Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Acta Crystallogr D Biol Crystallogr ; 71(Pt 1): 76-85, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25615862

RESUMO

Logging experiments with the laboratory-information management system ISPyB (Information System for Protein crystallography Beamlines) enhances the automation of small-angle X-ray scattering of biological macromolecules in solution (BioSAXS) experiments. The ISPyB interface provides immediate user-oriented online feedback and enables data cross-checking and downstream analysis. To optimize data quality and completeness, ISPyBB (ISPyB for BioSAXS) makes it simple for users to compare the results from new measurements with previous acquisitions from the same day or earlier experiments in order to maximize the ability to collect all data required in a single synchrotron visit. The graphical user interface (GUI) of ISPyBB has been designed to guide users in the preparation of an experiment. The input of sample information and the ability to outline the experimental aims in advance provides feedback on the number of measurements required, calculation of expected sample volumes and time needed to collect the data: all of this information aids the users to better prepare for their trip to the synchrotron. A prototype version of the ISPyBB database is now available at the European Synchrotron Radiation Facility (ESRF) beamline BM29 and is already greatly appreciated by academic users and industrial clients. It will soon be available at the PETRA III beamline P12 and the Diamond Light Source beamlines I22 and B21.


Assuntos
Espalhamento a Baixo Ângulo , Interface Usuário-Computador , Automação , Gráficos por Computador , Modelos Teóricos , Síncrotrons
2.
J Synchrotron Radiat ; 22(6): 1540-7, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26524320

RESUMO

MASSIF-1 (ID30A-1) is an ESRF undulator beamline operating at a fixed wavelength of 0.969 Å (12.8 keV) that is dedicated to the completely automatic characterization of and data collection from crystals of biological macromolecules. The first of the ESRF Upgrade MASSIF beamlines to be commissioned, it has been open since September 2014, providing a unique automated data collection service to academic and industrial users. Here, the beamline characteristics and details of the new service are outlined.


Assuntos
Cristalização/instrumentação , Cristalografia por Raios X/instrumentação , Armazenamento e Recuperação da Informação/métodos , Complexos Multiproteicos/química , Complexos Multiproteicos/ultraestrutura , Síncrotrons/instrumentação , Algoritmos , Biopolímeros/química , Desenho de Equipamento , Análise de Falha de Equipamento , Robótica/instrumentação
3.
Bioinformatics ; 27(22): 3186-92, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21949273

RESUMO

MOTIVATION: Individual research groups now analyze thousands of samples per year at synchrotron macromolecular crystallography (MX) resources. The efficient management of experimental data is thus essential if the best possible experiments are to be performed and the best possible data used in downstream processes in structure determination pipelines. Information System for Protein crystallography Beamlines (ISPyB), a Laboratory Information Management System (LIMS) with an underlying data model allowing for the integration of analyses down-stream of the data collection experiment was developed to facilitate such data management. RESULTS: ISPyB is now a multisite, generic LIMS for synchrotron-based MX experiments. Its initial functionality has been enhanced to include improved sample tracking and reporting of experimental protocols, the direct ranking of the diffraction characteristics of individual samples and the archiving of raw data and results from ancillary experiments and post-experiment data processing protocols. This latter feature paves the way for ISPyB to play a central role in future macromolecular structure solution pipelines and validates the application of the approach used in ISPyB to other experimental techniques, such as biological solution Small Angle X-ray Scattering and spectroscopy, which have similar sample tracking and data handling requirements.


Assuntos
Cristalografia por Raios X/métodos , Sistemas de Informação Administrativa , Proteínas/química , Síncrotrons , Cristalografia por Raios X/instrumentação , Coleta de Dados , Substâncias Macromoleculares/química , Difração de Raios X
4.
Prog Biophys Mol Biol ; 89(2): 124-52, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15910915

RESUMO

The production of three-dimensional crystallographic structural information of macromolecules can now be thought of as a pipeline which is being streamlined at every stage from protein cloning, expression and purification, through crystallisation to data collection and structure solution. Synchrotron X-ray beamlines are a key section of this pipeline as it is at these that the X-ray diffraction data that ultimately leads to the elucidation of macromolecular structures are collected. The burgeoning number of macromolecular crystallography (MX) beamlines available worldwide may be enhanced significantly with the automation of both their operation and of the experiments carried out on them. This paper reviews the current situation and provides a glimpse of how a MX beamline may look in the not too distant future.


Assuntos
Cristalografia por Raios X , Proteínas/química , Software , Conformação Proteica , Análise Espectral/instrumentação , Análise Espectral/métodos , Síncrotrons/instrumentação
5.
J Appl Crystallogr ; 46(Pt 3): 804-810, 2013 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-23682196

RESUMO

The development of automated high-intensity macromolecular crystallography (MX) beamlines at synchrotron facilities has resulted in a remarkable increase in sample throughput. Developments in X-ray detector technology now mean that complete X-ray diffraction datasets can be collected in less than one minute. Such high-speed collection, and the volumes of data that it produces, often make it difficult for even the most experienced users to cope with the deluge. However, the careful reduction of data during experimental sessions is often necessary for the success of a particular project or as an aid in decision making for subsequent experiments. Automated data reduction pipelines provide a fast and reliable alternative to user-initiated processing at the beamline. In order to provide such a pipeline for the MX user community of the European Synchrotron Radiation Facility (ESRF), a system for the rapid automatic processing of MX diffraction data from single and multiple positions on a single or multiple crystals has been developed. Standard integration and data analysis programs have been incorporated into the ESRF data collection, storage and computing environment, with the final results stored and displayed in an intuitive manner in the ISPyB (information system for protein crystallography beamlines) database, from which they are also available for download. In some cases, experimental phase information can be automatically determined from the processed data. Here, the system is described in detail.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA