Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Labelled Comp Radiopharm ; 66(1): 11-21, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36453978

RESUMO

This paper describes the deuterium-labelling of alkylnitroaromatics by base-catalysed exchange with deuterium oxide. As the alkyl protons alpha to the aromatic ring are the most acidic sites in the molecule, regioselective hydrogen isotope exchange at this benzylic location leads to a regiospecifically deuterated product. The exchange labelling takes place in good yields and with high atom% abundance in the presence of an appropriate nitrogen base. Alkylated 2,4-dinitrobenzenes deuterate at room temperature under catalysis by triethylamine, whilst alkylated 2-nitro- or 4-nitrobenzenes and related mono-nitroaromatics require higher temperatures and catalysis by 1,5-diazobicyclo[4.3.0]non-5-ene (DBN). The labelling reactions require an inert gas atmosphere, but otherwise are simple and high yielding with no obvious byproducts. Those compounds in which the benzylic protons are in an ortho-orientation with respect to the nitro group label somewhat more slowly than the analogues where there is a para relationship. In addition, higher alkyl homologues undergo benzylic deuteration at slower rates than methyl.


Assuntos
Aminas , Prótons , Óxido de Deutério , Hidrogênio , Catálise
2.
COPD ; 20(1): 186-196, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37395048

RESUMO

Computed tomography (CT) total-airway-count (TAC) and airway wall-thickness differ across chronic obstructive pulmonary disease (COPD) severities, but longitudinal insights are lacking. The aim of this study was to evaluate longitudinal CT airway measurements over three-years in ex-smokers. In this prospective convenience sample study, ex-smokers with (n = 50; 13 female; age = 70 ± 9 years; pack-years = 43 ± 26) and without (n = 40; 17 female; age = 69 ± 10 years; pack-years = 31 ± 17) COPD completed CT, 3He magnetic resonance imaging (MRI), and pulmonary function tests at baseline and three-year follow-up. CT TAC, airway wall-area (WA), lumen-area (LA), and wall-area percent (WA%) were generated. Emphysema was quantified as the relative-area-of-the-lung with attenuation < -950 Hounsfield-units (RA950). MRI ventilation-defect-percent (VDP) was also quantified. Differences over time were evaluated using paired-samples t tests. Multivariable prediction models using the backwards approach were generated. After three-years, forced-expiratory-volume in 1-second (FEV1) was not different in ex-smokers with (p = 0.4) and without (p = 0.5) COPD, whereas RA950 was (p < 0.001, p = 0.02, respectively). In ex-smokers without COPD, there was no change in TAC (p = 0.2); however, LA (p = 0.009) and WA% (p = 0.01) were significantly different. In ex-smokers with COPD, TAC (p < 0.001), WA (p = 0.04), LA (p < 0.001), and WA% (p < 0.001) were significantly different. In all ex-smokers, TAC was related to VDP (baseline: ρ = -0.30, p = 0.005; follow-up: ρ = -0.33, p = 0.002). In significant multivariable models, baseline airway wall-thickness was predictive of TAC worsening. After three-years, in the absence of FEV1 worsening, TAC diminished only in ex-smokers with COPD and airway walls were thinner in all ex-smokers. These longitudinal findings suggest that the evaluation of CT airway remodeling may be a useful clinical tool for predicting disease progression and managing COPD.Clinical trial registration: www.clinicaltrials.gov NCT02279329.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Ex-Fumantes , Pulmão/diagnóstico por imagem , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem
3.
Scand J Med Sci Sports ; 32(4): 654-671, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34981853

RESUMO

Sport officials make significant contributions to organized sport, yet scientific evidence to inform their specialized training and education at various levels has lagged. While psychological and performance demands of expert sport officials have been well documented, the extent of research about talent and expertise development, training efficacy, and broader developmental trajectories is unclear. This systematic review summarizes 30 years of published findings on the study of training and development of sport officials, including areas of research interest, study designs, and sport official characteristics. A PRISMA systematic review was conducted, utilizing three scientific databases (Web of Science, SportsDiscus, PsycInfo) to identify relevant studies (N = 27). Female participants were generally underrepresented in studies (17%), while football officials were most often represented (79%). Training intervention (59%), retrospective (37%), and cross-sectional comparison (22%) were the main study designs. Expert and near-expert sport officials' training histories and responses to empirically driven isolated-skills training represented the predominant areas of study. Sport-specific, video-based infraction detection tasks were the most frequently used training methods to improve perceptual-cognitive skills for on-field decision-making, however, studies lacked retention measures to on-field performance. Psychological skills training programs were found to have mixed effects and used varied criteria for measuring training efficacy. Physical training showed mainly significant effects on physiological measures and aging influences for on-field performance. More rigorous sport-specific evidence, assessments of training transfer, program efficacy, and macro-developmental trajectory and milestone data are needed to inform training programs and developmental plans.


Assuntos
Futebol Americano , Futebol , Aptidão , Estudos Transversais , Feminino , Humanos , Estudos Retrospectivos , Futebol/fisiologia
4.
COPD ; 13(2): 224-34, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26606693

RESUMO

Pulmonary vascular disease is a common complication of chronic obstructive pulmonary disease (COPD), and an important risk factor for COPD exacerbations and death. We explored the relationship between pulmonary artery volumes measured using thoracic computed tomography (CT) and lung structure-function measured using spirometry, CT and magnetic resonance imaging (MRI) in 124 ex-smokers with (n = 68) and without (n = 56) airflow obstruction, and a control group of 35 never-smokers. We observed significantly greater main (p = .01), right (p = .001) and total (p = .003) pulmonary artery volumes in ex-smokers with airflow obstruction as compared to ex-smokers without airflow obstruction. There were also significantly greater pulmonary artery volumes in both ex-smoker subgroups, compared to the never-smoker subgroup (p = .008). For all participants, there were significant correlations for pulmonary artery volumes with the ratio of the forced expiratory volume in 1 s to forced vital capacity (FEV1/FVC), the diffusing capacity of the lung for carbon monoxide (DLCO%pred), airway count, MRI ventilation defect percent and MRI apparent diffusion coefficients. In ex-smokers, ventilation defect percent was significantly correlated with right (r = 0.27, p = .02) and total (r = 0.25, p = .03) pulmonary artery volumes. Multivariate zero-inflated Poisson regression analysis showed that FEV1%pred (p = .004), DLCO%pred (p = .03), the six minute walk distance (p = .04) and total pulmonary artery volume (p = .03) were significant predictors of acute exacerbations of COPD, while the number of previous exacerbations was not. In conclusion, pulmonary artery enlargement measured using thoracic CT was observed even in ex-smokers without airflow obstruction and was predictive of COPD exacerbations in ex-smokers with airflow obstruction.


Assuntos
Obstrução das Vias Respiratórias/complicações , Tolerância ao Exercício/fisiologia , Artéria Pulmonar/anormalidades , Doença Pulmonar Obstrutiva Crônica/complicações , Fumar/efeitos adversos , Malformações Vasculares/etiologia , Idoso , Idoso de 80 Anos ou mais , Obstrução das Vias Respiratórias/diagnóstico , Obstrução das Vias Respiratórias/fisiopatologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Pletismografia , Artéria Pulmonar/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Tomografia Computadorizada por Raios X , Malformações Vasculares/diagnóstico , Malformações Vasculares/fisiopatologia , Capacidade Vital
5.
J Med Imaging (Bellingham) ; 11(3): 033502, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38827778

RESUMO

Purpose: The modulation transfer function (MTF) and detective quantum efficiency (DQE) of x-ray detectors are key Fourier metrics of performance, valid only for linear and shift-invariant (LSI) systems and generally measured following IEC guidelines requiring the use of raw (unprocessed) image data. However, many detectors incorporate processing in the imaging chain that is difficult or impossible to disable, raising questions about the practical relevance of MTF and DQE testing. We investigate the impact of convolution-based embedded processing on MTF and DQE measurements. Approach: We use an impulse-sampled notation, consistent with a cascaded-systems analysis in spatial and spatial-frequency domains to determine the impact of discrete convolution (DC) on measured MTF and DQE following IEC guidelines. Results: We show that digital systems remain LSI if we acknowledge both image pixel values and convolution kernels represent scaled Dirac δ-functions with an implied sinc convolution of image data. This enables use of the Fourier transform (FT) to determine impact on presampling MTF and DQE measurements. Conclusions: It is concluded that: (i) the MTF of DC is always an unbounded cosine series; (ii) the slanted-edge method yields the true presampling MTF, even when using processed images, with processing appearing as an analytic filter with cosine-series MTF applied to raw presampling image data; (iii) the DQE is unaffected by discrete-convolution-based processing with a possible exception near zero-points in the presampling MTF; and (iv) the FT of the impulse-sampled notation is equivalent to the Z transform of image data.

6.
Front Sports Act Living ; 6: 1436149, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39135607

RESUMO

Introduction: Sport officials are tasked with applying rules, maintaining fairness, and ensuring athlete safety. However, sport officials experience anxiety, burnout, and non-accidental violence, with the incidence of these events increasing worldwide. This has led to rising attrition rates among sport officials, with many sport organizations concerned for their operational capacity. The effects of anxiety, burnout, and non-accidental violence might contribute to or be indicative of sport officials' negative mental health outcomes. To develop a clear understanding of how sport officials' mental health is affected by their occupation, it is necessary to identify the mental health outcomes and predictors they experience, and to what extent. The purpose of this scoping review was to identify and examine the empirical research and policy documents surrounding sport officials' mental health. Method: One thousand, two hundred six articles were identified across four databases: PubMed, Web of Science, SportDiscus, and PsycINFO. Next, a policy search was conducted on the respective international governing body websites from English-speaking countries for the 60 included sports. Following screening, 18 studies and one policy document met the inclusion criteria for exploring sport officials' mental health. Results: Participants (N = 7,941) in the studies were mainly European male soccer and basketball referees. Most studies utilized quantitative inquiry (n = 15) rather than qualitative methods (n = 2) or framework development (n = 1). The research demonstrated that sport officials frequently experienced negative mental health outcomes and predictors including anxiety, depression, burnout, lower mental health literacy, and high levels of stigmatization towards mental health. Discussion: These outcomes were influenced by gender/sex, age, and experience. There is a need to explore personal and environmental (including occupational) factors that cause or contribute to sport officials' mental health symptoms and disorders.

7.
Int J Syst Evol Microbiol ; 63(Pt 6): 2146-2154, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23104363

RESUMO

Corynebacterium propinquum is a Gram-positive rod occasionally recovered from clinical infections which, according to 16S rRNA gene sequencing, is most closely related (>99% sequence similarity) to Corynebacterium pseudodiphtheriticum. The two species are very similar biochemically, commonly differentiated by a single test, the detection of urease, where strains of C. propinquum are described as being urease-non-producing and strains of C. pseudodiphtheriticum are described as urease-producing. In this study, historical and contemporary strains of C. propinquum and C. pseudodiphtheriticum from this laboratory were definitively characterized, which included use of rpoB sequencing. Urease-producing strains of C. propinquum as well as typical urease-non-producing isolates were identified after rpoB sequencing, with six of these being originally identified as C. pseudodiphtheriticum. Based on these observations, we propose emendation of the description of C. propinquum to include strains which produce urease. MALDI-TOF analysis may be a useful tool to differentiate these taxa. Existing commercial databases should be updated to include urease-positive strains of C. propinquum.


Assuntos
Corynebacterium/classificação , Urease/biossíntese , Corynebacterium/enzimologia , DNA Bacteriano/genética , Genes Bacterianos , Dados de Sequência Molecular , Fenótipo , RNA Ribossômico 16S/genética , Especificidade da Espécie , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
8.
Med Phys ; 39(1): 132-42, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22225282

RESUMO

PURPOSE: X-ray digital subtraction angiography (DSA) is widely used for vascular imaging. However, the need to subtract a mask image can result in motion artifacts and compromised image quality. The current interest in energy-resolving photon-counting (EPC) detectors offers the promise of eliminating motion artifacts and other advanced applications using a single exposure. The authors describe a method of assessing the iodine signal-to-noise ratio (SNR) that may be achieved with energy-resolved angiography (ERA) to enable a direct comparison with other approaches including DSA and dual-energy angiography for the same patient exposure. METHODS: A linearized noise-propagation approach, combined with linear expressions of dual-energy and energy-resolved imaging, is used to describe the iodine SNR. The results were validated by a Monte Carlo calculation for all three approaches and compared visually for dual-energy and DSA imaging using a simple angiographic phantom with a CsI-based flat-panel detector. RESULTS: The linearized SNR calculations show excellent agreement with Monte Carlo results. While dual-energy methods require an increased tube heat load of 2× to 4× compared to DSA, and photon-counting detectors are not yet ready for angiographic imaging, the available iodine SNR for both methods as tested is within 10% of that of conventional DSA for the same patient exposure over a wide range of patient thicknesses and iodine concentrations. CONCLUSIONS: While the energy-based methods are not necessarily optimized and further improvements are likely, the linearized noise-propagation analysis provides the theoretical framework of a level playing field for optimization studies and comparison with conventional DSA. It is concluded that both dual-energy and photon-counting approaches have the potential to provide similar angiographic image quality to DSA.


Assuntos
Algoritmos , Angiografia Digital/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Med Phys ; 39(5): 2478-90, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22559618

RESUMO

PURPOSE: This study investigates the fundamental signal and noise performance limitations imposed by the stochastic nature of x-ray interactions in selected photoconductor materials, such as Si, a-Se, CdZnTe, HgI(2), PbI(2), PbO, and TlBr, for x-ray spectra typically used in mammography. METHODS: It is shown how Monte Carlo simulations can be combined with a cascaded model to determine the absorbed energy distribution for each combination of photoconductor and x-ray spectrum. The model is used to determine the quantum efficiency, mean energy absorption per interaction, Swank noise factor, secondary quantum noise, and zero-frequency detective quantum efficiency (DQE). RESULTS: The quantum efficiency of materials with higher atomic number and density demonstrates a larger dependence on convertor thickness than those with lower atomic number and density with the exception of a-Se. The mean deposited energy increases with increasing average energy of the incident x-ray spectrum. HgI(2), PbI(2), and CdZnTe demonstrate the largest increase in deposited energy with increasing mass loading and a-Se and Si the smallest. The best DQE performances are achieved with PbO and TlBr. For mass loading greater than 100 mg cm(-2), a-Se, HgI(2), and PbI(2) provide similar DQE values to PbO and TlBr. CONCLUSIONS: The quantum absorption efficiency, average deposited energy per interacting x-ray, Swank noise factor, and detective quantum efficiency are tabulated by means of graphs which may help with the design and selection of materials for photoconductor-based mammography detectors. Neglecting the electrical characteristics of photoconductor materials and taking into account only x-ray interactions, it is concluded that PbO shows the strongest signal-to-noise ratio performance of the materials investigated in this study.


Assuntos
Luz , Mamografia/métodos , Absorção , Método de Monte Carlo , Análise Espectral
10.
J Vasc Interv Radiol ; 23(8): 1089-93, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22840807

RESUMO

Most tunneled catheters can be easily removed after the retention cuff is dissected. Occasionally, these catheters can become resistant to removal even after application of potentially hazardous forceful traction. In addition, an infected catheter may cause life-threatening septicemia. Several methods have been described for their extraction, some of which may be available only in tertiary-care facilities. The present report describes the successful extraction of five such "stuck" catheters by using a recently described technique of endoluminal dilation. The technique appears safe and straightforward and can be performed in any interventional suite while allowing preservation of venous access.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Remoção de Dispositivo/métodos , Procedimentos Endovasculares , Diálise Renal , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Venoso Central/instrumentação , Remoção de Dispositivo/instrumentação , Dilatação , Procedimentos Endovasculares/instrumentação , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ontário , Radiografia Intervencionista , Resultado do Tratamento
11.
J Comput Assist Tomogr ; 36(5): 616-22, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22992615

RESUMO

Dual-energy computed tomography (CT) enables 3-dimensional,noninvasive, and nondestructive imaging with material separation. Dual-energy CT is generally used to segment hydrated tissues within the clinical context. We apply dual-energy CT to an ancient Egyptian mummy and present several techniques designed to separate bone from desiccated tissue and resin. Automated and semiautomated dual-energy CT techniques are compared to manual segmentation and thresholding-based techniques. Semiautomated techniques enable substantial reductions in operator time compared to manual segmentation.


Assuntos
Imageamento Tridimensional/métodos , Múmias , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Egito , Feminino , Humanos
12.
Med Phys ; 49(11): 6885-6902, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36086878

RESUMO

BACKGROUND: X-ray coronary angiography is a sub-optimal vascular imaging technique because it cannot suppress un-enhanced anatomy that may obscure the visualization of coronary artery disease. PURPOSE: The purpose of this paper is to evaluate the theoretical image quality of energy-resolved x-ray angiography (ERA) implemented with spectroscopic x-ray detectors (SXDs), which may overcome limitations of x-ray coronary angiography. METHODS: We modeled the large-area signal-difference-to-noise (SDNR) of contrast-enhanced vasculature in ERA images and compared with that of digital-subtraction angiography (DSA), which served as a gold standard vascular imaging technique. To this end, we used calibrated numerical models of the response of cadmium telluride SXDs including the effects of charge sharing, electronic noise, and energy thresholding. Our models assumed zero scatter, no pulse pile up and small signals such that image contrast is approximately linear in the area density of contrast agents. For DSA, we similarly modeled x-ray detection by cesium iodide energy-integrating detectors using validated numerical models. For ERA, we investigated iodine and gadolinium (Gd) contrast agents, two-material and three-material decompositions, analog charge summing for charge sharing correction, and optimized image quality with respect to the tube voltage and energy thresholds assuming cadmium telluride SXDs with three energy bins. RESULTS: Our analysis reveals that a three-material decomposition using iodine contrast agents will require x-ray exposures that are approximately 400 times those of DSA to achieve the same SDNR as DSA in coronary applications, and is therefore not feasible in a clinical setting. However, three-material decompositions with Gd contrast agents have the potential to provide SDNR that is ∼45% of that of DSA for matched patient air kerma. For two-material decompositions that suppress soft-tissue, ERA has the potential to produce images with SDNR that is 50%-75% of that of DSA for matched patient air kermas but lower levels of tube loading. Achieving these SDNR levels will require the use of analog charge summing for charge sharing correction, which increased SDNR by up to a factor of 1.7 depending on the contrast agent and whether or not a two-material or three-material decomposition was assumed. CONCLUSIONS: We conclude that three-material ERA implemented with Gd contrast agents and two-material ERA implemented with either iodine or Gd contrast agents, should be investigated as alternatives to DSA in situations where motion artifacts preclude the use of DSA, such as in coronary imaging.


Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Humanos , Eletrônica
13.
J Med Imaging (Bellingham) ; 9(Suppl 1): 012205, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35309720

RESUMO

Purpose: For 50 years now, SPIE Medical Imaging (MI) conferences have been the premier forum for disseminating and sharing new ideas, technologies, and concepts on the physics of MI. Approach: Our overarching objective is to demonstrate and highlight the major trajectories of imaging physics and how they are informed by the community and science present and presented at SPIE MI conferences from its inception to now. Results: These contributions range from the development of image science, image quality metrology, and image reconstruction to digital x-ray detectors that have revolutionized MI modalities including radiography, mammography, fluoroscopy, tomosynthesis, and computed tomography (CT). Recent advances in detector technology such as photon-counting detectors continue to enable new capabilities in MI. Conclusion: As we celebrate the past 50 years, we are also excited about what the next 50 years of SPIE MI will bring to the physics of MI.

14.
Med Phys ; 37(12): 6205-11, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21302777

RESUMO

PURPOSE: Energy-resolved x-ray imaging has the potential to improve contrast-to-noise ratio by measuring the energy of each interacting photon and applying optimal weighting factors. The success of energy-resolving photon-counting (EPC) detectors relies on the ability of an x-ray detector to accurately measure the energy of each interacting photon. However, the escape of characteristic emissions and Compton scatter degrades spectral information. This article makes the theoretical connection between accuracy and imprecision in energy measurements with the x-ray Swank factor for a-Se, Si, CdZnTe, and HgI2-based detectors. METHODS: For a detector that implements adaptive binning to sum all elements in which x-ray energy is deposited for a single interaction, energy imprecision is shown to depend on the Swank factor for a large element with x rays incident at the center. The response function for each converter material is determined using Monte Carlo methods and used to determine energy accuracy, Swank factor, and relative energy imprecision in photon-energy measurements. RESULTS: For each material, at energies below the respective K edges, accuracy is close to unity and imprecision is only a few percent. Above the K-edge energies, characteristic emission results in a drop in accuracy and precision that depends on escape probability. In Si, and to some extent a-Se, Compton-scatter escape also degrades energy precision with increasing energy. The influence of converter thickness on energy accuracy and imprecision is modest for low-Z materials but becomes important when using high-Z materials at energies greater than the K-edge energies. CONCLUSIONS: Accuracy and precision in energy measurements by EPC detectors are determined largely by the energy-dependent x-ray Swank factor. Modest decreases in the Swank factor (5%-15%) result in large increases in relative imprecision (30%-40%).


Assuntos
Fótons , Tomografia Computadorizada por Raios X/métodos , Método de Monte Carlo
15.
Med Phys ; 47(7): 2881-2901, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32239517

RESUMO

PURPOSE: We present a new framework for theoretical analysis of the noise power spectrum (NPS) of photon-counting x-ray detectors, including simple photon-counting detectors (SPCDs) and spectroscopic x-ray detectors (SXDs), the latter of which use multiple energy thresholds to discriminate photon energies. METHODS: We show that the NPS of SPCDs and SXDs, including spatio-energetic noise correlations, is determined by the joint probability density function (PDF) of deposited photon energies, which describes the probability of recording two photons of two different energies in two different elements following a single-photon interaction. We present an analytic expression for this joint PDF and calculate the presampling and digital NPS of CdTe SPCDs and SXDs. We calibrate our charge sharing model using the energy response of a cadmium zinc telluride (CZT) spectroscopic x-ray detector and compare theoretical results with Monte Carlo simulations. RESULTS: Our analysis shows that charge sharing increases pixel signal-to-noise ratio (SNR), but degrades the zero-frequency signal-to-noise performance of SPCDs and SXDs. In all cases considered, this degradation was greater than 10%. Comparing the presampling NPS with the sampled NPS showed that degradation in zero-frequency performance is due to zero-frequency noise aliasing induced by charge sharing. CONCLUSIONS: Noise performance, including spatial and energy correlations between elements and energy bins, are described by the joint PDF of deposited energies which provides a method of determining the photon-counting NPS, including noise-aliasing effects and spatio-energetic effects in spectral imaging. Our approach enables separating noise due to x-ray interactions from that associated with sampling, consistent with cascaded systems analysis of energy-integrating systems. Our methods can be incorporated into task-based assessment of image quality for the design and optimization of spectroscopic x-ray detectors.


Assuntos
Compostos de Cádmio , Pontos Quânticos , Fótons , Telúrio , Raios X
16.
Med Phys ; 45(5): 1926-1941, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29526029

RESUMO

PURPOSE: Single-photon-counting (SPC) and spectroscopic x-ray detectors are under development in academic and industry laboratories for medical imaging applications. The spatial resolution of SPC and spectroscopic x-ray detectors is an important design criterion. The purpose of this article was to extend the cascaded systems approach to include a description of the spatial resolution of SPC and spectroscopic x-ray imaging detectors. METHODS: A cascaded systems approach was used to model reabsorption of characteristic x rays, Coulomb repulsion, and diffusion in SPC and spectroscopic x-ray detectors. In addition to reabsorption, diffusion, and Coulomb repulsion, the model accounted for x-ray conversion to electron-hole (e-h) pairs, integration of e-h pairs in detector elements, electronic noise, and energy thresholding. The probability density function (PDF) describing the number of e-h pairs was propagated through each stage of the model and was used to derive new theoretical expressions for the large-area gain and modulation transfer function (MTF) of CdTe SPC x-ray detectors, and the energy bin sensitivity functions and MTFs of CdTe spectroscopic detectors. Theoretical predictions were compared with the results of MATLAB-based Monte Carlo (MC) simulations and published data. Comparisons were also made with the MTF of energy-integrating systems. RESULTS: Under general radiographic conditions, reabsorption, diffusion, and Coulomb repulsion together artificially inflate count rates by 20% to 50%. For thicker converters (e.g. 1000 µm) and larger detector elements (e.g. 500 µm pixel pitch) these processes result in modest inflation (i.e. ∼10%) in apparent count rates. Our theoretical and MC analyses predict that SPC MTFs will be degraded relative to those of energy-integrating systems for fluoroscopic, general radiographic, and CT imaging conditions. In most cases, this degradation is modest (i.e., ∼10% at the Nyquist frequency). However, for thicker converters, the SPC MTF can be degraded by up to 25% at the Nyquist frequency relative to EI systems. Additionally, unlike EI systems, the MTF of spectroscopic systems is strongly dependent on photon energy, which results in energy-bin-dependent spatial resolution in spectroscopic systems. CONCLUSIONS: The PDF-transfer approach to modeling signal transfer through SPC and spectroscopic x-ray imaging systems provides a framework for understanding system performance. Application of this approach demonstrated that charge sharing artificially inflates the SPC image signal and degrades the MTF of SPC and spectroscopic systems relative to energy-integrating systems. These results further motivate the need for anticharge-sharing circuits to mitigate the effects of charge sharing on SPC and spectroscopic x-ray image quality.


Assuntos
Compostos de Cádmio , Fótons , Radiografia/instrumentação , Telúrio , Método de Monte Carlo , Raios X
18.
Med Phys ; 45(2): e32-e39, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29220101

RESUMO

PURPOSE: The AAPM Task Group 162 aimed to provide a standardized approach for the assessment of image quality in planar imaging systems. This report offers a description of the approach as well as the details of the resultant software bundle to measure detective quantum efficiency (DQE) as well as its basis components and derivatives. METHODS: The methodology and the associated software include the characterization of the noise power spectrum (NPS) from planar images acquired under specific acquisition conditions, modulation transfer function (MTF) using an edge test object, the DQE, and effective DQE (eDQE). First, a methodological framework is provided to highlight the theoretical basis of the work. Then, a step-by-step guide is included to assist in proper execution of each component of the code. Lastly, an evaluation of the method is included to validate its accuracy against model-based and experimental data. RESULTS: The code was built using a Macintosh OSX operating system. The software package contains all the source codes to permit an experienced user to build the suite on a Linux or other *nix type system. The package further includes manuals and sample images and scripts to demonstrate use of the software for new users. The results of the code are in close alignment with theoretical expectations and published results of experimental data. CONCLUSIONS: The methodology and the software package offered in AAPM TG162 can be used as baseline for characterization of inherent image quality attributes of planar imaging systems.


Assuntos
Intensificação de Imagem Radiográfica , Software , Processamento de Imagem Assistida por Computador , Controle de Qualidade
19.
Med Biol Eng Comput ; 45(7): 689-93, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17611788

RESUMO

An expert system is described for the differential diagnosis of vertical deviation strabismus (squint) from measurements taken in the standard prism cover test. The deviations are represented as optical powers in prism dioptres using the graphic representation of strabismus (after Jampolsky). The expert is implemented in MatLab (Mathworks Ltd., Cambridge, UK) both as a stand-alone program on a PC and as a web application available over the Internet (see http://www.strabnet.com ). In trial and clinical datasets a diagnostic accuracy of 100% was achieved.


Assuntos
Sistemas Inteligentes , Estrabismo/diagnóstico , Diagnóstico por Computador/instrumentação , Diagnóstico por Computador/métodos , Diagnóstico Diferencial , Desenho de Equipamento , Humanos , Software
20.
IEEE Trans Biomed Eng ; 64(1): 173-183, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27093307

RESUMO

GOAL: We investigate the signal and noise performance of an x-ray microtomography system that incorporates a complementary metal-oxide-semiconductor flat-panel detector as a projection image receptor. METHODS: Signal and noise performance is analyzed in the Fourier domain using modulation-transfer function (MTF), noise-power spectrum (NPS), and noise-equivalent number of quanta (NEQ) with respect to magnification and different convolution kernels for image reconstruction. RESULTS: Higher magnification provides lower NPS, and thus, higher NEQ performance in the transaxial planes from microtomography. A window function capable of smoothing the ramp filter edge to below one-half of the Nyquist limit results in better performance in terms of NPS and NEQ. The characteristics of convolution kernels do not affect signal and noise performance in longitudinal planes; hence, MTF performance mainly dominates the NEQ performance. The signal and noise performances investigated in this study are demonstrated with images obtained from the contrast phantom and postmortem mouse. CONCLUSION: The results of our study could be helpful in developing x-ray microtomography systems based on flat-panel detectors.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído , Microtomografia por Raio-X/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Análise de Fourier , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA