Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
2.
Clin Transplant ; 22(5): 587-93, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18460000

RESUMO

BACKGROUND: Chronic renal failure (CRF) is a common complication of calcineurin inhibitor (CNI)-based immunosuppression following cardiac transplantation (HTx). The aim of this prospective study was to evaluate the impact of an immunosuppressive conversion from CNIs to mycophenolate mofetil (MMF) and steroids in cardiac transplant recipients with CRF on renal and cardiac graft function. METHODS: Since 1999, 12 HTx recipients (10 men; 58 +/- 3.6 yr of age; 8.7 +/- 4.2 yr after HTx) with CNI-based immunosuppression and a calculated creatinine clearance (CreaCl) <50 mL/min were included. Most patients (10/12) were on cyclosporine and two patients were on tacrolimus prior inclusion. MMF was started with 0.5 g/d and adjusted according to the target trough levels (2-4 ng/mL). Prednisone dosage was 0.4 mg/kg. Subsequently, CNIs were completely withdrawn. Acute rejection episodes were excluded one and three months after conversion by endomyocardial biopsy and by echocardiography every three months thereafter. RESULTS: After a mean follow-up of 20 +/- 16 months, CreaCl improved significantly: pre-conversion vs. post-conversion: 32.8 +/- 12.2 mg/dL vs. 42.8 +/- 21.14 mg/dL, p = 0.03. However, four acute rejection episodes occurred and patients were reconverted to CNIs. Additionally, six patients had a new onset of graft vessel disease (GVD) one yr after conversion. As a result of these adverse events, the study was stopped after inclusion of only 12 of the scheduled 30 patients. CONCLUSIONS: Conversion to MMF and steroids after HTx improves renal function, but increases the risk for recurrent rejection and GVD. Therefore, MMF and steroids should only be considered in patients with a markedly low risk for rejection.


Assuntos
Inibidores de Calcineurina , Transplante de Coração/efeitos adversos , Imunossupressores/uso terapêutico , Falência Renal Crônica/induzido quimicamente , Ácido Micofenólico/análogos & derivados , Esteroides/uso terapêutico , Ciclosporina/efeitos adversos , Quimioterapia Combinada , Feminino , Taxa de Filtração Glomerular , Humanos , Falência Renal Crônica/prevenção & controle , Masculino , Pessoa de Meia-Idade , Ácido Micofenólico/uso terapêutico , Estudos Prospectivos , Tacrolimo/efeitos adversos
3.
Tex Heart Inst J ; 35(1): 32-5, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18427648

RESUMO

Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is a rare congenital defect. This anomaly leads to a coronary hypoperfusion phenomenon and to substantial left ventricular dysfunction caused by abnormal perfusion of the left ventricle. The optimal surgical management of such cases is not clearly established. Here, we report the successful anatomic repair of ALCAPA arising from the non-facing sinus of Valsalva of the pulmonary artery in a 5-kg patient. In order to perform the repair, we created an autologous extrapulmonary tunnel (from a pulmonary artery flap and autologous pericardium), which we implanted into the ascending aorta. Because of post-cardiotomy heart failure, we implanted an extracorporeal membrane oxygenation device during the same procedure. After recovery of the failing heart, the device was easily ex-planted, and the patient was discharged from the hospital on postoperative day 30.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Anomalias dos Vasos Coronários/cirurgia , Angiografia Coronária , Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca/etiologia , Humanos , Lactente , Pericárdio/transplante , Artéria Pulmonar/anormalidades , Artéria Pulmonar/cirurgia , Transplante Autólogo
4.
Eur J Cardiothorac Surg ; 31(3): 339-43; discussion 343, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17239612

RESUMO

OBJECTIVE: Donor organ shortage in pediatric heart transplantation (HTx) is causing mortality rates of 30-50% on the waiting list. Due to immaturity of the immune system of newborns and infants, ABO-incompatible HTx may be an option to increase donor availability. We present our experience with ABO-incompatible HTx. METHODS: Three infants were transplanted ABO-incompatible since 12/2004: (1) hypoplastic left heart complex, (2) restrictive hypertrophic cardiomyopathy, (3) dilative cardiomyopathy. Age at HTx was 7, 5, and 3.5 months. All recipients had blood type O, donors were A, A, and B. Informed consent was given by parents, the ethics committee, and Eurotransplant. RESULTS: Preoperative isohemagglutinin titers were low (Patient 1: 1:4 for anti-A1, A2, B, Patient 2: 1:4, 1:1, 1:4 for anti-A1, A2, B, respectively, and Patient 3: 0 for all, but quick spin 1+ for all). Intraoperatively, plasma was separated from red blood cells and discarded up to six times until antibodies were eliminated. Immunosuppressive induction with ATG was started for 5 days. Basic immunosuppression consisted of tacrolimus, mycophenolate mofetil, and prednisone. Extubation was performed on days 15, 2, and 1, respectively. After a follow-up of 17, 16, and 12 months all patients are well, ventricular function is excellent without any acute rejection periods; Patient 1 is still on dialysis. Isohemagglutinin titers against donor blood type have disappeared in follow-up. CONCLUSIONS: ABO-incompatible cardiac transplantation shows good short-term results in young infants and seems to be a safe procedure to lower the mortality on the waiting list.


Assuntos
Incompatibilidade de Grupos Sanguíneos , Cardiopatias Congênitas/cirurgia , Transplante de Coração/métodos , Sistema ABO de Grupos Sanguíneos , Tipagem e Reações Cruzadas Sanguíneas/métodos , Feminino , Seguimentos , Hemaglutininas/sangue , Humanos , Imunossupressores/uso terapêutico , Lactente , Masculino , Cuidados Pós-Operatórios/métodos , Período Pós-Operatório , Cuidados Pré-Operatórios/métodos , Resultado do Tratamento
5.
Eur J Cardiothorac Surg ; 30(4): 675-7, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16893652

RESUMO

Truncus arteriosus communis is a congenital heart malformation, which is usually repaired in the neonatal period or early infancy. Although results of repair are good, there is long-term morbidity caused by reoperations mainly owing to right ventricle to pulmonary artery conduit exchange or stenosis at the pulmonary artery bifurcation as recently reported for Contegra conduits. We present a new technique for complete autologous reconstruction of the aorta and the pulmonary bifurcation in truncus arteriosus type I and II.


Assuntos
Aorta/cirurgia , Artéria Pulmonar/cirurgia , Persistência do Tronco Arterial/cirurgia , Anastomose Cirúrgica , Humanos , Recém-Nascido , Tronco Arterial/cirurgia
6.
ASAIO J ; 52(5): 575-80, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16966862

RESUMO

In children, systemic heart valve replacement with bioprostheses is associated with accelerated valve degeneration, and mechanical prostheses require permanent anticoagulation. Novel "biomechanical" polymeric valve prostheses ("bio" = flexible, "mechanical" = synthetic), solely made of polycarbonate urethane (PCU), were tested in vitro and in a growing animal (calf) model with the aim of improved durability without permanent anticoagulation. The trileaflet aortic prosthesis has diminished pressure loss and reduced stress and strain peaks. The asymmetric bileaflet mitral valve mimics natural nonaxial inflow. The valves underwent long-term in vitro testing and in vivo testing in growing calves for 20 weeks [mitral (7), aortic (7)] with comparison to different commercial bioprostheses [mitral (7), aortic (2)]. In vitro durability of PCU valves was proved up to 20 years. Survival of PCU valves versus bioprostheses was 7 versus 2 mitral and 5 versus 0 aortic valves, respectively. Two animals with PCU aortic valves died of pannus overgrowth causing left ventricular outflow tract obstruction. Degeneration and calcification were mild (mitral) and moderate (aortic) in PCU valves but were severe in biological valves. There was no increased thrombogenicity of the PCU valves compared to bioprostheses. The novel polymeric valve prostheses revealed superior durability compared to current bioprostheses in growing animal model without permanent anticoagulation and thus, may be a future option for pediatric patients.


Assuntos
Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/tendências , Valva Mitral/cirurgia , Animais , Fenômenos Biomecânicos , Bovinos , Criança , Humanos , Polímeros , Desenho de Prótese
7.
Circulation ; 108 Suppl 1: II134-9, 2003 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-12970222

RESUMO

BACKGROUND: Current heart valve prostheses are constructed mimicking the native aortic valve. Special hemodynamic characteristics of the mitral valve such as a nonaxial central inflow with creation of a left ventricular vortex have so far not been taken into account. A new polycarbonaturethane (PCU) bileaflet heart valve prosthesis with special design for the mitral position is introduced, and results of animal testing are presented. METHODS AND RESULTS: After in vitro testing, 7 PCU-prostheses and 7 commercial bioprostheses (Perimount, n=4; Mosaic, n=3) were implanted in mitral position into growing Jersey calves (age 3-5 months, weight 60-97 kg) for 20 weeks. 2-Dimensional echocardiography was performed after implantation and before sacrification. Autopsy included histologic, radiographic, and electron microscopic examination of the valves. In vitro durability was proven for >15 years. After implantation 2-dimensional-echocardiography showed no relevant gradient or regurgitation of any prosthesis. Clinical course of the animals with PCU valves was excellent. In contrast, 5 of 7 calves with bioprostheses were sacrificed after 1-9 weeks because of congestive heart failure. 2-Dimensional echocardiography of the PCU valves after 20 weeks showed mild leaflet thickening with trivial regurgitation; mean gradient was 8.1+/-5.0 mm Hg (weight: 160-170 kg). The explanted PCU prostheses revealed mild calcification and no structural degeneration. All of the Perimount bioprostheses were severely calcified and degenerated after 11+/-7 weeks. One Mosaic bioprosthesis was thrombosed after 1 week, and 2 showed severe and mild-to-moderate degeneration after 4 and 22 weeks, respectively. CONCLUSIONS: Polycarbonaturethane valve prostheses with special design for mitral position show excellent hemodynamic performance and durability in vivo. Calcification and structural changes are mild compared with bioprostheses. Controlled clinical studies are planned.


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Poliuretanos , Animais , Bioprótese , Bovinos , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/patologia , Radiografia , Ultrassonografia
8.
Eur J Cardiothorac Surg ; 27(2): 235-42, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15691676

RESUMO

OBJECTIVE: Biventricular pacing has demonstrated improvement in cardiac function in treating congestive heart failure (CHF). Two different operative strategies (coronary sinus vs. epicardial stimulation) for left ventricular (LV) pacing were compared. METHODS: Since April 1999, a total of 86 patients (pts, age: 63+/-10 years) with depressed systolic LV function (mean ejection fraction 24+/-9%), left bundle-branch-block (mean QRS 182+/-22 ms) and congestive heart failure NYHA III or higher were enrolled. For biventricular stimulation coronary sinus (CS) leads were placed in 79 pts. Nine of these devices were converted to surgical epicardial LV-leads, because of CS-lead failure. In 7 patients epicardial LV-leads were initially implanted surgically, accounting for a total of 16 pts with surgical placed epicardial steroid-eluting LV-leads. For these, a limited left-lateral thoracotomy (7+/-4 cm) was used. Thirty-three (38%) pts had an indication for a defibrillator. The mean follow-up time was 16.4+/-15.4 months (0.1-45 months), representing 107.1 patient-years. RESULTS: In the biventricular pacing mode, QRS duration decreased to 143+/-16 ms (P<0.001). Threshold capture of the CS-leads increased significantly compared to surgically placed epicardial leads (18 month control: 2.2+/-1.4V/0.5 ms vs. 0.7+/-0.3V/0.5 ms), which had no increase in threshold (P<0.001). At the 18 month follow-up 7 CS-leads had a threshold of >4V/0.5 ms vs. epicardial leads which were under 1.1V/0.5 ms, except for one (1.8V/0.5 ms). After CS-lead implantation 25 LV-lead related complications occurred, (failed implantation, CS-dissection, loss of pacing capture, diaphragm stimulation or lead dislodgment), vs. one dislodgement after surgical epicardial lead placement (P<0.05). Correct lead positioning (obtuse marginal branch area) was achieved in all surgical epicardial placements but only in 70% with CS-leads (P<0.03). In the follow up period, 9 pts died (4 cardiac related). Heart transplantation was necessary in 4 pts due to deterioration of the cardiomyopathy. CONCLUSIONS: Surgical epicardial lead placement revealed excellent long-term results and a lower LV-related complication rate compared to CS-leads. Although, the approach via limited thoracotomy for biventricular pacing is associated with 'more surgery', it is a safe and reliable technique and should be considered as an equal alternative.


Assuntos
Bloqueio de Ramo/cirurgia , Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/cirurgia , Disfunção Ventricular Esquerda/cirurgia , Bloqueio de Ramo/mortalidade , Bloqueio de Ramo/fisiopatologia , Eletrodos Implantados , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Tempo de Internação , Pessoa de Meia-Idade , Marca-Passo Artificial , Pericárdio/fisiopatologia , Pericárdio/cirurgia , Complicações Pós-Operatórias/fisiopatologia , Nó Sinoatrial/fisiopatologia , Nó Sinoatrial/cirurgia , Resultado do Tratamento , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia
9.
ASAIO J ; 51(5): 498-500, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16322704

RESUMO

Mechanical circulatory support is successfully applied to patients with low cardiac output. The MEDOS-System provides pulsatile ventricular assistance for patients of all age groups, including neonates. We report our experience with seven consecutive pediatric patients with the MEDOS-VAD. The indication was bridge to transplantation in all patients. Mean age was 7.3 +/- 6.5 years (range 0.75-16.9 years) and mean weight was 26.3 +/- 21.7 kg (range 5.9-60 kg). Perioperative survival was 100%; complications occurred in six patients (86%; two cerebral embolism/bleeding, two rethoracotomy, two exchange of pump chamber due to thrombus formation after 4 and 9 days). Mean duration of support was 20.4 +/- 10.8 days (range 6-38 days). Bilirubin decreased from 3.5 +/- 2.6 mg/d to 2.1 +/- 1.2 mg/d. Hospital mortality was three of seven patients who did not receive an organ offer in time. All patients who underwent subsequent heart transplantation (four of seven patients; 57%) were discharged from the hospital. Mechanical circulatory support with the MEDOS-System can be performed successfully in pediatric patients of any age. Secondary organ functions improve under this pulsatile circulatory assistance. Hemorrhage and thromboembolic events are the most frequent complications.


Assuntos
Coração Auxiliar , Mecânica , Adolescente , Baixo Débito Cardíaco/terapia , Cardiomiopatias/terapia , Criança , Pré-Escolar , Desenho de Equipamento , Feminino , Seguimentos , Alemanha , Transplante de Coração , Coração Auxiliar/efeitos adversos , Mortalidade Hospitalar , Humanos , Lactente , Masculino , Miocardite/terapia , Complicações Pós-Operatórias , Reoperação/mortalidade , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Taxa de Sobrevida , Tromboembolia/etiologia , Fatores de Tempo , Resultado do Tratamento
10.
Transplantation ; 77(4): 568-74, 2004 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-15084937

RESUMO

BACKGROUND: Calcineurin-inhibitor (CNI)-related renal failure is a common problem after cardiac transplantation (HTx). The aim of this study was to introduce a CNI-free immunosuppressive regimen to HTx recipients with late posttransplant renal impairment and to evaluate the impact of conversion to this new immunosuppression (mycophenolate mofetil [MMF] and sirolimus [Sir]) treatment on renal function. METHODS AND RESULTS: Thirty-one HTx patients (25 men, 6 women; 0.2-14.2 years after transplantation) with CNI-based immunosuppression and a serum creatinine greater than 1.9 mg/dL were included in the study. Creatinine and cystatin levels were monitored to detect renal function. Mean patient age was 50+/-14 (range 19-74) years. Conversion was started with 6 mg Sir, continued with 2 mg, and the dose was adjusted to achieve target trough levels between 8 and 14 ng/mL. MMF was continued with trough level adjusted (1.5-4 microg/mL). Subsequently, the CNIs were tapered down and stopped. Clinical follow-up (first and every 3 months after conversion) included endomyocardial biopsies, echocardiography, and laboratory studies. Survival was 90% after a mean follow-up of 13+/-95 months. No acute rejection episode was detected during the study period. Renal function improved significantly after conversion: creatinine preconversion vs. postconversion: 3.14+/-0.76 mg/dL vs. 2.14+/-0.83 mg/dL, P =0.001. Cystatin preconversion vs. postconversion: 2.95+/-1.06 mg/L vs. 2.02+/-1.1 mg/L, P =0.01. In three patients, hemodialysis therapy was stopped completely after conversion. Graft function remained stable. Fractional shortening preconversion vs. postconversion: 36.9+/-6% vs. 36.4+/-6%. There were no serious adverse events. One patient had to be excluded because of noncompliance. CONCLUSIONS: Conversion from CNI-based immunosuppression to MMF and Sir in HTx patients with chronic renal failure was safe, preserved graft function, and improved renal function.


Assuntos
Inibidores de Calcineurina , Transplante de Coração , Imunossupressores/uso terapêutico , Falência Renal Crônica/induzido quimicamente , Falência Renal Crônica/tratamento farmacológico , Ácido Micofenólico/análogos & derivados , Ácido Micofenólico/uso terapêutico , Sirolimo/uso terapêutico , Adulto , Sistema Cardiovascular/fisiopatologia , Relação Dose-Resposta a Droga , Feminino , Coração/fisiopatologia , Humanos , Imunossupressores/administração & dosagem , Imunossupressores/efeitos adversos , Rim/fisiopatologia , Falência Renal Crônica/fisiopatologia , Masculino , Pessoa de Meia-Idade , Ácido Micofenólico/administração & dosagem , Ácido Micofenólico/efeitos adversos , Ácido Micofenólico/sangue , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo
11.
J Heart Lung Transplant ; 23(6): 770-3, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15366440

RESUMO

Chronic renal failure triggered by calcineurin inhibitor (CNI)-based immunosuppression is a common complication after cardiac transplantation. Sirolimus and mycophenolate mofetil (MMF) are 2 newer immunosuppressive agents with no documented nephrotoxic side effects. This case report describes a patient with ongoing chronic renal failure 10 months after cardiac transplantation on cyclosporine-based immunosuppressive therapy. Conversion of the immunosuppressive regimen from cyclosporine to sirolimus and MMF resulted in freedom from acute rejection, excellent cardiac graft function and consistently improved renal function. This case illustrates the beneficial potential of sirolimus and MMF as CNI-free and safe long-term immunosuppression in a patient with chronic renal failure after heart transplantation.


Assuntos
Transplante de Coração , Imunossupressores/uso terapêutico , Falência Renal Crônica/prevenção & controle , Ácido Micofenólico/análogos & derivados , Ácido Micofenólico/uso terapêutico , Sirolimo/uso terapêutico , Calcineurina/efeitos adversos , Inibidores de Calcineurina , Humanos , Falência Renal Crônica/induzido quimicamente , Masculino , Pessoa de Meia-Idade
12.
Ann Thorac Surg ; 77(6): 2151-6, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15172286

RESUMO

BACKGROUND: Since introduction in 1999, pulmonary valve replacement in pediatric patients with the Contegra conduit (Medtronic Inc, Minneapolis, MN) has gained widespread application with increasing enthusiasm. However, unexpected graft related adverse effects may occur. METHODS: Between April 2001 and December 2002, 29 patients (20 male; mean age, 3.39 +/- 3.66 years; range, 0.01 to 13.0 years; mean weight, 11.62 +/- 8.73 kg) underwent right ventricular outflow tract reconstruction with the Contegra conduit. Seventeen patients underwent primary repair, 8 had prior homografts, and 4 had other previous operations. RESULTS: There were no deaths. Three early graft related complications were observed. In two infants (age, 1.8 and 3.5 months; weight, 3.6 and 3.8 kg, respectively) thrombus formation at the conduit valve was detected 2 weeks postoperatively. Under anticoagulation with low-molecular-weight heparin, thrombi resolved completely in both patients. One patient (4.5 months, 4.43 kg) developed severe regurgitation due to a fibrous layer covering the inner conduit wall and required conduit exchange 3 weeks postoperatively. After a mean follow-up time of 10.2 +/- 6.4 months all patients are in good clinical condition. However, one patient with systemic right ventricular pressure developed pseudoaneurysm at both graft insertion sites and is scheduled for reoperation. Two other patients underwent balloon dilation. Freedom from reoperation and intervention at 1 year is 89.4%. With regard to regurgitation and conduit stenosis all other conduits perform well. CONCLUSIONS: Contegra conduits are an alternative to homografts for right ventricular outflow tract reconstruction. However, there is a risk of thrombus formation in small infants so that prophylactic anticoagulation may be necessary. Patients with systemic right ventricular pressure require close observation as pseudoaneurysm formation has been observed.


Assuntos
Bioprótese , Prótese Vascular , Próteses Valvulares Cardíacas , Ventrículos do Coração/cirurgia , Artéria Pulmonar/cirurgia , Adolescente , Bioprótese/efeitos adversos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Masculino , Complicações Pós-Operatórias , Trombose/etiologia
13.
Ann Thorac Surg ; 73(6): 1778-85, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12078769

RESUMO

BACKGROUND: Patients with absent pulmonary valve syndrome (APVS) with respiratory distress (RD) have previously had a high mortality. In 1990 we adopted a strategy of primary repair including total replacement of the aneurysmal central pulmonary arteries (PAs) for patients with RD. METHODS: Retrospective review was made of 54 consecutive patients with APVS between 1960 and 1998. Median age and weight were 4 months and 4.8 kg. RD was present in 23 patients (10 neonates, 16 required ventilation). Fifteen patients had repair with homograft replacement of the PAs and VSD closure (group 1). Twenty-seven patients had transannular patch with VSD closure with PA-plasty (group 2, n = 21) or without PA plasty (group 3, n = 6). Twelve had miscellaneous procedures (group 4); in 6 the VSD was left open. RESULTS: Operative, 1-, 5-, and 10-year survivals were 83%, 80%, 78%, and 78%, respectively. Risk factors for operative mortality in multivariate analysis were RD (p = 0.04), neonates (p = 0.02), weight less than 3 kg (p = 0.02), open VSD (p = 0.02) and surgery before 1990 (p = 0.04). Since 1990 operative mortality has decreased to 11% (p = 0.04). RD was the only time-related predictor of survival in multivariate analysis (p = 0.004). In patients with RD, survival with homograft was 73% versus 41% with other techniques (p = 0.2). Mean follow-up was 72 +/- 50 months. There were no significant differences in freedom from reintervention rates among the surgical groups (p = 0.08). CONCLUSIONS: Aggressive homograft replacement of the central pulmonary arteries has been associated with improved survival in patients with APVS especially in neonates with severe RD.


Assuntos
Anormalidades Múltiplas/cirurgia , Aneurisma/cirurgia , Artéria Pulmonar/transplante , Valva Pulmonar/anormalidades , Tetralogia de Fallot/cirurgia , Anormalidades Múltiplas/mortalidade , Aneurisma/mortalidade , Feminino , Seguimentos , Humanos , Lactente , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Taxa de Sobrevida , Síndrome , Tetralogia de Fallot/mortalidade , Procedimentos Cirúrgicos Vasculares/métodos
14.
Eur J Cardiothorac Surg ; 25(3): 333-41, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15019657

RESUMO

OBJECTIVE: Calcineurin inhibitor (CNI)-related renal failure is a common problem after cardiac transplantation (HTx). The aim of this prospective study was to evaluate the safety and efficacy of a completely CNI-free immunosuppressive regimen [mycophenolate mofetil (MMF) and sirolimus (Sir)] in HTx-recipients with late post-transplant renal impairment. METHODS: Since 2001, 30 HTx-patients (25 men, 6 women; 0.2-14.2 years after transplantation) with CNI-based immunosuppression and a serum creatinine >1.9 mg/dl were included in the study. Creatinine and cystatin levels were monitored to detect renal function. Conversion was started with 6 mg Sir or 500 mg MMF according to the pre-existing regimen and was continued with the dose adjusted to achieve target trough levels between 8 and 14 ng/ml (Sir) or 1.5 and 4 microg/ml (mycophenolate). Subsequently, the CNIs were tapered down and stopped. Clinical follow-up included endomyocardial biopsies, echocardiography and laboratory studies. Additionally, every HTx-patient treated at our centre between 1996 and 2001 due to chronic renal failure without immunosuppressive conversion and fulfilling the inclusion criteria were retrospectively analysed and acted as control group. RESULTS: Patient demographics and 1-year survival [93 (conversion) vs 90% (control)] were compared. No acute rejection episode was detected in either group. Renal function improved significantly in the conversion group (creatinine: 3.18+/-0.71 vs 2.22+/-0.79 mg/dl, P=0.001; cystatin pre- vs post-conversion: 2.95+/-1.06 vs 2.02+/-1.1 mg/l, P=0.01). In three patients haemodialysis therapy was stopped completely after conversion. In the control group renal impairment was deteriorating, creatinine increased from 2.44+/-0.8 to 3.28+/-1 mg/dl (P=0.01). In 10 out of 33 patients chronic haemodialysis had to be initiated within 1 year. Although side effects of CNI-free immunosuppression were common (76%), no patient had to be excluded due to adverse effects. CONCLUSIONS: Conversion from CNI-based immunosuppression to MMF and Sir in HTx-patients with chronic renal failure was safe, preserved graft function and improved renal function.


Assuntos
Inibidores de Calcineurina , Transplante de Coração , Imunossupressores/uso terapêutico , Falência Renal Crônica/prevenção & controle , Ácido Micofenólico/análogos & derivados , Ácido Micofenólico/uso terapêutico , Sirolimo/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Quimioterapia Combinada , Feminino , Rejeição de Enxerto/etiologia , Sobrevivência de Enxerto , Humanos , Falência Renal Crônica/induzido quimicamente , Falência Renal Crônica/fisiopatologia , Masculino , Pessoa de Meia-Idade , Ácido Micofenólico/efeitos adversos , Complicações Pós-Operatórias/induzido quimicamente , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Sirolimo/efeitos adversos
15.
Eur J Cardiothorac Surg ; 25(6): 946-52, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15144993

RESUMO

OBJECTIVE: Current prosthetic heart valves necessitate permanent anticoagulation or have limited durability and impaired hemodynamic performance compared to natural valves. Recently a polymeric valve prostheses with special design for mitral position demonstrated excellent in vitro and in vivo results with improved durability and no need for permanent anticoagulation. In this study, a respective flexible polymeric aortic valve is presented and in vitro and in vivo results are reported. METHODS: The aortic prosthesis (ADIAM lifescience AG, Erkelenz, Germany) is entirely made of polycarbonaturethane. The tri-leaflet flexible prosthesis mimicks the natural aortic valve and has a diminished pressure loss and reduced stress and strain peaks at the commissures. The valve underwent long-term in vitro testing and in vivo-testing in a growing calve animal model (20 weeks, 7 aortic valves) and was compared to two different commercial bioprostheses. RESULTS: The polymeric aortic heart valve substitute demonstrated excellent in vitro and in vivo hemodynamics. Five/seven animals with aortic PCU-prostheses had an excellent clinical long-term course. The explanted valves showed a variable degree of calcification. Two of the seven animals died at 27 and 77 days due to pannus overgrowth causing severe LVOTO without degeneration of the valve itself. Both animals with commercial bioprostheses had to be sacrificed because of congestive heart failure related to structural degeneration of the bioprosthesis after 10 and 30 days of implantation. There was no increased thrombogenity of the PCU valves compared to bioprostheses. CONCLUSION: The new flexible polymeric aortic valve prosthesis is superior to current bioprostheses in animal testing.


Assuntos
Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Animais , Bioprótese , Bovinos , Feminino , Implante de Prótese de Valva Cardíaca , Teste de Materiais/métodos , Poliuretanos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
16.
Acta Cardiol ; 59(6): 624-9, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15636446

RESUMO

OBJECTIVE: The aim of our study was to investigate the systemic inflammatory response in children with congenital heart disease undergoing surgical correction with cardiopulmonary bypass. We wanted to discuss interleukin 6 and procalcitonin as components of the systemic inflammatory response syndrome to cardiopulmonary bypass and evaluate postoperative kinetics of these parameters in case of an uncomplicated course. METHODS: Procalcitonin and interleukin 6 were determined before and after cardiopulmonary bypass surgery in 37 children on the day of surgery, the first and fourth postoperative day. The increased procalcitonin and interleukin 6 levels were evaluated in relationship to intraoperative variables such as duration of aortic cross clamping, incisional trauma and cardiac bypass temperature. RESULTS: Peak levels of procalcitonin were detected on the first postoperative day, while interleukin 6 reached its highest values on the day of surgery. In contrast to interleukin 6 the median values of procalcitonin differed significantly between short versus long aortic clamping time and atriotomy versus ventriculotomy. Interleukin 6 reached normal levels on the fourth postoperative day, while procalcitonin was still clearly above normal. CONCLUSIONS: Serum concentrations of procalcitonin and interleukin 6 were influenced by systemic inflammatory response syndrome following cardiac surgery with cardiopulmonary bypass. Even in case of an uncomplicated course both parameters were elevated for at least four days. While procalcitonin serum concentrations were dependent on aortic clamping time or incisional trauma, interleukin 6 showed no significant relation with these intraoperative variables.


Assuntos
Calcitonina/sangue , Ponte Cardiopulmonar , Cardiopatias Congênitas/sangue , Cardiopatias Congênitas/cirurgia , Interleucina-6/sangue , Precursores de Proteínas/sangue , Peptídeo Relacionado com Gene de Calcitonina , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino
17.
Heart Surg Forum ; 7(5): E525-32, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15799940

RESUMO

OBJECTIVE: Current prosthetic heart valves necessitate permanent anticoagulation or have limited durability and impaired hemodynamic performance compared with natural valves. We report in vivo and in vitro results with new polymeric valve prostheses that have a special design for the mitral and aortic positions. The aims are improved durability and elimination of the need for permanent anticoagulation. METHODS: The mitral and aortic prostheses (Adiam Life Science, Erkelenz, Germany) are made entirely of polycarbonate urethane (PCU). The bileaflet asymmetric mitral valve mimics natural, nonaxial inflow, which creates a left ventricular vortex, saving energy for systolic ejection of blood. The trileaflet aortic prosthesis has diminished pressure loss and reduced stress and strain peaks at the commissures. The valves were subjected to long-term in vitro testing and in vivo testing in a growing calf model (20 weeks; 7 mitral and 7 aortic valves) with comparison with 2 commercial bioprostheses (7 mitral, 2 aortic). Two-dimensional echocardiography was performed after implantation and prior to sacrifice with autopsy and valve examination. RESULTS: In vitro durability of the PCU valves was proved up to 20 years. In vivo durability and hemodynamics were superior to those of all bioprostheses. Survival of PCU valves versus bioprostheses was 7 versus 2 mitral valves and 5 versus 0 aortic valves, respectively. Two animals with PCU aortic valves died of pannus overgrowth that caused severe left ventricular outflow tract obstruction without changes in the valves. Degeneration and calcification were mild (mitral) and moderate (aortic) in PCU valves but were severe in biological valves. There was no increased thrombogenicity of the PCU valves compared with bioprostheses. CONCLUSION: The new flexible polymeric aortic and mitral valve prostheses were superior to current bioprostheses in animal testing.


Assuntos
Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Desenho de Equipamento , Análise de Falha de Equipamento , Polímeros
18.
Postgrad Med ; 126(3): 274-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24977344

RESUMO

We report on the case of a 13-year-old female presenting with dizziness and nausea related to high blood pressure. A complete medical evaluation revealed that the patient had middle-aortic syndrome (MAS), in which there was a severe stenosis of the abdominal aorta that affected her renal and visceral arteries. If left untreated, this syndrome may lead to serious complications such as renal insufficiency or congestive heart failure. Therefore, the decision was made to perform a thoracoabdominal surgery with surgical patch augmentation. The patient had successful postoperative recovery. We have reported this case to draw attention to the coarctation of abdominal aorta, a condition which should be considered in pediatric patients with hypertension, and to emphasize a successful treatment approach for MAS.


Assuntos
Aorta Abdominal , Doenças da Aorta/diagnóstico , Adolescente , Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Constrição Patológica , Humanos , Hipertensão/complicações , Masculino , Radiografia , Artéria Renal
20.
Interact Cardiovasc Thorac Surg ; 14(3): 253-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22159262

RESUMO

In this investigation, we hypothesize that quality of oral anticoagulation (OA) and long-term outcome after mechanical heart valve (MHV) replacement with self-management (Self-M) of OA is superior to conventional anticoagulation treatment (Conv-T), even in outside trial conditions. One hundred sixty patients (78.8% aortic valve replacements) were trained in international normalized ratio Self-M and 260 patients (86.2% aortic valve replacements) preferred Conv-T. Mean follow-up was 8.6 ± 2.1 years, representing 3612 patient-years. During follow-up, 37.2% bleedings and 10.6% thromboembolic events were recorded in the Self-M group versus 39.6% bleedings (P = 0.213) and 15.4% thromboembolic events (P = 0.064) in the Conv-T group. Serious adverse events were significantly lower in the Self-M group [grade III bleeding events causing disability or death: 0 versus 4.6% (P = 0.03); grade III thromboembolic events: 0.6 versus 5.0% (P = 0.011)]. Patients with Self-M were significantly more satisfied with their OA management and their quality of life (P < 0.001). Actuarial survival after 1, 5 and 10 years was 100, 99 and 97 with Self-M and 100, 95 and 81% with Conv-T, respectively (P < 0.001). Univariate risk factors for mortality were age (P = 0.008), type of operation (P = 0.021) and conventional OA (P < 0.001). In multivariate analysis, only conventional OA reached significance (P < 0.001). We conclude that in a routine setting under outside trial conditions Self-M of OA improves long-term outcome and treatment quality.


Assuntos
Anticoagulantes/administração & dosagem , Próteses Valvulares Cardíacas , Satisfação do Paciente , Complicações Pós-Operatórias/prevenção & controle , Autocuidado/métodos , Trombose/prevenção & controle , Administração Oral , Idoso , Relação Dose-Resposta a Droga , Feminino , Seguimentos , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Qualidade de Vida , Estudos Retrospectivos , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA