Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 196
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38939955

RESUMO

BACKGROUND: Despite major advances in the clinical management of long QT syndrome, some patients are not fully protected by beta-blocker therapy. Mexiletine is a well-known sodium channel blocker, with proven efficacy in patients with sodium channel-mediated long QT syndrome type 3. Our aim was to evaluate the efficacy of mexiletine in long QT syndrome type 2 (LQT2) using cardiomyocytes derived from patient-specific human induced pluripotent stem cells, a transgenic LQT2 rabbit model, and patients with LQT2. METHODS: Heart rate-corrected field potential duration, a surrogate for QTc, was measured in human induced pluripotent stem cells from 2 patients with LQT2 (KCNH2-p.A561V, KCNH2-p.R366X) before and after mexiletine using a multiwell multi-electrode array system. Action potential duration at 90% repolarization (APD90) was evaluated in cardiomyocytes isolated from transgenic LQT2 rabbits (KCNH2-p.G628S) at baseline and after mexiletine application. Mexiletine was given to 96 patients with LQT2. Patients were defined as responders in the presence of a QTc shortening ≥40 ms. Antiarrhythmic efficacy of mexiletine was evaluated by a Poisson regression model. RESULTS: After acute treatment with mexiletine, human induced pluripotent stem cells from both patients with LQT2 showed a significant shortening of heart rate-corrected field potential duration compared with dimethyl sulfoxide control. In cardiomyocytes isolated from LQT2 rabbits, acute mexiletine significantly shortened APD90 (∆APD shortening 113 ms), indicating a strong mexiletine-mediated shortening across different LQT2 model systems. Mexiletine was given to 96 patients with LQT2 either chronically (n=60) or after the acute oral drug test (n=36): 65% of the patients taking mexiletine only chronically and 75% of the patients who performed the acute oral test were responders. There was a significant correlation between basal QTc and ∆QTc during the test (r= -0.8; P<0.001). The oral drug test correctly predicted long-term effect in 93% of the patients. Mexiletine reduced the mean yearly event rate from 0.10 (95% CI, 0.07-0.14) to 0.04 (95% CI, 0.02-0.08), with an incidence rate ratio of 0.40 (95% CI, 0.16-0.84), reflecting a 60% reduction in the event rate (P=0.01). CONCLUSIONS: Mexiletine significantly shortens cardiac repolarization in LQT2 human induced pluripotent stem cells, in the LQT2 rabbit model, and in the majority of patients with LQT2. Furthermore, mexiletine showed antiarrhythmic efficacy. Mexiletine should therefore be considered a valid therapeutic option to be added to conventional therapies in higher-risk patients with LQT2.

2.
Eur Heart J ; 45(14): 1269-1277, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38546408

RESUMO

BACKGROUND AND AIMS: Bloodstream infection (BSI) of any cause may lead to device infection in cardiac implantable electronic device (CIED) patients. Aiming for a better understanding of the diagnostic approach, treatment, and outcome, patients with an implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy and defibrillator (CRT-D) hospitalized with BSI were investigated. METHODS: This is a single-centre, retrospective, cohort analysis including consecutive ICD/CRT-D patients implanted between 2012 and 2021. These patients were screened against a list of all hospitalized patients having positive blood cultures consistent with diagnosed infection in any department of a local public hospital. RESULTS: The total cohort consisted of 515 patients. Over a median follow-up of 59 months (interquartile range 31-87 months), there were 47 BSI episodes in 36 patients. The majority of patients with BSI (92%) was admitted to non-cardiology units, and in 25 episodes (53%), no cardiac imaging was performed. Nearly all patients (85%) were treated with short-term antibiotics, whereas chronic antibiotic suppression therapy (n = 4) and system extraction (n = 3) were less frequent. Patients with BSI had a nearly seven-fold higher rate (hazard ratio 6.7, 95% confidence interval 3.9-11.2; P < .001) of all-cause mortality. CONCLUSIONS: Diagnostic workup of defibrillator patients with BSI admitted to a non-cardiology unit is often insufficient to characterize lead-related endocarditis. The high mortality rate in these patients with BSI may relate to underdiagnosis and consequently late/absence of system removal. Efforts to increase an interdisciplinary approach and greater use of cardiac imaging are necessary for timely diagnosis and adequate treatment.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Sepse , Humanos , Estudos Retrospectivos , Desfibriladores Implantáveis/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Antibacterianos/uso terapêutico , Sepse/etiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Resultado do Tratamento
3.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38445836

RESUMO

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Adulto
4.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38363995

RESUMO

Ventricular tachycardia (VT), and its occurrence, is still one of the main reasons for sudden cardiac death and, therefore, for increased mortality and morbidity foremost in patients with structural heart [Kahle A-K, Jungen C, Alken F-A, Scherschel K, Willems S, Pürerfellner H et al. Management of ventricular tachycardia in patients with ischaemic cardiomyopathy: contemporary armamentarium. Europace 2022;24:538-51]. Catheter ablation has become a safe and effective treatment option in patients with recurrent VT [Cronin EM, Bogun FM, Maury P, Peichl P, Chen M, Namboodiri N et al. 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. Heart Rhythm 2020;17:e2-154]. Previous and current guidelines provide guidance on indication for VT ablation and risk assessment and evaluation of underlying disease. However, no uniform recommendation is provided regarding procedural strategies, timing of ablation, and centre setting. Therefore, these specifics seem to differ largely, and recent data are sparse. This physician-based European Heart Rhythm Association survey aims to deliver insights on not only infrastructural settings but also procedural specifics, applied technologies, ablation strategies, and procedural endpoints. Therefore, these findings might deliver a real-world scenario of VT management and potentially are of guidance for other centres.


Assuntos
Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Fluxo de Trabalho , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Resultado do Tratamento , Ablação por Cateter/métodos
5.
Europace ; 25(2): 682-687, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36413604

RESUMO

With the increasing interest in conduction system pacing (CSP) over the last few years and the inclusion of this treatment modality in the current guidelines, our aim was to provide a snapshot of current practice across Europe. An online questionnaire was sent to physicians participating in the European Heart Rhythm Association research network as well as to national societies and over social media. Data on previous experience with CSP, current indications, preferred tools, unmet needs, and perceptions for the future are reported and discussed.


Assuntos
Fascículo Atrioventricular , Sistema de Condução Cardíaco , Humanos , Doença do Sistema de Condução Cardíaco , Inquéritos e Questionários , Europa (Continente) , Estimulação Cardíaca Artificial , Eletrocardiografia
6.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37944131

RESUMO

AIMS: Brugada syndrome (BrS) is an inherited disease associated with an increased risk of ventricular arrhythmias. Recent studies have reported the presence of an altered atrial phenotype characterized by abnormal P-wave parameters. The aim of this study was to identify BrS based exclusively on P-wave features through an artificial intelligence (AI)-based model. METHODS AND RESULTS: Continuous 5 min 12-lead ECG recordings were obtained in sinus rhythm from (i) patients with spontaneous or ajmaline-induced BrS and no history of AF and (ii) subjects with suspected BrS and negative ajmaline challenge. The recorded ECG signals were processed and divided into epochs of 15 s each. Within these epochs, P-waves were first identified and then averaged. From the averaged P-waves, a total of 67 different features considered relevant to the classification task were extracted. These features were then used to train nine different AI-based supervised classifiers. A total of 2228 averaged P-wave observations, resulting from the analysis of 33 420 P-waves, were obtained from 123 patients (79 BrS+ and 44 BrS-). Averaged P-waves were divided using a patient-wise split, allocating 80% for training and 20% for testing, ensuring data integrity and reducing biases in AI-based model training. The BrS+ patients presented with longer P-wave duration (136 ms vs. 124 ms, P < 0.001) and higher terminal force in lead V1 (2.5 au vs. 1.7 au, P < 0.01) compared with BrS- subjects. Among classifiers, AdaBoost model had the highest values of performance for all the considered metrics, reaching an accuracy of over 81% (sensitivity 86%, specificity 73%). CONCLUSION: An AI machine-learning model is able to identify patients with BrS based only on P-wave characteristics. These findings confirm the presence of an atrial hallmark and open new horizons for AI-guided BrS diagnosis.


Assuntos
Fibrilação Atrial , Síndrome de Brugada , Humanos , Fibrilação Atrial/induzido quimicamente , Inteligência Artificial , Ajmalina/efeitos adversos , Eletrocardiografia/métodos
7.
Europace ; 25(8)2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-37622577

RESUMO

In the early nineties, few years before the birth of Europace, the clinical and scientific world of familial arrhythmogenic conditions was revolutionized by the identification of the first disease-causing genes. The explosion of genetic studies over a 15-year period led to the discovery of major disease-causing genes in practically all channelopathies and cardiomyopathies, bringing insight into the pathophysiological mechanisms of these conditions. The birth of next generation sequencing allowed a further step forward and other significant genes, as CALM1-3 in channelopathies and FLN C and TTN in cardiomyopathies were identified. Genotype-phenotype studies allowed the implementation of the genetic results in diagnosis, risk stratification, and therapeutic management with a different level of evidence in different arrhythmogenic conditions. The influence of common genetic variants, i.e. SNPs, on disease manifestation was proved in mid-twenties, and in the last 10 years with the advent of genome-wide association studies performed in familial arrhythmogenic diseases, the concept of polygenic risk score has been consolidated. Now, we are at the start of another amazing phase, i.e. the initiation of first gene therapy clinical trials.


Assuntos
Cardiomiopatias , Canalopatias , Humanos , Canalopatias/diagnóstico , Canalopatias/genética , Canalopatias/terapia , Estudo de Associação Genômica Ampla , Cardiomiopatias/diagnóstico , Cardiomiopatias/genética , Cardiomiopatias/terapia , Cognição , Sequenciamento de Nucleotídeos em Larga Escala
8.
Europace ; 25(2): 667-675, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36512365

RESUMO

Catheter ablation (CA) of atrial fibrillation (AF) is the therapy of choice for the maintenance of sinus rhythm in patients with symptomatic AF. Time towards interventional treatment and peri-procedural management of patients undergoing AF ablation may vary in daily practice. The scope of this European Heart Rhythm Association (EHRA) survey was to report the current clinical practice regarding the management of patients undergoing AF ablation and physician's adherence to the European Society of Cardiology Guidelines and the EHRA/HRS/ECAS expert consensus statement on the CA for AF. This physician-based survey was conducted among EHRA members, using an internet-based questionnaire developed by the EHRA Scientific Initiatives Committee. A total of 258 physicians participated in the survey. In patients with paroxysmal or persistent AF, 42 and 9% of the physicians would routinely perform AF ablation as first-line therapy respectively, whereas 71% of physicians would consider ablation as first-line therapy in patients with symptomatic AF and left ventricular ejection fraction <35%. Only 14% of the respondents manage cardiovascular risk factors in patients referred for CA using a dedicated AF risk factor management programme. Radiofrequency CA is the preferred technology for first-time AF (56%), followed by cryo-balloon CA (40%). This EHRA survey demonstrated a considerable variation in the management of patients undergoing AF ablation in routine practice and deviations between guideline recommendations and clinical practice.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Seleção de Pacientes , Volume Sistólico , Função Ventricular Esquerda , Inquéritos e Questionários , Ablação por Cateter/métodos , Resultado do Tratamento
9.
Europace ; 25(4): 1277-1283, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36196613

RESUMO

Electrical storm (ES) is a predictor of mortality, and its treatment is challenging. Moreover, not all potential therapeutic strategies are available in all hospitals, and a standardized approach among European centres is lacking. The aim of this European Heart Rhythm Association (EHRA) survey was to assess the current management of patients with ES both in the acute and post-acute phases in 102 different European centres. A 20-item online questionnaire was sent out to the EHRA Research Network Centres. The median number of patients with ES treated annually per centre is 10 (IQR 5-15). The possibility of using autonomic modulation (e.g. percutaneous stellate ganglion block or thoracic epidural anaesthesia) for the acute ES treatment is available in only 29.3% of the centres. Moreover, although over 80% of centres perform ventricular tachycardia ablation, this procedure is available 24/7 in only 16.5% of the hospitals. There is a significant heterogeneity among centres regarding the availability of AADs and their use before deciding to proceed with a non-AAD strategy; specifically, 4.4% of centres use only one drug, 33.3% use two drugs, and 12.2% >two drugs, while about 50% of the centres decide based on individual patient's characteristics. Regarding the type of AADs used for the acute and post-acute management of ES patients, important variability is reported depending upon the underlying heart disease. Most patients considered for percutaneous ablation have structural heart disease. Only 46% of centres refer patients to psychological counselling after ES.


Assuntos
Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Humanos , Inquéritos e Questionários , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia , Cardiopatias/cirurgia , Europa (Continente)/epidemiologia
10.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37682245

RESUMO

AIMS: This study aims to survey current educational experience and the individual requirements for electrophysiologists in training. METHODS AND RESULTS: The European Heart Rhythm Association (EHRA) e-Communication Committee and the Scientific Initiatives Committee prepared a questionnaire and distributed it via newsletters, Twitter, LinkedIn, and Facebook. The survey consisted of 22 questions collected on an individual basis anonymously. Two hundred and forty-three responders from 35 countries (32% female, age 38 ± 6 years old) completed the survey. This EHRA electrophysiology (EP) fellowship survey showed that (i) hands-on participation and observation of EP procedures are very important; (ii) the main motivations to choose the EP fellowship institution are centre reputation and volume as well as the availability of a structured EP fellowship programme; (iii) 59% passed the EHRA exam and 46% took a national certification exam; (iv) respondents are overall satisfied with their own fellowships, but there are areas of less confidence such as conduction system pacing implantation and cardiac resynchronization therapy implantation; (v) 78% of respondents performed research during their fellowship, (vi) the optimal duration of an EP fellowship should be at least 2 years; and (viii) doing fellowships abroad is beneficial, but significant obstacles exist. CONCLUSION: The results of this EHRA survey may help to refine current EP fellowship programmes to improve the quality of EP training and early career building of young electrophysiologists.


Assuntos
Terapia de Ressincronização Cardíaca , Bolsas de Estudo , Humanos , Feminino , Adulto , Masculino , Doença do Sistema de Condução Cardíaco , Eletrofisiologia Cardíaca , Certificação
11.
Europace ; 25(3): 1144-1151, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36691111

RESUMO

AIMS: Information provided to patients prior to implantable cardioverter-defibrillator (ICD) insertion and their participation in the decision-making process are crucial for understanding ICD function and accepting this lifelong therapy. The aim of this study is to evaluate the extent to which different aspects related to ICD and quality of life were transmitted to patients prior to ICD implantation. METHODS AND RESULTS: Prospective, multicenter European study with an online questionnaire initiated by the European Heart Rhythm Association. The questionnaire was filled-in directly and personally by the ICD patients who were invited to participate. A total of 1809 patients (majority in their 40s-70s, with 624 women, 34.5%) from 10 European countries participated in the study. The median time from first ICD implantation was 5 years (interquartile range 2-10). Overall, 1155 patients (71.5%) felt optimally informed at the time of device implantation, however many respondents received no information about ICD-related complications (n = 801, 49.6%), driving restrictions (n = 718, 44.5%), and possibility of end-of-life ICD deactivation (n = 408, 25.4%). Of note, women were less frequently involved in the decision-making process than men (47.3% vs. 55.9%, P = 0.003) and reported to be less often optimally informed before ICD implantation than men (61.2% vs. 76.8%, P < 0.001). More women mentioned the desire to have learned more about ICD therapy and the benefit/risk balance (45.4% vs. 33.7% of men; P < 0.001). CONCLUSIONS: This patient-based evaluation provides alarming findings on the lack of information provided to patients prior ICD implantation, particularly for women.


Assuntos
Desfibriladores Implantáveis , Qualidade de Vida , Masculino , Humanos , Feminino , Estudos Prospectivos , Cardioversão Elétrica/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Europa (Continente) , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle
12.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38091971

RESUMO

Limited data are available regarding venous thromboembolism (VTE), specifically deep vein thrombosis (DVT) and pulmonary embolism (PE), following right-sided ablations and electrophysiological (EP) studies. Compared to left-sided procedures, no guidelines on antithrombotic management strategies for the prevention of DVT and PE are available. The main purpose of the present European Heart Rhythm Association (EHRA) survey is to report the current management of right-sided EP procedures, focusing on anticoagulation and prevention of VTE. An online survey was conducted using the EHRA infrastructure. A total of 244 participants answered a 19-items questionnaire on the periprocedural management of EP studies and right-sided catheter ablations. The right femoral vein is the most common access for EP studies and right-sided procedures. An ultrasound-guided approach is employed by more than 2/3 of respondents. Intravenous heparin is not commonly given by the majority of participants. About 1/3 of participants (34%) routinely prescribe VTE prophylaxis during (mostly aspirin and low molecular weight heparin) and 1/4 of respondents (25%) commonly prescribe VTE prophylaxis after discharge (mostly aspirin). Of note, respectively 13% and 9% of participants observed at least one DVT and one PE related to right-sided ablation or EP study within the last year in their center. The present survey shows that only a minority of operators routinely gives intraprocedural intravenous heparin and prescribes VTE prophylaxis after right-sided EP procedures. Compared to left-sided procedures like atrial fibrillation (AF) ablation, there are no consistent systematic antithrombotic management strategies.


Assuntos
Embolia Pulmonar , Tromboembolia Venosa , Humanos , Tromboembolia Venosa/epidemiologia , Tromboembolia Venosa/prevenção & controle , Anticoagulantes/uso terapêutico , Fibrinolíticos/uso terapêutico , Heparina , Embolia Pulmonar/prevenção & controle , Embolia Pulmonar/tratamento farmacológico , Aspirina , Inquéritos e Questionários
13.
Europace ; 25(2): 546-553, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36106562

RESUMO

AIMS: Electromechanical coupling in patients receiving cardiac resynchronization therapy (CRT) is not fully understood. Our aim was to determine the best combination of electrical and mechanical substrates associated with effective CRT. METHODS AND RESULTS: Sixty-two patients were prospectively enrolled from two centres. Patients underwent 12-lead electrocardiogram (ECG), cardiovascular magnetic resonance (CMR), echocardiography, and anatomo-electromechanical mapping (AEMM). Remodelling was measured as the end-systolic volume (ΔESV) decrease at 6 months. CRT was defined effective with ΔESV ≤ -15%. QRS duration (QRSd) was measured from ECG. Area strain was obtained from AEMM and used to derive systolic stretch index (SSI) and total left-ventricular mechanical time. Total left-ventricular activation time (TLVAT) and transeptal time (TST) were derived from AEMM and ECG. Scar was measured from CMR. Significant correlations were observed between ΔESV and TST [rho = 0.42; responder: 50 (20-58) vs. non-responder: 33 (8-44) ms], TLVAT [-0.68; 81 (73-97) vs. 112 (96-127) ms], scar [-0.27; 0.0 (0.0-1.2) vs. 8.7 (0.0-19.1)%], and SSI [0.41; 10.7 (7.1-16.8) vs. 4.2 (2.9-5.5)], but not QRSd [-0.13; 155 (140-176) vs. 167 (155-177) ms]. TLVAT and SSI were highly accurate in identifying CRT response [area under the curve (AUC) > 0.80], followed by scar (AUC > 0.70). Total left-ventricular activation time (odds ratio = 0.91), scar (0.94), and SSI (1.29) were independent factors associated with effective CRT. Subjects with SSI >7.9% and TLVAT <91 ms all responded to CRT with a median ΔESV ≈ -50%, while low SSI and prolonged TLVAT were more common in non-responders (ΔESV ≈ -5%). CONCLUSION: Electromechanical measurements are better associated with CRT response than conventional ECG variables. The absence of scar combined with high SSI and low TLVAT ensures effectiveness of CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Função Ventricular Esquerda/fisiologia , Cicatriz , Bloqueio de Ramo , Ecocardiografia , Eletrocardiografia/métodos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
14.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37140046

RESUMO

AIMS: The aim of this study was to identify potential regional disparities in characteristics of implantable cardioverter-defibrillator (ICD) recipients, patient perceptions and perspectives after implantation and level of information provided to patients. METHODS AND RESULTS: The prospective, multicentre, and multinational European Heart Rhythm Association patient Survey 'Living with an ICD' included patients already implanted with an ICD (median ICD dwell time - 5 years, interquartile range 2-10). An online questionnaire was filled-in by patients invited from 10 European countries. A total of 1809 patients (the majority in their 40s to 70s, 65.5% men) were enrolled, with 877 (48.5%) from Western Europe (group 1), followed by 563 from Central/Eastern Europe (group 2, 31.1%), and 369 from Southern Europe (group 3, 20.4%). A total of 52.9% of Central/Eastern Europe patients reported increased satisfaction after ICD placement compared with 46.6% from Western and 33.1% from Southern Europe (1 vs. 2 P = 0.047, 1 vs. 3 P < 0.001, 2 vs. 3 P < 0.001). About 79.2% of Central/Eastern and 76.0% of Southern Europe patients felt optimally informed at the time of device implantation compared with just 64.6% from Western Europe (1 vs. 2 P < 0.001, 1 vs. 3 P < 0.001, 2 vs. 3 P = ns). CONCLUSIONS: While physicians in Southern Europe should address the patients' concerns about the impact of the ICD on quality of life, physicians from Western Europe should focus on improving the quality of information provided to their prospective ICD patients. Novel strategies to address regional differences in patients' quality of life and provision of information are warranted.


Assuntos
Desfibriladores Implantáveis , Masculino , Humanos , Feminino , Qualidade de Vida , Estudos Prospectivos , Inquéritos e Questionários , Europa (Continente)/epidemiologia
15.
Europace ; 25(2): 643-650, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36352534

RESUMO

AIMS: To investigate the role of genetic testing in patients with idiopathic atrioventricular conduction disease requiring pacemaker (PM) implantation before the age of 50 years. METHODS AND RESULTS: All consecutive PM implantations in Southern Switzerland between 2010 and 2019 were evaluated. Inclusion criteria were: (i) age at the time of PM implantation: < 50 years; (ii) atrioventricular block (AVB) of unknown aetiology. Study population was investigated by ajmaline challenge and echocardiographic assessment over time. Genetic testing was performed using next-generation sequencing panel, containing 174 genes associated to inherited cardiac diseases, and Sanger sequencing confirmation of suspected variants with clinical implication. Of 2510 patients who underwent PM implantation, 15 (0.6%) were young adults (median age: 44 years, male predominance) presenting with advanced AVB of unknown origin. The average incidence of idiopathic AVB computed over the 2010-2019 time window was 0.7 per 100 000 persons per year (95% CI 0.4-1.2). Most of patients (67%) presented with specific genetic findings (pathogenic variant) or variants of uncertain significance (VUS). A pathogenic variant of PKP2 gene was found in one patient (6.7%) with no overt structural cardiac abnormalities. A VUS of TRPM4, MYBPC3, SCN5A, KCNE1, LMNA, GJA5 genes was found in other nine cases (60%). Of these, three unrelated patients (20%) presented the same heterozygous missense variant c.2531G > A p.(Gly844Asp) in TRPM4 gene. Diagnostic re-assessment over time led to a diagnosis of Brugada syndrome and long-QT syndrome in two patients (13%). No cardiac events occurred during a median follow-up of 72 months. CONCLUSION: Idiopathic AVB in adults younger than 50 years is a very rare condition with an incidence of 0.7 per 100 000 persons/year. Systematic investigations, including genetic testing and ajmaline challenge, can lead to the achievement of a specific diagnosis in up to 20% of patients. Heterozygous missense variant c.2531G > A p.(Gly844Asp) in TRPM4 gene was found in an additional 20% of unrelated patients, suggesting possible association of the variant with the disease.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Adulto Jovem , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Doença do Sistema de Condução Cardíaco/complicações , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/genética , Marca-Passo Artificial/efeitos adversos , Testes Genéticos , Ajmalina
16.
Cardiology ; 148(5): 441-447, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37487479

RESUMO

INTRODUCTION: Long-term complication rates in standard transvenous pacemakers are reported around 4-12% with a higher incidence in the elderly population. We report our experience in octogenarians undergoing leadless pacemaker implantation in two large-volume centers in Switzerland. METHODS: Consecutive patients undergoing leadless pacemaker implantation at two Swiss large volume centers (University Hospital Zurich, Zurich and Cardiocentro Ticino Institute, Lugano) between October 2015 and March 2020 were included in this retrospective analysis. Demographic information, clinical data, and procedural characteristics were recorded at the day of implantation and during follow-up. RESULTS: Two hundred and twenty patients (mean age 80.6 ± 7.7 years, male 66%) were included. The main indication for pacemaker implantation was slow ventricular rate atrial fibrillation (111 of 220 patients, 50.4%). Out of the 220 patients, 124 (56.3%) were ≥80 years. Overall successful implantation rate was 98.6%. In the octogenarian population, the median procedure time (45 ± 20.2 min vs. 40 ± 19.6 min, p = 0.03) and radiation duration (6.1 ± 8.2 min vs. 5.0 ± 7.2 min, p = 0.03) were longer compared to patients <80 years. Major complications (2.7%, n = 6) and device measurements during follow-up were similar between patients ≥80 and <80 years. CONCLUSION: Implantation of a leadless pacemaker device in octogenarians is safe and effective with a similarly low complication rate compared to non-octogenarians.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Humanos , Masculino , Idoso , Octogenários , Estudos Retrospectivos , Resultado do Tratamento , Fibrilação Atrial/terapia , Fibrilação Ventricular , Desenho de Equipamento
17.
Heart Vessels ; 38(5): 680-688, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36418560

RESUMO

No real-world data are available about the complications rate in drug-induced type 1 Brugada Syndrome (BrS) patients with an implantable cardioverter-defibrillator (ICD). Aim of our study is to compare the device-related complications, infections, and inappropriate therapies among drug-induced type 1 BrS patients with transvenous- ICD (TV-ICD) versus subcutaneous-ICD (S-ICD). Data for this study were sourced from the IBRYD (Italian BRugada sYnDrome) registry which includes 619 drug-induced type-1 BrS patients followed at 20 Italian tertiary referral hospitals. For the present analysis, we selected 258 consecutive BrS patients implanted with ICD. 198 patients (76.7%) received a TV-ICD, while 60 a S-ICD (23.4%). And were followed-up for a median time of 84.3 [46.5-147] months. ICD inappropriate therapies were experienced by 16 patients (6.2%). 14 patients (7.1%) in the TVICD group and 2 patients (3.3%) in S-ICD group (log-rank P = 0.64). ICD-related complications occurred in 31 patients (12%); 29 (14.6%) in TV-ICD group and 2 (3.3%) in S-ICD group (log-rank P = 0.41). ICD-related infections occurred in 10 patients (3.88%); 9 (4.5%) in TV-ICD group and 1 (1.8%) in S-ICD group (log-rank P = 0.80). After balancing for potential confounders using the propensity score matching technique, no differences were found in terms of clinical outcomes between the two groups. In a real-world setting of drug-induced type-1 BrS patients with ICD, no significant differences in inappropriate ICD therapies, device-related complications, and infections were shown among S-ICD vs TV-ICD. However, a reduction in lead-related complications was observed in the S-ICD group. In conclusion, our evidence suggests that S-ICD is at least non-inferior to TV-ICD in this population and may also reduce the risk of lead-related complications which can expose the patients to the necessity of lead extractions.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/etiologia , Pontuação de Propensão , Cardioversão Elétrica/efeitos adversos , Eletrocardiografia/métodos , Morte Súbita Cardíaca/epidemiologia , Resultado do Tratamento
18.
Eur Heart J ; 43(47): 4899-4908, 2022 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-36285887

RESUMO

AIMS: To determine the risk of subsequent adverse clinical outcomes in anticoagulated patients with atrial fibrillation (AF) who experienced a new bleeding event. METHODS AND RESULTS: Anticoagulated AF patients were followed in two prospective cohort studies. Information on incident bleeding was systematically collected during yearly follow-up visits and events were adjudicated as major bleeding or clinically relevant non-major bleeding (CRNMB) according to the International Society on Thrombosis and Haemostasis guidelines. The primary outcome was a composite of stroke, myocardial infarction (MI), or all-cause death. Time-updated multivariable Cox proportional-hazards models were used to compare outcomes in patients with and without incident bleeding. Median follow-up was 4.08 years [interquartile range (IQR): 2.93-5.98]. Of the 3277 patients included (mean age 72 years, 28.5% women), 646 (19.7%) developed a new bleeding, 297 (9.1%) a major bleeding and 418 (12.8%) a CRNMB. The incidence of the primary outcome was 7.08 and 4.04 per 100 patient-years in patients with and without any bleeding [adjusted hazard ratio (aHR): 1.36, 95% confidence interval (CI): 1.16-1.61; P < 0.001; median time between a new bleeding and a primary outcome 306 days (IQR: 23-832)]. Recurrent bleeding occurred in 126 patients [incidence, 8.65 per 100 patient-years (95% CI: 7.26-10.30)]. In patients with and without a major bleeding, the incidence of the primary outcome was 11.00 and 4.06 per 100 patient-years [aHR: 2.04, 95% CI: 1.69-2.46; P < 0.001; median time to a primary outcome 142 days (IQR: 9-518)], and 59 had recurrent bleeding [11.61 per 100 patient-years (95% CI: 8.99-14.98)]. The incidence of the primary outcome was 5.29 and 4.55 in patients with and without CRNMB [aHR: 0.94, 95% CI: 0.76-1.15; P = 0.53; median time to a composite outcome 505 days (IQR: 153-1079)], and 87 had recurrent bleeding [8.43 per 100 patient-years (95% CI: 6.83-10.40)]. Patients who had their oral anticoagulation (OAC) discontinued after their first bleeding episode had a higher incidence of the primary composite than those who continued OAC (63/89 vs. 159/557 patients; aHR: 4.46, 95% CI: 3.16-6.31; P < 0.001). CONCLUSION: In anticoagulated AF patients, major bleeding but not CRNMB was associated with a high risk of adverse outcomes, part of which may be explained by OAC discontinuation. Most events occurred late after the bleeding episode, emphasizing the importance of long-term follow-up in these patients.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Feminino , Idoso , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Anticoagulantes/efeitos adversos , Estudos Prospectivos , Fatores de Risco , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Hemorragia/complicações , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
19.
Europace ; 24(7): 1179-1185, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35348646

RESUMO

Conduction disorders such as left bundle branch block (LBBB) are common after transcatheter aortic valve implantation (TAVI). Consensus regarding a reasonable strategy to manage conduction disturbances after TAVI has been elusive. The European Heart Rhythm Association (EHRA) conducted a survey to capture contemporary clinical practice for conduction disorders after TAVI. A 25-item online questionnaire was developed and distributed among the EHRA electrophysiology (EP) research network centres. Of 117 respondents, 44% were affiliated with university hospitals. A standardized management protocol for advanced conduction disorders such as LBBB or atrioventricular block (AVB) after TAVI was available in 63% of participating centres. Telemetry after TAVI was chosen as the most frequent management strategy for patients with new-onset or pre-existing LBBB (79% and 70%, respectively). Duration of telemetry in patients with new-onset LBBB varied, with a 48-h period being the most frequently chosen, but almost half monitoring continued for at least 72 h. Similarly, in patients undergoing EP study due to new-onset LBBB, the HV interval cut-off point leading to pacemaker implantation was heterogeneous among European centres, although an HV >75 ms threshold was the most common. Conduction system pacing was chosen as a preferred approach by 3.7% of respondents for patients with LBBB and normal left ventricular ejection fraction (LVEF), and by 5.6% for patients with LBBB and reduced LVEF. This survey suggests some heterogenity in the management of conduction disorders after TAVI across European centres. The risk stratification strategies vary substantially. Conduction system pacing in patients with LBBB after TAVI is still underused.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/epidemiologia , Doença do Sistema de Condução Cardíaco/terapia , Humanos , Volume Sistólico , Inquéritos e Questionários , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
20.
Europace ; 24(3): 473-480, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34410364

RESUMO

It is unclear to what extent the COVID-19 pandemic has influenced the use of remote monitoring (RM) of cardiac implantable electronic devices (CIEDs). The present physician-based European Heart Rhythm Association (EHRA) survey aimed to assess the influence of the COVID-19 pandemic on RM of CIEDs among EHRA members and how it changed the current practice. The survey comprised 27 questions focusing on RM use before and during the pandemic. Questions focused on the impact of COVID-19 on the frequency of in-office visits, data filtering, reasons for initiating in-person visits, underutilization of RM during COVID-19, and RM reimbursement. A total of 160 participants from 28 countries completed the survey. Compared to the pre-pandemic period, there was a significant increase in the use of RM in patients with pacemakers (PMs) and implantable loop recorders (ILRs) during the COVID-19 pandemic (PM 24.2 vs. 39.9%, P = 0.002; ILRs 61.5 vs. 73.5%, P = 0.028), while there was a trend towards higher utilization of RM for cardiac resynchronization therapy-pacemaker (CRT-P) devices during the pandemic (44.5 vs. 55%, P = 0.063). The use of RM with implantable cardioverter-defibrillators (ICDs) and CRT-defibrillator (CRT-D) did not significantly change during the pandemic (ICD 65.2 vs. 69.6%, P = 0.408; CRT-D 65.2 vs. 68.8%, P = 0.513). The frequency of in-office visits was significantly lower during the pandemic (P < 0.001). Nearly two-thirds of participants (57 out of 87 respondents), established new RM connections for CIEDs implanted before the pandemic with 33.3% (n = 29) delivering RM transmitters to the patient's home address, and the remaining 32.1% (n = 28) activating RM connections during an in-office visit. The results of this survey suggest that the crisis caused by COVID-19 has led to a significant increase in the use of RM of CIEDs.


Assuntos
COVID-19 , Desfibriladores Implantáveis , Médicos , COVID-19/epidemiologia , Humanos , Pandemias , SARS-CoV-2 , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA