Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Neurosurg Spine ; 22(1): 15-25, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25380538

RESUMO

OBJECT: The purpose of this study was to evaluate the safety and effectiveness of 2-level total disc replacement (TDR) using a Mobi-C cervical artificial disc at 48 months' follow-up. METHODS: A prospective randomized, US FDA investigational device exemption pivotal trial of the Mobi-C cervical artificial disc was conducted at 24 centers in the U.S. Three hundred thirty patients with degenerative disc disease were randomized and treated with cervical total disc replacement (225 patients) or the control treatment, anterior cervical discectomy and fusion (ACDF) (105 patients). Patients were followed up at regular intervals for 4 years after surgery. RESULTS: At 48 months, both groups demonstrated improvement in clinical outcome measures and a comparable safety profile. Data were available for 202 TDR patients and 89 ACDF patients in calculation of the primary endpoint. TDR patients had statistically significantly greater improvement than ACDF patients for the following outcome measures compared with baseline: Neck Disability Index scores, 12-Item Short Form Health Survey Physical Component Summary scores, patient satisfaction, and overall success. ACDF patients experienced higher subsequent surgery rates and displayed a higher rate of adjacent-segment degeneration as seen on radiographs. Overall, TDR patients maintained segmental range of motion through 48 months with no device failure. CONCLUSIONS: Four-year results from this study continue to support TDR as a safe, effective, and statistically superior alternative to ACDF for the treatment of degenerative disc disease at 2 contiguous cervical levels. Clinical trial registration no.: NCT00389597 ( clinicaltrials.gov ).


Assuntos
Vértebras Cervicais/cirurgia , Discotomia/métodos , Degeneração do Disco Intervertebral/cirurgia , Fusão Vertebral/métodos , Substituição Total de Disco/métodos , Adulto , Vértebras Cervicais/diagnóstico por imagem , Avaliação da Deficiência , Feminino , Seguimentos , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Radiografia , Amplitude de Movimento Articular , Substituição Total de Disco/instrumentação , Resultado do Tratamento
2.
Spine (Phila Pa 1976) ; 40(11): 759-66, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-25785955

RESUMO

STUDY DESIGN: A prospective, randomized, multicenter Food and Drug Administration Investigation Device Exemption study using total disc replacement as surgical treatment of degenerative disc disease at 1 or 2 contiguous levels of the cervical spine. OBJECTIVE: To evaluate the safety and effectiveness of total disc replacement at single or 2 contiguous levels through 48 months of follow-up. SUMMARY OF BACKGROUND DATA: Cervical total disc replacement has been shown to be a safe and effective alternative to anterior cervical discectomy and fusion at 24 months. Its motion-preserving capabilities may avoid accelerating adjacent segment pathology and thereby lower the rate of associated complications. METHODS: Patients were randomized in a 2:1 ratio (total disc replacement [TDR]: anterior cervical discectomy and fusion [ACDF]) at 24 sites. Ultimately, 164 patients received TDR at 1 level and 225 patients received TDR at 2 contiguous levels. An additional 24 patients (15 one-level, 9 two-level) were treated with TDR as training cases.Outcome measures included neck disability index, visual analogue scale neck and arm pain, Short Form 12-item Health Survey (SF-12) Mental Composite Score (MCS) and Physical Composite Score (PCS), range of motion, major complication rates, and secondary surgery rates. Patients received follow-up examinations at regular intervals through 4 years after surgery. RESULTS: Preoperative characteristics were statistically similar for the 1- and 2-level patient groups. Four-year follow-up rates were 83.1% (1-level) and 89.0% (2-level). There was no statistically significant difference between 1- and 2-level TDR groups for all clinical outcome measures. Both TDR groups experienced significant improvement at each follow-up when compared with preoperative scores. One case of migration was reported in the 2-level TDR group. CONCLUSION: A 4-year post hoc comparison of 1- and 2-level TDR patients concurrently enrolled in a 24-center, Food and Drug Administration Investigation Device Exemption clinical trial indicated no statistical differences between groups in clinical outcomes, overall complication rates, and subsequent surgery rates. LEVEL OF EVIDENCE: 1.


Assuntos
Vértebras Cervicais , Degeneração do Disco Intervertebral/cirurgia , Substituição Total de Disco , Vértebras Cervicais/diagnóstico por imagem , Avaliação da Deficiência , Seguimentos , Humanos , Degeneração do Disco Intervertebral/complicações , Degeneração do Disco Intervertebral/fisiopatologia , Cervicalgia/etiologia , Medição da Dor , Satisfação do Paciente , Estudos Prospectivos , Radiculopatia/complicações , Radiografia , Amplitude de Movimento Articular , Reoperação , Método Simples-Cego , Substituição Total de Disco/efeitos adversos , Substituição Total de Disco/instrumentação
4.
Spine (Phila Pa 1976) ; 32(11): 1155-62; discussion 1163, 2007 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-17495770

RESUMO

STUDY DESIGN: A prospective, randomized, multicenter, Food and Drug Administration-regulated Investigational Device Exemption clinical trial. OBJECTIVE: To evaluate the safety and effectiveness of the ProDisc-L (Synthes Spine, West Chester, PA) lumbar total disc replacement compared to circumferential spinal fusion for the treatment of discogenic pain at 1 vertebral level between L3 and S1. SUMMARY OF BACKGROUND DATA: As part of the Investigational Device Exemption clinical trial, favorable single center results of lumbar total disc replacement with the ProDisc-L have been reported previously. METHODS: Two hundred eighty-six (286) patients were treated on protocol. Patients were evaluated before and after surgery, at 6 weeks, 3, 6, 12, 18, and 24 months. Evaluation at each visit included patient self-assessments, physical and neurologic examinations, and radiographic evaluation. RESULTS: Safety of ProDisc-L implantation was demonstrated with 0% major complications. At 24 months, 91.8% of investigational and 84.5% of control patients reported improvement in the Oswestry Low Back Pain Disability Questionnaire (Oswestry Disability Index [ODI]) from preoperative levels, and 77.2% of investigational and 64.8% of control patients met the > or =15% Oswestry Disability Index improvement criteria. Overall neurologic success in the investigational group was superior to the control group (91.2% investigational and 81.4% control; P = 0.0341). At 6 weeks and 3 months follow-up time points, the ProDisc-L patients recorded SF-36 Health Survey scores significantly higher than the control group (P = 0.018, P = 0.0036, respectively). The visual analog scale pain assessment showed statistically significant improvement from preoperative levels regardless of treatment (P < 0.0001). Visual analog scale patient satisfaction at 24 months showed a statistically significant difference favoring investigational patients over the control group (P = 0.015). Radiographic range of motion was maintained within a normal functional range in 93.7% of investigational patients and averaged 7.7 degrees. CONCLUSIONS: ProDisc-L has been found to be safe and efficacious. In properly chosen patients, ProDisc-L has been shown to be superior to circumferential fusion by multiple clinical criteria.


Assuntos
Artroplastia de Substituição/instrumentação , Disco Intervertebral/cirurgia , Dor Lombar/etiologia , Vértebras Lombares , Doenças da Coluna Vertebral/cirurgia , Fusão Vertebral , Adulto , Artroplastia de Substituição/efeitos adversos , Aprovação de Equipamentos , Avaliação da Deficiência , Feminino , Seguimentos , Humanos , Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/fisiopatologia , Dor Lombar/tratamento farmacológico , Dor Lombar/cirurgia , Masculino , Pessoa de Meia-Idade , Entorpecentes/uso terapêutico , Medição da Dor , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Doenças da Coluna Vertebral/complicações , Doenças da Coluna Vertebral/diagnóstico por imagem , Doenças da Coluna Vertebral/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , United States Food and Drug Administration
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA