Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Surg Res ; 294: 82-92, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37864962

RESUMO

INTRODUCTION: There have been no significant changes in anal cancer treatment options in 4 decades. In this study, we highlight two preclinical models designed to assess anal cancer treatments. MATERIALS AND METHODS: Transgenic K14E6/E7 mice were treated with 7, 12-dimethylbenz(a)anthracene until anal tumors developed. Mice were treated with localized radiation in addition to chemotherapy (combined-modality therapy [CMT]) and compared to no treatment control (NTC). K14E6/E7 mouse anal spheroids with and without Pik3ca mutations were isolated and treated with vehicle, LY3023414 (LY3) (a drug previously shown to be effective in cancer prevention), CMT, or CMT + LY3. RESULTS: In the in vivo model, there was a significant increase in survival in the CMT group compared to the NTC group (P = 0.0392). In the ex vivo model, there was a significant decrease in the mean diameter of CMT and CMT + LY3-treated spheroids compared to vehicle (P ≤ 0.0001). For LY3 alone compared to vehicle, there was a statistically significant decrease in spheroid size in the K14E6/E7 group without mutation (P = 0.0004). CONCLUSIONS: We have provided proof of concept for two preclinical anal cancer treatment models that allow for the future testing of novel therapies for anal cancer.


Assuntos
Neoplasias do Ânus , Carcinoma de Células Escamosas , Camundongos , Animais , Camundongos Transgênicos , Terapia Combinada , Neoplasias do Ânus/terapia , Neoplasias do Ânus/patologia , Canal Anal/patologia , Carcinoma de Células Escamosas/patologia
2.
J Appl Clin Med Phys ; 25(1): e14229, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38032123

RESUMO

BACKGROUND: Pulsed reduced dose rate (PRDR) is an emerging radiotherapy technique for recurrent diseases. It is pertinent that the linac beam characteristics are evaluated for PRDR dose rates and a suitable dosimeter is employed for IMRT QA. PURPOSE: This study sought to investigate the pulse characteristics of a 6 MV photon beam during PRDR irradiations on a commercial linac. The feasibility of using EBT3 radiochromic film for use in IMRT QA was also investigated by comparing its response to a commercial diode array phantom. METHODS: A plastic scintillator detector was employed to measure the photon pulse characteristics across nominal repetition rates (NRRs) in the 5-600 MU/min range. Film was irradiated with dose rates in the 0.033-4 Gy/min range to study the dose rate dependence. Five clinical PRDR treatment plans were selected for IMRT QA with the Delta4 phantom and EBT3 film sheets. The planned and measured dose were compared using gamma analysis with a criterion of 3%/3 mm. EBT3 film QA was performed using a cumulative technique and a weighting factor technique. RESULTS: Negligible differences were observed in the pulse width and height data between the investigated NRRs. The pulse width was measured to be 3.15 ± 0.01 µ s $\mu s$ and the PRF was calculated to be 3-357 Hz for the 5-600 MU/min NRRs. The EBT3 film was found to be dose rate independent within 3%. The gamma pass rates (GPRs) were above 99% and 90% for the Delta4 phantom and the EBT3 film using the cumulative QA method, respectively. GPRs as low as 80% were noted for the weighting factor EBT3 QA method. CONCLUSIONS: Altering the NRRs changes the mean dose rate while the instantaneous dose rate remains constant. The EBT3 film was found to be suitable for PRDR dosimetry and IMRT QA with minimal dose rate dependence.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Dosimetria Fotográfica/métodos , Radiometria , Raios gama , Fótons
3.
J Appl Clin Med Phys ; 24(8): e13990, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37031363

RESUMO

BACKGROUND: Quality assurance measurement of IMRT/VMAT treatment plans is resource intensive, and other more efficient methods to achieve the same confidence are desirable. PURPOSE: We aimed to analyze treatment plans in the context of the treatment planning systems that created them, in order to predict which ones will fail a standard quality assurance measurement. To do so, we sought to create a tool external to the treatment planning system that could analyze a set of MLC positions and provide information that could be used to calculate various evaluation metrics. METHODS: The tool was created in Python to read in DICOM plan files and determine the beam fluence fraction incident on each of seven different zones, each classified based on the RayStation MLC model. The fractions, termed grid point fractions, were validated by analyzing simple test plans. The average grid point fractions, over all control points for 46 plans were then computed. These values were then compared with gamma analysis pass percentages and median dose differences to determine if any significant correlations existed. RESULTS: Significant correlation was found between the grid point fraction metrics and median dose differences, but not with gamma analysis pass percentages. Correlations were positive or negative, suggesting differing model parameter value sensitivities, as well as potential insight into the treatment planning system dose model. CONCLUSIONS: By decomposing MLC control points into different transmission zones, it is possible to create a metric that predicts whether the analyzed plan will pass a quality assurance measurement from a dose calculation accuracy standpoint. The tool and metrics developed in this work have potential applications in comparing clinical beam models or identifying their weak points. Implementing the tool within a treatment planning system would also provide more potential plan optimization parameters.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Modelos Teóricos , Benchmarking , Imagens de Fantasmas , Dosagem Radioterapêutica
4.
J Appl Clin Med Phys ; 24(3): e13829, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36808798

RESUMO

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines (MPPGs) will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: (1) Must and must not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. (2) Should and should not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances. Approved by AAPM's Executive Committee April 28, 2022.


Assuntos
Braquiterapia , Radioterapia (Especialidade) , Humanos , Estados Unidos , Física Médica/educação , Sociedades
5.
J Appl Clin Med Phys ; 23(6): e13648, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35570390

RESUMO

ClearRT helical kVCT imaging for the Radixact helical tomotherapy system recently received FDA approval and is available for clinical use. The system is intended to enhance image fidelity in radiation therapy treatment planning and delivery compared to the prior MV-based onboard imaging approach. The purpose of this work was to characterize the imaging performance of this system and compare this performance with that of clinical systems used in image-guided and/or adaptive radiotherapy (ART) or computed tomography (CT) simulation, including Radixact MVCT, TomoTherapy MVCT, Varian TrueBeam kV OBI CBCT, and the Siemens SOMATOM Definition Edge kVCT. A CT image quality phantom was scanned across clinically relevant acquisition modes for each system to evaluate image quality metrics, including noise, uniformity, contrast, spatial resolution, and CT number linearity. Similar noise levels were observed for ClearRT and Siemens Edge, whereas noise for the other systems was ∼1.5-5 times higher. Uniformity was best for Siemens Edge, whereas most scans for ClearRT exhibited a slight "cupping" or "capping" artifact. The ClearRT and Siemens Edge performed best for contrast metrics, which included low-contrast visibility and contrast-to-noise ratio evaluations. Spatial resolution was best for TrueBeam and Siemens Edge, whereas the three kVCT systems exhibited similar CT number linearity. Overall, these results provide an initial indication that ClearRT image quality is adequate for image guidance in radiotherapy and sufficient for delineating anatomic structures, thus enabling its use for ART. ClearRT also showed significant improvement over MVCT, which was previously the only onboard imaging modality available on Radixact. Although the acquisition of these scans does come at the cost of additional patient dose, reported CTDI values indicate a similar or generally reduced machine output for ClearRT compared to the other systems while maintaining comparable or improved image quality overall.


Assuntos
Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
6.
J Appl Clin Med Phys ; 23(7): e13627, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35486094

RESUMO

Tracking systems such as Radixact Synchrony change the planned delivery of radiation during treatment to follow the target. This is typically achieved without considering the location changes of organs at risk (OARs). The goal of this work was to develop a novel 4D dose accumulation framework to quantify OAR dose deviations due to the motion and tracked treatment. The framework obtains deformation information and the target motion pattern from a four-dimensional computed tomography dataset. The helical tomotherapy treatment plan is split into 10 plans and motion correction is applied separately to the jaw pattern and multi-leaf collimator (MLC) sinogram for each phase based on the location of the target in each phase. Deformable image registration (DIR) is calculated from each phase to the references phase using a commercial algorithm, and doses are accumulated according to the DIR. The effect of motion synchronization on OAR dose was analyzed for five lung and five liver subjects by comparing planned versus synchrony-accumulated dose. The motion was compensated by an average of 1.6 cm of jaw sway and by an average of 5.7% of leaf openings modified, indicating that most of the motion compensation was from jaw sway and not MLC changes. OAR dose deviations as large as 19 Gy were observed, and for all 10 cases, dose deviations greater than 7 Gy were observed. Target dose remained relatively constant (D95% within 3 Gy), confirming that motion-synchronization achieved the goal of maintaining target dose. Dose deviations provided by the framework can be leveraged during the treatment planning process by identifying cases where OAR doses may change significantly from their planned values with respect to the critical constraints. The framework is specific to synchronized helical tomotherapy treatments, but the OAR dose deviations apply to any real-time tracking technique that does not consider location changes of OARs.


Assuntos
Neoplasias Pulmonares , Radioterapia de Intensidade Modulada , Humanos , Fígado , Pulmão , Neoplasias Pulmonares/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
7.
J Appl Clin Med Phys ; 22(5): 175-181, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33779041

RESUMO

PURPOSE: Radixact Synchrony corrects for target motion during treatment by adjusting the jaw and MLC positions in real time. As the jaws move off axis, Synchrony attempts to adjust for a loss in output due to the un-flattened 6 MV beam by increasing the jaw aperture width. The purpose of this work was to assess the impact of the variable-width aperture on delivered dose using measurements and simulations. METHODS: Longitudinal beam profile measurements were acquired using an Edge diode with static gantry. Jaw-offset peak, width, and integral factors were calculated for profiles with the jaws in the extreme positions using both variable-width (Synchrony) and fixed-width apertures. Treatment plans with target motion and compensation were compared to planned doses to study the impact of the variable aperture on volumetric dose. RESULTS: The jaw offset peak factor (JOPF) for the Synchrony jaw settings were 0.964 and 0.983 for the 1.0- and 2.5-cm jaw settings, respectively. These values decreased to 0.925 and 0.982 for the fixed-width settings, indicating that the peak value of the profile would decrease by 7.5% compared to centered if the aperture width was held constant. The IMRT dose distributions reveal similar results, where gamma pass rates are above tolerance for the Synchrony jaw settings but fall significantly for the fixed-width 1-cm jaws. CONCLUSIONS: The variable-width behavior of Synchrony jaws provides a larger output correction for the 1-cm jaw setting. Without the variable-aperture correction, plans with the 1-cm jaw setting would underdose the target if the jaws spend a significant amount of time in the extreme positions. This work investigated the change in delivered dose with jaws in the extreme positions, therefore overall changes in dose due to offset jaws are expected to be less for composite treatment deliveries.


Assuntos
Arcada Osseodentária , Radioterapia de Intensidade Modulada , Humanos , Movimento (Física) , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
8.
J Appl Clin Med Phys ; 22(9): 227-231, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34309182

RESUMO

Kilovoltage radiographs are acquired during motion-synchronized treatments on Radixact to localize the tumor during the treatment. Several previous publications have provided estimates of patient dose from these planar radiographs. However, a recent hardware update changed several aspects of the kV imaging system, including a new X-ray tube, an extended source-to-axis distance (SAD), and a larger field size. This is denoted the extended configuration. The purpose of this work was to assess the impact of the configuration change on patient dose from these procedures. Point doses in water were measured using the TG-61 protocol for tube potentials between 100 and 140 kVp for both the standard and extended configurations under the same water tank setup. Comparisons were made for equal mAs since the same protocols (kVp, mAs) will be used for both configurations. In comparison to the standard configuration, doses per mAs from the extended configuration were found to be ~66% less and falloff less steep due to the increased SAD. However, a larger volume of tissue is irradiated due to the larger field size. Beam quality for a given tube potential was the same as determined by half-value layer measurements. Both kV configurations are available from the vendor, therefore, the values in this work can be used to compare values previously published in the literature for the standard configuration or to intercompare doses from these two system configurations.


Assuntos
Imagens de Fantasmas , Fluoroscopia , Humanos , Movimento (Física) , Doses de Radiação , Radiografia
9.
J Appl Clin Med Phys ; 21(9): 96-106, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32691973

RESUMO

The Radixact® linear accelerator contains the motion Synchrony system, which tracks and compensates for intrafraction patient motion. For respiratory motion, the system models the motion of the target and synchronizes the delivery of radiation with this motion using the jaws and multi-leaf collimators (MLCs). It was the purpose of this work to determine the ability of the Synchrony system to track and compensate for different phantom motions using a delivery quality assurance (DQA) workflow. Thirteen helical plans were created on static datasets from liver, lung, and pancreas subjects. Dose distributions were measured using a Delta4® Phantom+ mounted on a Hexamotion® stage for the following three case scenarios for each plan: (a) no phantom motion and no Synchrony (M0S0), (b) phantom motion and no Synchrony (M1S0), and (c) phantom motion with Synchrony (M1S1). The LEDs were placed on the Phantom+ for the 13 patient cases and were placed on a separate one-dimensional surrogate stage for additional studies to investigate the effect of separate target and surrogate motion. The root-mean-square (RMS) error between the Synchrony-modeled positions and the programmed phantom positions was <1.5 mm for all Synchrony deliveries with the LEDs on the Phantom+. The tracking errors increased slightly when the LEDs were placed on the surrogate stage but were similar to tracking errors observed for other motion tracking systems such as CyberKnife Synchrony. One-dimensional profiles indicate the effects of motion interplay and dose blurring present in several of the M1S0 plans that are not present in the M1S1 plans. All 13 of the M1S1 measured doses had gamma pass rates (3%/2 mm/10%T) compared to the planned dose > 90%. Only two of the M1S0 measured doses had gamma pass rates > 90%. Motion Synchrony offers a potential alternative to the current, ITV-based motion management strategy for helical tomotherapy deliveries.


Assuntos
Radiometria , Radioterapia de Intensidade Modulada , Humanos , Pulmão , Movimento (Física) , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador
10.
J Bacteriol ; 201(8)2019 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-30692176

RESUMO

In previous work (D. R. Harris et al., J Bacteriol 191:5240-5252, 2009, https://doi.org/10.1128/JB.00502-09; B. T. Byrne et al., Elife 3:e01322, 2014, https://doi.org/10.7554/eLife.01322), we demonstrated that Escherichia coli could acquire substantial levels of resistance to ionizing radiation (IR) via directed evolution. Major phenotypic contributions involved adaptation of organic systems for DNA repair. We have now undertaken an extended effort to generate E. coli populations that are as resistant to IR as Deinococcus radiodurans After an initial 50 cycles of selection using high-energy electron beam IR, four replicate populations exhibit major increases in IR resistance but have not yet reached IR resistance equivalent to D. radiodurans Regular deep sequencing reveals complex evolutionary patterns with abundant clonal interference. Prominent IR resistance mechanisms involve novel adaptations to DNA repair systems and alterations in RNA polymerase. Adaptation is highly specialized to resist IR exposure, since isolates from the evolved populations exhibit highly variable patterns of resistance to other forms of DNA damage. Sequenced isolates from the populations possess between 184 and 280 mutations. IR resistance in one isolate, IR9-50-1, is derived largely from four novel mutations affecting DNA and RNA metabolism: RecD A90E, RecN K429Q, and RpoB S72N/RpoC K1172I. Additional mechanisms of IR resistance are evident.IMPORTANCE Some bacterial species exhibit astonishing resistance to ionizing radiation, with Deinococcus radiodurans being the archetype. As natural IR sources rarely exceed mGy levels, the capacity of Deinococcus to survive 5,000 Gy has been attributed to desiccation resistance. To understand the molecular basis of true extreme IR resistance, we are using experimental evolution to generate strains of Escherichia coli with IR resistance levels comparable to Deinococcus Experimental evolution has previously generated moderate radioresistance for multiple bacterial species. However, these efforts could not take advantage of modern genomic sequencing technologies. In this report, we examine four replicate bacterial populations after 50 selection cycles. Genomic sequencing allows us to follow the genesis of mutations in populations throughout selection. Novel mutations affecting genes encoding DNA repair proteins and RNA polymerase enhance radioresistance. However, more contributors are apparent.


Assuntos
Evolução Biológica , Escherichia coli/genética , Escherichia coli/efeitos da radiação , Tolerância a Radiação , Radiação Ionizante , Seleção Genética , Análise Mutacional de DNA , Enzimas Reparadoras do DNA/genética , RNA Polimerases Dirigidas por DNA/genética , Deinococcus/crescimento & desenvolvimento , Deinococcus/efeitos da radiação , Escherichia coli/crescimento & desenvolvimento , Sequenciamento de Nucleotídeos em Larga Escala , Mutação
11.
J Appl Clin Med Phys ; 20(8): 122-133, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31355997

RESUMO

PURPOSE: End-to-end testing with quality assurance (QA) phantoms for deformable dose accumulation and real-time image-guided radiotherapy (IGRT) has recently been recommended by American Association of Physicists in Medicine (AAPM) Task Groups 132 and 76. The goal of this work was to develop a deformable abdominal phantom containing a deformable three-dimensional dosimeter that could provide robust testing of these systems. METHODS: The deformable abdominal phantom was fabricated from polyvinyl chloride plastisol and phantom motion was simulated with a programmable motion stage and plunger. A deformable normoxic polyacrylamide gel (nPAG) dosimeter was incorporated into the phantom apparatus to represent a liver tumor. Dosimeter data were acquired using magnetic resonance imaging (MRI). Static measurements were compared to planned dose distributions. Static and dynamic deformations were used to simulate inter- and intrafractional motion in the phantom and measurements were compared to baseline measurements. RESULTS: The statically irradiated dosimeters matched the planned dose distribution with an average γ pass rates of 97.0 ± 0.5% and 97.5 ± 0.2% for 3%/5 mm and 5%/5 mm criteria, respectively. Static deformations caused measured dose distribution shifts toward the phantom plunger. During the dynamic deformation experiment, the dosimeter that utilized beam gating showed an improvement in the γ pass rate compared to the dosimeter that did not. CONCLUSIONS: A deformable abdominal phantom apparatus which incorporates a deformable nPAG dosimeter was developed to test real-time IGRT systems and deformable dose accumulation algorithms. This apparatus was used to benchmark simple static irradiations in which it was found that measurements match well to the planned distributions. Deformable dose accumulation could be tested by directly measuring the shifts and blurring of the target dose due to interfractional organ deformation and motion. Dosimetric improvements were achieved from the motion management during intrafractional motion.


Assuntos
Abdome/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Simulação por Computador , Humanos , Neoplasias/radioterapia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos
12.
J Appl Clin Med Phys ; 20(12): 25-35, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31675460

RESUMO

Patient dose from 2.5 MV images on the TrueBeam linear accelerator is not easily quantified, primarily because this beam energy is not normally modeled by commercial treatment planning systems. In this work we present the feasibility of using the Eclipse® treatment planning system to model this beam. The Acuros XB and the AAA dose calculation algorithms were tested. Profiles, PDDs, and output factors were measured for the 2.5 MV unflattened imaging beam and used for beam modeling. The algorithms were subsequently verified using MPPG 5.a guidelines. Calculated doses with both algorithms agreed with the measurement data to within the following criteria recommended for conventional therapeutic MV beams: 2% local dose-difference in the high-dose region, 3% global difference in the low-dose region, 3 mm distance to agreement in the penumbra, and a gamma pass rate of >95% for 3%/3 mm criteria. Acuros was able to accurately calculate dose through cork and bone-equivalent heterogeneities. AAA was able to accurately calculate dose through the bone-equivalent heterogeneity but did not pass within the recommended criteria for the cork heterogeneity. For the 2.5 MV imaging beam, both the AAA and Acuros algorithms provide calculated doses that agree with measured results well within the 20% criteria for imaging beams recommended by AAPM TG-180.


Assuntos
Algoritmos , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Planejamento de Assistência ao Paciente/normas , Imagens de Fantasmas , Fótons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica
13.
J Appl Clin Med Phys ; 18(4): 161-171, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28681448

RESUMO

The ArcCHECK-MR diode array utilizes a correction system with a virtual inclinometer to correct the angular response dependencies of the diodes. However, this correction system cannot be applied to measurements on the ViewRay MR-IGRT system due to the virtual inclinometer's incompatibility with the ViewRay's multiple simultaneous beams. Additionally, the ArcCHECK's current correction factors were determined without magnetic field effects taken into account. In the course of performing ViewRay IMRT quality assurance with the ArcCHECK, measurements were observed to be consistently higher than the ViewRay TPS predictions. The goals of this study were to quantify the observed discrepancies and test whether applying the current factors improves the ArcCHECK's accuracy for measurements on the ViewRay. Gamma and frequency analysis were performed on 19 ViewRay patient plans. Ion chamber measurements were performed at a subset of diode locations using a PMMA phantom with the same dimensions as the ArcCHECK. A new method for applying directionally dependent factors utilizing beam information from the ViewRay TPS was developed in order to analyze the current ArcCHECK correction factors. To test the current factors, nine ViewRay plans were altered to be delivered with only a single simultaneous beam and were measured with the ArcCHECK. The current correction factors were applied using both the new and current methods. The new method was also used to apply corrections to the original 19 ViewRay plans. It was found the ArcCHECK systematically reports doses higher than those actually delivered by the ViewRay. Application of the current correction factors by either method did not consistently improve measurement accuracy. As dose deposition and diode response have both been shown to change under the influence of a magnetic field, it can be concluded the current ArcCHECK correction factors are invalid and/or inadequate to correct measurements on the ViewRay system.


Assuntos
Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias/radioterapia , Humanos , Imagem por Ressonância Magnética Intervencionista/instrumentação , Neoplasias/diagnóstico por imagem , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
14.
J Appl Clin Med Phys ; 18(3): 182-190, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28397396

RESUMO

PURPOSE: To present the results and discuss potential insights gained through surveys on reference dosimetry practices. METHODS: Two surveys were sent to medical physicists to learn about the current state of reference dosimetry practices at radiation oncology clinics worldwide. A short survey designed to maximize response rate was made publicly available and distributed via the AAPM website and a medical physics list server. Another, much more involved survey, was sent to a smaller group of physicists to gain insight on detailed dosimetry practices. The questions were diverse, covering reference dosimetry practices on topics like measurements required for beam quality specification, the actual measurement of absorbed dose and ancillary equipment required like electrometers and environment monitoring measurements. RESULTS: There were 190 respondents to the short survey and seven respondents to the detailed survey. The diversity of responses indicates nonuniformity in reference dosimetry practices and differences in interpretation of reference dosimetry protocols. CONCLUSIONS: The results of these surveys offer insight on clinical reference dosimetry practices and will be useful in identifying current and future needs for reference dosimetry.


Assuntos
Institutos de Câncer/normas , Pesquisas sobre Atenção à Saúde , Radiometria/normas , Humanos , Padrões de Referência
15.
Artigo em Inglês | MEDLINE | ID: mdl-31452665

RESUMO

Normoxic Polyacrylamide Gels, or nPAGs, are 3D gel dosimeters that measure dose through the process of radiation-induced polymerization. Two nPAG formulae are DEFGEL and PAGAT, which are very similar, but differ mainly due to different weight fractions of monomers. The dosimetric resolutions of the two formulae when paired with a Spin-Echo (SE) MRI sequence and a monoexponential fit were compared over a range of 0-15 Gy. It was found that in the dose range 0-6 Gy the PAGAT formula generally showed a much finer dose resolution, while the DEFGEL formula showed a finer resolution from 8-15 Gy.

16.
Phys Med Biol ; 69(12)2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38776951

RESUMO

Objective.In this work, we present and evaluate a technique for performing interface measurements of beta particle-emitting radiopharmaceutical therapy agents in solution.Approach.Unlaminated EBT3 film was calibrated for absorbed dose to water using a NIST matched x-ray beam. Custom acrylic source phantoms were constructed and placed above interfaces comprised of bone, lung, and water-equivalent materials. The film was placed perpendicular to these interfaces and measurements for absorbed dose to water using solutions of90Y and177Lu were performed and compared to Monte Carlo absorbed dose to water estimates simulated with EGSnrc. Surface and depth dose profile measurements were also performed.Main results.Surface absorbed dose to water measurements agreed with predicted results within 3.6% for177Lu and 2.2% for90Y. The agreement between predicted and measured absorbed dose to water was better for90Y than177Lu for depth dose and interface profiles. In general, agreement withink= 1 uncertainty bounds was observed for both radionuclides and all interfaces. An exception to this was found for the bone-to-water interface for177Lu due to the increased sensitivity of the measurements to imperfections in the material surfaces.Significance. This work demonstrates the feasibility and limitations of using radiochromic film for performing absorbed dose to water measurements on beta particle-emitting radiopharmaceutical therapy agents across material interfaces.


Assuntos
Partículas beta , Método de Monte Carlo , Compostos Radiofarmacêuticos , Partículas beta/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico , Compostos Radiofarmacêuticos/administração & dosagem , Radiometria/instrumentação , Radiometria/métodos , Imagens de Fantasmas , Água/química , Radioisótopos de Ítrio/uso terapêutico , Humanos
17.
Med Phys ; 51(11): 8597-8601, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39106411

RESUMO

BACKGROUND: The C Q $C_Q$ formalism proposed by Watson et al. allows users of the INTRABEAM (Carl Zeiss Medical AG, Jena, Germany) electronic brachytherapy system to accurately determine the absorbed dose to water, in the absence of a primary dosimetry standard. However, all published C Q $C_Q$ values are for PTW 34013 ionization chambers calibrated in a TW30 reference beam, traceable to PTB (Germany). For North American users, it would be advantageous to have C Q $C_Q$ data for chambers calibrated in a kV reference beam maintained by the National Institute of Standards and Technology (NIST). PURPOSE: In this work, we determine C Q $C_Q$ for a PTW 34013 chamber calibrated in three NIST-traceable reference beams: M30, L40, and L50. METHODS: Using available photon spectra data for M30, L40, and L50 reference beam qualities, Monte Carlo simulations using EGSnrc were performed to calculate the ratio of the absorbed dose to the PTW 34013 chamber air cavity to air-kerma ( D gas / K a $D_{\textrm {gas}}/K_a$ ) for these beams. From this ratio, C Q $C_Q$ as a function of depth in water was determined. The effect of the use of a buildup foil was also investigated. An uncertainty analysis considering both the Type A and Type B uncertainties in the calculation of C Q $C_Q$ was performed. RESULTS: The largest difference in C Q $C_Q$ was found between L50 and TW30, with a relative decrease of 1.4% (no buildup) to 1.6% (buildup). For M30 and L40, the differences were minimal compared with measurement uncertainties. CONCLUSIONS: We report C Q $C_Q$ values for three NIST-traceable kV reference beams. This study reinforces the feasibility of adapting the Watson et al. methodology using different kV reference beams, facilitating the use of INTRABEAM in North America and ensuring the continuity and accuracy of dosimetry standards in intraoperative radiation therapy.


Assuntos
Método de Monte Carlo , Radiometria , Calibragem , Radiometria/instrumentação , Radiometria/economia , Raios X , Padrões de Referência , Incerteza , Braquiterapia/instrumentação , Braquiterapia/economia
18.
Med Phys ; 51(8): 5693-5707, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38669453

RESUMO

BACKGROUND: Clinical intensity modulated radiation therapy plans have been described using various complexity metrics to help identify problematic radiotherapy plans. Most previous studies related to the quantification of plan complexity and their utility have relied on institution-specific plans which can be highly variable depending on the machines, planning techniques, delivery modalities, and measurement devices used. In this work, 1723 plans treating one of only four standardized geometries were simultaneously analyzed to investigate how radiation plan complexity metrics vary across four different sets of common objectives. PURPOSE: To assess the treatment plan complexity characteristics of plans developed for Imaging and Radiation Oncology Core (IROC) phantoms. Specifically, to understand the variability in plan complexity between institutions for a common plan objective, and to evaluate how various complexity metrics differentiate relevant groups of plans. METHODS: 1723 plans treating one of four standardized IROC phantom geometries representing four different anatomical sites of treatment were analyzed. For each plan, 22 MLC-descriptive plan complexity metrics were calculated, and principal component analysis (PCA) was applied to the 22 metrics in order to evaluate differences in plan complexity between groups. Across all metrics, pairwise comparisons of the IROC phantom data were made for the following classifications of the data: anatomical phantom treated, treatment planning system (TPS), and the combination of MLC model and treatment planning system. An objective k-means clustering algorithm was also applied to the data to determine if any meaningful distinctions could be made between different subgroups. The IROC phantom database was also compared to a clinical database from the University of Wisconsin-Madison (UW) which included plans treating the same four anatomical sites as the IROC phantoms using a TrueBeam™ STx and Pinnacle3 TPS. RESULTS: The IROC head and neck and spine plans were distinct from the prostate and lung plans based on comparison of the 22 metrics. All IROC phantom plan group complexity metric distributions were highly variable despite all plans being designed for identical geometries and plan objectives. The clusters determined by the k-means algorithm further supported that the IROC head and neck and spine plans involved similar amounts of complexity and were largely distinct from the prostate and lung plans, but no further distinctions could be made. Plan complexity in the head and neck and spine IROC phantom plans were similar to the complexity encountered in the UW clinical plans. CONCLUSIONS: There is substantial variability in plan complexity between institutions when planning for the same objective. For each IROC anatomical phantom treated, the magnitude of variability in plan complexity between institutions is similar to the variability in plan complexity encountered within a single institution database containing several hundred unique clinical plans treating corresponding anatomies in actual patients.


Assuntos
Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Análise de Componente Principal , Dosagem Radioterapêutica
19.
Med Phys ; 51(4): 2998-3009, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38060696

RESUMO

BACKGROUND: The static magnetic field present in magnetic resonance (MR)-guided radiotherapy systems can influence dose deposition and charged particle collection in air-filled ionization chambers. Thus, accurately quantifying the effect of the magnetic field on ionization chamber response is critical for output calibration. Formalisms for reference dosimetry in a magnetic field have been proposed, whereby a magnetic field quality conversion factor kB,Q is defined to account for the combined effects of the magnetic field on the radiation detector. Determination of kB,Q in the literature has focused on Monte Carlo simulation studies, with experimental validation limited to only a few ionization chamber models. PURPOSE: The purpose of this study is to experimentally measure kB,Q for 11 ionization chamber models in two commercially available MR-guided radiotherapy systems: Elekta Unity and ViewRay MRIdian. METHODS: Eleven ionization chamber models were characterized in this study: Exradin A12, A12S, A28, and A26, PTW T31010, T31021, and T31022, and IBA FC23-C, CC25, CC13, and CC08. The experimental method to measure kB,Q utilized cross-calibration against a reference Exradin A1SL chamber. Absorbed dose to water was measured for the reference A1SL chamber positioned parallel to the magnetic field with its centroid placed at the machine isocenter at a depth of 10 cm in water for a 10 × 10 cm2 field size at that depth. Output was subsequently measured with the test chamber at the same point of measurement. kB,Q for the test chamber was computed as the ratio of reference dose to test chamber output, with this procedure repeated for each chamber in each MR-guided radiotherapy system. For the high-field 1.5 T Elekta Unity system, the dependence of kB,Q on the chamber orientation relative to the magnetic field was quantified by rotating the chamber about the machine isocenter. RESULTS: Measured kB,Q values for our test dataset of ionization chamber models ranged from 0.991 to 1.002, and 0.995 to 1.004 for the Elekta Unity and ViewRay MRIdian, respectively, with kB,Q tending to increase as the chamber sensitive volume increased. Measured kB,Q values largely agreed within uncertainty to published Monte Carlo simulation data and available experimental data. kB,Q deviation from unity was minimized for ionization chamber orientation parallel or antiparallel to the magnetic field, with increased deviations observed at perpendicular orientations. Overall (k = 1) uncertainty in the experimental determination of the magnetic field quality conversion factor, kB,Q was 0.71% and 0.72% for the Elekta Unity and ViewRay MRIdian systems, respectively. CONCLUSIONS: For a high-field MR-linac, the characterization of ionization chamber performance as angular orientation varied relative to the magnetic field confirmed that the ideal orientation for output calibration is parallel. For most of these chamber models, this study represents the first experimental characterization of chamber performance in clinical MR-linac beams. This is a critical step toward accurate output calibration for MR-guided radiotherapy systems and the measured kB,Q values will be an important reference data source for forthcoming MR-linac reference dosimetry protocols.


Assuntos
Radiometria , Radioterapia Guiada por Imagem , Eficiência Biológica Relativa , Campos Magnéticos , Método de Monte Carlo , Água
20.
Phys Med Biol ; 69(11)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38684165

RESUMO

Objective. This work introduces a novel approach to performing active and passive dosimetry for beta-emitting radionuclides in solution using common dosimeters. The measurements are compared to absorbed dose to water (Dw) estimates from Monte Carlo (MC) simulations. We present a method for obtaining absorbed dose to water, measured with dosimeters, from beta-emitting radiopharmaceutical agents using a custom SPECT/CT compatible phantom for validation of Monte Carlo based absorbed dose to water estimates.Approach. A cylindrical, acrylic SPECT/CT compatible phantom capable of housing an IBA EFD diode, Exradin A20-375 parallel plate ion chamber, unlaminated EBT3 film, and thin TLD100 microcubes was constructed for the purpose of measuring absorbed dose to water from solutions of common beta-emitting radiopharmaceutical therapy agents. The phantom is equipped with removable detector inserts that allow for multiple configurations and is designed to be used for validation of image-based absorbed dose estimates with detector measurements. Two experiments with131I and one experiment with177Lu were conducted over extended measurement intervals with starting activities of approximately 150-350 MBq. Measurement data was compared to Monte Carlo simulations using the egs_chamber user code in EGSnrc 2019.Main results. Agreement withink= 1 uncertainty between measured and MC predictedDwwas observed for all dosimeters, except the A20-375 ion chamber during the second131I experiment. Despite the agreement, the measured values were generally lower than predicted values by 5%-15%. The uncertainties atk = 1 remain large (5%-30% depending on the dosimeter) relative to other forms of radiation therapy.Significance. Despite high uncertainties, the overall agreement between measured and simulated absorbed doses is promising for the use of dosimeter-based RPT measurements in the validation of MC predictedDw.


Assuntos
Partículas beta , Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Radiometria/instrumentação , Partículas beta/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico , Compostos Radiofarmacêuticos/química , Radioisótopos do Iodo/uso terapêutico , Lutécio/química , Água/química , Radioisótopos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA