Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-35627512

RESUMO

In patients with advanced heart failure (HF), left ventricular assist devices (LVADs) have demonstrated to be effective in improving the quality of life and reducing further hospitalizations. Although uncommon, LVAD outflow graft obstruction (OGO) is a potentially life-threatening complication and percutaneous treatment has been proposed as a standard intervention strategy in such cases. We report the case of a 69 year old man admitted due to LVAD failure causing unstable HF. Past medical history included percutaneous intervention on the outflow graft with stent implantation one year before. The patient was under chronic treatment with vitamin K antagonists (VKA). Emergent percutaneous angiography was performed, showing recurrent OGO due to thrombosis located at a kinking site, distally to the previously treated segment. Using distal anchoring technique, a balloon-expandable 10 × 79 mm endoprosthesis (GORE® Viabahn® VBX) was effectively positioned and post-dilated. Final angiography confirmed the patency of the stent implanted one-year before. Despite the procedure succeeding in restoring LVAD function, the patient died due to septic shock ten days after. Our case suggests that recurrent OGO can be effectively treated with percutaneous redo and that long-term stent patency can be achieved with a standard antithrombotic treatment, despite further thrombotic events in other segments of the graft are still possible (especially at the kinking site). Moreover, other noncardiac conditions as infective complications, can dramatically impact the clinical course and lead to unfavorable outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Idoso , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Qualidade de Vida
2.
Artigo em Inglês | MEDLINE | ID: mdl-35206629

RESUMO

Left ventricular assist device (LVAD) obstruction can be a dramatic and life-threatening complication in patients with advanced heart failure (HF). Despite surgical redo is often required in these patients, it is associated with a high risk of periprocedural negative outcome. We report the case of a 68-year-old male with a thrombotic stenosis of the LVAD proximal outflow-graft. Following Heart Team debate, a percutaneous intervention was planned during veno-arterial Extra Corporeal Membrane Oxygenation (ECMO) assistance. To achieve the needed catheter support, we used the "distal balloon anchoring technique" through the outflow-graft and managed to implant a covered stent, rapidly restoring the flow through the LVAD. The patient was discharged without further complications. Our case shows that, in selected cases, percutaneous treatment of LVAD obstructions can be feasible, especially using advanced techniques derived from the experiences in coronary interventions and under ECMO assistance. More cases and prospective studies are mostly needed to explore long-term patency of the LVADs and clinical outcomes in these high-risk patients.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Idoso , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Estudos Prospectivos
3.
Eur Heart J Case Rep ; 5(2): ytaa513, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33598609

RESUMO

BACKGROUND: Pheochromocytoma is a rare catecholamine-producing tumour that classically displays clinical manifestations related to alpha-adrenergic stimulation, including paroxysmal or sustained hypertension. However, it may occasionally be complicated by life-threatening crisis, leading to refractory acute heart dysfunction in the most severe cases. CASE SUMMARY: A 28-year-old woman was admitted to intensive care unit due to hypertensive crisis causing pulmonary oedema, Takotsubo cardiomyopathy, and metabolic acidosis. Due to cardiogenic shock, she required venoarterial extracorporeal membrane oxygenation and IMPELLA implantation. A computed tomography scan revealed a 5 cm tumour of the left adrenal gland compatible with pheochromocytoma The clinical course was complicated by acute kidney injury requiring renal replacement therapy and posterior reversible encephalopathy syndrome (PRES). Pharmacological treatment with alpha lityc agents (including urapidil, dexmedetomidine, and doxazosin at maximum daily dose) and beta blockers, together with left videolaparoscopic adrenalectomy, led to progressive blood pressure control and resolution of the neurological symptoms. DISCUSSION: Pheochromocytoma crisis turned into a potential catastrophic scenario, characterized by refractory cardiogenic shock requiring circulatory supportive devices and PRES. Alpha-antagonists and beta-blockers were the gold standard pharmacological treatment. A multidisciplinary decision-algorithm was necessary to successfully manage this complex clinical setting.

4.
J Clin Monit Comput ; 18(2): 81-7, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15362269

RESUMO

Cardiac output (CO) is a parameter usually requested to assess hemo dynamic status of patient and efficacy of therapy especially in critically ill patients. This paper, in line with other research activities and new market availability, intends to correlate a parameter derived from data already acquired in standard patient monitoring (systemic arterial pressure--Pas) in order to identify CO trends and, more generally, to obtain information on the efficiency of cardiovascular system of the patient in examination. Attention has been focussed on patients undergoing abdominal aneurysm aortic (AAA) surgery with combined anaesthesia (epidural and light general). Awake correlation was found between maximum value of Pas time derivative, max (dPas/dt), and CO measured with thermodilution method on 56 measurements on 10 patients. To evaluate further diagnostic capability of max (dPas/dt), we compare its trend with other parameters but no statistical significant results have been obtained. Therefore the target parameter can be profitably used in the examined patients to monitor CO trend and, in correlation with other parameters, as a sign of efficiency of the cardio circulatory system.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Monitores de Pressão Arterial , Débito Cardíaco , Processamento de Sinais Assistido por Computador , Idoso , Idoso de 80 Anos ou mais , Anestesia Epidural , Anestesia Geral , Desenho de Equipamento , Feminino , Humanos , Masculino , Sensibilidade e Especificidade