Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Gen Intern Med ; 35(2): 624, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31953680

RESUMO

This editorial, "Internal Medicine Point of Care Ultrasound: Indicators It's Here to Stay" (DOI: 10.1007/s11606-019-05268-0), was intended to accompany "Education Indicators for Internal Medicine Point-of-Care Ultrasound: a Consensus Report from the Canadian Internal Medicine Ultrasound (CIMUS) Group".

2.
Clin Teach ; 16(6): 615-622, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30761751

RESUMO

BACKGROUND: In self-regulated procedural simulation, learners practise on many simulators (e.g. paracentesis), self-regulating their choice of simulators, time and goals. Current needs assessments cannot predict the number of simulators needed to plan cost-effective self-regulated simulation. Knowing the ratios of simulators and participants would allow for better-informed purchase decisions to be made. METHODS: We designed 90-minute sessions of self-regulated procedural simulation for internal medicine residents. In Phase 1, 51 participants (8.5 per group) could use 22 simulators (US$69 925): ultrasound-guided central (n = 6) and peripheral (n = 2) venous catheterisation; thoracocentesis (n = 2); paracentesis (n = 2); lumbar puncture (n = 6); and arthrocentesis (n = 4). We calculated minimal numbers of simulators based on the time that participants used each simulator in order to design a resource-effective Phase 2, with 24 participants (with 12 per group) using 14 simulators (US$48 720) to meet their needs. RESULTS: Calculated from time of use (83 minutes in total), the optimal ratios of simulators expressed for 10 participants were 9.2: 3.7 for jugular and subclavian venous catheterisation (33 minutes); 1.5 for thoracocentesis (13 minutes), 1.0 for femoral venous catheterisation (9 minutes), 1.0 for lumbar puncture (9 minutes), 0.8 for peripheral venous catheterisation (8 minutes), 0.7 for paracentesis (6 minutes) and 0.5 for arthrocentesis (5 minutes). In Phase 2, the usage rate of simulators increased from 35.5% to 76.6%, maintaining the total time of use at 80.4 minutes. CONCLUSIONS: We present a replicable method for the cost-effective planning of self-regulated simulation by measuring the use of simulators. Expressed as ratios of simulators per participant, this information can support purchase decisions and be shared with similar programmes.


Assuntos
Medicina Interna/educação , Internato e Residência/estatística & dados numéricos , Treinamento por Simulação/estatística & dados numéricos , Competência Clínica , Análise Custo-Benefício , Avaliação Educacional , Eficiência Organizacional/economia , Eficiência Organizacional/estatística & dados numéricos , Humanos , Treinamento por Simulação/economia , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA