Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Magn Reson Med ; 89(1): 192-204, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36093906

RESUMO

PURPOSE: Many MRI sequences are sensitive to motion and its associated artifacts. The linearized geometric solution (LGS), a balanced steady-state free precession (bSSFP) off-resonance signal demodulation technique, is evaluated with respect to motion artifact resilience. THEORY AND METHODS: The mechanism and extent of LGS motion artifact resilience is examined in simulated, flow phantom, and in vivo clinical imaging. Motion artifact correction capabilities are decoupled from susceptibility artifact correction when feasible to permit controlled analysis of motion artifact correction when comparing the LGS with standard and phase-cycle-averaged (complex sum) bSSFP imaging. RESULTS: Simulations reveal that the LGS demonstrates motion artifact reduction capabilities similar to standard clinical bSSFP imaging techniques, with slightly greater resilience in high SNR regions and for shorter-duration motion. Flow phantom experiments assert that the LGS reduces shorter-duration motion artifact error by ∼24%-65% relative to the complex sum, whereas reconstructions exhibit similar error reduction for constant motion. In vivo analysis demonstrates that in the internal auditory canal/orbits, the LGS was deemed to have less artifact in 24%/49% and similar artifact in 76%/51% of radiological assessments relative to the complex sum, and the LGS had less artifact in 97%/81% and similar artifact in 3%/16% of assessments relative to standard bSSFP. Only 2 of 63 assessments deemed the LGS inferior to either complex sum or standard bSSFP in terms of artifact reduction. CONCLUSION: The LGS provides sufficient bSSFP motion artifact resilience to permit robust elimination of susceptibility artifacts, inspiring its use in a wide variety of applications.


Assuntos
Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Algoritmos , Artefatos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
2.
J Comput Assist Tomogr ; 46(1): 97-102, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35099141

RESUMO

OBJECTIVE: This study aimed to assess the changes and values on follow-up computed tomography (F/U-CT) for isolated falcine (F-SDH) and tentorial (T-SDH) subdural hematomas (SDHs). METHOD: Fifty-four cases of isolated F-SDH and/or T-SDH were retrospectively reviewed. Subdural hematoma morphology, mass effect on the adjacent parenchyma, and interval change at F/U-CT were evaluated. Subdural hematoma size was measured parallel and perpendicular to the falx/tentorium (long or short axis, respectively). RESULTS: Short-axis increase on F/U-CT was seen only in 5 F-SDHs (16%) and 7 T-SDHs (19%), with a maximum of a 2-mm increase. Long-axis growth was more prominent and frequent, seen in 18 F-SDH patients (56.2%) and 19 T-SDH patients (51.4%), with maximum change of up to 43 mm. Falcine SDH and T-SDH were ipsilateral and contiguous in 77.8% of patients. Minimal mass effect was seen in 13 patients (24.1%), which was resolved or stable on F/U-CT. Anticoagulation did not affect SDH size. No patients required neurosurgery or died. CONCLUSIONS: Based on our limited data, the current standard of F/U-CT may be unnecessary in patients with isolated F-SDH and/or T-SDH, which expand minimally along the short axis without a significant mass effect. Characteristic anatomic structure of the tentorium and falx, and their connectivity may direct SDH expansion and limit mass effect as well as injury to the adjacent parenchyma.


Assuntos
Dura-Máter/diagnóstico por imagem , Hematoma Subdural/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Estudos Retrospectivos
3.
Emerg Radiol ; 28(4): 797-808, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33580850

RESUMO

The purpose of this review is to understand the role of imaging in the diagnosis and management of non-traumatic subarachnoid hemorrhage (SAH). SAH is a life-threatening emergency and a relatively common entity, the most common etiology being ruptured aneurysms. Multiple conundrums exist in literature at various steps of its imaging workup: diagnosis, management, and follow-up. We target our review to highlight the most effective practice and suggest efficient workup plans based on literature search, and describe in detail the clinical diagnostic and prognostic scales, role of CT scan, lumbar puncture, and MR, including angiography in the diagnosis and workup of SAH and its complications, and try to simplify the conundrums. Practical knowledge of imaging workup of SAH can help guide correct management of these patients, so as to reduce morbidity and mortality without resource overutilization.


Assuntos
Aneurisma Roto , Hemorragia Subaracnóidea , Angiografia Cerebral , Humanos , Punção Espinal , Hemorragia Subaracnóidea/diagnóstico por imagem , Tomografia Computadorizada por Raios X
4.
J Digit Imaging ; 33(5): 1280-1291, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32556912

RESUMO

Manufacturing technologies continue to be developed and utilized in medical prototyping, simulations, and imaging phantom production. For radiologic image-guided simulation and instruction, models should ideally have similar imaging characteristics and physical properties to the tissues they replicate. Due to the proliferation of different printing technologies and materials, there is a diverse and broad range of approaches and materials to consider before embarking on a project. Although many printed materials' biomechanical parameters have been reported, no manufacturer includes medical imaging properties that are essential for realistic phantom production. We hypothesize that there are now ample materials available to create high-fidelity imaging anthropomorphic phantoms using 3D printing and casting of common commercially available materials. A material database of radiological, physical, manufacturing, and economic properties for 29 castable and 68 printable materials was generated from samples fabricated by the authors or obtained from the manufacturer and scanned with CT at multiple tube voltages. This is the largest study assessing multiple different parameters associated with 3D printing to date. These data are being made freely available on GitHub, thus affording medical simulation experts access to a database of relevant imaging characteristics of common printable and castable materials. Full data available at: https://github.com/nmcross/Material-Imaging-Characteristics .


Assuntos
Impressão Tridimensional , Simulação por Computador , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
6.
J Am Coll Radiol ; 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38527641

RESUMO

PURPOSE: Osteoporotic vertebral compression fractures (OVCFs) are a highly prevalent source of morbidity and mortality, and preventive treatment has been demonstrated to be both effective and cost effective. To take advantage of the information available on existing chest and abdominal radiographs, the authors' study group has developed software to access these radiographs for OVCFs with high sensitivity and specificity using an established artificial intelligence deep learning algorithm. The aim of this analysis was to assess the potential cost-effectiveness of implementing this software. METHODS: A deterministic expected-value cost-utility model was created, combining a tree model and a Markov model, to compare the strategies of opportunistic screening for OVCFs against usual care. Total costs and total quality-adjusted life-years were calculated for each strategy. Screening and treatment costs were considered from a limited societal perspective, at 2022 prices. RESULTS: In the base case, assuming a cost of software implantation of $10 per patient screened, the screening strategy dominated the nonscreening strategy: it resulted in lower cost and increased quality-adjusted life-years. The lower cost was due primarily to the decreased costs associated with fracture treatment and decreased probability of requiring long-term care in patients who received preventive treatment. The screening strategy was dominant up to a cost of $46 per patient screened. CONCLUSIONS: Artificial intelligence-based opportunistic screening for OVCFs on existing radiographs can be cost effective from a societal perspective.

7.
J Am Coll Radiol ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38789066

RESUMO

With promising Artificial Intelligence (AI) algorithms receiving FDA (Food and Drug Administration) clearance, the potential impact of these models on clinical outcomes must be evaluated locally before their integration into routine workflows. Robust validation infrastructures are pivotal to inspecting the accuracy and generalizability of these deep learning algorithms to ensure both patient safety and health equity. Protected Health Information (PHI) concerns, intellectual property rights, and diverse requirements of models impede the development of rigorous external validation infrastructures. Our work proposes various suggestions for addressing the challenges associated with the development of efficient, customizable, and cost-effective infrastructures for the external validation of AI models at large medical centers and institutions. We present comprehensive steps to establish an AI inferencing infrastructure outside clinical systems to examine the local performance of AI algorithms before health practice- or system-wide implementation and promote an evidence-based approach for adopting AI models that can enhance radiology workflows and improve patient outcomes.

8.
J Digit Imaging ; 26(4): 643-50, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23288437

RESUMO

Radiologists routinely make decisions with only limited information when assigning protocol instructions for the performance of advanced medical imaging examinations. Opportunity exists to simultaneously improve the safety, quality and efficiency of this workflow through the application of an electronic solution leveraging health system resources to provide concise, tailored information and decision support in real-time. Such a system has been developed using an open source, open standards design for use within the Veterans Health Administration. The Radiology Protocol Tool Recorder (RAPTOR) project identified key process attributes as well as inherent weaknesses of paper processes and electronic emulators of paper processes to guide the development of its optimized electronic solution. The design provides a kernel that can be expanded to create an integrated radiology environment. RAPTOR has implications relevant to the greater health care community, and serves as a case model for modernization of legacy government health information systems.


Assuntos
Diagnóstico por Imagem/normas , Eficiência Organizacional/normas , Segurança do Paciente/normas , Qualidade da Assistência à Saúde/normas , Sistemas de Informação em Radiologia/normas , United States Department of Veterans Affairs , Fluxo de Trabalho , Humanos , Sistemas Computadorizados de Registros Médicos/normas , Guias de Prática Clínica como Assunto , Estados Unidos
9.
Acad Radiol ; 30(12): 2973-2987, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37438161

RESUMO

RATIONALE AND OBJECTIVES: Spinal osteoporotic compression fractures (OCFs) can be an early biomarker for osteoporosis but are often subtle, incidental, and underreported. To ensure early diagnosis and treatment of osteoporosis, we aimed to build a deep learning vertebral body classifier for OCFs as a critical component of our future automated opportunistic screening tool. MATERIALS AND METHODS: We retrospectively assembled a local dataset, including 1790 subjects and 15,050 vertebral bodies (thoracic and lumbar). Each vertebral body was annotated using an adaption of the modified-2 algorithm-based qualitative criteria. The Osteoporotic Fractures in Men (MrOS) Study dataset provided thoracic and lumbar spine radiographs of 5994 men from six clinical centers. Using both datasets, five deep learning algorithms were trained to classify each individual vertebral body of the spine radiographs. Classification performance was compared for these models using multiple metrics, including the area under the receiver operating characteristic curve (AUC-ROC), sensitivity, specificity, and positive predictive value (PPV). RESULTS: Our best model, built with ensemble averaging, achieved an AUC-ROC of 0.948 and 0.936 on the local dataset's test set and the MrOS dataset's test set, respectively. After setting the cutoff threshold to prioritize PPV, this model achieved a sensitivity of 54.5% and 47.8%, a specificity of 99.7% and 99.6%, and a PPV of 89.8% and 94.8%. CONCLUSION: Our model achieved an AUC-ROC>0.90 on both datasets. This testing shows some generalizability to real-world clinical datasets and a suitable performance for a future opportunistic osteoporosis screening tool.


Assuntos
Aprendizado Profundo , Fraturas por Compressão , Osteoporose , Fraturas da Coluna Vertebral , Masculino , Humanos , Fraturas por Compressão/diagnóstico por imagem , Estudos Retrospectivos , Densidade Óssea , Fraturas da Coluna Vertebral/diagnóstico por imagem , Osteoporose/complicações , Osteoporose/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Algoritmos
10.
Acad Radiol ; 29(12): 1819-1832, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35351363

RESUMO

RATIONALE AND OBJECTIVES: Osteoporosis affects 9% of individuals over 50 in the United States and 200 million women globally. Spinal osteoporotic compression fractures (OCFs), an osteoporosis biomarker, are often incidental and under-reported. Accurate automated opportunistic OCF screening can increase the diagnosis rate and ensure adequate treatment. We aimed to develop a deep learning classifier for OCFs, a critical component of our future automated opportunistic screening tool. MATERIALS AND METHODS: The dataset from the Osteoporotic Fractures in Men Study comprised 4461 subjects and 15,524 spine radiographs. This dataset was split by subject: 76.5% training, 8.5% validation, and 15% testing. From the radiographs, 100,409 vertebral bodies were extracted, each assigned one of two labels adapted from the Genant semiquantitative system: moderate to severe fracture vs. normal/trace/mild fracture. GoogLeNet, a deep learning model, was trained to classify the vertebral bodies. The classification threshold on the predicted probability of OCF outputted by GoogLeNet was set to prioritize the positive predictive value (PPV) while balancing it with the sensitivity. Vertebral bodies with the top 0.75% predicted probabilities were classified as moderate to severe fracture. RESULTS: Our model yielded a sensitivity of 59.8%, a PPV of 91.2%, and an F1 score of 0.72. The areas under the receiver operating characteristic curve (AUC-ROC) and the precision-recall curve were 0.99 and 0.82, respectively. CONCLUSION: Our model classified vertebral bodies with an AUC-ROC of 0.99, providing a critical component for our future automated opportunistic screening tool. This could lead to earlier detection and treatment of OCFs.


Assuntos
Aprendizado Profundo , Fraturas por Compressão , Osteoporose , Fraturas da Coluna Vertebral , Masculino , Feminino , Humanos , Fraturas por Compressão/diagnóstico por imagem , Fraturas da Coluna Vertebral/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Radiografia
11.
Br J Radiol ; 94(1127): 20210149, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33914618

RESUMO

OBJECTIVE: We reviewed the literature to describe outcomes associated with abnormal neuroimaging findings among adult COVID-19 patients. METHODS: We performed a systematic literature review using PubMed and Embase databases. We included all studies reporting abnormal neuroimaging findings among hospitalized patients with confirmed COVID-19 and outcomes. Data elements including patient demographics, neuroimaging findings, acuity of neurological symptoms and/or imaging findings relative to COVID-19 onset (acute, subacute, chronic), and patient outcomes were recorded and summarized. RESULTS: After review of 775 unique articles, a total of 39 studies comprising 884 COVID-19 patients ≥ 18 years of age with abnormal neuroimaging findings and reported outcomes were included in our analysis. Ischemic stroke was the most common neuroimaging finding reported (49.3%, 436/884) among patients with mortality outcomes data. Patients with intracranial hemorrhage (ICH) had the highest all-cause mortality (49.7%, 71/143), followed by patients with imaging features consistent with leukoencephalopathy (38.5%, 5/13), and ischemic stroke (30%, 131/436). There was no mortality reported among COVID-19 patients with acute disseminated encephalomyelitis without necrosis (0%, 0/8) and leptomeningeal enhancement alone (0%, 0/12). Stroke was a common acute or subacute neuroimaging finding, while leukoencephalopathy was a common chronic finding. CONCLUSION: Among hospitalized COVID-19 patients with abnormal neuroimaging findings, those with ICH had the highest all-cause mortality; however, high mortality rates were also seen among COVID-19 patients with ischemic stroke in the acute/subacute period and leukoencephalopathy in the chronic period. ADVANCES IN KNOWLEDGE: Specific abnormal neuroimaging findings may portend differential mortality outcomes, providing a potential prognostic marker for hospitalized COVID-19 patients.


Assuntos
Comitês Consultivos , Encefalopatias/complicações , Encefalopatias/diagnóstico por imagem , COVID-19/complicações , Diagnóstico por Imagem/métodos , Pacientes Internados , Neuroimagem/métodos , Encéfalo/diagnóstico por imagem , Humanos , América do Norte , SARS-CoV-2 , Sociedades Médicas
12.
Clin Imaging ; 61: 84-89, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31986355

RESUMO

Patients and patient advocates express a desire to speak directly with radiologists, who are ideally suited to answer imaging-related questions and recommend for further imaging or testing. While web-based patient portals have improved patient access to reports of radiology examinations, they do little to help patients understand the report, and rarely facilitate contact with their radiologists. We implemented an alias phone number that forwarded to the smartphone of each participating radiologist and embedded it in 3896 reports over 8 months. It was embedded as an invitation to the individual viewing the report to call with questions. For each call received, we logged parameters such as call duration, call reason, and required radiologist time/resources. Finally, the call was documented in the electronic medical record. Radiologists received 27 calls exclusively about cross-sectional exams: 22 from patients or caregivers, and 5 from physicians. The reasons for the calls included term definitions, correction of dictation errors, findings not specifically mentioned, and clinical impact of findings. Time spent on the phone with patients averaged 8.6 min. When including the time spent reviewing the images, patient chart, and/or literature; the total radiologist time per call was approximately 13.9 min. Averaged over all of the exams in the study, this service added 5 s to each exam. While the total call rate was low, implementation of this program required minimal effort. The aliased phone number masked the radiologist's phone number and allowed scheduled consultation hours. Even when called, the time to address questions appears to be minimal.


Assuntos
Relações Médico-Paciente , Radiologistas , Radiologia , Estudos Transversais , Humanos , Masculino , Médicos , Encaminhamento e Consulta , Telefone
13.
J Am Coll Radiol ; 15(12): 1738-1744, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30149951

RESUMO

MRI is a ubiquitous medical imaging technology typically using superconductivity to generate a strong, homogeneous, and generally ceaseless magnetic field. MRI and its magnetic field pose many safety hazards, including magnetic forces on metals, tissue heating and burns, nerve stimulation, bioeffects, acoustic noise, and contrast agent complications. The primary concern is that a wide variety of patients, staff members, technologists, and physicians can approach the incessant magnetic field, creating great potential for accidents that could occur if metals from the environment, adornments, implants, and other unintended sources are also present in or near the field. Many accidents have occurred and are occasionally reported in the United States and countries all over the world. Through carefully structured oversight and the establishment of strict guidelines regarding access, responsibilities, and training, these risks can be mitigated, and accidents can be prevented. Fortunately, there is currently a wide variety of resources available to facilitate the successful implementation of an effective MRI safety program. This article presents a general overview of and the authors' experience with an MRI safety program in terms of risk management and training. The MR safety program requirements and regulations in the United States devised by The Joint Commission and the ACR are also discussed. With these resources and a carefully selected team, the risk for MRI-related accidents can be vastly reduced if not completely eliminated.


Assuntos
Prevenção de Acidentes , Segurança de Equipamentos/normas , Imageamento por Ressonância Magnética/efeitos adversos , Segurança do Paciente/normas , Gestão de Riscos/métodos , Gestão da Segurança/normas , Meios de Contraste/efeitos adversos , Humanos , Joint Commission on Accreditation of Healthcare Organizations , Próteses e Implantes/efeitos adversos , Sociedades Médicas , Estados Unidos
14.
J Clin Imaging Sci ; 7: 17, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28589056

RESUMO

Ewing sarcoma, including classical Ewing sarcoma of the bone and primitive neuroectodermal tumors arising in bone or extraosseous primary sites, is a highly aggressive childhood neoplasm. We present two cases of Ewing sarcoma arising from the vagina in young girls. Previously reported cases in literature focused on their pathologic rather than radiographic features. We describe the spectrum of multimodality imaging appearances of Ewing sarcoma at this unusual primary site. Awareness of vaginal Ewing tumors may facilitate prompt diagnosis and lead to a different surgical approach than the more commonly encountered vaginal rhabdomyosarcoma.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA