Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am J Gastroenterol ; 119(3): 438-449, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38857483

RESUMO

Gastrointestinal (GI) bleeding is the most common GI diagnosis leading to hospitalization within the United States. Prompt diagnosis and treatment of GI bleeding is critical to improving patient outcomes and reducing high healthcare utilization and costs. Radiologic techniques including computed tomography angiography, catheter angiography, computed tomography enterography, magnetic resonance enterography, nuclear medicine red blood cell scan, and technetium-99m pertechnetate scintigraphy (Meckel scan) are frequently used to evaluate patients with GI bleeding and are complementary to GI endoscopy. However, multiple management guidelines exist which differ in the recommended utilization of these radiologic examinations. This variability can lead to confusion as to how these tests should be used in the evaluation of GI bleeding. In this document, a panel of experts from the American College of Gastroenterology and Society of Abdominal Radiology provide a review of the radiologic examinations used to evaluate for GI bleeding including nomenclature, technique, performance, advantages, and limitations. A comparison of advantages and limitations relative to endoscopic examinations is also included. Finally, consensus statements and recommendations on technical parameters and utilization of radiologic techniques for GI bleeding are provided.


Assuntos
Hemorragia Gastrointestinal , Humanos , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/diagnóstico , Consenso , Estados Unidos , Gastroenterologia/normas , Sociedades Médicas , Diagnóstico por Imagem/métodos , Diagnóstico por Imagem/normas , Endoscopia Gastrointestinal
2.
Radiology ; 310(3): e232298, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38441091

RESUMO

Gastrointestinal (GI) bleeding is the most common GI diagnosis leading to hospitalization within the United States. Prompt diagnosis and treatment of GI bleeding is critical to improving patient outcomes and reducing high health care utilization and costs. Radiologic techniques including CT angiography, catheter angiography, CT enterography, MR enterography, nuclear medicine red blood cell scan, and technetium-99m pertechnetate scintigraphy (Meckel scan) are frequently used to evaluate patients with GI bleeding and are complementary to GI endoscopy. However, multiple management guidelines exist, which differ in the recommended utilization of these radiologic examinations. This variability can lead to confusion as to how these tests should be used in the evaluation of GI bleeding. In this document, a panel of experts from the American College of Gastroenterology and Society of Abdominal Radiology provide a review of the radiologic examinations used to evaluate for GI bleeding including nomenclature, technique, performance, advantages, and limitations. A comparison of advantages and limitations relative to endoscopic examinations is also included. Finally, consensus statements and recommendations on technical parameters and utilization of radiologic techniques for GI bleeding are provided. © Radiological Society of North America and the American College of Gastroenterology, 2024. Supplemental material is available for this article. This article is being published concurrently in American Journal of Gastroenterology and Radiology. The articles are identical except for minor stylistic and spelling differences in keeping with each journal's style. Citations from either journal can be used when citing this article. See also the editorial by Lockhart in this issue.


Assuntos
Hemorragia Gastrointestinal , Radiologia , Humanos , Hemorragia Gastrointestinal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia , Catéteres
3.
AJR Am J Roentgenol ; 222(2): e2330422, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38054957

RESUMO

MR enterography (MRE) protocols used in patients with Crohn disease are burdened by long acquisition time, high cost, and suboptimal patient experience. For several indications, highly diagnostic MRE can be performed in five or fewer sequences, without IV contrast material or antiperistaltic medication and with an examination room time of less than 12 minutes. As such, MRE could be more patient friendly, more frequently performed, and require fewer health care resources.


Assuntos
Doença de Crohn , Humanos , Doença de Crohn/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Meios de Contraste
4.
J Comput Assist Tomogr ; 48(2): 251-256, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38013203

RESUMO

PURPOSE: This study aimed to compare the image quality of portal venous phase-derived virtual noncontrast (VNC) images from photon-counting computed tomography (PCCT) with energy-integrating dual-energy computed tomography (EI-DECT) in the same patient using quantitative and qualitative analyses. METHODS: Consecutive patients retrospectively identified with available portal venous phase-derived VNC images from both PCCT and EI-DECT were included. Patients without available VNC in picture archiving and communication system in PCCT or prior EI-DECT and non-portal venous phase acquisitions were excluded. Three fellowship-trained radiologists blinded to VNC source qualitatively assessed VNC images on a 5-point scale for overall image quality, image noise, small structure delineation, noise texture, artifacts, and degree of iodine removal. Quantitative assessment used region-of-interest measurements within the aorta at 4 standard locations, both psoas muscles, both renal cortices, spleen, retroperitoneal fat, and inferior vena cava. Attenuation (Hounsfield unit), quantitative noise (Hounsfield unit SD), contrast-to-noise ratio (CNR) (CNR vascular , CNR kidney , CNR spleen , CNR fat ), signal-to-noise ratio (SNR) (SNR vascular , SNR kidney , SNR spleen , SNR fat ), and radiation dose were compared between PCCT and EI-DECT with the Wilcoxon signed rank test. A P < 0.05 indicated statistical significance. RESULTS: A total of 74 patients (27 men; mean ± SD age, 63 ± 13 years) were included. Computed tomography dose index volumes for PCCT and EI-DECT were 9.2 ± 3.5 mGy and 9.4 ± 9.0 mGy, respectively ( P = 0.06). Qualitatively, PCCT VNC images had better overall image quality, image noise, small structure delineation, noise texture, and fewer artifacts (all P < 0.00001). Virtual noncontrast images from PCCT had lower attenuation (all P < 0.05), noise ( P = 0.006), and higher CNR ( P < 0.0001-0.04). Contrast-enhanced structures had lower SNR on PCCT ( P = 0.001, 0.002), reflecting greater contrast removal. The SNRfat (nonenhancing) was higher for PCCT than EI-DECT ( P < 0.00001). CONCLUSIONS: Virtual noncontrast images from PCCT had improved image quality, lower noise, improved CNR and SNR compared with those derived from EI-DECT.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído , Aorta , Rim , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
5.
J Comput Assist Tomogr ; 48(5): 675-682, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38595174

RESUMO

OBJECTIVE: The aim of this study was to compare portal venous phase photon-counting CT (PCCT) using 20 cc less than weight-based contrast dosing with energy-integrating detector CT (EID-CT) using weight-based dosing by quantitative and qualitative analysis. METHODS: Fifty adult patients who underwent a reduced intravenous contrast dose portal venous phase PCCT from May 1, 2023, to August 10, 2023, and a prior portal-venous EID-CT with weight-based contrast dosing were retrospectively identified. Hounsfield units (HU) and noise (SD of HU) were obtained from region-of-interest measurements on 70-keV PCCT and EID-CT in 4 hepatic segments, the main and right portal vein, and both paraspinal muscles. Signal-to-noise and contrast-to-noise ratios were computed. Three abdominal radiologists qualitatively assessed overall image quality, hepatic enhancement, and confidence for metastasis identification on 5-point Likert scales. Readers also recorded the presence/absence of hepatic metastases. Quantitative variables were compared with paired t tests, and multiple comparisons were accounted for with a Bonferroni-adjusted α level of .0016. Ordinal logistic regression was used to evaluate qualitative assessments. Interreader agreement for hepatic metastases was calculated using Fleiss' κ. RESULTS: Fifty patients (32 women; mean [SD] age, 64 [13] years) were included. There was no significant difference in hepatic HU, portal vein HU, noise, and signal-to-noise or contrast-to-noise ratio between reduced contrast dose portal venous phase PCCT versus EID-CT (all P s > 0.0016). Image quality, degree of hepatic enhancement, and confidence for metastasis identification were not different for reduced dose PCCT 70-keV images and EID-CT ( P = 0.06-0.69). κ Value for metastasis identification was 0.86 (95% confidence interval, 0.70-1.00) with PCCT and 0.78 (95% confidence interval, 0.59-0.98) with EID-CT. CONCLUSION: Reduced intravenous contrast portal venous phase PCCT 70-keV images had similar attenuation and image quality as EID-CT with weight-based dosing. Metastases were identified with near-perfect agreement in reduced dose PCCT 70-keV images.


Assuntos
Meios de Contraste , Veia Porta , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Meios de Contraste/administração & dosagem , Veia Porta/diagnóstico por imagem , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Adulto , Idoso de 80 Anos ou mais , Razão Sinal-Ruído , Fótons
6.
Ann Plast Surg ; 92(1): 68-74, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38117047

RESUMO

INTRODUCTION: The purpose of this study was to evaluate the role of body mass index (BMI) in predicting postoperative complications following myocutaneous free flap transfer. In addition, we sought to identify certain body composition variables that may be used to stratify patients into low- versus high-risk for gracilis myocutaneous free flap with skin paddle failure. METHODS: Using the National Surgical Quality Improvement Program database, we collected data for all patients who underwent myocutaneous free flap transfer from 2015 to 2021. Demographic data, medical history, surgical characteristics, and postoperative outcomes, including complications, reoperations, and readmissions, were collected. Body mass index was correlated with outcome measures to determine its role in predicting myocutaneous free flap reliability. Subsequently, we retrospectively obtained measurements of perigracilis anatomy in patients who underwent computed tomography angiography bilateral lower extremity scans with intravenous contrast at our institution. We compared body composition data with mathematical equations calculating the potential area along the skin of the thigh within which the gracilis perforator may be found. RESULTS: Across the United States, 1549 patients underwent myocutaneous free flap transfer over the 7-year study period. Being in obesity class III (BMI ≥40 kg/m2) was associated with a 4-times greater risk of flap complications necessitating a return to the operating room compared with being within the normal BMI range. In our computed tomography angiography analysis, average perigracilis adipose thickness was 18.3 ± 8.0 mm. Adipose thickness had a strong, positive exponential relationship with the area of skin within which the perforator may be found. CONCLUSIONS: In our study, higher BMI was associated with decreased myocutaneous free flap reliability. Specifically, inner thigh adipose thickness can be used to estimate the area along the skin within which the gracilis perforator may be found. This variable, along with BMI, can be used to identify patients who are considered high-risk for flap failure and who may benefit from additional postoperative monitoring, such as the use of a color flow Doppler probe and more frequent and prolonged skin paddle monitoring.


Assuntos
Retalhos de Tecido Biológico , Mamoplastia , Retalho Miocutâneo , Retalho Perfurante , Humanos , Retalhos de Tecido Biológico/efeitos adversos , Índice de Massa Corporal , Estudos Retrospectivos , Reprodutibilidade dos Testes , Mamoplastia/métodos , Retalho Miocutâneo/transplante , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Obesidade/complicações , Obesidade/cirurgia , Algoritmos , Retalho Perfurante/cirurgia
7.
Radiographics ; 43(6): e220192, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37167088

RESUMO

Gastrointestinal (GI) bleeding is a potentially life-threatening condition accounting for more than 300 000 annual hospitalizations. Multidetector abdominopelvic CT angiography is commonly used in the evaluation of patients with GI bleeding. Given that many patients with severe overt GI bleeding are unlikely to tolerate bowel preparation, and inpatient colonoscopy is frequently limited by suboptimal preparation obscuring mucosal visibility, CT angiography is recommended as a first-line diagnostic test in patients with severe hematochezia to localize a source of bleeding. Assessment of these patients with conventional single-energy CT systems typically requires the performance of a noncontrast series followed by imaging during multiple postcontrast phases. Dual-energy CT (DECT) offers several potential advantages for performing these examinations. DECT may eliminate the need for a noncontrast acquisition by allowing the creation of virtual noncontrast (VNC) images from contrast-enhanced data, affording significant radiation dose reduction while maintaining diagnostic accuracy. VNC images can help radiologists to differentiate active bleeding, hyperattenuating enteric contents, hematomas, and enhancing masses. Additional postprocessing techniques such as low-kiloelectron voltage virtual monoenergetic images, iodine maps, and iodine overlay images can increase the conspicuity of contrast material extravasation and improve the visibility of subtle causes of GI bleeding, thereby increasing diagnostic confidence and assisting with problem solving. GI bleeding can also be diagnosed with routine single-phase DECT scans by constructing VNC images and iodine maps. Radiologists should also be aware of the potential pitfalls and limitations of DECT. ©RSNA, 2023 Quiz questions for this article are available through the Online Learning Center.


Assuntos
Hemorragia Gastrointestinal , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Humanos , Hemorragia Gastrointestinal/diagnóstico por imagem , Intestino Delgado , Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos
8.
Clin Gastroenterol Hepatol ; 20(10): 2327-2336.e4, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34968729

RESUMO

BACKGROUND & AIMS: Postoperative Crohn's disease (CD) surveillance relies on endoscopic monitoring. The role of cross-sectional imaging is less clear. We evaluated the concordance of cross-sectional enterography with endoscopic recurrence and the predictive ability of radiography for future CD postoperative recurrence. METHODS: We performed a multi-institution retrospective cohort study of postoperative adult patients with CD who underwent ileocolonoscopy and cross-sectional enterography within 90 days of each other following ileocecal resection. Imaging studies were interpreted by blinded, expert CD radiologists. Patients were categorized by presence of endoscopic postoperative recurrence (E+) (modified Rutgeerts' score ≥i2b) or radiographic disease activity (R+) and grouped by concordance status. RESULTS: A total of 216 patients with CD with paired ileocolonoscopy and imaging were included. A majority (54.2%) exhibited concordance (34.7% E+/R+; 19.4% E-/R-) between studies. The plurality (41.7%; n = 90) were E-/R+ discordant. Imaging was highly sensitive (89.3%), with low specificity (31.8%), in detecting endoscopic postoperative recurrence. Intestinal wall thickening, luminal narrowing, mural hyper-enhancement, and length of disease on imaging were associated with endoscopic recurrence (all P < .01). Radiographic disease severity was associated with increasing Rutgeerts' score (P < .001). E-/R+ patients experienced more rapid subsequent endoscopic recurrence (hazard ratio, 4.16; P = .033) and increased rates of subsequent endoscopic (43.8% vs 22.7%) and surgical recurrence (20% vs 9.5%) than E-/R- patients (median follow-up, 4.5 years). CONCLUSIONS: Cross-sectional imaging is highly sensitive, but poorly specific, in detecting endoscopic disease activity and postoperative recurrence. Advanced radiographic disease correlates with endoscopic severity. Patients with radiographic activity in the absence of endoscopic recurrence may be at increased risk for future recurrence, and closer monitoring should be considered.


Assuntos
Doença de Crohn , Adulto , Colo/cirurgia , Colonoscopia/métodos , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/cirurgia , Humanos , Íleo/cirurgia , Recidiva , Estudos Retrospectivos
9.
Radiology ; 301(1): 144-151, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34342502

RESUMO

Background Dual-energy CT enterography (DECTE) has been shown to be useful in characterizing Crohn disease activity compared with clinical markers of inflammation but, to the knowledge of the authors, comparison has not been made with histopathologic specimens. Purpose To compare mucosal iodine density obtained at DECTE from Crohn disease-affected bowel with histopathologic specimens from surgically resected ileocolectomy bowel segments or terminal ileum colonoscopic biopsies in the same patients. Materials and Methods This was a retrospective study. Bowel segments in adults with Crohn disease who underwent DECTE from January 2017 to April 2019 within 90 days of ileocolectomy or colonoscopy were retrospectively evaluated with prototype software allowing the semiautomatic determination of inner hyperdense bowel wall (mucosal) mean iodine density, normalized to the aorta. Mean normalized iodine density and clinical activity indexes (Crohn Disease Activity Index [CDAI] and Harvey-Bradshaw Index [HBI]) were compared with histologic active inflammation grades by using two-tailed t tests. Receiver operating characteristic curves were generated for mean normalized iodine density, CDAI, and HBI to determine sensitivity, specificity, and accuracy. A P value less than .05 was considered to indicate statistical significance. Results The following 16 patients were evaluated (mean age, 41 years ± 14 [standard deviation]): 10 patients (five men, five women; mean age, 41 years ± 15) with 19 surgical resection specimens and six patients with terminal ileum colonoscopic mucosal biopsies (four men, two women; mean age, 43 years ± 14). Mean normalized iodine density was 16.5% ± 5.7 for bowel segments with no active inflammation (n = 8) and 34.7% ± 9.7 for segments with any active inflammation (n = 17; P < .001). A 20% mean normalized iodine density threshold had sensitivity, specificity, and accuracy of 17 of 17 (100%; 95% CI: 80.5, 100), six of eight (75%; 95% CI: 35, 97), and 23 of 25 (92%; 95% CI: 74, 99), respectively, for active inflammation. Clinical indexes were similar for patients with and without active inflammation at histopathologic analysis (CDAI score, 261 vs 251, respectively [P = .77]; HBI score, 7.8 vs 6.4, respectively [P = .36]). Conclusion Iodine density from dual-energy CT enterography may be used as a radiologic marker of Crohn disease activity as correlated with histopathologic analysis. © RSNA, 2021 See also the editorial by Ohliger in this issue.


Assuntos
Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Inflamação/diagnóstico por imagem , Inflamação/patologia , Iodo/farmacocinética , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Biomarcadores , Meios de Contraste/farmacocinética , Doença de Crohn/complicações , Feminino , Humanos , Inflamação/etiologia , Intestinos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
10.
AJR Am J Roentgenol ; 216(1): 104-105, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32603220

RESUMO

The purpose of this article is to describe arterial and venous thromboembolism in the abdomen, pelvis, and lower extremities in patients with coronavirus disease (COVID-19). Eighty-two patients with COVID-19 who underwent abdominal ultrasound or CT were retrospectively compared with 82 patients without COVID-19 for thromboembolism and solid-organ infarction. Nine (11%) patients with COVID-19 had thromboembolic findings, with medium to large arterial thrombi in five. One patient without COVID-19 had known portal vein thrombus on CT. Thromboembolic findings occurred more frequently in patients with than without COVID-19 (p = 0.02).


Assuntos
COVID-19/complicações , Tromboembolia/diagnóstico por imagem , Tromboembolia/etiologia , Trombofilia , Abdome/irrigação sanguínea , Idoso , Feminino , Humanos , Extremidade Inferior/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , New York , Pelve/irrigação sanguínea , Estudos Retrospectivos , SARS-CoV-2 , Tomografia Computadorizada por Raios X , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA