RESUMO
We report a case of Klebsiella pneumoniae bacteraemia in an 80-year-old man in France with no history of travel to Asia, complicated by endogenous endophthalmitis, multiple cerebral microbleeds and hepatic microabscesses, associated with a Bentall endocarditis. Hypervirulence pathotype was suggested based on clinical picture, bacterial isolate genomic sequence and hypermucoidy. Interestingly, the isolate had the non-K1/K2-capsular serotype locus KL113-like, carried a KpVP-1-like virulence plasmid, and belonged to the emerging sublineage SL660 (comprising the sequence type ST660).
Assuntos
Bacteriemia , Infecções por Klebsiella , Klebsiella pneumoniae , Humanos , Klebsiella pneumoniae/genética , Klebsiella pneumoniae/isolamento & purificação , Klebsiella pneumoniae/classificação , Klebsiella pneumoniae/patogenicidade , Masculino , Idoso de 80 Anos ou mais , Infecções por Klebsiella/microbiologia , Infecções por Klebsiella/diagnóstico , Bacteriemia/microbiologia , Endoftalmite/microbiologia , Endoftalmite/diagnóstico , França , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/diagnóstico , Hemorragia Cerebral/microbiologiaRESUMO
PURPOSE: To assess the refractive predictability of the Carlevale sutureless scleral fixation intraocular lens (IOL) (Sole-ko IOL Division) power calculation. METHODS: This retrospective, non-comparative, interventional case series included patients without a capsular support having undergone sutureless scleral fixation IOL implantation in two French hospitals between October 2019 and April 2022. IOL calculation was performed with the Barrett Universal II, Hoffer Q, Holladay 1, and SRK/T formulas with constant optimization to achieve a mean arithmetic prediction error equal to zero. The main outcomes were prediction error (PE) and its standard deviation (SD-PE), the median absolute error (MedAE), the mean absolute error (MAE), and the percentage of eyes with PE within ±0.50, ±1.00 and ±2.00 diopters (D) 6 months after surgery. RESULTS: Thirty eyes of 30 patients were included in the study. The mean age was 66.6 years, the mean axial length was 24.31 mm, and the mean keratometry was 43.07 D. SDPE ranged from 0.73 to 0.87 D depending on the formula. MedAE ranged from 0.38 to 0.61 D, and MAE from 0.52 to 0.68 D. Between 46.7% and 56.7% of eyes were within ±0.50 D, 76.7% and 90.0% were within ±1.00 D, and 96.7% were within ±2.00 D of target equivalent. No statistically significant difference was observed between the four formulas for any outcomes. CONCLUSIONS: This study confirmed that the design of the Carlevale sutureless scleral fixation IOL provides satisfactory refractive results. [J Refract Surg. 2024;40(8):e527-e532.].