RESUMO
Identifying and treating pediatric arrhythmias is essential for pediatric anesthesiologists. Pediatric patients can present with narrow or wide complex tachycardias, though the former is more common. Patients with inherited channelopathies or cardiomyopathies are at increased risk. Since most pediatric patients present for anesthesia without a baseline electrocardiogram, the first identification of an arrhythmia may occur under general anesthesia. Supraventricular tachycardia, the most common pediatric tachyarrhythmia, represents a broad category of predominately narrow complex tachycardias. Stimulating events including intubation, vascular guidewire manipulation, and surgical stimulation can trigger episodes. Valsalva maneuvers are unreliable as treatment, making adenosine or other intravenous antiarrhythmics the preferred acute therapy. Reentrant tachycardias are the most common supraventricular tachycardia in pediatric patients, including atrioventricular reciprocating tachycardia (due to a distinct accessory pathway) and atrioventricular nodal reentrant tachycardia (due to an accessory pathway within the atrioventricular node). Patients with ventricular preexcitation, often referred to as Wolff-Parkinson-White syndrome, have a wide QRS with short PR interval, indicating antegrade conduction through the accessory pathway. These patients are at risk for sudden death if atrial fibrillation degenerates into ventricular fibrillation over a high-risk accessory pathway. Automatic tachycardias, such as atrial tachycardia and junctional ectopic tachycardia, are causes of supraventricular tachycardia in pediatric patients, the latter most typically noted after cardiac surgery. Patients with inherited arrhythmia syndromes, such as congenital long QT syndrome, are at risk of developing ventricular arrhythmias such as polymorphic ventricular tachycardia (Torsades de Pointes) which can be exacerbated by QT prolonging medications. Patients with catecholaminergic polymorphic ventricular tachycardia are at particular risk for developing bidirectional ventricular tachycardia or ventricular fibrillation during exogenous or endogenous catecholamine surges. Non-selective beta blockers are first line for most forms of long QT syndrome as well as catecholaminergic polymorphic ventricular tachycardia. Anesthesiologists should review the impact of medications on the QT interval and transmural dispersion of repolarization, to limit increasing the risk of Torsades de Pointes in patients with long QT syndrome. This review explores the key anesthetic considerations for these arrhythmias.
Assuntos
Arritmias Cardíacas , Humanos , Criança , Anestesiologistas , Eletrocardiografia , Anestesia/métodos , Pediatria/métodosRESUMO
Cardiac implantable electronic device (CIED) remote transmissions are an integral part of longitudinal follow-up in pediatric and adult congenital heart disease (ACHD) patients. To evaluate baseline CIED remote monitoring (RM) data among pediatric and ACHD centers prior to implementation of a Pediatric and Congenital Electrophysiology Society (PACES)-sponsored quality improvement (QI) project. This is a cross-sectional study of baseline CIED RM. Centers self-reported baseline data: individual center RM compliance was defined as high if there was > 80% achievement and low if < 50%. A total of 22 pediatric centers in the USA and Australia submitted baseline data. Non-physicians were responsible for management of the RM program in most centers: registered nurse (36%), advanced practice provider (27%), combination (23%), and third party (9%). Fifteen centers (68%) reported that > 80% of their CIED patients are enrolled in RM and only two centers reported < 50% participation. 36% reported high compliance of device transmission within 14 days of implant and 77% of centers reported high compliance of CIED patients enrolled in RM. The number of centers achieving high compliance differed by device type: 36% for pacemakers, 50% for ICDs, and 55% for Implantable Cardiac Monitors (ICM). All centers reported at least 50% adherence to recommended follow-up for PM and ICD, with 23% low compliance rate for ICMs. Based on this cross-sectional survey of pediatric and ACHD centers, compliance with CIED RM is sub-optimal. The PACES-sponsored QI initiative will provide resources and support to participating centers and repeat data will be evaluated after PDSA cycles.
Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Marca-Passo Artificial , Criança , Humanos , Adulto , Cardiopatias Congênitas/terapia , Estudos Transversais , Melhoria de Qualidade , Tecnologia de Sensoriamento RemotoRESUMO
Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.
Assuntos
Monitorização Fisiológica , Telemetria , HumanosRESUMO
In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.
Assuntos
Cardiologia , Desfibriladores Implantáveis , American Heart Association , Eletrofisiologia Cardíaca , Criança , Consenso , Eletrônica , Humanos , Estados UnidosRESUMO
Guidelines for the implantation of cardiac implantable electronic devices (CIEDs) have evolved since publication of the initial ACC/AHA pacemaker guidelines in 1984 [1]. CIEDs have evolved to include novel forms of cardiac pacing, the development of implantable cardioverter defibrillators (ICDs) and the introduction of devices for long term monitoring of heart rhythm and other physiologic parameters. In view of the increasing complexity of both devices and patients, practice guidelines, by necessity, have become increasingly specific. In 2018, the ACC/AHA/HRS published Guidelines on the Evaluation and Management of Patients with Bradycardia and Cardiac Conduction Delay [2], which were specific recommendations for patients >18 years of age. This age-specific threshold was established in view of the differing indications for CIEDs in young patients as well as size-specific technology factors. Therefore, the following document was developed to update and further delineate indications for the use and management of CIEDs in pediatric patients, defined as ≤21 years of age, with recognition that there is often overlap in the care of patents between 18 and 21 years of age. This document is an abbreviated expert consensus statement (ECS) intended to focus primarily on the indications for CIEDs in the setting of specific disease/diagnostic categories. This document will also provide guidance regarding the management of lead systems and follow-up evaluation for pediatric patients with CIEDs. The recommendations are presented in an abbreviated modular format, with each section including the complete table of recommendations along with a brief synopsis of supportive text and select references to provide some context for the recommendations. This document is not intended to provide an exhaustive discussion of the basis for each of the recommendations, which are further addressed in the comprehensive PACES-CIED document [3], with further data easily accessible in electronic searches or textbooks.
RESUMO
In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.
RESUMO
INTRODUCTION: Atrial fibrillation (AF) is a very common tachyarrhythmia with increasing prevalence with age, but uncommon in the pediatric population. Understanding that AF increases comorbidities make the need for investigation and potential elimination of alternate etiologies in pediatric AF patients critical. The objective of this study was to review our institutional data and compare our findings with previously documented adult AF risk factors to pediatric patients while also identifying which patients had alternate electrophysiology diagnoses amenable to transcatheter ablation. METHODS: A retrospective chart review was performed identifying AF patients who were less than 21 years old, had no significant congenital cardiovascular anomalies, a documented episode of AF on electrocardiogram and underwent invasive electrophysiology study (EPS). RESULTS: Nineteen patients were identified over a 9-year period of time finding a male predominance (74%), the average age of 14.95 ± 4.17 years, the average weight of 78.5 ± 31.4 kg, and average body mass index of 26.8 ± 6.87 kg/m2 . Preprocedural left atrial volumes made on echocardiograms demonstrated a mean of 33.96 ± 16.35 mL/m2 (Z-scores -0.81 ± 1.50), indicating no dilation. Five of nineteen patients (26%) had additional electrophysiologic diagnoses during EPS, including atrioventricular reentrant tachycardia (n = 2, 10%) and atrioventricular nodal reentrant tachycardia (n = 3, 16%). Four patients underwent successful ablation with no documented or clinical AF recurrence. CONCLUSIONS: Adult risk factors of male predominance and obesity were seen in pediatric AF patients, while left atrial enlargement was not. Twenty-one percent of the pediatric AF patients who had additional electrophysiologic substrates and successful ablations resulted in no further clinical episodes of AF. This suggests that pediatric patients presenting with AF might benefit from an EPS as part of a complete evaluation.
Assuntos
Fibrilação Atrial/diagnóstico , Eletrodiagnóstico , Adolescente , Fatores Etários , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criança , Eletrocardiografia , Fenômenos Eletrofisiológicos , Feminino , Seguimentos , Humanos , Masculino , Obesidade , Estudos Retrospectivos , Fatores de Risco , Fatores SexuaisRESUMO
Photo-reorganization of 3-alkoxy-6-chloro-2-(benzo[b]thiophen-2-yl)-4H-chromen-4-ones in methanol with Pyrex filtered UV-light from a medium pressure 125 W Hg-vapor lamp led to the formation of angular pentacyclic compounds (dihydro and aromatic products) along with some rearranged chromenones where the product(s) distribution depended upon the structure of 3-alkoxy groups (methoxy, ethoxy, allyloxy and benzyloxy). The phenyl moiety in the 3-benzyloxy group had a profound effect on the dihydro product(s) formation as the latter was in high yield when the alkoxy group was benzyloxy followed by allyloxy, ethoxy and methoxy groups. The present photochemical study represents a general method for the synthesis of some angular pentacyclic - benzothiophene fused xanthenone derivatives in a single step without using any specific and toxic reagent. The structures of the new organic scaffolds obtained were established by their spectral data (UV, IR and NMR).
RESUMO
OBJECTIVES: To identify the clinical presentation of children and adolescents affected by 1 of 4 cardiac conditions predisposing to sudden cardiac arrest: hypertrophic cardiomyopathy, long QT syndrome (LQTS), catecholaminergic polymorphic ventricular tachycardia (CPVT), and anomalous origin of the left coronary artery from the right sinus of Valsalva (ALCA-R). STUDY DESIGN: This was a retrospective review of newly diagnosed pediatric patients with hypertrophic cardiomyopathy, LQTS, CPVT, and ALCA-R referred for cardiac evaluation at 6 US centers from 2008 to 2014. RESULTS: A total of 450 patients (257 male/193 female; median age 10.1 years [3.6-13.8 years, 25th-75th percentiles]) were enrolled. Patient age was ≤13 years for 70.4% of the cohort (n = 317). Sudden cardiac arrest was the initial presentation in 7%; others were referred on the basis of abnormal or suspicious family history, personal symptoms, or physical findings. Patients with LQTS and hypertrophic cardiomyopathy were referred most commonly because of family history concerns. ALCA-R was most likely to have abnormal signs or symptoms (eg, exercise chest pain, syncope, or sudden cardiac arrest). Patients with CPVT had a high incidence of syncope and the greatest incidence of sudden cardiac arrest (45%); 77% exhibited exercise syncope or sudden cardiac arrest. This study demonstrated that suspicious or known family history plays a role in identification of many patients ultimately affected by 1 of the 3 genetic disorders (hypertrophic cardiomyopathy, LQTS, CPVT). CONCLUSION: Important patient and family history and physical examination findings may allow medical providers to identify many pediatric patients affected by 4 cardiac disorders predisposing to sudden cardiac arrest.
Assuntos
Parada Cardíaca/diagnóstico , Adolescente , Cardiomiopatia Hipertrófica/complicações , Criança , Pré-Escolar , Anomalias dos Vasos Coronários/complicações , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Feminino , Parada Cardíaca/epidemiologia , Parada Cardíaca/etiologia , Humanos , Síndrome do QT Longo/complicações , Masculino , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/complicaçõesAssuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Criança , Morte Súbita Cardíaca , Eletrônica , Coração , HumanosRESUMO
The phototransformation of some 2-(3-methoxyphenyl)-4H-chromen-4-ones bearing a propynyloxy moiety at the 3-position has been described. On photolysis with pyrex-filtered UV light from a Hg lamp (125 W), these chromenones produced a major amount of 5-ethynyl-2-methoxy-6-oxa-benzo[5,6-c]xanthen-7-ones consisting of an exotic tetracyclic scaffold. These photoproducts have been envisioned to be produced through regioselective ring closure at the 6'-position of the 2-(3'-methoxy)phenyl moiety of the initially formed 1,4-biradical via a γ-H abstraction mechanism. No product whatsoever was observed through ring closure at the 2'-position. This behaviour has been found to be in accordance with the directive influence observed in free radical aromatic substitutions. This regioselective photocyclisation is further supported by calculations made from 3D structures (MM2 program). In addition, during the irradiation of these substrates, 2-(3-methoxyphenyl)-4H-chromen-4-ones were also realised through dealkoxylation. The structures of the substrates and photoproduct(s) have been determined by their spectroscopic (IR, NMR, mass spectrometry) studies.
RESUMO
The synthesis and spectral studies of variously substituted 3-hydroxychromones have been carried out. A key relationship between the structural motif of synthesized 3-hydroxychromones (3-HCs) and their fluorescent properties was found. The chromones substituted with electron-donating group at 4'-position expressed the red shift of the N(*) and T(*) band and also exhibited the increased fluorescent intensity ratio while the chromones with electron-withdrawing group showed the blue shift of the N(*) and T(*) band. Therefore, these 3-HCs may behave as the possible fluorescent probes.
RESUMO
Exposure to ionizing radiation is an inherent occupational health hazard in clinical cardiology. Health risks have been reported previously, including predilection to cancer. In addition, orthopedic injury due to prolonged wearing of heavy protective lead aprons, which are mandatory to reduce radiation risk, have been extensively documented. Cardiology as a specialty has grown with rising volumes of increasingly complex procedures. This includes electrophysiological, coronary, and structural intervention, advanced heart failure/transplant management, and diagnostic imaging. Both the operator as well imaging specialists are exposed to radiation, particularly in structural interventions where interventional cardiologists and structural imagers work closely. Increasingly, women interested in cardiology may deselect the field due to radiation concerns. This expert document highlights the risks of radiation exposure in cardiology, including practical tips within various subspecialty fields such as interventional/structural cardiology, electrophysiology, imaging, advanced heart failure, and pediatric cardiology.
RESUMO
Electrophysiological and interventional procedures have been increasingly used to reduce morbidity and mortality in patients experiencing cardiovascular diseases. Although antithrombotic therapies are critical to reduce the risk of stroke or other thromboembolic events, they can nonetheless increase the bleeding hazard. This is even more true in an aging population undergoing cardiac procedures in which the combination of oral anticoagulants and antiplatelet therapies would further increase the hemorrhagic risk. Hence, the timing, dose, and combination of antithrombotic therapies should be carefully chosen in each case. However, the maze of society guidelines and consensus documents published so far have progressively led to a hazier scenario in this setting. Aim of this review is to provide-in a single document-a quick, evidenced-based practical summary of the antithrombotic approaches used in different cardiac electrophysiology and interventional procedures to guide the busy clinician and the cardiac proceduralist in their everyday practice.
Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Idoso , Fibrinolíticos/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente , Acidente Vascular Cerebral/tratamento farmacológico , Resultado do TratamentoRESUMO
For patients with congenital heart disease (CHD), chronic ventricular pacing may lead to progressive cardiomyopathy owing to electromechanical dyssynchrony. Cardiac conduction system pacing (CSP) has been proposed as a physiologic pacing strategy-directly engaging the His-Purkinje system and preserving electromechanical synchrony. CSP may be indicated for a wide variety of children and adults with CHD and has emerged as an important tool in the armamentarium for cardiac implantable electronic device operators. This review provides the rationale, background, and supportive evidence for CSP in patients with CHD and discusses implant strategies and outcomes in the context of dominant ventricular morphologic categories.
Assuntos
Terapia de Ressincronização Cardíaca , Cardiopatias Congênitas , Insuficiência Cardíaca , Criança , Humanos , Fascículo Atrioventricular , Bloqueio de Ramo , Eletrocardiografia , Cardiopatias Congênitas/terapia , Resultado do Tratamento , Estimulação Cardíaca Artificial , Insuficiência Cardíaca/terapiaRESUMO
Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.
Assuntos
Desfibriladores Implantáveis , Tecnologia de Sensoriamento Remoto , HumanosRESUMO
Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.
RESUMO
Insertable cardiac monitors (ICMs) have undergone advancements in size and functionality over the past decade, resulting in the introduction of small, easily insertable devices capable of long-term remote monitoring. We define first-generation ICMs as implantable cardiac monitoring devices that require an incision and surgical creation of a subcutaneous pocket and second-generation ICMs as devices implanted using a custom-made tool for subcutaneous insertion, respectively. The aim of this study was to understand the differences between first- and second-generation pediatric ICM implants, implant indications, and time to diagnosis. We performed a retrospective, single-center chart review of patients who underwent ICM implantation from 2009-2019, spanning a 5-year course of first-generation ICM implantations and 5-year course of second-generation ICM implantations. Demographic data, past medical history, implant indication, and time to diagnosis were obtained. A total of 208 patients were identified over the 10-year time period, including 38 (18%) who underwent implantation with a first-generation device and 170 (82%) who underwent implantation with a second-generation device. Implant indications for first-generation ICMs included syncope (71%), palpitations (16%), inherited arrhythmia syndrome (IAS) management (5%), and premature ventricular contractions/ventricular tachycardia (VT) (8%); implant indications for second-generation ICMs included syncope (48%), palpitations (19%), IAS management (40%), premature ventricular contractions/VT (11%), atrial fibrillation (2%), tachycardia (3%), and heart block (0.5%). The average time to diagnosis was 38 weeks for patients with first-generation devices and 55 weeks for those with second-generation devices. With innovations in ICM technologies, there are expanding indications for ICM implantation in pediatric patients for long-term monitoring, specifically regarding the management of IAS patients.
RESUMO
BACKGROUND: Recent technologic advances have resulted in increased development and utilization of direct-to-consumer cardiac wearable devices with various functionality. This study aimed to assess Apple Watch Series 6 (AW6) pulse oximetry and electrocardiography (ECG) in a cohort of pediatric patients. METHODS: This single-center, prospective study enrolled pediatric patients ≥ 3kg and having an ECG and/or pulse oximetry (SpO2) as part of their planned evaluation. Exclusion criteria: 1) non-English speaking patients and 2) patients in state custody. Simultaneous tracings were obtained for SpO2 and ECG with concurrent standard pulse oximeter and 12-lead ECG. AW6 automated rhythm interpretations were compared to physician over-read and categorized as accurate, accurate with missed findings, inconclusive (automated interpretation: "inconclusive"), or inaccurate. RESULTS: A total of 84 patients were enrolled over a 5-week period. 68 patients (81%) were placed into the SpO2 and ECG arm, with 16 patients (19%) placed into the SpO2 only arm. Pulse oximetry data was successfully collected in 71/84 (85%) patients and ECG data in 61/68 (90%). ΔSpO2 between modalities was 2.0±2.6% (r = 0.76). ΔRR was 43±44msec (r = 0.96), ΔPR 19±23msec (r = 0.79), ΔQRS 12±13msec (r = 0.78), and ΔQT 20±19msec (r = 0.9). The AW6 automated rhythm analysis yielded a 75% specificity and found: 1) 40/61 (65.6%) "accurate", 2) 6/61 (9.8%) "accurate with missed findings", 3) 14/61 (23%) "inconclusive", and 4) 1/61 (1.6%) incorrect. CONCLUSION: The AW6 can accurately measure oxygen saturation when compared to hospital pulse oximeters in pediatric patients and provide good quality single lead ECGs that allow for accurate measurement of RR, PR, QRS, and QT intervals with manual interpretation. The AW6-automated rhythm interpretation algorithm has limitations for smaller pediatric patients and patients with abnormal ECGs.