1.
Opt Express ; 28(8): 11597-11608, 2020 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-32403667

RESUMO

We present data from an implementation of Edge Illumination (EI) that uses a detector aperture designed for increasing dynamic range, suitable for clinically relevant X-ray energies and demonstrated here using synchrotron radiation. By utilising a sufficiently large crosstalk between pixels, this implementation enables single-scan imaging for phase and absorption, and double-scan for phase, absorption and dark field imaging. The presence of the detector mask enables a direct comparison between conventional EI and beam tracking (BT), which we conduct through Monte Carlo and analytical modelling in the case of a single-scan being used for the retrieval of all three contrasts. In the present case, where the X-ray beam width is comparable to the pixel size, we provide an analysis on best-positioning of the beam on the detector for accurate signal retrieval. Further, we demonstrate an application of this method by distinguishing different concentrations of microbubbles via their dark field signals at high energy using an EI system.

2.
Opt Express ; 25(10): 11984-11996, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28788753

RESUMO

In this paper we present a single-image phase retrieval algorithm for multi-material samples, developed for the edge illumination (EI) X-ray phase contrast imaging method. The theoretical derivation is provided, along with any assumptions made. The algorithm is evaluated quantitatively using both simulated and experimental results from a computed tomography (CT) scan using the EI laboratory implementation. Qualitative CT results are provided for a biological sample containing both bone and soft-tissue. Using a single EI image per projection and knowledge of the complex refractive index, the algorithm can accurately retrieve the interface between a given pair of materials. A composite CT slice can be created by splicing together multiple CT reconstructions, each retrieved for a different pair of materials.

3.
Opt Express ; 24(10): 11250-65, 2016 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-27409946

RESUMO

Previous studies on edge illumination (EI) X-ray phase-contrast imaging (XPCi) have investigated the nature and amplitude of the signal provided by this technique. However, the response of the imaging system to different object spatial frequencies was never explicitly considered and studied. This is required in order to predict the performance of a given EI setup for different classes of objects. To this scope, in the present work we derive analytical expressions for the contrast transfer function of an EI imaging system, using the approximation of near-field regime, and study its dependence upon the main experimental parameters. We then exploit these results to compare the frequency response of an EI system with respect of that of a free-space propagation XPCi one. The results achieved in this work can be useful for predicting the signals obtainable for different types of objects and also as a basis for new retrieval methods.

4.
J Synchrotron Radiat ; 22(4): 1072-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26134813

RESUMO

A method is proposed which enables the retrieval of the thickness or of the projected electron density of a sample from a single input image acquired with an edge illumination phase-contrast imaging setup. The method assumes the case of a quasi-homogeneous sample, i.e. a sample with a constant ratio between the real and imaginary parts of its complex refractive index. Compared with current methods based on combining two edge illumination images acquired in different configurations of the setup, this new approach presents advantages in terms of simplicity of acquisition procedure and shorter data collection time, which are very important especially for applications such as computed tomography and dynamical imaging. Furthermore, the fact that phase information is directly extracted, instead of its derivative, can enable a simpler image interpretation and be beneficial for subsequent processing such as segmentation. The method is first theoretically derived and its conditions of applicability defined. Quantitative accuracy in the case of homogeneous objects as well as enhanced image quality for the imaging of complex biological samples are demonstrated through experiments at two synchrotron radiation facilities. The large range of applicability, the robustness against noise and the need for only one input image suggest a high potential for investigations in various research subjects.

5.
Opt Express ; 23(12): 16473-80, 2015 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-26193618

RESUMO

Compatibility with polychromatic radiation is an important requirement for an imaging system using conventional rotating anode X-ray sources. With a commercially available energy-resolving single-photon-counting detector we investigated how broadband radiation affects the performance of a multi-modal edge-illumination phase-contrast imaging system. The effect of X-ray energy on phase retrieval is presented, and the achromaticity of the method is experimentally demonstrated. Comparison with simulated measurements integrating over the energy spectrum shows that there is no significant loss of image quality due to the use of polychromatic radiation. This means that, to a good approximation, the imaging system exploits radiation in the same way at all energies typically used in hard-X-ray imaging.

6.
Proc Natl Acad Sci U S A ; 109(45): 18290-4, 2012 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-23091003

RESUMO

Mammography is the primary imaging tool for screening and diagnosis of human breast cancers, but ~10-20% of palpable tumors are not detectable on mammograms and only about 40% of biopsied lesions are malignant. Here we report a high-resolution, low-dose phase contrast X-ray tomographic method for 3D diagnosis of human breast cancers. By combining phase contrast X-ray imaging with an image reconstruction method known as equally sloped tomography, we imaged a human breast in three dimensions and identified a malignant cancer with a pixel size of 92 µm and a radiation dose less than that of dual-view mammography. According to a blind evaluation by five independent radiologists, our method can reduce the radiation dose and acquisition time by ~74% relative to conventional phase contrast X-ray tomography, while maintaining high image resolution and image contrast. These results demonstrate that high-resolution 3D diagnostic imaging of human breast cancers can, in principle, be performed at clinical compatible doses.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imageamento Tridimensional/métodos , Tomografia por Raios X/métodos , Algoritmos , Relação Dose-Resposta à Radiação , Feminino , Humanos , Intensificação de Imagem Radiográfica
7.
Opt Express ; 22(23): 28199-214, 2014 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-25402060

RESUMO

Edge illumination (EI) has emerged as an X-ray phase-contrast imaging (XPCi) modality which could present significant advantages in terms of translation to clinical and laboratory applications. In this paper, we model its signal through the use of the "transport of intensity" equation. The validity conditions for this approach and its relationship with previous theoretical models for EI XPCi are discussed. The proposed model enables a simple estimation of the different contributions to the signal, which is shown to complement previously obtained results. In particular, it allows taking into account the effect of both slowly and rapidly varying refraction angles, corresponding to large and small object features. The derived framework is then used to investigate the effect on the signal of the smoothness of the mask edges, of the blurring from the source size and of the width of the object edge.


Assuntos
Algoritmos , Meios de Contraste , Luz , Iluminação , Modelos Teóricos , Humanos , Raios X
8.
Opt Express ; 22(13): 15514-29, 2014 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-24977810

RESUMO

We analyze the spatial resolution of edge illumination X-ray phase-contrast imaging and its dependence upon various experimental parameters such as source size, source-to-sample and sample-to-detector distances, X-ray energy and size of the beam-shaping aperture. Different propagation regimes, as well as the beam divergence and polychromaticity encountered with laboratory sources, are also considered. We show that spatial resolution in edge illumination phase-contrast imaging presents peculiar features compared to other X-ray phase-contrast techniques. In particular, in the direction orthogonal to the s or mask lines used to shape the beam, this can be better than both the pixel dimension and the projected source size. Numerical simulations based on Fresnel diffraction integrals are presented, which confirm the analytical predictions. The obtained results allow a simple estimation of the spatial resolution for edge-illumination phase imaging in both synchrotron and laboratory setups.

9.
Opt Express ; 22(14): 17281-91, 2014 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-25090542

RESUMO

Ptychographic techniques are currently the subject of increasing scientific interest due to their capability to retrieve the complex transmission function of an object at very high resolution. However, they impose a substantial burden in terms of acquisition time and dimension of the scanned area, which limits the range of samples that can be studied. We have developed a new method that combines the ptychographic approach in one direction with Fresnel propagation in the other by employing a strongly asymmetric probe. This enables scanning the sample in one direction only, substantially reducing exposure times while covering a large field of view. This approach sacrifices ptychographic-related resolution in one direction, but removes any limitation on the probe dimension in the direction orthogonal to the scanning, enabling the scan of relatively large objects without compromising exposure times.

10.
Opt Lett ; 39(11): 3332-5, 2014 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-24876046

RESUMO

We report on the design and realization of an x-ray imaging system for quantitative phase-contrast microscopy at high x-ray energy with laboratory-scale instrumentation. Phase and amplitude were separated quantitatively at x-ray energies up to 80 keV with micrometric spatial resolution. The accuracy of the results was tested against numerical simulations, and the spatial resolution was experimentally quantified by measuring a Siemens star phase object. This simple setup should find broad application in those areas of x-ray imaging where high energy and spatial resolution are simultaneously required and in those difficult cases where the sample contains materials with similar x-ray absorption.


Assuntos
Microscopia de Contraste de Fase/instrumentação , Desenho de Equipamento , Microscopia de Contraste de Fase/métodos , Fenômenos Ópticos , Raios X
11.
J Digit Imaging ; 27(1): 98-107, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24043594

RESUMO

Phase-contrast computed tomography (PCI-CT) has shown tremendous potential as an imaging modality for visualizing human cartilage with high spatial resolution. Previous studies have demonstrated the ability of PCI-CT to visualize (1) structural details of the human patellar cartilage matrix and (2) changes to chondrocyte organization induced by osteoarthritis. This study investigates the use of high-dimensional geometric features in characterizing such chondrocyte patterns in the presence or absence of osteoarthritic damage. Geometrical features derived from the scaling index method (SIM) and statistical features derived from gray-level co-occurrence matrices were extracted from 842 regions of interest (ROI) annotated on PCI-CT images of ex vivo human patellar cartilage specimens. These features were subsequently used in a machine learning task with support vector regression to classify ROIs as healthy or osteoarthritic; classification performance was evaluated using the area under the receiver-operating characteristic curve (AUC). SIM-derived geometrical features exhibited the best classification performance (AUC, 0.95 ± 0.06) and were most robust to changes in ROI size. These results suggest that such geometrical features can provide a detailed characterization of the chondrocyte organization in the cartilage matrix in an automated and non-subjective manner, while also enabling classification of cartilage as healthy or osteoarthritic with high accuracy. Such features could potentially serve as imaging markers for evaluating osteoarthritis progression and its response to different therapeutic intervention strategies.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Diagnóstico por Computador/métodos , Osteoartrite do Joelho/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Patela/diagnóstico por imagem , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sensibilidade e Especificidade
12.
Appl Opt ; 52(28): 6940-7, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-24085208

RESUMO

We derive a Fourier formulation of coded-aperture x-ray phase-contrast imaging, based on the wave theory of optics in the Fresnel approximation. We use this model to develop a flexible, efficient, and general simulation algorithm that can be easily adapted to other implementations of x-ray phase contrast imaging. Likewise, the algorithm enables a simple extension to 2D aperture designs, different acquisition schemes, etc. Problems related to numerical implementation of the algorithm are analyzed in detail, and simple rules are derived that enable us to avoid or at least mitigate them. Finally, comparisons with experimental data and data obtained with a different simulation algorithm are presented to validate the model and demonstrate its advantages in practical implementations. This also enabled us to demonstrate an increase in computational speed of more than one order of magnitude over a previous algorithm.


Assuntos
Algoritmos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Difração de Raios X/métodos , Difração de Raios X/instrumentação
13.
Opt Lett ; 37(5): 915-7, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22378437

RESUMO

X-ray phase contrast imaging is increasingly being used in several fields, both at synchrotron facilities and with laboratory sources, due to its increased sensitivity compared to conventional x-ray methods. One important problem is the development of methods to make it suitable for use at very high x-ray energies, needed in many applications. We show how the edge illumination concept, which stands at the basis of the coded-aperture method, allows achieving hyperintense phase signals at energies close to 100 keV, by showing images of both weak phase objects and highly absorbing fossils with a high iron content.


Assuntos
Imagem Molecular/métodos , Animais , Cefalópodes/metabolismo , Ferro/metabolismo , Fenômenos Ópticos , Raios X
14.
Opt Lett ; 36(15): 2785-7, 2011 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21808312

RESUMO

A nontomography approach for the measurement of angular-dependent coherent-scatter cross section of x rays (E≃40-80 keV) is described. It is shown that an analyzer crystal, which is proposed to be used for the sampling of the cross section, simultaneously provides information about the location of the scattering volume inside the object. A numerical simulation demonstrates that this method can be applied for nondestructive analysis of an object's internal structure.

15.
Opt Express ; 18(4): 3494-509, 2010 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-20389359

RESUMO

Many mathematical methods have been so far proposed in order to separate absorption, refraction and ultra-small angle scattering information in phase-contrast analyzer-based images. These algorithms all combine a given number of images acquired at different positions of the crystal analyzer along its rocking curve. In this paper a comprehensive quantitative comparison between five of the most widely used phase extraction algorithms based on the geometrical optics approximation is presented: the diffraction-enhanced imaging (DEI), the extended diffraction-enhanced imaging (E-DEI), the generalized diffraction-enhanced (G-DEI), the multiple-image radiography (MIR) and the Gaussian curve fitting (GCF). The algorithms are theoretically analyzed in terms of their validity conditions and experimentally compared by using geometrical phantoms providing various amounts of absorption, refraction and scattering. The presented work shows that, due to their specific validity conditions, the considered algorithms produce results that may greatly differ, especially in the case of highly refracting and/or highly scattering materials. The various extraction algorithms are also applied to images of a human bone-cartilage sample. The aim is to validate the results obtained on geometrical phantoms and prove the efficiency of the different algorithms for applications on biological samples.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Refratometria/métodos , Luz , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
16.
Med Phys ; 44(5): 1876-1885, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28236318

RESUMO

PURPOSE: This article is aimed at comparing edge illumination (EI) x-ray phase contrast computed tomography (PCT) and conventional (attenuation-based) computed tomography (CT), based on their respective contrast and noise transfer. METHODS: The noise in raw projections obtained with EI PCT is propagated through every step of the data processing, including phase retrieval and tomographic reconstruction, leading to a description of the noise in the reconstructed phase tomograms. This is compared to the noise in corresponding attenuation tomograms obtained with CT. Specifically, a formula is derived that allows evaluating the relative performance of both modalities on the basis of their contrast-to-noise ratio (CNR), for a variety of experimental parameters. RESULTS: The noise power spectra of phase tomograms are shifted towards lower spatial frequencies, leading to a fundamentally different noise texture. The relative performance of EI PCT and CT, in terms of their CNR, is linked to spatial resolution: the CNR in phase tomograms is generally superior to that in attenuation tomograms for higher spatial resolutions (tens to hundreds of µm), but inferior for lower spatial resolutions (hundreds of µm to mm). CONCLUSION: These results imply that EI PCT could outperform CT in applications for which high spatial resolutions are key, e.g., small animal or specimen imaging.


Assuntos
Iluminação , Tomografia Computadorizada por Raios X , Animais , Luz , Imagens de Fantasmas , Raios X
17.
J Med Imaging (Bellingham) ; 4(4): 040901, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29057286

RESUMO

Edge illumination (EI) is an x-ray phase-contrast imaging technique, exploiting sensitivity to x-ray refraction to visualize features, which are often not detected by conventional absorption-based radiography. The method does not require a high degree of spatial coherence and is achromatic and, therefore, can be implemented with both synchrotron radiation and commercial x-ray tubes. Using different retrieval algorithms, information about an object's attenuation, refraction, and scattering properties can be obtained. In recent years, a theoretical framework has been developed that enables EI computed tomography (CT) and, hence, three-dimensional imaging. This review provides a summary of these advances, covering the development of different image acquisition schemes, retrieval approaches, and applications. These developments constitute an integral part in the transformation of EI CT into a widely spread imaging tool for use in a range of fields.

18.
Sci Rep ; 7(1): 2187, 2017 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-28526835

RESUMO

X-ray phase contrast imaging (XPCI) is an innovative imaging technique which extends the contrast capabilities of 'conventional' absorption based x-ray systems. However, so far all XPCI implementations have suffered from one or more of the following limitations: low x-ray energies, small field of view (FOV) and long acquisition times. Those limitations relegated XPCI to a 'research-only' technique with an uncertain future in terms of large scale, high impact applications. We recently succeeded in designing, realizing and testing an XPCI system, which achieves significant steps toward simultaneously overcoming these limitations. Our system combines, for the first time, large FOV, high energy and fast scanning. Importantly, it is capable of providing high image quality at low x-ray doses, compatible with or even below those currently used in medical imaging. This extends the use of XPCI to areas which were unpractical or even inaccessible to previous XPCI solutions. We expect this will enable a long overdue translation into application fields such as security screening, industrial inspections and large FOV medical radiography - all with the inherent advantages of the XPCI multimodality.

19.
Br J Radiol ; 89(1058): 20150565, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26612467

RESUMO

OBJECTIVE: To demonstrate the feasibility of using X-ray phase-contrast tomography to assess internal organs in a post-mortem piglet model, as a possible non-invasive imaging autopsy technique. METHODS: Tomographic images of a new-born piglet were obtained using a free-space propagation X-ray phase-contrast imaging setup at a synchrotron (European Synchrotron Radiation Facility, Grenoble, France). A monochromatic X-ray beam (52 keV) was used in combination with a detector pixel size of 46 × 46 µm(2). A phase-retrieval algorithm was applied to all projections, which were then reconstructed into tomograms using the filtered-back projection algorithm. Images were assessed for diagnostic quality. RESULTS: Images obtained with the free-space propagation setup presented high soft-tissue contrast and sufficient resolution for resolving organ structure. All of the main body organs (heart, lungs, kidneys, liver and intestines) were easily identified and adequately visualized. In addition, grey/white matter differentiation in the cerebellum while still contained within the skull was shown. CONCLUSION: The feasibility of using X-ray phase-contrast tomography as a post-mortem imaging technique in an animal model has been demonstrated. Future studies will focus on translating this experiment to a laboratory-based setup. ADVANCES IN KNOWLEDGE: Appropriate image processing and analysis enable the simultaneous visualization of both soft- and hard-tissue structures in X-ray phase-contrast images of a complex, thick sample.


Assuntos
Autopsia/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Animais Recém-Nascidos , Estudos de Viabilidade , Interpretação de Imagem Radiográfica Assistida por Computador , Suínos , Tomografia Computadorizada por Raios X/instrumentação
20.
Phys Med ; 32(12): 1759-1764, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27836637

RESUMO

PURPOSE: Edge illumination (EI) X-ray phase-contrast imaging (XPCI) has been under development at University College London in recent years, and has shown great potential for both laboratory and synchrotron applications. In this work, we propose a new acquisition and processing scheme. Contrary to existing retrieval methods for EI, which require as input two images acquired in different setup configurations, the proposed approach can retrieve an approximate map of the X-ray phase from a single image, thus significantly simplifying the acquisition procedure and reducing data collection times. METHODS: The retrieval method is analytically derived, based on the assumption of a quasi-homogeneous object, i.e. an object featuring a constant ratio between refractive index and absorption coefficient. The noise properties of the input and retrieved images are also theoretically analyzed under the developed formalism. The method is applied to experimental synchrotron images of a biological object. RESULTS: The experimental results show that the method can provide high-quality images, where the "edge" signal typical of XPCI images is transformed to an "area" contrast that enables an easier interpretation of the sample geometry. Moreover, the retrieved images confirm that the method is highly stable against noise. CONCLUSIONS: We anticipate that the developed approach will become the method of choice for a variety of applications of EI XPCI, thanks to its ability to simplify the acquisition procedure and reduce acquisitions time and dose to the sample. Future work will focus on the adaptation of the method to computed tomography and to polychromatic radiation from X-ray tubes.


Assuntos
Iluminação , Radiografia/instrumentação , Razão Sinal-Ruído , Processamento de Imagem Assistida por Computador , Síncrotrons , Madeira , Raios X
SELEÇÃO DE REFERÊNCIAS