Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Crit Care ; 28(1): 77, 2024 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-38486304

RESUMO

BACKGROUND: Posttraumatic stress disorder (PTSD) after a stay in the intensive care unit (ICU) can affect one in five ICU survivors. At the beginning of the coronavirus disease 2019 (COVID-19) pandemic, admission to the ICU for COVID-19 was stressful due to the severity of this disease. This study assessed whether admission to the ICU for COVID-19 was associated with a higher prevalence of PTSD compared with other causes of ICU admission after adjustment for pre-ICU psychological factors. METHODS: This prospective observational comparative cohort study included 31 ICUs. Eligible patients were adult ICU survivors hospitalized during the first wave of COVID-19 pandemic in France, regardless of the reason for admission. The prevalence of presumptive diagnosis of PTSD at 6 months was assessed using the PTSD Checklist for DSM-5 (PCL-5). Sociodemographics, clinical data, history of childhood trauma (Childhood Trauma Questionnaire [CTQ]), and exposure to potentially traumatic events (Life Events Checklist for DSM-5 [LEC-5]) were assessed. RESULTS: Of the 778 ICU survivors included during the first wave of COVID-19 pandemic in France, 417 and 361 were assigned to the COVID-19 and non-COVID-19 cohorts, respectively. Fourteen (4.9%) and 11 (4.9%), respectively, presented with presumptive diagnosis of PTSD at 6 months (p = 0.976). After adjusting for age, sex, severity score at admission, use of invasive mechanical ventilation, ICU duration, CTQ and LEC-5, COVID-19 status was not associated with presumptive diagnosis of PTSD using the PCL-5. Only female sex was associated with presumptive diagnosis of PTSD. However, COVID-19 patients reported significantly more intrusion and avoidance symptoms than non-COVID patients (39% vs. 29%, p = 0.015 and 27% vs. 19%, p = 0.030), respectively. The median PCL-5 score was higher in the COVID-19 than non-COVID-19 cohort (9 [3, 20] vs. 4 [2, 16], p = 0.034). CONCLUSION: Admission to the ICU for COVID-19 was not associated with a higher prevalence of PTSD compared with admission for another cause during the first wave of the COVID-19 pandemic in France. However, intrusion and avoidance symptoms were more frequent in COVID-19 patients than in non-COVID-19 patients. TRIAL REGISTRATION: Clinicaltrials.gov Identifier NCT03991611, registered on June 19, 2019.


Assuntos
COVID-19 , Testes Psicológicos , Autorrelato , Transtornos de Estresse Pós-Traumáticos , Adulto , Feminino , Humanos , Estudos de Coortes , COVID-19/epidemiologia , COVID-19/complicações , Unidades de Terapia Intensiva , Pandemias , Transtornos de Estresse Pós-Traumáticos/psicologia , Sobreviventes , Masculino
2.
Transpl Int ; 36: 11520, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37720417

RESUMO

Pancreatic graft thrombosis (PAT) is a major surgical complication, potentially leading to graft loss. The recently proposed Cambridge Pancreas Allograft Thrombosis (CPAT) grading system provides diagnostic, prognostic and therapeutic recommendations. The aim of the present study was to retrospectively assess computed tomography angiography (CTA) examinations performed routinely in simultaneous pancreas-kidney (SPK) recipients to implement the CPAT grading system and to study its association with the recipients' outcomes. We retrospectively studied 319 SPK transplant recipients, who underwent a routine CTA within the first 7 postoperative days. Analysis of the CTA scans revealed PAT in 215 patients (106 grade 1, 85 grade 2, 24 grade 3), while 104 showed no signs. Demographic data of the patients with and without PAT (thrombosis and non-thrombosis group) were not significantly different, except for the higher number of male donors in the thrombosis group. Pancreatic graft survival was significantly shorter in the thrombosis group. Graft loss due to PAT was significantly associated with grade 2 and 3 thrombosis, while it did not differ for recipients with grade 0 or grade 1 thrombosis. In conclusion, the CPAT grading system was successfully implemented in a large series of SPK transplant recipients and proved applicable in clinical practice.


Assuntos
Transplante de Rim , Transplante de Pâncreas , Humanos , Masculino , Estudos Retrospectivos , Transplante de Rim/efeitos adversos , Pâncreas , Transplante de Pâncreas/efeitos adversos , Aloenxertos
3.
Blood Purif ; 47 Suppl 3: 1-7, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30982028

RESUMO

BACKGROUND: Sepsis is a dysregulated host response to an infection and can result in organ dysfunctions and death. Extracorporeal blood purification techniques aim to improve the prognosis of these patients by modulating the unbalanced immune response. This study reports our experience with the use of the oXiris® membrane for septic shock patients requiring continuous renal replacement therapy (CRRT). SUMMARY: Thirty-one patients were diagnosed with septic shock and underwent CRRT with the oXiris® membrane between 2014 and 2019. We compared the observed hospital mortality with that predicted by the Simplified Acute Physiology Score II (SAPS II). Change in the Sequential Organ Failure Assessment (SOFA) score and of the main clinical and biological parameters over time were analyzed. Hospital mortality was lower than predicted for the most severe patients (60 vs. 91% for the [74-87] SAPS II quartile and 70 vs. 98% for the [87-163] SAPS II quartile, p < 0.02). There was no significant improvement in the SOFA score from 0h to 48 h. An 88% relative decrease in norepinephrine infusion was observed (median at 0 h was 1.69 [0.52-2.45] µg/kg/min; at 48 h it was 0.20 [0.09-1.14] µg/kg/min, p = 0.002). Lactataemia and pH were significantly improved over time. Patients with intra-abdominal sepsis as well as those with Gram-negative bacilli (GNB) infections seemed to benefit the most from the therapy. Key Messages: CRRT with the oXiris® haemofilter resulted in higher observed survival than predicted by a severity score (SAPS II) for the most severe patients. Haemodynamic status and lactataemia appeared to improve, especially in intra-abdominal sepsis and GNB infections.


Assuntos
Infecções por Bactérias Gram-Negativas , Hemofiltração , Mortalidade Hospitalar , Insuficiência de Múltiplos Órgãos , Choque Séptico , Idoso , Feminino , Infecções por Bactérias Gram-Negativas/sangue , Infecções por Bactérias Gram-Negativas/mortalidade , Infecções por Bactérias Gram-Negativas/terapia , Hemofiltração/instrumentação , Hemofiltração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência de Múltiplos Órgãos/sangue , Insuficiência de Múltiplos Órgãos/mortalidade , Insuficiência de Múltiplos Órgãos/terapia , Estudos Retrospectivos , Choque Séptico/sangue , Choque Séptico/mortalidade , Choque Séptico/terapia
4.
Euro Surveill ; 21(28)2016 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-27458712

RESUMO

In April 2014, pulmonary Pseudomonas aeruginosa and Stenotrophomonas maltophilia co-infections potentially related to bronchoscopic procedures were identified in the intensive care units of a university hospital in Lyon, France. A retrospective cohort of 157 patients exposed to bronchoscopes from 1 December 2013 to 17 June 2014 was analysed. Environmental samples of suspected endoscopes were cultured. Bronchoscope disinfection was reviewed. Ten cases of pulmonary P. aeruginosa/S. maltophilia co-infections were identified, including two patients with secondary pneumonia. Eight cases were linked to bronchoscope A1 and two to bronchoscope A2. Cultures deriving from suction valves were positive for P. aeruginosa/S. maltophilia. Exposure to bronchoscopes A1 and A2 was independently coupled with increased risk of co-infection (adjusted odds ratio (aOR) = 84.6; 95% confidence interval (CI): 9.3-771.6 and aOR = 11.8, 95% CI: 1.2-121.3). Isolates from suction valves and clinical samples presented identical pulsotypes. The audit detected deficiencies in endoscope disinfection. No further cases occurred after discontinuation of the implicated bronchoscopes and change in cleaning procedures. This outbreak of pulmonary P. aeruginosa/S. maltophilia co-infections was caused by suction valve contamination of two bronchoscopes of the same manufacturer. Our findings underscore the need to test suction valves, in addition to bronchoscope channels, for routine detection of bacteria.


Assuntos
Broncoscópios/microbiologia , Coinfecção/epidemiologia , Surtos de Doenças , Contaminação de Equipamentos , Infecções por Bactérias Gram-Negativas/epidemiologia , Infecções por Pseudomonas/epidemiologia , Pseudomonas aeruginosa/isolamento & purificação , Stenotrophomonas maltophilia/isolamento & purificação , Adulto , Idoso , França/epidemiologia , Infecções por Bactérias Gram-Negativas/diagnóstico , Humanos , Pessoa de Meia-Idade , Tipagem Molecular , Infecções por Pseudomonas/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA