Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Ann Vasc Surg ; 102: 133-139, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38408393

RESUMO

BACKGROUND: Carotid near-occlusion (CNO) represents an anatomical-functional condition characterized by severe (more than 90%) internal carotid artery stenosis which can lead to a distal lumen diameter greater or less than 2 mm. CNO can be divided into a less severe subgroup (without lumen full collapse: diameter >2 mm) and a more severe subgroup (with lumen full collapse: diameter <2 mm). The decision for revascularization is still highly debated in Literature. The aim of the present multicenter retrospective study is to analyze the incidence of perioperative (30 days) and follow-up complications in 2 groups of patients with or without distal internal carotid lumen full collapse. METHODS: Between January 2011 and March 2023, in 5 Vascular Surgery Units, 67 patients (49 male, 73% and 18 females, 27%) with CNO underwent carotid endarterectomy: 28 (41.7%) with lumen diameter <2 mm and 39 (58.3%) with diameter >2 mm. 19 patients were symptomatic and 48 asymptomatic. The outcomes considered for comparative analysis were: perioperative neurological and cardiac complications, carotid restenosis or occlusion at follow-up. Both groups were homogeneous in terms of risk factors, morphological features and pharmacological treatments. RESULTS: In the group with lumen <2 mm, 3 perioperative major events (10.7%) occurred (1 ischemic stroke, 1 hemorrhagic stroke, 1 myocardial infarction) and 2 (7.1%) at follow-up (average 11 ± 14.5 months; 1 asymptomatic carotid occlusion, 1 hemodynamic restenosis treated with stenting). No event was recorded in the group with lumen >2 mm. CONCLUSIONS: According to our results CNO patients show different complication risk according to the presence or not of distal lumen collapse. The later seems to play a significant role in perioperative and follow-up complication rate. These results therefore support a surgical treatment only in patients with CNO without lumen full collapse.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Acidente Vascular Cerebral , Feminino , Humanos , Masculino , Estudos Retrospectivos , Tratamento Conservador/efeitos adversos , Resultado do Tratamento , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Artérias Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Endarterectomia das Carótidas/métodos , Fatores de Risco , Constrição Patológica/etiologia , Acidente Vascular Cerebral/complicações , Stents/efeitos adversos
2.
Anal Chem ; 93(20): 7388-7393, 2021 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-33973781

RESUMO

The availability of portable analytical devices for on-site monitoring and rapid detection of analytes of forensic, environmental, and clinical interest is vital. We report the development of a portable device for the detection of biochemiluminescence relying on silicon photomultiplier (SiPM) technology, called LuminoSiPM, which includes a 3D printed sample holder that can be adapted for both liquid samples and paper-based biosensing. We performed a comparison of analytical performance in terms of detectability with a benchtop luminometer, a portable cooled charge-coupled device (CCD sensor), and smartphone-integrated complementary metal oxide semiconductor (CMOS) sensors. As model systems, we used two luciferase/luciferin systems emitting at different wavelengths using purified protein solutions: the green-emitting P. pyralis mutant Ppy-GR-TS (λmax 550 nm) and the blue-emitting NanoLuc (λmax 460 nm). A limit of detection of 9 femtomoles was obtained for NanoLuc luciferase, about 2 and 3 orders of magnitude lower than that obtained with the portable CCD camera and with the smartphone, respectively. A proof-of-principle forensic application of LuminoSiPM is provided, exploiting an origami chemiluminescent paper-based sensor for acetylcholinesterase inhibitors, showing high potential for this portable low-cost device for on-site applications with adequate sensitivity for detecting low light intensities in critical fields.


Assuntos
Técnicas Biossensoriais , Luminescência , Luz , Luciferases , Smartphone
3.
Anal Bioanal Chem ; 413(13): 3399-3410, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33755770

RESUMO

Hemp cultivation is living a period of renewed interest worldwide after long years of opposition and abandonment. The European Union (EU) allows and subsidizes the growing of fiber and oilseed cultivars of Cannabis sativa L. with respect to the THC content limit of 0.2%. The EU method for the quantitative determination of Δ9-tetrahydrocannabinol (THC) content in hemp varieties provides to apply a tolerance of 0.03 g of THC per 100 g of sample concerning compliance assessment to that limit. However, the method does not report any precision data, especially useful as a function of THC content to evaluate measurement uncertainty and therefore to establish the conformity of hemp at different THC legal limits. Measurement uncertainty of the method by both bottom-up and top-down approach, besides repeatability and reproducibility, was investigated and estimated in the THC concentration range 0.2-1.0%, which includes the different legal limits set out for hemp around the world. We proposed Decision Rules for conformity of hemp showing that a non-compliant declaration beyond reasonable doubt should be stated when the THC content, as a mean result on a duplicate analysis, exceeds the limit by at least 11-15%, depending on THC limit. We highlighted other issues concerning practical aspects of hemp analysis, from sampling to evaluation of results, as well as the need to carry out collaborative studies on the EU method.


Assuntos
Cannabis/química , Dronabinol/análise , Incerteza , União Europeia , Reprodutibilidade dos Testes
4.
Anal Bioanal Chem ; 411(19): 4937-4949, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30972468

RESUMO

Cell-based assays utilizing reporter gene technology have been widely exploited for biosensing, as they provide useful information about the bioavailability and cell toxicity of target analytes. The long assay time due to gene transcription and translation is one of the main drawbacks of cell biosensors. We report the development of two yeast biosensors stably expressing human estrogen receptors α and ß and employing NanoLuc as the reporter protein to upgrade the widely used yeast estrogen screening (YES) assays. A viability control strain was also developed based on a chimeric green-emitting luciferase, PLG2, expressed for the first time in Saccharomycescerevisiae. Thanks to their brightness, NanoLuc and PLG2 provided excellent sensitivity, enabling the implementation of these biosensors into low-cost smartphone-based devices. The developed biosensors had a rapid (1 h) response and reported on (anti)estrogenic activity via human estrogen receptors α and ß as well as general sample toxicity. Under optimized conditions, we obtained LODs of 7.1 ± 0.4 nM and 0.38 ± 0.08 nM for E2 with nanoYESα and nanoYESß, respectively. As a proof of concept, we analyzed real samples from plants showing significant estrogenic activity or known to contain significant amounts of phytoestrogens. Graphical abstract.


Assuntos
Técnicas Biossensoriais , Disruptores Endócrinos/análise , Medições Luminescentes/métodos , Nanotecnologia , Saccharomyces cerevisiae/metabolismo , Smartphone , Genes Reporter , Limite de Detecção , Luciferases/genética , Medicago sativa/química , Extratos Vegetais/química , Reprodutibilidade dos Testes , Saccharomyces cerevisiae/genética , Glycine max/química , Poluentes Químicos da Água/análise
5.
Ann Vasc Surg ; 61: 471.e1-471.e2, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31394213

RESUMO

Pancreaticoduodenal artery aneurysm (PDA) is a rare visceral aneurysm and represents 1.5% of all the visceral arterial aneurysms. An 81-year-old man was admitted with acute abdominal pain. He suffered 2 previous episodes of pancreatitis and underwent abdominal aortic aneurysm repair 11 years before. The computed tomography scan revealed a 92-mm aneurysm of inferior PDA artery with prerupture signs associated with the celiac trunk obstruction. The patient underwent a selective catheterization and embolization of superior PDA artery with coils, inferior PDA artery with 12-mm Amplatzer, and aneurysm sac embolization by Onyx and coils. The postoperative course was uneventful and the patient was discharged on the fourth postoperative day. Celiac trunk stenosis could be one of the possible etiology but atherosclerosis and pancreatitis are the 2 most common risk factors. Treatment of choice is yet to be established and it has to be properly defined "case by case"; surgery, endovascular embolization, or percutaneous thrombin injection are valuable approaches.


Assuntos
Aneurisma/etiologia , Aneurisma da Aorta Abdominal/cirurgia , Artéria Celíaca , Duodeno/irrigação sanguínea , Síndrome do Ligamento Arqueado Mediano/complicações , Pâncreas/irrigação sanguínea , Pancreatite Crônica/complicações , Idoso de 80 Anos ou mais , Aneurisma/diagnóstico por imagem , Aneurisma/terapia , Artéria Celíaca/diagnóstico por imagem , Artéria Celíaca/fisiopatologia , Embolização Terapêutica/instrumentação , Humanos , Masculino , Síndrome do Ligamento Arqueado Mediano/diagnóstico por imagem , Síndrome do Ligamento Arqueado Mediano/fisiopatologia , Síndrome do Ligamento Arqueado Mediano/terapia , Pancreatite Crônica/diagnóstico , Fatores de Risco , Resultado do Tratamento
6.
Anal Bioanal Chem ; 410(4): 1237-1246, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28965124

RESUMO

The presence of chemicals with estrogenic activity in surface, groundwater, and drinking water poses serious concerns for potential threats to human health and aquatic life. At present, no sensitive portable devices are available for the rapid monitoring of such contamination. Here, we propose a cell-based mobile platform that exploits a newly developed bioluminescent yeast-estrogen screen (nanoYES) and a low-cost compact camera as light detector. Saccharomyces cerevisiae cells were genetically engineered with a yeast codon-optimized variant of NanoLuc luciferase (yNLucP) under the regulation of human estrogen receptor α activation. Ready-to-use 3D-printed cartridges with immobilized cells were prepared by optimizing a new procedure that enables to produce alginate slices with good reproducibility. A portable device was obtained exploiting a compact camera and wireless connectivity enabling a rapid and quantitative evaluation (1-h incubation at room temperature) of total estrogenic activity in small sample volumes (50 µL) with a LOD of 0.08 nM for 17ß-estradiol. The developed portable analytical platform was applied for the evaluation of water samples spiked with different chemicals known to have estrogen-like activity. Thanks to the high sensitivity of the newly developed yeast biosensor and the possibility to wireless connect the camera with any smartphone model, the developed configuration is more versatile than previously reported smartphone-based devices, and could find application for on-site analysis of endocrine disruptors. Graphical abstract Wireless effect-based detection of endocrine-disrupting chemicals with nanoYES platform.


Assuntos
Técnicas Biossensoriais , Disruptores Endócrinos/análise , Estrogênios/análise , Fotografação/instrumentação , Saccharomyces cerevisiae/metabolismo , Poluentes Químicos da Água/análise , Tecnologia sem Fio , Luminescência , Impressão Tridimensional
7.
Anal Bioanal Chem ; 405(2-3): 1035-45, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23010847

RESUMO

Bioassays represent promising complementary techniques to conventional analytical approaches used in doping analysis to detect illicit drugs like anabolic-androgenic steroids (AAS). The fact that all AAS share a common mechanism of action via the human androgen receptor (hAR) enables the use of bioassays, relying on the activation of hAR as antidoping screening tools. Previously, we developed a dual-color bioreporter based on yeast cells engineered to express hAR and androgen response elements driving the expression of the bioluminescent (BL) reporter protein Photinus pyralis luciferase. A second reporter protein, the red-emitting luciferase PpyRE8, was introduced in the bioreporter as internal viability control. Here, we report the first forensic application of a straightforward, accurate, and cost-effective bioassay, relying on spectral resolution of the two BL signals, in 96-microwell format. The bioreporter responds to dihydrotestosterone as reference androgen in a concentration-dependent manner from 0.08 to 1,000 nM with intra- and inter-assay variation coefficients of 11.4 % and 13.1 %, respectively. We also demonstrated the suitability of this dual-color bioreporter to assess (anti)-androgenic activity of pure AAS, mixtures of AAS, and other illicit drugs provided by the Scientific Police. Significant anti-androgenic activity was observed in samples labeled as marijuana and hashish, containing Δ(9)-tetrahydrocannabinol as major constituent.


Assuntos
Antagonistas de Androgênios/análise , Androgênios/análise , Técnicas Biossensoriais/métodos , Medicina Legal/métodos , Drogas Ilícitas/análise , Medições Luminescentes/métodos , Antagonistas de Androgênios/urina , Androgênios/urina , Genes Reporter , Humanos , Drogas Ilícitas/urina , Luciferases/análise , Luciferases/urina , Masculino , Receptores Androgênicos/genética , Receptores Androgênicos/metabolismo , Esteroides/análise , Esteroides/urina
8.
Biosensors (Basel) ; 13(4)2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37185526

RESUMO

Adenosine triphosphate (ATP) determination has been used for many decades to assess microbial contamination for hygiene monitoring in different locations and workplace environments. Highly sophisticated methods have been reported, yet commercially available kits rely on a luciferase-luciferin system and require storage and shipping at controlled temperatures (+4 or -20 °C). The applicability of these systems is limited by the need for a secure cold chain, which is not always applicable, especially in remote areas or low-resource settings. In this scenario, easy-to-handle and portable sensors would be highly valuable. Prompted by this need, we developed a bioluminescence paper biosensor for ATP monitoring in which a new luciferase mutant was combined with a metal-organic framework (MOF); i.e., zeolitic imidazolate framework-8 (ZIF-8). A paper biosensor was developed, ZIF-8@Luc paper sensor, and interfaced with different portable light detectors, including a silicon photomultiplier (SiPM) and smartphones. The use of ZIF-8 not only provided a five-fold increase in the bioluminescence signal, but also significantly improved the stability of the sensor, both at +4 and +28 °C. The ATP content in complex biological matrices was analyzed with the ZIF-8@Luc paper sensor, enabling detection down to 7 × 10-12 moles of ATP and 8 × 10-13 moles in bacterial lysates and urine samples, respectively. The ZIF-8@Luc sensor could, therefore, be applied in many fields in which ATP monitoring is required such as the control of microbial contamination.


Assuntos
Técnicas Biossensoriais , Estruturas Metalorgânicas , Toupeiras , Zeolitas , Animais , Trifosfato de Adenosina , Luciferases , Técnicas Biossensoriais/métodos
9.
Anal Chim Acta ; 1200: 339583, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35256132

RESUMO

Bioluminescence, that is the emission of light in living organisms, has been extensively explored and applied for diverse bioanalytical applications, spanning from molecular imaging to biosensing. The unprecedented technological evolution of portable light detectors opened new possibilities to implement bioluminescence detection into miniaturized devices. We are witnessing a number of applications, including DNA sequencing, reporter gene assays, DNA amplification for point-of care and point-of need analyses relying on BL. Several photon detectors are currently available for measuring low light emission, such as photomultiplier tubes (PMT), charge-coupled devices (CCD), complementary metal oxide semiconductors (CMOS), single photon avalanche diodes (SPADs), silicon photomultipliers (SiPMs) and smartphone-integrated CMOS. Each technology has pros and cons and several issues, such as temperature dependence of the instrumental specific noise, the power supply, imaging capability and ease of integration, should be considered in the selection of the most appropriate detector for the selected BL application. These issues will be critically discussed from the perspective of the analytical chemist together with relevant examples from the literature with the goal of helping the reader in the selection and use of the most suitable detector for the selected application and to introduce non familiar readers into this exciting field.


Assuntos
Fótons , Semicondutores , Smartphone
10.
Acta Biomed ; 93(S1): e2022080, 2022 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-35420596

RESUMO

True and false aneurysms (FA) of the subclavian artery are at high risk of rupture due to their localization and proximity/closeness to the articular bone structures of the upper thoracic outlet and shoulders. Surgical and endovascular treatments are good options to avoid complications such as aneurysms rupture, thrombosis and distal embolism alone or in combination. Self-expandable (SE) covered stents are the most used devices for the treatment of subclavian artery aneurysms. We report on a case of post traumatic left intra-thoracic subclavian artery FA treated using endovascular technique, highlighting the usefulness of the new covered Gore Viabahn VBX-BE stent-graft that combines the advantages of a high radial strength of a BE stent with the deliverability and conformability of a SE stent.


Assuntos
Falso Aneurisma , Aneurisma , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma/diagnóstico por imagem , Aneurisma/etiologia , Aneurisma/cirurgia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Prótese Vascular , Humanos , Desenho de Prótese , Stents , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/cirurgia , Resultado do Tratamento
11.
Biosens Bioelectron ; 162: 112232, 2020 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-32452394

RESUMO

The rapid hydrolysis of acetylcholine (ACh), one of the key neurotransmitters in the human body, by the enzyme acetylcholinesterase (AChE) is fundamental for the termination of ACh impulse transmission. Several chemicals, including organophosphorus (OP) pesticides, warfare agents and drugs, are AChE reversible or irreversible inhibitors, thus their rapid on-site detection is of primary importance. Here we report for the first time a chemiluminescence (CL) foldable paper-based biosensor for detection of AChE inhibitors. The biosensor exploits three coupled enzymatic reactions catalyzed by AChE, choline oxidase and horseradish peroxidase, leading to production of hydrogen peroxide, which is measured with an optimized luminol substrate. The origami approach allows to add reagents and trigger the sequential reactions in separate steps. A compact 3D-printed device including a mini dark box was created to enable smartphone detection. The CL foldable paper-based biosensor showed suitable for the rapid detection of OP pesticides in food matrices with a total assay time of 25 min. It is thus a rapid, low cost portable test suitable for point-of-need detection of chemicals inhibiting AChE.


Assuntos
Técnicas Biossensoriais/instrumentação , Inibidores da Colinesterase/análise , Medições Luminescentes/instrumentação , Compostos Organofosforados/análise , Praguicidas/análise , Acetilcolinesterase/metabolismo , Animais , Electrophorus , Desenho de Equipamento , Contaminação de Alimentos/análise
12.
Forensic Sci Int ; 247: 97-104, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25555234

RESUMO

The application of replica molding has proven to be a valuable tool in the analysis of different forensic evidences in particular for its ability to extract the toolmarks from complex sample surfaces. A well known problem in the analysis of ballistic evidences is the accurate characterization of the lateral striae of real bullets seized on crime scenes after shots, due primarily to impact deformations and to unpredictable issues related to laboratory illumination setup. To overcome these problems a possible way is to confine over a flat surface all the features still preserving their three dimensionality. This can be achieved by a novel application of replica molding performed onto the relevant lateral portion of the bullet surface. A quasi-two-dimensional negative copy of the original tridimensional indented surface has been thus fabricated. It combines the real tridimensional topography of class characteristics (land and groove impressions) and of individual caracteristics (striae) impressed by rifled barrels on projectiles, moreover with the possibility of quantitative characterization of these features in a planar configuration, that will allow one-shot comparison of the "whole striae landscape" without the typical artifacts arising from the bullet shape and the illumination issue. A detailed analysis has been carried on at the morphological level by standard optical and scanning electron microscopy, while the 3D topography has been characterized by white light optical profilometry. A quantitative characterization of toolmarks of bullets derived from ammunitions shot by guns of large diffusion, as the Beretta 98 FS cal. 9×21 mm, has been performed and will be presented ranging between the whole landscape and the sub-µm resolution. To investigate the real potentiality of this technique, the experiment has been extended to highly impact-deformed projectiles.


Assuntos
Balística Forense/métodos , Nanotecnologia , Reconhecimento Automatizado de Padrão , Dimetilpolisiloxanos , Armas de Fogo , Microscopia , Microscopia Eletrônica de Varredura
13.
Forensic Sci Int ; 246: 25-30, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25460104

RESUMO

The capability to collect timely information about the substances employed on-site at a crime scene is of fundamental importance during scientific investigations in crimes involving the use of explosives. TNT (2,4,6-trinitrotoluene) is one of the most employed explosives in the 20th century. Despite the growing use of improvised explosives, criminal use and access to TNT is not expected to decrease. Immunoassays are simple and selective analytical tests able to detect molecules and their immunoreactions can occur in portable formats for use on-site. This work demonstrates the application of three immunochemical assays capable of detecting TNT to typical forensic samples from experimental tests: an indirect competitive ELISA with chemiluminescent detection (CL-ELISA), a colorimetric lateral flow immunoassay (LFIA) based on colloidal gold nanoparticles label, and a chemiluminescent-LFIA (CL-LFIA). Under optimised working conditions, the LOD of the colorimetric LFIA and CL-LFIA were 1 µg mL(-1) and 0.05 µg mL(-1), respectively. The total analysis time for LFIAs was 15 min. ELISA proved to be a very effective laboratory approach, showing very good sensitivity (LOD of 0.4 ng mL(-1)) and good reproducibility (CV value about 7%). Samples tested included various materials involved in controlled explosions of improvised explosive devices (IEDs), as well as hand swabs collected after TNT handling tests. In the first group of tests, targets covered with six different materials (metal, plastic, cardboard, carpet fabric, wood and adhesive tape) were fixed on top of wooden poles (180 cm high). Samples of soil from the explosion area and different materials covering the targets were collected after each explosion and analysed. In the second group of tests, hand swabs were collected with and without hand washing after volunteers simulated the manipulation of small charges of TNT. The small amount of solution required for each assay allows for several analyses. Results of immunoassays confirmed that they were suitable to detect post-blast residues in soil and target materials and post transfer residues on hands, allowing further confirmation by more selective techniques. ELISA and LFIAs results obtained from the same solution were consistently in good agreement, and were confirmed by gas chromatography coupled to mass spectrometry (GC-MS). The reported immunoassays data demonstrates the suitability of LFIAs as on-site rapid and effective assays to detect TNT traces. The CL-ELISA proved useful in obtaining very sensitive detection in forensic investigations and testing, while CL-LFIA had performances in between LFIA and CL-ELISA.


Assuntos
Colorimetria , Ensaio de Imunoadsorção Enzimática/métodos , Substâncias Explosivas/análise , Imunoensaio/métodos , Medições Luminescentes/métodos , Trinitrotolueno/análise , Explosões , Ciências Forenses/métodos , Cromatografia Gasosa-Espectrometria de Massas , Mãos , Humanos , Reprodutibilidade dos Testes , Pele/química , Solo/química
14.
J Forensic Sci ; 57(1): 86-92, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22040273

RESUMO

This study takes the first step toward in situ analysis of powder drugs which does not require any alteration of the samples. A fast, inexpensive analytical method based on reflectance near-infrared (NIR) spectrometry and multivariate calibration was applied. A diode-array fiber-optic portable spectrometer in the 900-1700 nm range was employed. Samples were laboratory-prepared ternary powders (diacetylmorphine, caffeine, and paracetamol). Partial least squares regression was applied. The choice of the standard samples for calibration and validation was performed through a D-optimal experimental design. The explained variance was higher than 90%, and the relative root mean square errors were <2%. The number of principal components (6) was very low when compared with the number of raw variables (356 absorbance values). Response plots showed slopes and intercepts were very close to optimal values. Correlation coefficients ranged between 0.909 and 0.989. The method here proposed proved to be competitive with Fourier transform NIR spectrometry.

15.
Forensic Sci Int ; 222(1-3): 288-97, 2012 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-22840283

RESUMO

A novel application of replica molding to a forensic problem, viz. the accurate reproduction of the case head of gun and rifle cartridges, prior and after been shot, is presented. The fabrication of an arbitrary number of identical copies of the region hit by the firing pin and by the breech face is described. The replicas can be (i) handled without damaging the original evidence, (ii) distributed to different law enforcement agencies for comparison against other evidences found on crime scenes or ballistic tests of seized firearms, (iii) maintained on a file by the laboratories. A detailed analysis of the morphological features of the replicas has been carried out by standard microscopy techniques as well as by advanced microscopy such as scanning probe and scanning electron leading to a quantitative morphological characterization of the case heads down to the nanometer scale. The assignment of the cartridge replicas to the shooting weapon is demonstrated to hold below the micron scale, while it is hindered at the nanometer level both by the manufacturing differences and by eventual modifications occurring on the firing pin.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA