Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
2.
Cancers (Basel) ; 13(7)2021 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-33916787

RESUMO

B-cell regeneration during therapy has been considered as a strong prognostic factor in multiple myeloma (MM). However, the effects of therapy and hemodilution in bone marrow (BM) B-cell recovery have not been systematically evaluated during follow-up. MM (n = 177) and adult (≥50y) healthy donor (HD; n = 14) BM samples were studied by next-generation flow (NGF) to simultaneously assess measurable residual disease (MRD) and residual normal B-cell populations. BM hemodilution was detected in 41 out of 177 (23%) patient samples, leading to lower total B-cell, B-cell precursor (BCP) and normal plasma cell (nPC) counts. Among MM BM, decreased percentages (vs. HD) of BCP, transitional/naïve B-cell (TBC/NBC) and nPC populations were observed at diagnosis. BM BCP increased after induction therapy, whereas TBC/NBC counts remained abnormally low. At day+100 postautologous stem cell transplantation, a greater increase in BCP with recovered TBC/NBC cell numbers but persistently low memory B-cell and nPC counts were found. At the end of therapy, complete response (CR) BM samples showed higher CD19- nPC counts vs. non-CR specimens. MRD positivity was associated with higher BCP and nPC percentages. Hemodilution showed a negative impact on BM B-cell distribution. Different BM B-cell regeneration profiles are present in MM at diagnosis and after therapy with no significant association with patient outcome.

3.
J Immunol Methods ; 475: 112618, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31181212

RESUMO

Fluorochrome selection is a key step in designing multi-color antibody panels. The list of available fluorochromes is continuously growing, fitting current needs in clinical flow cytometry to simultaneously use more markers to better define multiple leukocyte subpopulations in a single tube. Several criteria guide fluorochrome selection: i) the fluorescence profiles (excitation and emission), ii) relative brightness, iii) fluorescence overlap, iv) fluorochrome stability, and v) reproducible conjugation to antibodies. Here we used 75 samples (45 bone marrow and 30 blood) to illustrate EuroFlow strategies for evaluation of compatible fluorochromes, and how the results obtained guide fluorochrome selection as a critical step in the antibody-panel building process. Our results allowed identification of optimal fluorescence profiles (e.g. higher fluorescence intensity and/or resolution with limited fluorescence overlap into neighbor channels) for brilliant violet (BV)421 and BV510 in the violet laser and allophycocyanin (APC) hilite 7 (H7) or APC C750 in the red laser vs. other candidate fluorochromes generally applied for the same detectors and here evaluated. Moreover, evaluation of the same characteristics for another group of fluorochromes (e.g. BV605, BV650, PE CF594, AF700 or APC AF700) guided selection of the most appropriate fluorochrome conjugates to be combined in a multi-color antibody panel. Albeit this is a demanding approach, it could be successfully applied for selection of fluorochrome combinations for the EuroFlow antibody panels for diagnosis, classification and monitoring of hematological malignancies and primary immunodeficiencies. Consequently, sets of 8-, 10- and 12-color fluorochrome combinations are proposed as frame of reference for initial antibody panel design.


Assuntos
Citometria de Fluxo/métodos , Corantes Fluorescentes , Imunofenotipagem/métodos , Humanos
4.
J Immunol Methods ; 475: 112287, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-28341440

RESUMO

Within EuroFlow, we recently developed screening tubes for hematological malignancies and immune deficiencies. Pipetting of antibodies for such 8-color 12-marker tubes however is time-consuming and prone to operational mistakes. We therefore evaluated dried formats of the lymphocytosis screening tube (LST) and of the primary immune deficiency orientation tube (PIDOT). Both tubes were evaluated on normal and/or on patient samples, comparing the mean fluorescence intensity of specific lymphocyte populations. Our data show that the dried tubes and liquid counterparts give highly comparable staining results, particularly when analyzed in multidimensional plots. In addition, the use of dried tubes may result in a reduced staining variability between different samples and thereby contributes to the generation of more robust data. Therefore, by using ready-to-use reagents in a dried single test tube format, the laboratory efficiency and quality will be improved.


Assuntos
Neoplasias Hematológicas/diagnóstico , Imunofenotipagem/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA