawal of the ET midprocedure was decided to postpone as 4 of these required extra treatment prior to renewed extubation attempt and 2 needed a tracheostomy. 2 patients required subsequent FB reintubation due to airway pathology. Complications during the procedure were mild desaturations (3%) and deep desaturations (7.5%). CONCLUSIONS: FB is very safe and highly useful when performing intubation in neonates with difficult airway but is essential during extubation to avoid any risk of failure with a potentially fatal outcome. Neonatal units of tertiary hospitals should provide equipment and training to manage these neonates. WHAT IS ALREADY KNOWN?: A failed intubation or extubation can lead to cardiac arrest and anoxic brain damage and/or to death in a neonate. Fiberoptic bronchoscopy is recommended as the safest tool for neonates with difficult airway. However, there is little concrete data published in the current literature to support the recommendations. WHAT IS NEW: Fiberoptic bronchoscopy is an essential tool to avoid the risk of a failed extubation in neonates with difficult airway.


Assuntos
Broncoscopia , Intubação Intratraqueal , Extubação , Humanos , Lactente , Recém-Nascido , Intubação Intratraqueal/efeitos adversos , Traqueia , Traqueostomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA