Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Hazard Mater ; 403: 123816, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33264913

RESUMO

The chronic kidney disease of unknown etiology (CKDu) prevalent in certain regions of Sri Lanka poses a serious threat to human health. Previous epidemiological studies focused on the search of causative agents for CKDu etiology from the viewpoint of groundwater composition, but how CKDu prevalence affected the groundwater microbial composition, especially the antibiotic resistome, has never been illuminated. This study investigated the response of microbial community and antibiotic resistome to CKDu prevalence in the groundwater through the high throughput sequencing and qPCR (HT-qPCR), respectively. Results showed that CKDu prevalence significantly influenced the distribution of antibiotic resistome and microbial community composition. The mexF dominated in all the groundwater samples and could be considered as an intrinsic ARG, and the ß-lactamase cphA was specially enriched and closely associated with the antibiotics used for CKDu patients. The Acinetobacter was a potential human pathogen common in the groundwater of CKDu affected regions, while CKDu prevalence specially enriched the Aeromonas. Statistical analysis indicated that CKDu prevalence impacted antibiotic resistome through the microbial community as a whole, and MGEs contributed to the occurrence of mexF, while the enrichment of cphA could be attributed to the increase of Aeromonas.


Assuntos
Água Subterrânea , Microbiota , Insuficiência Renal Crônica , Antibacterianos , Humanos , Prevalência , Sri Lanka/epidemiologia
2.
Membranes (Basel) ; 11(6)2021 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-34073869

RESUMO

Reverse osmosis (RO) drinking water stations have been introduced to provide safe drinking water for areas with prevailing chronic kidney disease with unknown (CKDu) etiology in the dry zone of Sri Lanka. In this investigation, RO drinking water stations established by community-based organizations (CBO) in the North Central Province (NCP) were examined. Water samples were collected from source, permeate, and concentrate in each station to determine water quality and performance. Furthermore, the operators of the systems were interviewed to evaluate operational and maintenance practices to identify major issues related to the RO systems. Results show that the majority (>93%) of RO systems had higher salt rejection rates (>92%), while water recovery varied from 19.4% to 64%. The removal efficiencies of hardness and alkalinity were averaged at 95.8% and 86.6%, respectively. Most dominant ions such as Ca2+, Mg2+, K+, Na+, Ba2+, Sr2+ Cl-, F-, and SO42- showed higher rejections at averaged values of 93.5%, 97.4%, 86.6%, 90.8%, 95.4%, 96.3%, 95.7%, 96.6%, and 99.0%, respectively. Low recovery rates, lower fluoride levels in product water, and membrane fouling were the main challenges. Lack of knowledge and training were the major issues that could shorten the lifespan of RO systems.

3.
Artigo em Inglês | MEDLINE | ID: mdl-31091829

RESUMO

This study investigated the water quality of the groundwater that was collected from the chronic kidney disease of unknown etiology (CKDu) prevailing areas in the dry zone of Sri Lanka to assess its suitability for drinking purposes, and for the first time a Water Quality Index (WQI) with emphasis on proposing appropriate drinking water treatment method was developed. A total of 88 groundwater samples were collected in dry (December 2016) and wet (May 2017) seasons; high concentrations of water hardness, fluoride, salinity, dissolved organic carbon (DOC), and the general alkaline nature of water were the main issues that were observed for disease incidence. The chemical weathering of the underlying bedrock, followed by ion exchange and precipitation processes, primarily controlled groundwater geochemistry. During the 1985-2017 period, the variations of the annual rainfall and temperature were minimal, which suggests no evidence for major climatic changes within the study areas. Almost all of the samples from the CKDu regions show a low alkali hazard and most of the samples show a medium to high salinity hazard. The DOC of the studied samples was mainly composed of the organic fractions in the following order, as fulvic acids > humic acids > aromatic protein II > soluble microbial by-products, and the molecular weights (MW) of these fractions ranged from 100-3000 Da. Based on the water quality index (WQI) calculations, it was found that only 3.8% in the wet season and 2.6% in the dry season of total water samples were categorized as the "excellent" type, and all other water sources require a further treatment before consumption. As there is an urgent need for establishing proper long-term drinking water treatment technology for the CKDu affected area, these findings can be used as benchmark of raw water quality in the design processes of treatment plants.


Assuntos
Água Potável/análise , Fluoretos/análise , Água Subterrânea/análise , Insuficiência Renal Crônica/epidemiologia , Poluentes Químicos da Água/análise , Estações do Ano , Sri Lanka/epidemiologia , Purificação da Água , Qualidade da Água
4.
Rev Sci Instrum ; 80(2): 023907, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19256662

RESUMO

A temperature of 3500 degrees C was generated using a diamond resistance heater in a large-volume Kawai-type high-pressure apparatus. Re and LaCrO(3) have conventionally been used for heaters in high-pressure studies but they cannot generate temperatures higher than 2900 degrees C and make in situ x-ray observations difficult due to their high x-ray absorption. Using a boron-doped diamond heater overcomes these problems and achieves stable temperature generation for pressure over 10 GPa. The heater starting material is a cold-compressed mixture of graphite with boron used to avoid the manufacturing difficulties due to the extreme hardness of diamond. The diamond heater was synthesized in situ from the boron-graphite mixture at temperature of 1600+/-100 degrees C and pressure of 20 GPa. By using the proposed technique, we have employed the diamond heater for high-temperature generation in a large-volume high-pressure apparatus. Achievement of temperatures above 3000 degrees C allows us to measure the melting points of the important constituents in earth's mantle (MgSiO(3), SiO(2), and Al(2)O(3)) and core (Fe and Ni) at extremely high pressures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA