Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Radiographics ; 33(3): 633-52, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23674767

RESUMO

Transplantation is the surgical treatment of choice for end-stage organ failure. Transplantation procedures performed in the abdomen include liver, renal, pancreas, islet, intestinal, and multivisceral transplantations. Imaging plays a pivotal role in the posttransplantation setting for monitoring the transplant allograft and screening for complications. Knowledge of the surgical techniques employed in abdominal transplantation is essential because it facilitates radiologic understanding and interpretation of the posttransplantation anatomy. This article includes a basic description of the standard surgical techniques performed in the abdomen, with emphasis on the relevant vascular anastomotic reconstructions used. Posttransplantation complications can be broadly classified as vascular or nonvascular in origin. Many of these complications can be accurately depicted and characterized at imaging and dealt with definitively by using interventional radiology techniques, which can be graft- and life-saving and can obviate further complex surgical intervention. The article discusses imaging appearances of vascular complications and their consequences after transplantation in the abdomen. These vascular complications include arterial thrombosis, arterial stenosis, venous thrombosis and stenosis, arteriovenous fistula formation, and pseudoaneurysm formation. The relevant predisposing factors, clinical features, imaging appearances, and potential treatment options for vascular complications of various types of transplantation are presented in a logical and integrated fashion. Knowledge and imaging recognition of the posttransplantation vascular complications discussed in this article will aid radiologists in accurate imaging characterization and thereby facilitate appropriate clinical management and therapy.


Assuntos
Rejeição de Enxerto/diagnóstico , Transplante de Órgãos/efeitos adversos , Imagem de Perfusão/métodos , Doenças Vasculares Periféricas/diagnóstico , Doenças Vasculares Periféricas/etiologia , Lesões do Sistema Vascular/diagnóstico , Lesões do Sistema Vascular/etiologia , Rejeição de Enxerto/etiologia , Humanos , Aumento da Imagem/métodos , Resultado do Tratamento
2.
J Am Heart Assoc ; 12(21): e030229, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37929714

RESUMO

Background The prognostic utility of cardiovascular magnetic resonance imaging, including strain analysis and tissue characterization, has not been comprehensively investigated in adult patients with muscular dystrophy. Methods and Results We prospectively enrolled 148 patients with dystrophinopathies (including heterozygotes), limb-girdle muscular dystrophy, and type 1 myotonic dystrophy (median age, 36.0 [interquartile range, 23.0-50.0] years; 51 [34.5%] women) over 7.7 years in addition to an age- and sex-matched healthy control cohort (n=50). Cardiovascular magnetic resonance markers, including 3-dimensional strain and fibrosis, were assessed for their respective association with major adverse cardiac events. Our results showed that markers of contractile performance were reduced across all muscular dystrophy groups. In particular, the dystrophinopathies cohort experienced reduced left ventricular (LV) ejection fraction and high burden of replacement fibrosis. Patients with type 1 myotonic dystrophy showed a 26.8% relative reduction in LV mass with corresponding reduction in chamber volumes. Eighty-two major adverse cardiac events occurred over a median follow-up of 5.2 years. Although LV ejection fraction was significantly associated with major adverse cardiac events (adjusted hazard ratio [aHR], 3.0 [95% CI, 1.4-6.4]) after adjusting for covariates, peak 3-dimensional strain amplitude demonstrated greater predictive value (minimum principal amplitude: aHR, 5.5 [95% CI, 2.5-11.9]; maximum principal amplitude: aHR, 3.3 [95% CI, 1.6-6.8]; circumferential amplitude: aHR, 3.4 [95% CI, 1.6-7.2]; longitudinal amplitude: aHR, 3.4 [95% CI, 1.7-6.9]; and radial strain amplitude: aHR, 3.0 [95% CI, 1.4-6.1]). Minimum principal strain yielded incremental prognostic value beyond LV ejection fraction for association with major adverse cardiac events (change in χ2=13.8; P<0.001). Conclusions Cardiac dysfunction is observed across all muscular dystrophy subtypes; however, the subtypes demonstrate distinct phenotypic profiles. Myocardial deformation analysis highlights unique markers of principal strain that improve risk assessment over other strain markers, LV ejection fraction, and late gadolinium enhancement in this vulnerable patient population.


Assuntos
Cardiopatias , Distrofia Miotônica , Adulto , Humanos , Feminino , Masculino , Prognóstico , Meios de Contraste , Imagem Cinética por Ressonância Magnética , Gadolínio , Imageamento por Ressonância Magnética , Função Ventricular Esquerda , Volume Sistólico , Fibrose , Espectroscopia de Ressonância Magnética
3.
Radiol Cardiothorac Imaging ; 2(4): e190140, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33778595

RESUMO

PURPOSE: To compare the contributions of cardiac MRI and PET in the diagnosis and management of cardiac sarcoidosis (CS), with particular reference to quantitative measures. MATERIALS AND METHODS: This is a retrospective, observational study of 31 patients (mean age, 45.7 years) with proven extracardiac sarcoidosis and possible CS who were investigated with fluorine 18 fluorodeoxyglucose (FDG) PET/CT and cardiac MRI. Patients were treated at physicians' discretion with repeat combined imaging after an interval of 102-770 days (median, 228 days). RESULTS: Significant myocardial FDG uptake was shown on visit 1 (myocardial maximum standardized uptake value [SUVmax] > 3.6) in 17 of 22 patients who were subsequently treated. Myocardial SUVmax decreased at follow-up (6.5 to 4.0; P < .01) and was matched by significant decreases in FDG-avid lung and mediastinal node disease. A volumetric measure of myocardium above a threshold SUV (cardiac metabolic volume) decreased from a mean of 42.5 to a mean of 4.1 (P < .001). This was associated with significant improvement in the left ventricular ejection fraction (LVEF) (45.8 increasing to 50.9; P < .031). There was no change in volume of late gadolinium enhancement at treatment. Patients who were untreated showed no change in any FDG PET or cardiac MRI parameter. CONCLUSION: Myocardial FDG uptake in patients suspected of having CS is presumed to represent active inflammation. When treated with corticosteroids, this resolved or regressed at follow-up, with an improvement in LVEF and FDG-avid thoracic disease. Patients who were untreated showed no change in any parameter. Quantification of FDG-avid myocardium using cardiac metabolic volume is proposed as a useful objective measure for assessing response to therapy.© RSNA, 2020See also commentary by Gutberlet in this issue.

4.
Stroke ; 37(1): e6-8, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16306455

RESUMO

BACKGROUND AND PURPOSE: Calcific brain embolization is a rare event that is usually secondary to cardiac valve calcification. We present a case of stroke caused by embolization of calcific material from the brachiocephalic trunk, probably induced by radiotherapy. SUMMARY OF CASE: A 56-year-old right-handed female developed left-sided hemiparesis, hemihypesthesia, and sensory inattention. She had a history of right breast carcinoma that was excised 8 years previously followed by radiotherapy. She had no other history of note. Computed tomography of the head and magnetic resonance imaging confirmed a calcific embolus in right middle cerebral artery and an acute infarction in the corresponding territory. Plain chest radiography, carotid ultrasonography, transthoracic and transoesophageal echocardiography failed to demonstrate the source of calcific embolism. Computed tomography of the thorax revealed heavy calcification of the brachiocephalic trunk and the origin of the right common carotid artery. CONCLUSIONS: Undertaking a vigilant systematic search for the source in cases of calcific embolization is necessary. The aorta and its main branches are possible, yet unusual, sources of calcific emboli that merit investigation.


Assuntos
Tronco Braquiocefálico/patologia , Embolia/patologia , Valvas Cardíacas/patologia , Acidente Vascular Cerebral/patologia , Aterosclerose/patologia , Pressão Sanguínea , Artérias Carótidas/patologia , Ecocardiografia , Esôfago/patologia , Feminino , Humanos , Embolia Intracraniana/diagnóstico , Embolia Intracraniana/patologia , Embolia e Trombose Intracraniana/patologia , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Artéria Cerebral Média/patologia , Acidente Vascular Cerebral/etiologia , Tromboembolia/patologia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Ultrassonografia
5.
Radiology ; 238(3): 827-40, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16424245

RESUMO

PURPOSE: To prospectively evaluate accuracy of gadolinium-enhanced three-dimensional (3D) magnetic resonance (MR) angiography with gadodiamide and gadopentetate dimeglumine (0.1 mmol/kg), with intraarterial DSA as reference standard, for imaging abdominal and iliac arterial stenoses. MATERIALS AND METHODS: The study was approved by all institutional review boards; informed consent was obtained from each subject before procedures. Two hundred forty-seven subjects were included; 240 received either contrast agent and were available for safety analysis; 222 were available for accuracy analysis. Enhanced 3D MR angiography and DSA were performed; image data were evaluated in a double-blinded randomized study. Stenoses were classified as not relevant (<50% stenosis) or relevant (> or =50%). For detection of main stenosis, accuracy with enhanced 3D MR angiography compared with that with DSA was determined. RESULTS: The difference in accuracy for imaging with gadodiamide and gadopentetate was 3.6%. Noninferiority was inferred because the lower bound of the exact two-sided 95% confidence interval was -10.1 and was above the noninferiority margin (-15%). Accuracy for detection of the main stenosis was low, 56.4% for gadodiamide and 52.8% for gadopentetate group. Subgroup analysis with exclusion of inferior mesenteric artery and internal iliac arteries and the most false-positive stenosis classifications yielded better results: 76.6% and 71.6%, respectively. Sensitivity, specificity, and negative and positive predictive values did not differ substantially between study groups. In the main analysis, values were 44%, 96%, 35%, and 97% for gadodiamide and 44%, 83%, 30%, and 90% for gadopentetate, respectively. In the subgroup analysis, values were 66%, 95%, 61%, and 96% for gadodiamide and 63%, 86%, 58%, and 88% for gadopentetate, respectively. CONCLUSION: Noninferiority of gadodiamide versus gadopentetate was verified based on the primary end point, which was accuracy for detection of the main stenosis with enhanced 3D MR angiography compared with DSA.


Assuntos
Abdome/irrigação sanguínea , Arteriopatias Oclusivas/diagnóstico , Meios de Contraste , Gadolínio DTPA , Artéria Ilíaca , Imageamento Tridimensional , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Arteriopatias Oclusivas/diagnóstico por imagem , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
6.
Eur Radiol ; 14(7): 1154-61, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15007611

RESUMO

High-resolution axial black-blood MR imaging (BB MRI) has been shown to be able to characterise carotid plaque morphology. The aim of this study was to explore the accuracy of this technique in quantifying the severity of carotid stenosis. A prospective study of 54 patients with symptomatic carotid disease was conducted, comparing BB MRI to the gold standard, conventional digital subtraction X-ray angiography (DSA). The BB MRI sequence was a fast-spin echo acquisition (TE = 42 ms, ETL = 24, field of view = 100 x 100 mm, slice thickness = 3.0 mm) at 1.5 T using a custom-built phased-array coil. Linear measurements of luminal and outer carotid wall diameter were made directly from the axial BB MRI slices by three independent blinded readers and stenosis was calculated according to European Carotid Surgery Trial (ECST) criteria. There was good agreement between BB MRI and DSA (intraclass correlation = 0.83). Inter-observer agreement was good (average kappa = 0.77). BB MRI was accurate for detection of severe stenosis (> or = 80%) with sensitivity and specificity of 87 and 81%, respectively. Eight cases of "DSA-defined" moderate stenosis were overestimated as severe by BB MRI and this may be related to non-circular lumens. Axial imaging with BB MRI could potentially be used to provide useful information about severity of carotid stenosis.


Assuntos
Artéria Carótida Interna/patologia , Estenose das Carótidas/diagnóstico , Imageamento por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA