1.
Chemosphere ; 59(3): 397-403, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15763092

RESUMO

With the aim to evaluate the effect of temperature, 4-chloro-3-methyl phenol (CMP) degradation by Fenton's reagent was investigated at 25 and 70 degrees C under the following initial conditions: [CMP]0 = 10 mM, [Fe2+]0 = 0.5 mM; ([H2O2]0/[CMP]0) = 80, pH0 = 3. The results indicated that CMP degradation was strongly influenced by temperature. In fact, the maximum TOC removal, achieved after ca. 24h, was by far greater at 70 degrees C (85%) than at 25 degrees C (36%). The same happened for organic chlorine (TOX) conversion into inorganic chloride, i.e. 100%, after 3 h at 70 degrees C, and 87%, after 27 h at 25 degrees C. As the recorded trends of CMP removal and chloride formation were basically the same, hydroxy substitution (ipso-substitution) was hypothesised as one likely mechanism of CMP degradation. The higher level of mineralization recorded at 70 degrees C was ascribed to: (i) a greater *OH concentration; (ii) a consequently greater extent of CMP oxidation to organic acids; (iii) a higher decarboxylation rate of such acids. An interesting consequence of such extended organic acids decarboxylation was a pH increase up to 8 that, in turn, caused, in the treated mixture, the decomposition of excess H2O2 as well as the precipitation of iron ions. These two latter outcomes are technologically important considering that usually, before discharging Fenton treated wastewater, specific polishing steps are required just to remove iron ions, decompose excess hydrogen peroxide and neutralise the pH.


Assuntos
Clorofenóis/química , Peróxido de Hidrogênio/química , Ferro/química , Temperatura , Purificação da Água/métodos , Cloro/química , Cromatografia Líquida de Alta Pressão , Cromatografia por Troca Iônica , Oxigênio/química
2.
Chemosphere ; 57(7): 579-86, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15488919

RESUMO

The reductive degradation of a chlorinated herbicide by iron powder was investigated at lab scale. The studied substrate was triallate (S-2,3,3-trichloroallyl di-isopropyl thiocarbamate) which contains a trichloroethylene moiety potentially reducible by zero-valent iron. Degradation reactions were carried out in batch, at 25 degrees C, in the absence of oxygen, by contacting electrolytic iron powder (size range: 20-50 microm) with a triallate aqueous solution (2.5 mgl(-1)). Herbicide decay, corresponding evolutions of TOC, TOX and chloride ion release were regularly monitored throughout the reactions. Furthermore, the main degradation by-products were identified by HPLC/MS. The results showed that, after 5 days, herbicide degradation extent was about 97% and that the reaction proceeded through the formation of a dechlorinated alkyne by-product (S-2-propinyl di-isopropyl thiocarbamate) resulting from the complete dechlorination of triallate. The subsequent reduction of such an alkyne intermediate gave S-allyl di-isopropyl thiocarbamate as main end by-product. The identified by-products suggested that dechlorination took place mainly via reductive beta-elimination. However, as traces of dichloroallyl di-isopropyl thiocarbamate were also detected, a role, although minor, was assigned even to hydrogenolysis in the overall dechlorination process.


Assuntos
Herbicidas/química , Ferro/química , Trialato/química , Cromatografia Líquida de Alta Pressão , Cromatografia Gasosa-Espectrometria de Massas , Cinética , Modelos Químicos , Tricloroetileno/química
3.
Environ Sci Pollut Res Int ; 10(6): 379-84, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14690028

RESUMO

BACKGROUND: Chlorophenols (CPs) constitute a group of organic pollutants that are introduced into the environment as a result of several man-made activities, such as uncontrolled use of pesticides and herbicides, and as byproducts in the paper pulp bleaching. Promising removal technologies of chlorinated aromatics consist in the application of advanced oxidation processes (AOPs) that can provide an almost total degradation of a variety of contaminants. Among these, wide application find Fenton systems based on generation of reactive species having a high oxidizing power, such as hydroxyl radical HO*. Our objective was that of determining the overall degradation efficiency of the model compound 2,4-dichlorophenol (DCP) by thermal Fenton-type oxidation systems with a view toward defining in more details relevant process parameters, the effect of reaction temperature and of co-catalyst Cu2+. METHODS: Reaction conditions were similar to those generally adopted as optimal in many practical applications, i.e. pollutant/Fe2+ (as FeSO4) ratio ca. 20, Fe2+/Cu2+ (co-catalyst) 2:1, pH adjusted and controlled at pH 3, and H2O2 in excess (up to four-fold over the stoichiometric amount required for complete mineralization). RESULTS AND DISCUSSION: The results demonstrate that it is advantageous to carry out the reaction at a temperature markedly higher (70 degrees C) than ambient. The stepwise addition of H2O2 in aliquots yields an efficient transformation, while allowing a convenient control of the reaction exothermicity. Under these conditions, the essentially complete removal of the initial DCP is accomplished using just one equiv of H2O2 during 15 min; excess H2O2 (5 equivalents) yields extensive substrate mineralization. Also relevant, at 70 degrees C dechlorination of the initial DCP (and of derived reaction intermediates) is remarkably extensive (3-5% residual TOX), already with the addition of 1 equiv of H2O2. At the end of the reaction, IC and IC-MS analyses of the solution reveal that only low-molecular weight carboxylic acid (acetic, formic, oxalic, malonic, tartaric, etc.) contribute to the residual TOC. CONCLUSIONS: The whole of the results herein point to the advantage of performing the process at temperatures substantially higher than ambient (70 degrees C). Under the conditions adopted, almost complete degradation of the initial toxic compound can be achieved using hydrogen peroxide in fair excess (e.g., 3.5 equiv H2O2). RECOMMENDATIONS AND OUTLOOK: In applying practical Fenton-type degradation systems to heavily polluted wastes, either for the pre-treatment of waters with a high COD value prior to biodegradation or for complete mineralization of pollutants, the set up of appropriate reaction conditions appears to be a key factor. Also, it is desirable to keep the concentration of iron salts within the lower limits in order to minimize the production and disposal of iron oxide sludges.


Assuntos
Clorofenóis/isolamento & purificação , Poluição Ambiental/prevenção & controle , Peróxido de Hidrogênio/química , Ferro/química , Oxidantes/química , Radical Hidroxila/química , Oxirredução , Temperatura
4.
Rapid Commun Mass Spectrom ; 19(15): 2193-202, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15996017

RESUMO

The structural elucidation of by-products arising from carbofuran photodegradation using a high-pressure UV lamp has been investigated by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) employing a quadrupole time-of-flight mass spectrometer. Exact mass measurements of the [M + H]+ ions of the by-products and of product ions allowed the elemental formulae and related structures of seven photodegradation by-products (resulting, respectively, from photo-Fries rearrangement, hydroxylation of the benzene ring, oxidation of the 2,3-dihydrobenzofuran ring, cleavage of the carbamate group, hydrolysis of the ether group and the newly observed radical coupling and decarboxylation processes) to be determined confidently. Accurate mass measurements of product ions allowed ambiguities to be removed concerning neutral losses having the same nominal mass, namely CO and C2H4, allowing the fragmentation patterns to be rationalized.


Assuntos
Carbofurano/química , Monitoramento Ambiental/métodos , Inseticidas/química , Fotólise , Espectrometria de Massas por Ionização por Electrospray/métodos , Poluentes Químicos da Água , Carbofurano/análise , Carbofurano/efeitos da radiação , Cromatografia Líquida/métodos , Inseticidas/análise , Inseticidas/efeitos da radiação , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/efeitos da radiação