Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 31(7): 5189-5197, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33409792

RESUMO

OBJECTIVES: Radiofrequency ablation (RFA) is effective in reducing the volume of benign thyroid nodules. However, what parameters can influence the response to RFA is still unclear. The present study aimed to (1) investigate which ultrasound and technical parameters are potential determinants of the volumetric reduction; (2) develop a dose-response model, and (3) analyze the effects of RFA on ultrasound features. METHODS: In this retrospective study, three institutions treated patients with benign thyroid nodules according to the same protocol. The technical parameters were power and energy. The 1-year volume reduction ratio (VRR) was the reference standard of the response. The correlations of different parameters with VRR were analyzed and the association between several parameters and a VRR above 50% studied by uni- and multivariate analyses. The probit regression estimated the probability to achieve an effective response. RESULTS: One hundred fifteen patients were enrolled. The median power was 50 W and median total delivered energy 27,531 J. At 1-year follow-up, the median VRR was 64.0% and 87 (75.7%) nodules showed a VRR above 50%. Among all parameters, only baseline volume, total energy, and energy per volume were independently associated to a VRR > 50% (p = 0.001, p = 0.0178, p < 0.001 respectively). The probit regression analysis demonstrated that delivering 756 J/ml and 2670 J/ml gave a probability of VRR > 50% in 50% and 99% of patients, respectively. CONCLUSIONS: Considering the baseline nodular volume and delivering the adequate energy per volume allow optimizing technical and clinical success. KEY POINTS: • The effectiveness of radiofrequency ablation in treating benign thyroid nodules is negatively correlated to the volume of the nodule and positively correlated to the energy delivered per volume. • When planning the treatment, the total energy to deliver can be calculated by using a simple formula: nodular volume × 2670 J.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Nódulo da Glândula Tireoide , Humanos , Estudos Retrospectivos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/cirurgia , Resultado do Tratamento , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA