Pediatr Cardiol ; 45(3): 520-528, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38233665

RESUMO

Anomalous aortic origin of right coronary artery (AAORCA) is associated with myocardial ischemia and sudden cardiac arrest/death. Risk stratification remains challenging and relies upon provocative test results. This study describes the utility of dobutamine stress cardiovascular magnetic resonance (DSCMR) and potential benefit of strain analysis in children with AAORCA. All patients less than 21 years of age with AAORCA who underwent DSCMR between July 2018 and December 2022 were included. Visual wall motion abnormalities (VWMA) at rest and during protocolized increments of dobutamine infusion were assessed. Regional and global left ventricular circumferential (GCS) and radial (GRS) strain using 2-dimension Feature tracking (2D-FT) analysis (cvi42, Circle Cardiovascular Imaging Inc.) were calculated at rest and peak response. Of the total 54 DSCMR studies performed in 51 children with median age (IQR) of 13.5 (11-15) years, FT analysis was reliably performed in 52 (96%) studies. None had VWMA. The absolute change in GCS and GRS from rest to peak dobutamine stress was 4% (1-6%) and 11% (4-18%), respectively. There was no significant difference in GCS and GRS in patients with exertional symptoms vs no/non-exertional symptoms as well as between those considered to be high-risk vs low-risk anatomical features. DSCMR-derived 2D-FT strain analysis is feasible to assess myocardial deformation in children with AAORCA and may enhance this method of provocative testing. Although there were no statically significant differences in GCS and GRS values between high and low-risk subgroups, the absolute change in GCS between rest and peak stress is diminished when compared to normal adult reports.


Assuntos
Vasos Coronários , Dobutamina , Adulto , Humanos , Criança , Adolescente , Vasos Coronários/diagnóstico por imagem , Contração Miocárdica/fisiologia , Coração , Morte Súbita Cardíaca , Espectroscopia de Ressonância Magnética
2.
Pediatr Radiol ; 53(11): 2188-2196, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37563320

RESUMO

BACKGROUND: Intravenous adenosine induces pharmacological stress by causing vasodilatation and thus carries the risk of severe hypotension when combined with vasodilatory effects of anesthetic agents. OBJECTIVE: This study describes our experience with a reduced dose adenosine cardiac magnetic resonance imaging (MRI) protocol in young children under general anesthesia (GA). MATERIALS AND METHODS: This is a retrospective report of all patients from birth to 18 years who underwent adenosine stress cardiac MRI under GA between August 2018 and November 2022. Based on our anecdotal experience of severe adverse effects in patients receiving adenosine infusion under GA and in discussion with the pediatric anesthesia team, we developed a modified protocol starting at a dose of 110 mcg/kg/min with incremental escalation to a full dose of 140 mcg/kg/min to achieve desired hemodynamic effect. RESULTS: Twenty-two children (mean age 6.5 years, mean weight 28 kg) satisfied the inclusion criteria. The diagnoses included Kawasaki disease (7), anomalous aortic origin of left coronary artery (3), anomalous aortic origin of right coronary artery (2), coronary fistula (3), repaired d-transposition of great arteries (2), repaired anomalous left coronary artery from pulmonary artery (2), repaired truncus arteriosus with left coronary artery occlusion (1), extracardiac-Fontan with left coronary artery myocardial bridge (1), and post heart transplantation (1). Nine patients needed dose escalation beyond 110 mcg/kg/min. Two patients had transient hypotension during testing (systemic blood pressure drop > 25 mmHg). No patient developed significant heart block or bronchospasm. Six patients (repeat study in one) demonstrated inducible perfusion defects (27%) on stress perfusion sequences-5 of whom had confirmed significant coronary abnormalities on angiography or direct surgical inspection. CONCLUSION: A reduced/incremental dose adenosine stress cardiac MRI protocol under GA in children is safe and feasible. This avoids severe hypotension which is both unsafe and may result in inaccurate data.

3.
J Cardiovasc Magn Reson ; 24(1): 32, 2022 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-35650624

RESUMO

INTRODUCTION: Cardiovascular magnetic resonance (CMR)-guided cardiac catheterization is becoming more widespread due to the ability to acquire both functional CMR measurements and diagnostic catheterization data without exposing patients to ionizing radiation. However, the real-time imaging sequences used for catheter guidance during these procedures are limited in resolution and the anatomical detail they can provide. In this study, we propose a passive catheter tracking approach which simultaneously improves catheter tracking and visualization of the anatomy. METHODS: 60 patients with congenital heart disease underwent CMR-guided cardiac catheterization on a 1.5T CMR scanner (Ingenia, Philips Healthcare, Best the Netherlands) using the Philips iSuite system. The proposed T1-overlay technique uses a commercially available heavily T1-weighted sequence to image the catheter, and overlays it on a high-resolution 3D dataset within iSuite in real-time. Suppressed tissue in the real-time images enables the use of a thick imaging slab to assist in tracking of the catheter. Improvement in catheter visualization time was compared between T1-overlay and the conventional invasive CMR (iCMR) balanced steady state free precession (bSSFP) sequence. This technique also enabled selective angiography visualization for real-time evaluation of blood flow dynamics (such as pulmonary transit time), similar to direct contrast injection under standard fluoroscopy. Estimates of pulmonary transit time using iCMR were validated using x-ray fluoroscopy in 16 patients. RESULTS: The T1-overlay approach significantly increased the time that the catheter tip was kept in view by the technologist compared to the bSSFP sequence conventionally used for iCMR. The resulting images received higher ratings for blood/balloon contrast, anatomy visualization, and overall suitability for iCMR guidance by three cardiologists. iCMR selective angiography using T1-overlay also provided accurate estimates of pulmonary transit time that agreed well with x-ray fluoroscopy. CONCLUSION: We demonstrate a new passive catheter tracking technique using the iSuite platform that improves visualization of the catheter and cardiac anatomy. These improvements significantly increase the time that the catheter tip is seen throughout the procedure. We also demonstrate the feasibility of iCMR selective angiography for the measurement of pulmonary transit time.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Cateterismo Cardíaco/métodos , Catéteres , Humanos , Imagem por Ressonância Magnética Intervencionista/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
4.
Pediatr Cardiol ; 2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36534136

RESUMO

BACKGROUND: Diagnosis of infective endocarditis (IE) can be challenging due to negative blood cultures and diagnostic limitations of various imaging modalities. Transesophageal echocardiography (TEE) is the gold standard imaging modality for visualization of valvular vegetations. However, due to the anterior location of the pulmonary valve, post-surgical changes, and sedation requirement, TEE can be challenging in the pediatric population. The aim of this study was to assess the value of Cardiac CT (CCT) for diagnosis of IE in children and young adults with congenital heart disease (CHD). METHODS: This is a single-center retrospective study of pediatric patients with CHD and diagnosis of IE who underwent CCT from 2018 to 2022. Data collected included age, gender, cardiac diagnosis, clinical presentation, echocardiographic/CCT findings, and blood culture results. In addition, modified Duke criteria (MDC) for the diagnosis of IE were applied with and without CCT findings as the diagnostic imaging criterion. RESULTS: Fourteen patients were included in this study with a median age of 11 years old. Nine patients were female. Ten patients had IE of the RV-PA conduit and four patients had IE of the aortic valve. Using MDC, 4 patients had definite IE. After including CCT findings, 11 patients (79%) met MDC for definite IE. Blood cultures were positive in 12 patients. CCT revealed the following complications: thromboembolic findings/pseudoaneurysms in 5 patients each and prosthetic valve perforation/prosthetic valve leak in one patient each. CONCLUSIONS: This study reinforces the complimentary role of CCT to echocardiography in the work-up and diagnosis of IE in patients with CHD. With further improvement in lowering radiation exposure, CCT may have a key role in the diagnostic work-up of endocarditis and could be implemented in the diagnostic criteria of IE.

5.
J Cardiovasc Magn Reson ; 23(1): 16, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33641664

RESUMO

BACKGROUND: Due to passive blood flow in palliated single ventricle, central venous pressure increases chronically, ultimately impeding lymphatic drainage. Early visualization and treatment of these malformations is essential to reduce morbidity and mortality. Cardiovascular magnetic resonance (CMR) T2-weighted lymphangiography (T2w) is used for lymphatic assessment, but its low signal-to-noise ratio may result in incomplete visualization of thoracic duct pathway. 3D-balanced steady state free precession (3D-bSSFP) is commonly used to assess congenital cardiac disease anatomy. Here, we aimed to improve diagnostic imaging of thoracic duct pathway using 3D-bSSFP. METHODS: Patients underwent CMR during single ventricle or central lymphatic system assessment using T2w and 3D-bSSFP. T2w parameters included 3D-turbo spin echo (TSE), TE/TR = 600/2500 ms, resolution = 1 × 1 × 1.8 mm, respiratory triggering with bellows. 3D-bSSFP parameters included electrocardiogram triggering and diaphragm navigator, 1.6 mm isotropic resolution, TE/TR = 1.8/3.6 ms. Thoracic duct was identified independently in T2w and 3D-bSSFP images, tracked completely from cisterna chyli to its drainage site, and classified based on severity of lymphatic abnormalities. RESULTS: Forty-eight patients underwent CMR, 46 of whom were included in the study. Forty-five had congenital heart disease with single ventricle physiology. Median age at CMR was 4.3 year (range 0.9-35.1 year, IQR 2.4 year), and median weight was 14.4 kg (range, 7.9-112.9 kg, IQR 5.2 kg). Single ventricle with right dominant ventricle was noted in 31 patients. Thirty-eight patients (84%) were status post bidirectional Glenn and 7 (16%) were status post Fontan anastomosis. Thoracic duct visualization was achieved in 45 patients by T2w and 3D-bSSFP. Complete tracking to drainage site was attained in 11 patients (24%) by T2w vs 25 (54%) by 3D-bSSFP and in 28 (61%) by both. Classification of lymphatics was performed in 31 patients. CONCLUSION: Thoracic duct pathway can be visualized by 3D-bSSFP combined with T2w lymphangiography. Cardiac triggering and respiratory navigation likely help retain lymphatic signal in the retrocardiac area by 3D-bSSFP. Visualizing lymphatic system leaks is challenging on 3D-bSSFP images alone, but 3D-bSSFP offers good visualization of duct anatomy and landmark structures to help plan interventions. Together, these sequences can define abnormal lymphatic pathway following single ventricle palliative surgery, thus guiding lymphatic interventional procedures.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imageamento Tridimensional , Linfografia , Imageamento por Ressonância Magnética , Ducto Torácico/diagnóstico por imagem , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Lactente , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ducto Torácico/fisiopatologia , Adulto Jovem
6.
Pediatr Cardiol ; 42(6): 1275-1283, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33900430

RESUMO

Patients after surgical repair of Tetralogy of Fallot (rTOF) may suffer a decrease in left ventricular (LV) function. The aim of our study is to evaluate a novel method of assessing LV torsion in patients with rTOF, as an early indicator of systolic LV dysfunction. Motion tracking based on image registration regularized by the equilibrium gap principle, known as equilibrated warping, was employed to assess LV torsion. Seventy-six cases of rTOF and ten normal controls were included. The group of controls was assessed for reproducibility using both equilibrated warping and standard clinical tissue tracking software (CVI42, version 5.10.1, Calgary, Canada). Patients were dichotomized into two groups: normal vs. loss of torsion. Torsion by equilibrated warping was successfully obtained in 68 of 76 (89%) patients and 9 of 10 (90%) controls. For equilibrated warping, the intra- and interobserver coefficients of variation were 0.095 and 0.117, respectively, compared to 0.260 and 0.831 for tissue tracking by standard clinical software. The intra- and inter-observer intraclass correlation coefficients for equilibrated warping were 0.862 and 0.831, respectively, compared to 0.992 and 0.648 for tissue tracking. Loss of torsion was noted in 32 of the 68 (47%) patients with rTOF. There was no difference in LV or RV volumes or ejection fraction between these groups. The assessment of LV torsion by equilibrated warping is feasible and shows good reliability. Loss of torsion is common in patients with rTOF and its robust assessment might contribute into uncovering heart failure in an earlier stage.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Pré-Escolar , Humanos , Lactente , Complicações Pós-Operatórias/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
7.
Pediatr Cardiol ; 42(3): 578-589, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33394116

RESUMO

Ventricular contouring of cardiac magnetic resonance imaging is the gold standard for volumetric analysis for repaired tetralogy of Fallot (rTOF), but can be time-consuming and subject to variability. A convolutional neural network (CNN) ventricular contouring algorithm was developed to generate contours for mostly structural normal hearts. We aimed to improve this algorithm for use in rTOF and propose a more comprehensive method of evaluating algorithm performance. We evaluated the performance of a ventricular contouring CNN, that was trained on mostly structurally normal hearts, on rTOF patients. We then created an updated CNN by adding rTOF training cases and evaluated the new algorithm's performance generating contours for both the left and right ventricles (LV and RV) on new testing data. Algorithm performance was evaluated with spatial metrics (Dice Similarity Coefficient (DSC), Hausdorff distance, and average Hausdorff distance) and volumetric comparisons (e.g., differences in RV volumes). The original Mostly Structurally Normal (MSN) algorithm was better at contouring the LV than the RV in patients with rTOF. After retraining the algorithm, the new MSN + rTOF algorithm showed improvements for LV epicardial and RV endocardial contours on testing data to which it was naïve (N = 30; e.g., DSC 0.883 vs. 0.905 for LV epicardium at end diastole, p < 0.0001) and improvements in RV end-diastolic volumetrics (median %error 8.1 vs 11.4, p = 0.0022). Even with a small number of cases, CNN-based contouring for rTOF can be improved. This work should be extended to other forms of congenital heart disease with more extreme structural abnormalities. Aspects of this work have already been implemented in clinical practice, representing rapid clinical translation. The combined use of both spatial and volumetric comparisons yielded insights into algorithm errors.


Assuntos
Algoritmos , Ventrículos do Coração/diagnóstico por imagem , Redes Neurais de Computação , Tetralogia de Fallot/diagnóstico por imagem , Adulto , Estudos de Casos e Controles , Feminino , Ventrículos do Coração/anatomia & histologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino
8.
Cardiol Young ; 30(5): 656-662, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32290877

RESUMO

Novel commercially available software has enabled registration of both CT and MRI images to rapidly fuse with X-ray fluoroscopic imaging. We describe our initial experience performing cardiac catheterisations with the guidance of 3D imaging overlay using the VesselNavigator system (Philips Healthcare, Best, NL). A total of 33 patients with CHD were included in our study. Demographic, advanced imaging, and catheterisation data were collected between 1 December, 2016 and 31 January, 2019. We report successful use of this technology in both diagnostic and interventional cases such as placing stents and percutaneous valves, performing angioplasties, occlusion of collaterals, and guidance for lymphatic interventions. In addition, radiation exposure was markedly decreased when comparing our 10-15-year-old coarctation of the aorta stent angioplasty cohort to cases without the use of overlay technology and the most recently published national radiation dose benchmarks. No complications were encountered due to the application of overlay technology. 3D CT or MRI overlay for CHD intervention with rapid registration is feasible and aids decisions regarding access and planned angiographic angles. Operators found intraprocedural overlay fusion registration using placed vessel guidewires to be more accurate than attempts using bony structures.


Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Lactente , Recém-Nascido , Masculino , Imagem Multimodal , Estudos Retrospectivos , Software , Adulto Jovem
10.
JRSM Cardiovasc Dis ; 11: 20480040221087556, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35342625

RESUMO

A high temporal resolution, 4-chamber (4CH) cine is the standard method for determining cardiac rest periods during whole heart coronary magnetic resonance angiography (CMRA). We evaluated the image quality and reproducibility between the 4CH cine method and a novel approach using a velocity encoded mitral valve inflow cine (MVI). The goal of this study was to compare the quality of CMRAs utilizing MVI versus 4CH methods. Sharpness and vessel length for the LCA and RCA using each method were determined using Soap Bubble and two blinded observers independently assessed coronary image quality. Offline analysis on a separate, retrospective cohort (n = 25) was used to compare MVI and 4CH reproducibility. In the prospectively evaluated cohort there was no difference in overall vessel sharpness (4CH vs MVI mean ± SD) (31.0 ± 5.5% vs 30.5 ± 5.7%, p = .63), LCA vessel sharpness (30.0 ± 5.4% vs 31.1 ± 8.2%, p = .44), LCA length (4.7 ± 1.4 cm vs 4.6 ± 1.6 cm, p = .66), RCA vessel sharpness (32.1 ± 6.9% vs 31.1 ± 7.7%, p = .55), RCA length (5.51 ± 2.6 cm vs 5.95 ± 2.4 cm, p = .38), or image quality rating (2.66 vs 2.62, p = .80) between methods. In the retrospective cohort, the MVI method had 5.4% lower inter-observer variability (95% CI 3.7,7.2%, p < .0001) and 3.9% lower intra-observer variability (95% CI 2.4,5.4%, p < .0001) than the 4CH method. MVI is a technically feasible and more reproducible method to determine cardiac rest periods compared to 4CH while preserving vessel sharpness, vessel length & image quality.

11.
Diagnostics (Basel) ; 10(10)2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-33003498

RESUMO

BACKGROUND: Non-invasive determination of liver iron concentration (LIC) is a valuable tool that guides iron chelation therapy in transfusion-dependent patients. Multiple methods have been utilized to measure LIC by MRI. The purpose of this study was to compare free breathing R2* (1/T2*) to whole-liver Ferriscan R2 method for estimation of LIC in a pediatric and young adult population who predominantly have hemoglobinopathies. METHODS: Clinical liver and cardiac MRI scans from April 2016 to May 2018 on a Phillips 1.5 T scanner were reviewed. Free breathing T2 and T2* weighted images were acquired on each patient. For T2, multi-slice spin echo sequences were obtained. For T2*, a single mid-liver slice fast gradient echo was performed starting at 0.6 ms with 1.2 ms increments with signal averaging. R2 measurements were performed by Ferriscan analysis. R2* measurements were performed by quantitative T2* map analysis. RESULTS: 107 patients underwent liver scans with the following diagnoses: 76 sickle cell anemia, 20 Thalassemia, 9 malignancies and 2 Blackfan Diamond anemia. Mean age was 12.5 ± 4.5 years. Average scan time for R2 sequences was 10 min, while R2* sequence time was 20 s. R2* estimation of LIC correlated closely with R2 with a correlation coefficient of 0.94. Agreement was strongest for LIC < 15 mg Fe/g dry weight. Overall bias from Bland-Altman plot was 0.66 with a standard deviation of 2.8 and 95% limits of agreement -4.8 to 6.1. CONCLUSION: LIC estimation by R2* correlates well with R2-Ferriscan in the pediatric age group. Due to the very short scan time of R2*, it allows imaging without sedation or anesthesia. Cardiac involvement was uncommon in this cohort.

12.
Cardiovasc Diagn Ther ; 8(3): 214-224, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30057871

RESUMO

Congenital pulmonary vascular anomalies are typically found in infancy or early childhood however, some may remain silent and present in adult patients. Anomalies may be separated into anatomic categories based on involvement of the pulmonary arteries, pulmonary veins or both with or without involvement of the lung parenchyma. Association with congenital heart disease and other syndromes is very common. Computed tomography (CT) and magnetic resonance imaging (MRI) are both invaluable at assessment of these anomalies allowing for both diagnosis and detailed treatment planning. This article will focus primarily on the use of CT, as the high resolution evaluation of the lung parenchyma is also important in many of these conditions. In young patients especially, rapid heart rate and concerns of radiation exposure are important considerations when performing CT. This article will discuss scan techniques as well as clinical diagnostic considerations and basic endovascular treatment of congenital pulmonary vascular anomalies.

13.
Int J Cardiovasc Imaging ; 32(8): 1273-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27173489

RESUMO

Three-dimensional printing has an increasing number of clinical applications in pediatric cardiology. Time required for dataset segmentation and conversion to stereolithography (STL) format remains a significant limitation. We investigated the impact of semi-automated cardiovascular-specific segmentation software on time and reproducibility of segmentation. Magnetic resonance angiograms (MRAs) of 19 patients undergoing intervention for right ventricular outflow lesions were segmented to demonstrate the right heart. STLs were created by two independent clinicians using semi-automated cardiovascular segmentation (SAS) and traditional manual segmentation (MS). Time was recorded and geometric STL disagreement was determined (0 % = no disagreement, 100 % = complete disagreement). MRA datasets were categorized as clean when only right heart structures were present in the MRA, or contaminated when left heart structures were also present and required removal. Eighteen (seven clean and 11 contaminated) cases were successfully segmented with both methods. Time to STL for clean datasets was faster with MS than SAS [median 209 s (IQR 192-252) vs. 296 s (272-317), p = 0.018] while contaminated datasets were faster with SAS [455 s (384-561) vs. 866 s (310-1429), p = 0.033]. Interobserver STL geometric disagreement was significantly lower using SAS than MS overall (0.70 ± 1.15 % vs. 1.31 ± 1.52 %, p = 0.030), and for the contaminated subset (0.81 ± 1.08 % vs. 1.75 ± 1.57 %, p = 0.036). Most geometric disagreement occurred at areas where left heart contamination was removed. Semi-automated segmentation was faster and more reproducible for contaminated datasets, while MS was faster but equally reproducible for clean datasets. Semi-automated segmentation methods are preferable for contaminated datasets and continued refinement of these tools should be supported.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Impressão Tridimensional , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Adolescente , Automação , Cateterismo Cardíaco , Criança , Pré-Escolar , Meios de Contraste/administração & dosagem , Feminino , Cardiopatias Congênitas/complicações , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA