Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 168
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
J Esthet Restor Dent ; 36(2): 303-323, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37571973

RESUMO

OBJECTIVE: To assess and compare, through a systematic review of the literature, the biomechanical performance of endocrowns and traditional core-crowns (with and without intracanal post) for the rehabilitation of endodontically treated teeth with severe coronal structure damage. MATERIALS AND METHODS: A systematic search was performed in MEDLINE/PubMed, Scopus, and Web of Science databases. In-vitro studies comparing endocrowns with (post-)core-crown restorations were selected and screened by two independent reviewers. The included studies were submitted to the risk of bias analysis using the RoBDEMAT tool and the biomechanical outcomes were collected for qualitative analysis. The extracted data were presented based on comparative analyses among the included studies. RESULTS: Thirty-one studies were included: 9 studies evaluated restorations of molars, 14 for premolars, and 8 studies evaluated anterior restorations. For the majority of the studies, endocrowns showed either similar or greater survival rates under fatigue and monotonic load than (post-)core-crown restorations, irrespectively of the tooth. The endocrowns showed more favorable failure patterns than (post-)core-crowns, irrespectively of the tooth. Endocrowns produced lower stresses in the restorative material for molars and premolars and in the luting material for premolars than (post-)core-crown restorations. The included studies presented adequate information for most items of the RoBDEMAT risk of bias tool. CONCLUSION: Endocrowns showed similar or greater biomechanical performance than the traditional (post-)core-crown restorations in most of the evaluated studies. CLINICAL SIGNIFICANCE: This systematic review showed that endocrowns present either similar or greater biomechanical performance than core-crown restorations for anterior and posterior endodontically treated teeth with severe structural damage.


Assuntos
Coroas , Dente não Vital , Humanos , Materiais Dentários , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Dente não Vital/terapia , Prostodontia/métodos
2.
J Esthet Restor Dent ; 36(3): 469-476, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37861306

RESUMO

OBJECTIVES: Determine visual 50:50% color difference acceptability thresholds (AT) for regions of the dental color space with varying chromaticity. METHODS: A 40-observer panel belonging to two different groups (dentists and laypersons) evaluated 144 dental resin composites pairs (divided in three different sets of 48 pairs according to chroma value: Low Chroma (LC), Medium Chroma (MC) and High Chroma (HC) placed 40 cm away and inside of a viewing cabinet (D65 Standard light source; diffuse/0° geometry). A Takagi-Sugeno-Kang (TSK) fuzzy approximation was used for fitting the data points and calculate the 50:50% acceptability thresholds in CIEDE2000. A paired t-test was used to evaluate the statistical significance between thresholds differences and Bonferroni correction was applied. RESULTS: The CIEDE2000 50:50% AT were ∆E00 = 2.84, ∆E00 = 2.31 and ∆E00 = 1.80 for LC, MC and HC sets of sample pairs, respectively. The 50:50% AT values were statistically significant between the different sets of sample pairs, as well as the 50:50% AT values obtained for different observer groups. CONCLUSIONS: 50:50% CIEDE2000 acceptability thresholds for dentistry are significantly different depending on the chromaticity of the samples. Observers show higher acceptability for more achromatic samples (low chroma value) than for more chromatic samples. CLINICAL SIGNIFICANCE: The difference in the AT for distinct regions of the dental color space can assist professionals as a quality control tool to assess clinical performance and interpret visual and instrumental findings in clinical dentistry, dental research, and subsequent standardization processes.


Assuntos
Odontologia , Pigmentação em Prótese , Cor , Controle de Qualidade
3.
Clin Oral Investig ; 27(6): 2465-2481, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37017759

RESUMO

OBJECTIVES: The aim of this review to overview three-dimensional (3D) printing technologies available for different dental disciplines, considering the applicability of such technologies and materials development. MATERIALS AND METHODS: Source Arksey and O'Malley's five stages framework using PubMed, EMBASE, and Scopus (Elsevier) databases managed this review. Papers focusing on 3D printing in dentistry and written in English were screened. Scientific productivity by the number of publications, areas of interest, and the focus of the investigations in each dental discipline were extracted. RESULTS: Nine hundred thirty-four studies using 3D printing in dentistry were assessed. Limited clinical trials were observed, especially in Restorative, endodontics, and pediatric dentistry. Laboratory or animal studies are not reliable for clinical success, suggesting that clinical trials are a good approach to validate the new methods' outcomes and ensure that the benefits outweigh the risk. The most common application for 3D printing technologies is to facilitate conventional dental procedures. CONCLUSIONS: The constantly improving quality of 3D printing applications has contributed to increasing the popularity of these technologies in dentistry; however, long-term clinical studies are necessary to assist in defining standards and endorsing the safe application of 3D printing in dental practice. CLINICAL RELEVANCE: The recent progress in 3D materials has improved dental practice capabilities over the last decade. Understanding the current status of 3D printing in dentistry is essential to facilitate translating its applications from laboratory to the clinical setting.


Assuntos
Endodontia , Impressão Tridimensional , Humanos , Odontopediatria , Assistência Odontológica
4.
J Oral Rehabil ; 50(2): 150-156, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36478604

RESUMO

BACKGROUND: Caries and periodontal disease may cause tooth losses and chewing difficulty, especially in the elderly. Ingesting poorly chewed food may delay gastric emptying and favour the development of gastroesophageal reflux disease (GERD). OBJECTIVE: This study investigated the association between masticatory dysfunction and GERD in the elderly from a rural area in southern Brazil. METHODS: This census invited all 489 elderly from a city to participate. The study used a GERD symptoms questionnaire, followed by an oral examination. Masticatory dysfunction was analysed based on the chewing difficulty for some food groups. Tooth loss and chewing self-perception were also considered as exposure variables. Poisson regression determined the association among variables by calculating the prevalence ratio [PR (95% confidence interval)]. RESULTS: The response rate was 93.1% (n = 455, average age of 70.9 years, 50.5% men). The prevalence of GERD in this population was 36.9%. GERD was associated with chewing difficulty for vegetables (PR = 1.54), meats (PR = 1.34) and cereals (PR = 1.43) but not with poor chewing self-perception (PR = 0.80) and tooth loss (PR = 1.22). GERD was also associated with xerostomia (PR = 1.63) and the female gender (PR = 1.35). CONCLUSION: Elderly people from a rural area with a reduced number of teeth present chewing difficulty and a high prevalence of GERD, indicating an association between GERD and masticatory dysfunction.


Assuntos
Cárie Dentária , Refluxo Gastroesofágico , Perda de Dente , Masculino , Humanos , Feminino , Idoso , Perda de Dente/epidemiologia , Refluxo Gastroesofágico/complicações , Refluxo Gastroesofágico/epidemiologia , Mastigação/fisiologia , Inquéritos e Questionários , Cárie Dentária/epidemiologia , Cárie Dentária/complicações , Prevalência
5.
J Esthet Restor Dent ; 35(6): 869-877, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36960913

RESUMO

OBJECTIVES: To evaluate the effect of smoking on tooth whitening and color change after at-home bleaching. MATERIALS AND METHODS: This prospective clinical study evaluated two groups of participants: NS-non-smokers (n = 24) and S-smokers (n = 16). All subjects were treated with at-home bleaching using 22% carbamide peroxide (CP) for 1 h/day for 14 days. Color coordinates (L*-luminosity, a*-red-green axis and b*-yellow-blue axis) were obtained before bleaching (D0-baseline), 1 day (D1), 15 days (D15), and 1 month (D30) after bleaching. The whiteness index (WID ) and CIEDE2000 color differences (ΔE00 ) were calculated for S and NS. Color changes between S and NS subjects for specific teeth (CI-Central Incisors, LI-Lateral Incisors, and C-Canines) were analyzed using the Mann-Whitney test (α = 0.05). RESULTS: There was no significant difference in WID between S and NS subjects at baseline. NS participants showed higher WID than S at D1, D15, and D30 (p < 0.05). NS showed higher ΔWID for CI and C between D0 and the other evaluation times (D1, D15, and D30) compared to S. Smokers showed higher darkening of CI than NS in ΔWID D30-D1 (p < 0.05). Color changes showed similar overall behavior for ΔWID . For all evaluation times, ΔWID and ΔE00 values were below the corresponding acceptability thresholds. CONCLUSION: At-home bleaching was effective on smokers and nonsmokers. Smoking negatively affected color stability after bleaching. ΔE00 and ΔWID were acceptable for both groups. CLINICAL SIGNIFICANCE: Although smoking negatively affected color stability after bleaching, the observed changes were clinically acceptable.


Assuntos
Clareadores Dentários , Clareamento Dental , Fumar , Estudos Prospectivos , Cor , Peróxido de Hidrogênio
6.
J Prosthet Dent ; 129(6): 897-905, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34598771

RESUMO

STATEMENT OF PROBLEM: Evidence is limited for the impact of clinical adjustments and polishing on the longevity of glazed lithium disilicate restorations. PURPOSE: The purpose of this in vitro study was to evaluate the influence of surface finishing on the survival and success rates of lithium disilicate restorations based on fatigue resistance and failure mode. MATERIAL AND METHODS: Lithium disilicate (IPS e.max CAD) maxillary premolar crowns (N=54) were cemented on a dentin analog. The restorations were divided into 3 groups: overglaze (OG), abrasion (GA), and abrasion and polishing (AP). The crowns were submitted to cyclic fatigue in 37 oC water at 100 N and 2 Hz in 2 lifetimes. The load was applied to the occlusal surface by using anatomic pistons to simulate a clinical tripod occlusal contact. After cycling, the crowns were examined for failure (cracking, chipping, or catastrophic fractures) under optical and scanning electron microscopy. Cracking was considered either a structural failure (success analysis) or a survival (clinical criteria - survival analysis). Data were analyzed by using the log rank Kaplan-Meier and Holm-Sidak tests (α=.05). RESULTS: Surface finishing had no influence on the structural integrity of lithium disilicate, with similar success rates (P=.720). The calculated survival rate was higher for AP than that for other groups (P=.028). Cracking was found for GA and AP crowns, mostly initiating from the external surface. Chipping occurred in all experimental groups, and AP crowns did not show catastrophic failures. CONCLUSIONS: Although surface treatments had no influence on the success of lithium disilicate, polishing showed a positive effect on the survival rate of the crowns based on the clinical implications of cracking (no need for replacement).


Assuntos
Porcelana Dentária , Falha de Restauração Dentária , Teste de Materiais , Porcelana Dentária/química , Coroas , Cerâmica/química , Desenho Assistido por Computador
7.
J Prosthet Dent ; 129(6): 931-937, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34482967

RESUMO

STATEMENT OF PROBLEM: The lack of standardization regarding the loading piston material used in fatigue tests could limit the interpretation of study findings. PURPOSE: The purpose of this in vitro study was to evaluate the effect of the piston material on the fatigue behavior of a lithium disilicate glass-ceramic. MATERIAL AND METHODS: Plate-shaped, 1.2-mm-thick, lithium disilicate glass-ceramic specimens were cemented onto a dentin analog substrate with resin cement. The specimens were divided into 4 groups according to the piston material used in the fatigue test (n=30): metal, glass fiber-reinforced epoxy resin, ceramic, and human tooth. The fatigue test was performed in a mechanical cycling machine by using the boundary technique at 2 Hz in distilled water at 37 °C. The fatigue data were analyzed by using the Weibull distribution and a lifetime-inverse power law relationship. Failures were evaluated with fractography and transillumination. RESULTS: The Weibull modulus (ß) was similar among groups. The exponent of crack growth (n) was significantly greater for glass fiber-reinforced epoxy resin and tooth groups than for metal and ceramic; therefore, the probability of failure (Pf) of glass-ceramic specimens loaded by resin and tooth pistons depended more on load amplitude. Specimens tested with tooth showed the highest value of K (characteristic lifetime), which is an indication of greater survival. Radial crack was the only failure mode observed for all experimental groups. CONCLUSIONS: The piston material influenced the fatigue survival of the lithium disilicate glass-ceramic. The glass fiber-reinforced epoxy resin piston closely simulated the fatigue behavior induced by the human tooth on the evaluated glass-ceramic.


Assuntos
Implantes Dentários , Resinas Epóxi , Humanos , Cerâmica/uso terapêutico , Porcelana Dentária , Cimentos de Resina , Teste de Materiais , Análise do Estresse Dentário , Propriedades de Superfície
8.
J Esthet Restor Dent ; 34(6): 988-993, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35142422

RESUMO

OBJECTIVE: To evaluate the accuracy and repeatability of intraoral instruments used for shade determination compared to visual shade selection (VSS). MATERIALS AND METHODS: A total of 20 subjects and 10 observers, balanced by gender, participated in the study. Observers performed VSS of the upper right central incisor from each subject. Instrumental shade determination of the same teeth was performed using a spectrophotometer (Easyshade V) and intraoral scanners (CEREC Omnicam, Primescan, Trios 3 and Trios 4). Vita Classical shade nomenclature was used to record the shade designation for all instruments and VSS. The accuracy of the instruments was determined by comparing the instrument readings with the most frequent visual shade selected. The percentage of accuracy was obtained by comparing the number of agreements with the number of comparisons. The percentage of repeatability was obtained by comparing the number of repeated shades with the number of shade measurements in each group. Accuracy was compared using Cochran Q test followed by pairwise comparisons using multiple McNemar's tests with Bonferroni correction. Repeatability of the instruments was evaluated using Cronbach's alpha. RESULTS: Omnicam showed a significant lower accuracy than the other instruments (p < 0.05). No statistical difference on repeatability was found among the different instruments (p > 0.05). It was not found any statistical differences for VSS accuracy among the observers (p = 0.437) and between genders (p = 0.867). CONCLUSION: Instrumental repeatability (≥75%) and similar accuracy between the best performed instruments (69%-77.5%) and the observers performance (65%-90%) supports the use of high-performance instruments for dental shade determination. CLINICAL SIGNIFICANCE: Most instruments (Easyshade V, Primescan, Trios 3, and Trios 4) showed similar accuracy performance to observers in the VSS.


Assuntos
Incisivo , Pigmentação em Prótese , Cor , Feminino , Humanos , Masculino , Espectrofotometria
9.
J Esthet Restor Dent ; 34(6): 853-864, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35347852

RESUMO

OBJECTIVE: Color and optical properties are particularly crucial to mimic natural tooth. This scoping review aimed to present an overview of the literature published on color and optical properties of 3D printing restorative polymer-based materials. The literature search was performed in MED-LINE/Pubmed, Scopus and Web of Science. MATERIALS AND METHODS: The literature search was conducted in the three databases based on the question: "Are the optical properties and color adequately reported on polymer-based 3D printing dental restorative materials studies?" with no restriction on year of publication. Data were reported and synthesized following PRISMA-ScR statement. RESULTS: Nine studies fit the inclusion criteria. Five studies focused on evaluating only color stability; three articles assessed the color stability along with mechanical and morphological properties and only one study compared color parameters of 3D printed to conventional polymers. Two studies evaluated translucency parameter and no study was found evaluating scattering, absorption, and transmittance. CONCLUSIONS: Color and optical properties of 3D printed polymers that can be used in restorative dentistry are not adequately evaluated and characterized. Future studies on the influence of experimental printing conditions should include these physical properties to assist on improving esthetics. CLINICAL SIGNIFICANCE: This review shows the scarce literature existing on color and optical properties of 3D printing restorative polymer-based materials. These properties and their study are of outmost importance to create materials that mimic natural tooth to allow clinicians to obtain esthetically pleasant restorations.


Assuntos
Estética Dentária , Polímeros , Cor , Odontologia , Impressão Tridimensional
10.
J Esthet Restor Dent ; 34(1): 259-280, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34842324

RESUMO

OBJECTIVE: To perform a comprehensive review of the use of artificial intelligence (AI) and machine learning (ML) in dentistry, providing the community with a broad insight on the different advances that these technologies and tools have produced, paying special attention to the area of esthetic dentistry and color research. MATERIALS AND METHODS: The comprehensive review was conducted in MEDLINE/PubMed, Web of Science, and Scopus databases, for papers published in English language in the last 20 years. RESULTS: Out of 3871 eligible papers, 120 were included for final appraisal. Study methodologies included deep learning (DL; n = 76), fuzzy logic (FL; n = 12), and other ML techniques (n = 32), which were mainly applied to disease identification, image segmentation, image correction, and biomimetic color analysis and modeling. CONCLUSIONS: The insight provided by the present work has reported outstanding results in the design of high-performance decision support systems for the aforementioned areas. The future of digital dentistry goes through the design of integrated approaches providing personalized treatments to patients. In addition, esthetic dentistry can benefit from those advances by developing models allowing a complete characterization of tooth color, enhancing the accuracy of dental restorations. CLINICAL SIGNIFICANCE: The use of AI and ML has an increasing impact on the dental profession and is complementing the development of digital technologies and tools, with a wide application in treatment planning and esthetic dentistry procedures.


Assuntos
Inteligência Artificial , Odontologia , Previsões , Humanos , Aprendizado de Máquina
11.
Orthod Craniofac Res ; 24(3): 379-385, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33259688

RESUMO

OBJECTIVE: To evaluate the effect of the probiotic Lactobacillus brevis CD2 on the prevention of early traumatic oral lesions induced by a fixed orthodontic appliance. SETTINGS AND SAMPLE POPULATION: Twenty orthodontic patients (14-57 yo) were recruited from a private clinic. SUBJECTS AND METHODS: In a phase 2, double-blind clinical trial, all patients were randomly allocated (1:1 ratio) to a 21-day course of soluble tablets containing L brevis CD2 (4 billion colony-forming units after breakfast, lunch and dinner) or placebo, starting at the day of orthodontic appliance placement. The primary outcomes were days with oral lesions and lesion-related pain [ranging between 0 (no pain) and 10 (maximum pain)]. Oral health-related quality of life was measured using OHIP-14 before and after treatments. RESULTS: All patients completed the study. Ten were treated with L brevis (28.1 ± 13.3 yo, 70% women), and 10 received placebo (27.5 ± 9.1 yo, 60% women). The oral lesions lasted significantly less time (P = .018) in patients treated with L brevis (2.5 ± 1.0 days) than with placebo (4.9 ± 3.0 days). Pain score was significantly lower (P = .039) when L brevis was used [median (min-max): 0 (0-4) vs. 3 (0-5)]. OHIP-14 scores were not significantly different between treatments. CONCLUSIONS: Lactobacillus brevis CD2 reduced almost 50% the persistence of traumatic oral lesions in patients with fixed orthodontics. Yet, there was no improvement in quality of life compared to placebo, suggesting that such differences in persistency and pain related to oral lesions may be considered clinically irrelevant.


Assuntos
Levilactobacillus brevis , Probióticos , Método Duplo-Cego , Feminino , Humanos , Masculino , Aparelhos Ortodônticos Fixos , Qualidade de Vida
12.
J Esthet Restor Dent ; 33(6): 844-848, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33227179

RESUMO

OBJECTIVE: To evaluate the accuracy and repeatability of different intraoral scanners on shade determination. MATERIALS AND METHODS: Ten different shades of Vita Mark II blocks were used. A disc-shape specimen (10 mm in diameter and 1 mm thick) per ceramic block was fabricated. Ten color measurements per specimen were performed by each instrument (Vita Easyshade V [control], 3shape Trios, Cerec Omnicam, Cerec Primescan) and recorded in Vita Classic color system. The number of correct shade match per instrument for each shade was recorded. Instrumental accuracy was compared using Cochran Q test and repeatability was analyzed using Cronbach's alpha. RESULTS: There was a significant difference in the instrumental accuracy for shade determination (p < 0.001). There was no statistical difference between the Easyshade V (78%) and the 3Shape Trios (66%) (p > 0.05), with the latter being similar to the other scanners Primescan(63%) and Omnicam (57%) (p > 0.05). No significant difference was found (p > 0.05) when different shades were evaluated by the same instrument. Similar repeatability was found for the different devices, ranging from 44.3% for Easyshade to 51.9% for Omnicam. CONCLUSION: The evaluated instruments showed less than expected repeatability and accuracy on measuring different dental shades. Therefore, caution should be exercised when using instrumental shade determination, which should be accompanied by experienced human visual assessment. CLINICAL SIGNIFICANCE: The outcome of this study might help clinicians evaluate the performance of intraoral scanners as a shade matching tool.


Assuntos
Pigmentação em Prótese , Cor , Humanos , Espectrofotometria
13.
J Esthet Restor Dent ; 33(6): 865-873, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33125179

RESUMO

OBJECTIVE: To evaluate the efficacy of visual discrimination tests used for color research in dentistry. MATERIALS AND METHODS: Volunteers (N = 120) were divided in three groups of observers (n = 40; gender-balanced): S-dental students; D-dentists; and L-laypersons. Two general color discrimination tests (I-Ishihara and FM-Farnsworth-Munsell 100 Hue) and the test of color discrimination competency in dentistry using the VITA Classical shade guide (VC) were performed and data were recorded according to manufacturers' or literature recommendations. Data were statistically analyzed using Mann-Whitney U test for the gender influence and Kruskal-Wallis test for the observer influence, and Bonferroni as post-hoc test (α = 0.05). Pearson (α = 0.05) was used to examine the correlation among visual tests (I, FM, and VC). RESULTS: Observers and visual tests were not influenced by gender (P > .05). Different observer groups had no influence on I test (P > .05). S and D showed similar level of color perception using FM and VC (P > .05), but these observers showed greater color perception than L (P ≤ .05). FM and VC also showed significant correlation (P ≤ .05) for the overall D observers (r = -0.362), male D (r = -0.594) and female S (r = -0.457). CONCLUSION: Observer experience significantly influenced on color perception, irrespective of gender. FM test showed greater correlation to color correspondence in dentistry (VC) than I test. CLINICAL SIGNIFICANCE: Observer experience is more relevant than gender for the color selection process in dentistry. Considering the visual discrimination tests for color research in dentistry, the Farnsworth-Munsell 100 Hue test seems to be more efficacious than the Ishihara test.


Assuntos
Percepção de Cores , Percepção Visual , Cor , Odontologia , Feminino , Humanos , Masculino
14.
J Esthet Restor Dent ; 33(6): 891-898, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-32757249

RESUMO

OBJECTIVE: To evaluate the influence of the substrate and the cement on the final color of ceramic crowns. METHODS: Prosthetic crowns (framework + porcelain) were fabricated using two all-ceramic systems (YZ, 3 mol% yttria-stabilized tetragonal zirconia; IZ, alumina-based zirconia-reinforced glass-infiltrated ceramic) and a metal-ceramic system (MC; n = 8). Metal (M) and resin (R) were used as substrate abutments. For R substrate, crowns were evaluated as seated (R) and after cementation (R-C). CIELAB color coordinates were obtained using a dental spectrophotometer with D65 light illumination. CIELAB, CIEDE2000 (1:1:1) and CIEDE2000 (2:1:1) color difference metrics were used. Data were analyzed using 95% confidence intervals and compared to perceptibility (PT) and acceptability (AT) thresholds. RESULTS: The ∆Eab* , ∆E00 (1 : 1 : 1), and ∆E00 (2 : 1 : 1) values of the restorative systems evaluated using different substrates (M.R) were similar to the AT values of each metric. When non-cemented and cemented crowns were evaluated (R.R-C), MC had color difference values at PT and below AT; while YZ and IZ showed similar values to AT, for ∆Eab* and ∆E00 (1 : 1 : 1) metrics. CONCLUSION: The substrate and cement affected the final color of zirconia-based all-ceramic crowns, but the color differences corresponded to an acceptable match. CLINICAL SIGNIFICANCE: As both substrate and cement influence the final color of multi-layered ceramic prosthesis, dentists and dental technicians should understand the optical properties of dental ceramics to reproduce the natural appearance of dental structures and maximize the chance for excellent color matches.


Assuntos
Materiais Dentários , Zircônio , Cerâmica , Cor , Coroas , Porcelana Dentária , Teste de Materiais
15.
J Esthet Restor Dent ; 33(8): 1118-1131, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34085377

RESUMO

OBJECTIVE: To conduct a systematic review on the masking ability of discolored substrates, analyzing the capacity and quality of the response produced by the different methodologies and techniques applied to overcome this clinical challenge. MATERIALS AND METHODS: The study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The electronic search was conducted in MEDLINE/PubMed, Scopus and Web of Science databases, without date restriction. In vitro studies, written in English, applying different methodologies to evaluate masking ability were included. The variables of interest were: type, color and thickness of the restorative and/or cement material; use of pigments in the restorative material and/or cement; color of the substrate; and background color used for the evaluations. RESULTS: Database search retrieved 307 eligible papers with a final inclusion of 47 published papers. Approximately 98% of the studies used ΔE, 36% used TP, and only 6% used CR to evaluate the masking ability of restorative materials. CONCLUSIONS: The most appropriate methodology to evaluate the masking ability is using color difference equations (ΔE) associated with the perceptibility and acceptability thresholds. CLINICAL SIGNIFICANCE: As different methodologies have been used to evaluate the masking ability of esthetic restorative materials on colored substrates, there is an urgent need to reach a consensus and propose a method, which is suggested by the present systematic review.


Assuntos
Cerâmica , Porcelana Dentária , Cor , Materiais Dentários , Teste de Materiais
16.
Am J Dent ; 33(6): 310-314, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33439560

RESUMO

PURPOSE: To characterize experimental glass fiber-reinforced resin-based composites (GFIR-isophthalic; and GFOR-orthophthalic), evaluating their mechanical behavior and adhesive potential to ceramic in comparison to human dentin and a traditional glass fiber-reinforced epoxy resin (G10). METHODS: Density (ρ), elastic modulus (E), and Poisson's ratio (ν) were evaluated using 2 mm thick specimens from GFIR, GFOR, human dentin and G10. Biaxial flexural strength (δf), Knoop hardness and surface topography under scanning electron microscopy (SEM) were assessed for GFIR and GFOR specimens. G10 was also tested for δf. For the adhesive potential, ceramic specimens (n=10) bonded to GFIR, GFOR or human dentin were tested for microtensile bond strength (MTBS). Disc-shaped ceramics were cemented onto dentin, GFIR, GFOR and G10 (n=15) and loaded to failure. Data were statistically evaluated using Weibull, ANOVA, and Tukey's test (α=0.05). RESULTS: The experimental resins (GFIR and GFOR) showed similar values of HK (53.1 and 52.7 GPa), (ν (0.44 and 0.43) and δf (41.2 MPa and 40.7 MPa). Considering the human dentin values for ρ and E, the corresponding values obtained from GFIR, GFOR and G10 were different, with GFOR values being closer to dentin than GFIR and G10. G10 had statistically greater(δf than GFIR and GFOR. Mean bond strength of ceramic to GFIR, GFOR and dentin were statistically similar. The fracture load of resin-cemented ceramic was influenced by substrate. CLINICAL SIGNIFICANCE: The experimental materials (GFIR and GFOR) showed similar adhesion characteristics to human dentin, however GFOR showed a better potential to be used as a dentin analogue.


Assuntos
Colagem Dentária , Resinas Compostas , Cimentos Dentários , Dentina , Vidro , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
17.
J Esthet Restor Dent ; 32(5): 444-450, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32442351

RESUMO

OBJECTIVE: Ceramic fracture is an undesirable outcome of the rehabilitation with fixed partial dentures (FPD), mainly because it may involve additional cost and clinical time for intraoral repair or replacement of the restoration. This clinical report describes a 5 years survival intraoral repair of a chipped porcelain veneered zirconia framework restoration using a resin-based composite. CLINICAL CONSIDERATIONS: A FPD of porcelain veneered zirconia was made. After 18 months, the FPD presented a porcelain chip (porcelain fracture without exposure to the zirconia structure) on the buccal side of the pontic. An epoxy resin replica of the fractured surface was obtained and was examined under scanning electron microscopy. Fracture origin was found at the cervical area of the pontic. Intraoral repair by bonding the chipped fragment back in place was performed. After 15 days, the porcelain fragment debonded without patient knowledge and the fragment was lost. Then, intraoral repair using composite resin to restore the fractured area was performed and is still in function to date. CONCLUSIONS: Based on the 5-years survival of the performed intraoral repair, the composite resin reconstruction technique has shown to be an adequate alternative treatment for fractured FPD. CLINICAL SIGNIFICANCE: A resin composite repair of the fracture site can be performed in one clinical session, using much less time and cost than for the replacement of FPD. This clinical case survived 5 years to date.


Assuntos
Porcelana Dentária , Zircônio , Materiais Dentários , Falha de Restauração Dentária , Prótese Parcial Fixa , Humanos
18.
Clin Oral Investig ; 23(12): 4345-4353, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30953165

RESUMO

OBJECTIVES: To evaluate the critical bond strength (σ) of ceramic and metal brackets to a lithium disilicate-based glass-ceramic. MATERIALS AND METHODS: Two hundred and forty ceramic specimens (IPS e-max CAD) were randomly distributed in 12 experimental groups (n = 20). Two ceramic brackets (monocrystalline, BCm; and polycrystalline, BCp) and a metal bracket (BM) were bonded to glass-ceramic specimens after one of the following surface treatments: HF-hydrofluoric acid applied for 60 s; S-silane applied for 3 min; HFS-HF followed by S; and MDP-application of an adhesive containing a phosphate monomer (MDP). All brackets were bonded to the treated glass-ceramic using a resin cement, stored in 37 °C water for 48 h before shear bond strength testing. Optical (OM) and scanning electron (SEM) microscopies were used for fractographic analysis. Data was statistically analyzed using Kruskal-Wallis and Student-Newman-Keuls (α = 0.05). RESULTS: BCm bonded to glass-ceramic treated with either HFS or HF showed the highest median σ values, respectively, 10.5 MPa and 8.5 MPa. In contrast, the BCp bonded to glass-ceramic treated with MDP showed the lowest median σ value (0.8 MPa), which was not statistically different from other MDP-treated groups. CONCLUSIONS: The failure mode was governed by the glass-ceramic surface treatment, not by the bracket type. Quantitative (σ values) and qualitative (fracture mode) data suggested a minimum of 5 MPa for brackets bonded to glass-ceramic, which is the lower critical limit bond strength for a comprehensive orthodontic treatment. CLINICAL RELEVANCE: Bonding brackets to glass-ceramic requires micromechanical retention.


Assuntos
Cerâmica/química , Colagem Dentária , Corrosão Dentária/métodos , Teste de Materiais/métodos , Braquetes Ortodônticos , Análise do Estresse Dentário , Humanos , Microscopia Eletrônica de Varredura , Cimentos de Resina/química , Resistência ao Cisalhamento , Propriedades de Superfície
19.
J Esthet Restor Dent ; 31(1): 93-97, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30379397

RESUMO

OBJECTIVE: To evaluate the effect of storage time and temperature on the effectiveness of bleaching agents. METHODS: Enamel slabs were randomly allocated according to the concentration of carbamide peroxide (CP): 10% (CP10) and 16% (CP16). Shade evaluations were conducted at baseline and then after 3 and 12 months of storage at 3 different temperatures: 10°C (±2°C), 25°C (±2°C), and 35°C (±2°C). Objective color evaluation was performed (spectrophotometer CIEL*a*b* system and CIEDE2000) to calculate the color change (ΔE00 ). Subjective evaluation was performed using the VITA classical shade guide followed by shade variation (ΔS). RESULTS: The bleaching effect of different CP concentrations (10% and 16%) at baseline showed no differences with regard to objective (ΔE00 ) and subjective parameters (ΔS) (P > .05). No differences were observed between CP concentrations stored for the same length of time and at the same temperature for either parameter (P > .05). In terms of objective measurement (ΔE00 ), a reduction in the bleaching effect was shown for both CP concentrations (10% and 16%) when stored for 12 months at 35°C, and compared with the baseline (P < .05). As regards the subjective parameters (ΔS), after 12 months, both CP concentrations (10% and 16%) stored at 35°C showed a decrease in bleaching capacity compared to baseline (P < .05). CP10 and CP16 stored at 10°C and 25°C did not suffer any loss in bleaching ability, even after 12 months (P > .05). CONCLUSIONS: The storage of bleaching agents for long periods at high temperatures can reduce the bleaching effectiveness of CP at 10% and 16%. CLINICAL SIGNIFICANCE: Clinicians must be made aware that they should store their bleaching products under proper temperature conditions and use them within an appropriate time frame; otherwise, the bleaching effect could be lost.


Assuntos
Clareadores Dentários , Clareamento Dental , Peróxido de Hidrogênio , Peróxidos , Temperatura , Ureia
20.
J Prosthet Dent ; 121(6): 929-934, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30745103

RESUMO

STATEMENT OF PROBLEM: Restorative materials are cemented on different types of substrates, such as dentin, metal, and glass-fiber posts with composite resin cores. PURPOSE: The purpose of this in vitro study was to evaluate the failure behavior after cycling fatigue of a polymer-infiltrated ceramic network material (PICN; VITA ENAMIC) cemented on different supporting substrates. MATERIAL AND METHODS: PICN plates (N=80) were obtained from computer-assisted design and computer-assisted manufacturing (CAD-CAM) blocks and cemented with a resin cement to 4 different supporting substrates (n=20): (1) human dentin (PICNDen); (2) dentin analog (PICNDenAn); (3) nickel-chromium alloy (PICNNiCr); and (4) composite resin plus fiberglass post (PICNRc). For comparison, the fracture behavior of a feldspathic ceramic (FelDenAn; VITABLOCS Mark II) and an indirect composite resin (ResDenAn; Opallis LAB Resin) cemented to the DenAn substrate was investigated (n=20). Thus, specimens were composed of the restorative material layer (1-mm thick) resin cemented (0.1-mm-thick layer) to a 2-mm-thick supporting substrate. All specimens were subjected to mechanical cycling (MC) using a pneumatic cycling machine (500 000 cycles, 2 Hz, 50 N). Specimens that did not fracture during cycling were tested under compression using a universal testing machine at a cross-head speed of 0.5 mm/min until the sound of the first crack was detected using an acoustic system. Failure data were statistically evaluated using Weibull distribution. Failures were classified as radial crack, cone crack, combined, and catastrophic fracture. RESULTS: All FelDenAn specimens were fractured during MC. Only 4 PICNRc specimens survived MC, so their fracture load data were not statistically analyzed. PICNNiCr showed the greatest characteristic load (L0) value, followed by ResDenAn. Groups PICNDenAn and PICNDen showed lower and similar L0 but statistically different Weibull modulus (m). There was a significant relationship between experimental group and failure mode (P<.001). FelDenAn and PICNRc had a higher frequency of radial cracks, whereas PICNNiCr failed from cone cracking. CONCLUSIONS: The supporting substrate influenced the failure behavior of PICN. When the substrate had a higher elastic modulus than the restorative material, better mechanical behavior was observed.


Assuntos
Falha de Restauração Dentária , Polímeros , Cerâmica , Desenho Assistido por Computador , Análise do Estresse Dentário , Humanos , Teste de Materiais , Cimentos de Resina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA