RESUMO
PURPOSE: To investigate the current practices in anatomy teaching at French universities in 2023. METHODS: On January 10, 2023, a questionnaire was sent to all members of the official list of the French Medical College of Professors of Anatomy. Each Anatomy centre was asked to complete this online form only once. The questionnaire covered several key themes, including broad questions, dissections practices, "virtual" dissections, teaching methods and teaching staff. RESULTS: The questionnaire was completed by 26/28 anatomy centres. Access to body donor dissection is reported to be mandatory in 15 of the 26 centers (58%), optional in 10 centers (38%), and "tolerated" in one center (4%). Fifteen of 26 centers (58%) reported having a virtual dissection table for teaching anatomy. Concerning the teaching of anatomy via live ultrasound, 10 out of 26 centers (38%) reported providing it. Regarding the teaching methods used for medical students, chalk and board lectures are the most common method, although the intensity of use varies. Most lectures are given with chalk and board in 42% (11/26) of the centers. In about 73% (19/26) of the centers, tablet lectures are used. Regarding anatomy teachers, it was reported that in 24/26 anatomy centres (92%), more than 50% of the courses for medical students are taught by professors holding the chair of anatomy (21/26 professors (81%), 3/26 associate professors (12%)). CONCLUSION: The present study endeavors to contribute to the existing body of knowledge on anatomy education by offering insights into the current practices in French universities.
Assuntos
Anatomia , Educação de Graduação em Medicina , Estudantes de Medicina , Humanos , Educação de Graduação em Medicina/métodos , Dissecação/educação , Currículo , França , Inquéritos e Questionários , Carbonato de Cálcio , Anatomia/educação , EnsinoRESUMO
PURPOSE: The objective of this work was to assess, in a quantitative and qualitative way, the teaching of cervical and abdominal anatomy via ultrasound for medical students. METHODS: For several years, tutorials on the study of anatomy through use of ultrasound on the living organism have been given at the Medical School of Brest. These sessions have focused on cervical anatomy and abdominal anatomy. Students were invited to quantitatively assess these lessons by taking two tests containing questions on both cervical and abdominal anatomy and ultrasound technique: a pre-test administered at the beginning of the year and a post-test at the end of the year. In addition, a qualitative assessment was carried out at the end of the year. Ten statements were presented, and students were asked to indicate their agreement or disagreement to a four-point Likert scale. RESULTS: One hundred and twelve students answered all the questions on the pre-test with an average of 13.4 correct answers out of 20. Forty-eight students answered all the questions on the post-test with an average of 14.6/20. Twenty-six students who benefited from the courses gave positive feedback about the workshops on the qualitative assessment at the end of the year (median scores > = 3/4). CONCLUSION: The results of this work suggest that the use of ultrasound makes a positive contribution to the teaching of anatomy. The students interviewed think this type of tutorial should be an integral part of the anatomy curriculum at our university. In addition, this type of instruction can serve to introduce the use of ultrasound itself in a practical learning setting.
Assuntos
Anatomia , Educação de Graduação em Medicina , Estudantes de Medicina , Humanos , Avaliação Educacional/métodos , Educação de Graduação em Medicina/métodos , Ultrassonografia , Currículo , Anatomia/educaçãoRESUMO
OBJECTIVE: To assess the diagnostic accuracy of iodine map computed tomography pulmonary angiography (CTPA), for segment-based evaluation of lung perfusion in patients with acute pulmonary embolism (PE), using perfusion single-photon emission CT (SPECT) imaging as a reference standard. METHODS: Thirty participants who have been diagnosed with acute pulmonary embolism on CTPA underwent perfusion SPECT/CT within 24 h. Perfusion SPECT and iodine map were independently interpreted by 2 nuclear medicine physicians and 2 radiologists. For both modalities, each segment was classified as normoperfused or hypoperfused, as defined by a perfusion defect of more than 25% of a segment. The primary end point was the diagnostic accuracy (sensitivity and specificity) of iodine map for segment-based evaluation of lung perfusion, using perfusion SPECT imaging as a reference standard. Following blinded interpretation, a retrospective explanatory analysis was performed to determine potential causes of misinterpretation. RESULTS: The median time between CTPA with iodine maps and perfusion SPECT was 14 h (range 2-23 h). A total of 597 segments were analyzed. Sensitivity and specificity of iodine maps with CTPA for the detection of segmental perfusion defects were 231/284 = 81.3% (95% CI 76.4 to 85.4%) and 247/313 = 78.9% (95% CI 74.1 to 83.1%), respectively. In retrospect, false results were explained in 48.7%. CONCLUSION: Iodine map CTPA showed promising results for the assessment of pulmonary perfusion in patients with acute PE, with sensitivity of 81.3% and specificity of 78.9%, respectively. Recognition of typical pitfalls such as atelectasis, fissures, or beam-hardening artifacts may further improve the accuracy of the test. KEY POINTS: ⢠Sensitivity and specificity of iodine subtraction maps for the detection of segmental perfusion defects were 81.3% (95% CI 76.4 to 85.4%) and 78.9% (95% CI 74.1 to 83.1%), respectively. ⢠Recognition of typical pitfalls such as atelectasis, fissures, or beam-hardening artifacts may further improve the diagnostic accuracy of the test.
Assuntos
Angiografia Digital/métodos , Angiografia por Tomografia Computadorizada/métodos , Isótopos de Iodo/farmacologia , Pulmão/diagnóstico por imagem , Embolia Pulmonar/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Iodo , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Estudos RetrospectivosRESUMO
This technical note describes a novel CT scan protocol that includes a non-enhanced CT, dynamic CTA, and perfusion of the whole brain and CTA of the carotid arteries using a 320-row area detector CT scanner, with a unique contrast injection and acceptable radiation exposure dose in patients presenting with acute ischemic stroke. The acquisition parameters and reconstruction parameters will be discussed including the use of model-based iterative reconstruction (MBIR), time summing (tMIP), and subtraction techniques to optimize the results of this protocol.Key Points⢠Scanning on a 320-row area detector CT can achieve both brain perfusion with dynamic angiography and reconstructed arterial and venous CTA, and supra aortic trunk angiography, in a single acquisition. ⢠It provides, in a single exam, a full diagnostic workup, i.e., all the acquisitions that are needed to make a quick decision, with reasonable exposure to ionizing radiation and reduced amount of medium contrast, in case of acute ischemic stroke presentation.
Assuntos
Isquemia Encefálica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Artérias Carótidas/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Humanos , Imagem de Perfusão , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Técnica de SubtraçãoRESUMO
OBJECTIVE: The aim was to determine if dual-energy computed tomography (DECT) can discriminate ferromagnetic bullets from nonferromagnetic ones. METHODS: The ferromagnetic properties of 29 bullets were determined. All bullets underwent a DECT evaluation, and a manual measurement of the dual-energy index was performed by 2 radiologists, followed by a fully automatic measurement, in 3 different positions in a phantom (air, water, and bone). RESULTS: Twenty-one bullets were found to be nonferromagnetic. There were significant differences between the mean of the dual-energy index measured in the core of ferromagnetic projectiles and those of nonferromagnetic ones in the lung position of the phantom (P = 0.007). Specificity was 86.36%, and negative predictive value was 90.48%. Among the 29 bullets, 24 were correctly classified. CONCLUSIONS: Our study demonstrates that DECT can assess the ferromagnetic status of bullets and their magnetic resonance imaging compatibility using an extended computed tomography scale in an ex vivo phantom model.
Assuntos
Corpos Estranhos/diagnóstico por imagem , Campos Magnéticos , Metais , Tomografia Computadorizada por Raios X/métodos , Ferimentos por Arma de Fogo/diagnóstico por imagem , Balística Forense , Humanos , Imagens de FantasmasAssuntos
Barreira Hematoencefálica , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Humanos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Barreira Hematoencefálica/diagnóstico por imagem , Neuroimagem/métodos , Imagem Multimodal/métodos , Concussão Encefálica/diagnóstico por imagem , Acoplamento Neurovascular/fisiologiaRESUMO
ABSTRACT: After receiving erlotinib for 4 years, a man with advanced lung adenocarcinoma was treated with stereotactic radiotherapy for a left cerebellar brain metastasis. Local relapse of the metastasis was suspected 14 months after and confirmed on 18 F-DOPA PET. Three additional uptakes were described with no unequivocal MRI pathological signal. A second radiotherapy course was delivered. One year later, isolated local recurrence was suspected on a 3 T MRI, with a suspicious 18 F-DOPA uptake. Five additional 18 F-DOPA uptakes were described among which one increased between the 2 PETs. Because of these MRI/PET mismatches, a switch from erlotinib to osimertinib was preferred over surgery.
Assuntos
Adenocarcinoma de Pulmão , Neoplasias Pulmonares , Masculino , Humanos , Cloridrato de Erlotinib/uso terapêutico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adenocarcinoma de Pulmão/diagnóstico por imagem , Cerebelo , Imageamento por Ressonância Magnética , Sobreviventes , Neoplasias Pulmonares/diagnóstico por imagem , Receptores ErbBRESUMO
PURPOSE: The accuracy of target delineation in radiation treatment planning of high-grade gliomas (HGGs) is crucial to achieve high tumor control, while minimizing treatment-related toxicity. Magnetic resonance imaging (MRI) represents the standard imaging modality for delineation of gliomas with inherent limitations in accurately determining the microscopic extent of tumors. The purpose of this study was to assess the survival impact of multi-observer delineation variability of multiparametric MRI (mpMRI) and [18F]-FET PET/CT. MATERIALS AND METHODS: Thirty prospectively included patients with histologically confirmed HGGs underwent a PET/CT and mpMRI including diffusion-weighted imaging (DWI: b0, b1000, ADC), contrast-enhanced T1-weighted imaging (T1-Gado), T2-weighted fluid-attenuated inversion recovery (T2Flair), and perfusion-weighted imaging with computation of relative cerebral blood volume (rCBV) and K2 maps. Nine radiation oncologists delineated the PET/CT and MRI sequences. Spatial similarity (Dice similarity coefficient: DSC) was calculated between the readers for each sequence. Impact of the DSC on progression-free survival (PFS) and overall survival (OS) was assessed using Kaplan-Meier curves and the log-rank test. RESULTS: The highest DSC mean values were reached for morphological sequences, ranging from 0.71 +/- 0.18 to 0.84 +/- 0.09 for T2Flair and T1Gado, respectively, while metabolic volumes defined by PET/CT achieved a mean DSC of 0.75 +/- 0.11. rCBV variability (mean DSC0.32 +/- 0.20) significantly impacted PFS (p = 0.02) and OS (p = 0.002). CONCLUSIONS: Our data suggest that the T1-Gado and T2Flair sequences were the most reproducible sequences, followed by PET/CT. Reproducibility for functional sequences was low, but rCBV inter-reader similarity significantly impacted PFS and OS.
RESUMO
BACKGROUND: To compare a model-based iterative reconstruction (MBIR) versus a hybrid iterative reconstruction (HIR) for initial and final Alberta Stroke Program Early Ct Score (ASPECT) scoring in acute ischemic stroke (AIS). We hypothesized that MBIR designed for brain computed tomography (CT) could perform better than HIR for ASPECT scoring. METHODS: Among patients who had undergone CT perfusion for AIS between April 2018 and October 2019 with a follow-up imaging within 7 days, we designed a cohort of representative ASPECTS. Two readers assessed regional-cerebral-blood-volume-ASPECT (rCBV-ASPECTS) on the initial exam and final-ASPECTS on the follow-up non-contrast-CT (NCCT) in consensus. Four readers performed independently MBIR and HIR ASPECT scoring on baseline NCCT. RESULTS: In total, 294 hemispheres from 147 participants (average age of 69.59 ± 15.63 SD) were analyzed. Overall raters' agreement between rCBV-map and MBIR and HIR ranged from moderate to moderate (κ = 0.54 to κ = 0.57) with HIR and moderate to substantial (κ = 0.52 to κ = 0.74) with MBIR. Overall raters' agreement between follow-up imaging and HIR/MBIR ranged from moderate to moderate (κ = 0.55 to κ = 0.59) with HIR and moderate to almost perfect (κ = 0.48 to κ = 0.82) with MBIR. CONCLUSIONS: ASPECT scoring with MBIR more closely matched with initial and final infarct extent than classical HIR NCCT reconstruction.
Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Humanos , AVC Isquêmico/diagnóstico por imagem , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodosRESUMO
In this report, we describe the functional imaging findings of systemic artery to pulmonary artery shunt in V/Q SPECT CT imaging. A 63-year-old man with small-cell lung cancer underwent CT pulmonary angiography (CTPA) for suspected acute pulmonary embolism (PE). The CTPA showed an isolated segmental filling defect in the right lower lobe, which was initially interpreted as positive for PE but was actually the consequence of a systemic artery to pulmonary artery shunt due to the recruitment of the bronchial arterial network by the adjacent tumor. A V/Q SPECT/CT scan was also performed, demonstrating a matched perfusion/ventilation defect in the right lower lobe.
Assuntos
Artéria Pulmonar , Embolia Pulmonar , Angiografia/métodos , Angiografia por Tomografia Computadorizada/métodos , Humanos , Pulmão , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagemRESUMO
The standard therapy strategy for high-grade glioma (HGG) is based on the maximal surgery followed by radio-chemotherapy (RT-CT) with insufficient control of the disease. Recurrences are mainly localized in the radiation field, suggesting an interest in radiotherapy dose escalation to better control the disease locally. We aimed to identify a similarity between the areas of high uptake on O-(2-[18F]-fluoroethyl)-L-tyrosine (FET) positron emission tomography/computed tomography (PET) before RT-CT, the residual tumor on post-therapy NADIR magnetic resonance imaging (MRI) and the area of recurrence on MRI. This is an ancillary study from the IMAGG prospective trial assessing the interest of FET PET imaging in RT target volume definition of HGG. We included patients with diagnoses of HGG obtained by biopsy or tumor resection. These patients underwent FET PET and brain MRIs, both after diagnosis and before RT-CT. The follow-up consisted of sequential brain MRIs performed every 3 months until recurrence. Tumor delineation on the initial MRI 1 (GTV 1), post-RT-CT NADIR MRI 2 (GTV 2), and progression MRI 3 (GTV 3) were performed semi-automatically and manually adjusted by a neuroradiologist specialist in neuro-oncology. GTV 2 and GTV 3 were then co-registered on FET PET data. Tumor volumes on FET PET (MTV) were delineated using a tumor to background ratio (TBR) ≥ 1.6 and different % SUVmax PET thresholds. Spatial similarity between different volumes was performed using the dice (DICE), Jaccard (JSC), and overlap fraction (OV) indices and compared together in the biopsy or partial surgery group (G1) and the total or subtotal surgery group (G2). Another overlap index (OV') was calculated to determine the threshold with the highest probability of being included in the residual volume after RT-CT on MRI 2 and in MRI 3 (called "hotspot"). A total of 23 patients were included, of whom 22% (n = 5) did not have a NADIR MRI 2 due to a disease progression diagnosed on the first post-RT-CT MRI evaluation. Among the 18 patients who underwent a NADIR MRI 2, the average residual tumor was approximately 71.6% of the GTV 1. A total of 22% of patients (5/23) showed an increase in GTV 2 without diagnosis of true progression by the multidisciplinary team (MDT). Spatial similarity between MTV and GTV 2 and between MTV and GTV 3 were higher using a TBR ≥ 1.6 threshold. These indices were significantly better in the G1 group than the G2 group. In the FET hotspot analysis, the best similarity (good agreement) with GTV 2 was found in the G1 group using a 90% SUVmax delineation method and showed a trend of statistical difference with those (poor agreement) in the G2 group (OV' = 0.67 vs. 0.38, respectively, p = 0.068); whereas the best similarity (good agreement) with GTV 3 was found in the G1 group using a 80% SUVmax delineation method and was significantly higher than those (poor agreement) in the G2 group (OV'= 0.72 vs. 0.35, respectively, p = 0.014). These results showed modest spatial similarity indices between MTV, GTV 2, and GTV 3 of HGG. Nevertheless, the results were significantly improved in patients who underwent only biopsy or partial surgery. TBR ≥ 1.6 and 80-90% SUVmax FET delineation methods showing a good agreement in the hotspot concept for targeting standard dose and radiation boost. These findings need to be tested in a larger randomized prospective study.
RESUMO
Background: The aim of this prospective monocentric study was to assess the inter-observer agreement for tumor volume delineations by multiparametric MRI and 18-F-FET-PET/CT in newly diagnosed, untreated high-grade glioma (HGG) patients. Methods: Thirty patients HGG underwent O-(2-[18F]-fluoroethyl)-l-tyrosine(18F-FET) positron emission tomography (PET), and multiparametric MRI with computation of rCBV map and K2 map. Three nuclear physicians and three radiologists with different levels of experience delineated the 18-F-FET-PET/CT and 6 MRI sequences, respectively. Spatial similarity (Dice and Jaccard: DSC and JSC) and overlap (Overlap: OV) coefficients were calculated between the readers for each sequence. Results: DSC, JSC, and OV were high for 18F-FET PET/CT, T1-GD, and T2-FLAIR (>0.67). The Spearman correlation coefficient between readers was ≥0.6 for these sequences. Cross-comparison of similarity and overlap parameters showed significant differences for DSC and JSC between 18F-FET PET/CT and T2-FLAIR and for JSC between 18F-FET PET/CT and T1-GD with higher values for 18F-FET PET/CT. No significant difference was found between T1-GD and T2-FLAIR. rCBV, K2, b1000, and ADC showed correlation coefficients between readers <0.6. Conclusion: The interobserver agreements for tumor volume delineations were high for 18-F-FET-PET/CT, T1-GD, and T2-FLAIR. The DWI (b1000, ADC), rCBV, and K2-based sequences, as performed, did not seem sufficiently reproducible to be used in daily practice.
Assuntos
Neoplasias Encefálicas , Glioma , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/radioterapia , Glioma/diagnóstico por imagem , Glioma/patologia , Glioma/radioterapia , Humanos , Variações Dependentes do Observador , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos , Tomografia Computadorizada por Raios X , TirosinaRESUMO
ABSTRACT: Glioma stem cells (GSCs) are the source of tumor recurrence in glioblastoma and are capable of whole tumor regeneration once the treatment has concluded. Compelling evidence from the last decade suggests that GSC may arise from neural stem cells residing in the adult subventricular zone (SVZ). We report the findings of an 18F-FET PET/CT showing pathological uptake in SVZ with a tumor-background ratio of greater than 1.6, giving evidence for glioblastoma recurrence. This case highlights the particular attention to be paid to the SVZ given the possible development of GSC.
Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Glioblastoma/diagnóstico por imagem , Ventrículos Laterais/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tirosina/análogos & derivados , Adulto , Neoplasias Encefálicas/patologia , Feminino , Glioblastoma/patologia , Humanos , Ventrículos Laterais/patologia , RecidivaRESUMO
The aim was to assess the occurrence of magnetic susceptibility artifacts (MSA) following endovascular treatment of intracranial aneurysm by stent using susceptibility weighted imaging (SWI). Imaging and clinical data of 46 patients who underwent stent placement in the case of intracranial aneurysm endovascular treatment (S-Group) were retrospectively analyzed and compared to a control group (C-Group) in which 46 patients had coiling alone. The mean number of MSA was higher in the S-group than in the C-group on postprocedural SWI sequence (8.76, 95%CI [5.76; 11.76] vs. 0.78 [0.32; 1.25], respectively, p < 0.001) with a higher frequency of the appearance of MSA also in the S-group (78.26% vs. 21.74% in the C-group, p < 0.001). In the S-group, in the vascular territory of the treated artery, there was a higher number of MSA than in other vascular territories (mean of 5.18 [3.43; 6.92] vs. 3.08 [1.79; 4.36], p = 0.001). An odds ratio (OR) of 20.98 [5.24; 83.95] suggested a higher proportion of onset of MSA in the S-group than in the C-group (p < 0.001). The appearance of MSA after a treatment by stenting for intracranial aneurysm in patients under antiplatelet therapy was common, particularly in the treated artery territory.
Assuntos
Aneurisma Roto , Procedimentos Endovasculares , Aneurisma Roto/etiologia , Aneurisma Roto/terapia , Artefatos , Procedimentos Endovasculares/efeitos adversos , Humanos , Fenômenos Magnéticos , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Retrospectivos , Stents/efeitos adversosRESUMO
âBACKGROUND AND PURPOSE: Intracranial aneurysms are a frequently occurring disease, with an estimated prevalence of 2-5% in the general population. They usually remain silent until rupture occurs, with a mortality rate of 35-50% and a high rate of morbidity, including long-term disability. However, preventative treatments have their own risk of complications and morbi-mortality rates, including stroke and hemorrhage. ECG-gated four-dimensional CT angiography (4D-CTA) allows the acquisition of time-resolved three-dimensional reconstructions. The aim of our study was to evaluate different intracranial aneurysm metrics over the cardiac cycle using ECG-gated 4D-CTA. âMATERIALS AND METHODS: ECG-gated 4D-CTA datasets were acquired in patients presenting with intracranial aneurysms. Seven aneurysm metrics, including aneurysm height, aneurysm length, ostium width, aspect ratio, ostium area, volume, and volume-to-ostium ratio, were analysed over different cardiac phases. Intra-reader agreement, inter-reader agreement, and inter-cycle agreement were calculated through the intraclass correlation coefficient. âRESULTS: Twenty-one aneurysms from 11 patients were considered for inclusion. Post-processing failed for three aneurysms, and 18 aneurysms were finally analysed. There was good intra-reader agreement for each metric (ICC >0.9). Agreements among three consecutive cardiac cycles were calculated for six aneurysms and were especially good for the volume metric (ICC >0.9). Volume variation appears to be the most relevant metric and seems especially perceptible for aneurysms larger than 5 mm. âCONCLUSIONS: Quantification of aneurysm volume changes during the cardiac cycle seems quantitatively possible and reproducible, especially for aneurysms larger than 5 mm. Further studies need to be conducted to validate this parameter for intracranial aneurysm assessment.
Assuntos
Angiografia Cerebral/métodos , Eletrocardiografia/métodos , Tomografia Computadorizada Quadridimensional/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Angiografia Cerebral/normas , Eletrocardiografia/normas , Feminino , Tomografia Computadorizada Quadridimensional/normas , Humanos , Masculino , Pessoa de Meia-Idade , Estudos RetrospectivosRESUMO
PURPOSE: Delayed cerebral ischemia represents a significant cause of poor functional outcome for patients with vasospasm after subarachnoid hemorrhage. We investigated whether delayed cerebral ischemia could be detected by the arterial opacification of internal carotid artery at the level of the skull base. METHODS: In this exploratory, nested retrospective cohort diagnostic accuracy study, patients with clinical and/or transcranial Doppler suspicion of vasospasm who underwent four-dimensional computed tomography angiography were included. They were split into two groups for the main endpoint analysis, according to the actually adopted morphological (cerebral infarction) and clinical criteria (neurologic deterioration) of delayed cerebral ischemia. Opacification with a temporal resolution of 0.15 s of both internal carotid arteries at the skull base level was obtained through a semi-automated segmentation method based on skeletonization, and analyzed by a wavelet transform (rbio2.2, level 1). The results obtained by k-means clustering were analyzed with regard to the state of delayed cerebral infarction. RESULTS: Over ten patients included and analyzed, five patients presented a delayed cerebral ischemia, two of them in both side. The semi-automated processing and analysis clustered two different types of opacification curves. The obtaining of a nonlinear opacification pattern was associated (p < 0.001) with delayed cerebral ischemia. CONCLUSIONS: The analysis of arterial opacification of internal carotid arteries at skull base by the proposed processing is feasible and leads to cluster two types of opacification that may help to early detect and prevent delayed cerebral ischemia, in particularly when examinations are artifacted by aneurysm treatment materials.
Assuntos
Isquemia Encefálica/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Angiografia Cerebral/métodos , Tomografia Computadorizada Quadridimensional/métodos , Hemorragia Subaracnóidea/complicações , Adolescente , Adulto , Idoso , Isquemia Encefálica/etiologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Base do Crânio/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Vasoespasmo Intracraniano/complicações , Vasoespasmo Intracraniano/diagnóstico por imagem , Adulto JovemRESUMO
Objectives: 68Ga Ventilation/Perfusion V/Q PET-CT is a promising imaging tool for pulmonary embolism diagnosis. However, no study has verified whether the interpretation is reproducible between different observers. The aim of this study was to assess the interobserver agreement in the interpretation of V/Q PET-CT for the diagnosis of acute PE, and to compare it to the interobserver agreement of CTPA interpretation. Methods: Twenty-four cancer patients with suspected acute PE underwent V/Q PET-CT and CTPA within 24 h as part of a prospective pilot study evaluating V/Q PET-CT for the management of patients with suspected PE. V/Q PET-CT and CTPA scans were reassessed independently by four nuclear medicine physicians and four radiologists, respectively. Physicians had different levels of expertise in reading V/Q scintigraphy and CTPA. Interpretation was blinded to the initial interpretation and any clinical information or imaging test result. For each modality, results were reported on a binary fashion. V/Q PET/CT scans were read as positive if there was at least one segmental or two subsegmental mismatched perfusion defects. CTPA scans were interpreted as positive if there was a constant intraluminal filling defect. Interobserver agreement was assessed by calculating kappa (κ) coefficients. Results: Out of the 24 V/Q PET-CT scans, the diagnostic conclusion was concordantly negative in 22 patients and concordantly positive in one patient. The remaining scan was interpreted as positive by one reader and negative by three readers. Out of the 24 CTPA scans, the diagnostic conclusion was concordantly negative in 16 and concordantly positive in one. Out of the seven remaining scans, PE was reported by one reader in four cases, by two readers in two cases, by three readers in one case. Most of discordant results on CTPA were related to clots reported on subsegmental arteries. Mean kappa coefficient was 0.79 for V/Q PET-CT interpretation and 0.39 for CTPA interpretation. Conclusions: Interobserver agreement in the interpretation of V/Q PET-CT for PE diagnosis was substantial (kappa 0.79) in a population with a low prevalence of significant PE. Agreement was lower with CTPA, mainly as a result of discrepancies at the level of the subsegmental arteries.
RESUMO
PURPOSE: The aim of this study was to prospectively investigate tumor volume delineation by amino acid PET and multiparametric perfusion magnetic resonance imaging (MRI) in patients with newly diagnosed, untreated high grade glioma (HGG). MATERIALS AND METHODS: Thirty patients with histologically confirmed HGG underwent O-(2-[18F]-fluoroethyl)-l-tyrosine (18F-FET) positron emission tomography (PET), conventional Magnetic Resonance Imaging (MRI) as contrast-enhanced (CE) and fluid-attenuated inversion recovery (FLAIR) and multiparametric MRI as relative cerebral blood volume (rCBV) and permeability estimation map (K2). Areas of MRI volumes were semi-automatically segmented. The percentage overlap volumes, Dice and Jaccard spatial similarity coefficients (OV, DSC, JSC) were calculated. RESULTS: The 18F-FET tumor volume was significantly larger than the CE volume (median 43.5 mL (2.5-124.9) vs. 23.8 mL (1.4-80.3), p = 0.005). The OV between 18F-FET uptake and CE volume was low (median OV 0.59 (0.10-1)), as well as spatial similarity (median DSC 0.52 (0.07-0.78); median JSC 0.35 (0.03-0.64)). Twenty-five patients demonstrated both rCBV and CE on MRI: The median rCBV tumor volume was significantly smaller than the median CE volume (p < 0.001). The OV was high (median 0.83 (0.54-1)), but the spatial similarity was low (median DSC 0.45 (0.04-0.83); median JSC 0.29 (0.07-0.71)). Twenty-eight patients demonstrated both K2 and CE on MRI. The median K2 tumor volume was not significantly larger than the median CE volume. The OV was high (median OV 0.90 (0.61-1)), and the spatial similarity was moderate (median DSC 0.75 (0.01-0.83); median JSC 0.60 (0.11-0.89)). CONCLUSION: We demonstrated that multiparametric perfusion MRI volumes (rCBV, K2) were highly correlated with CE T1 gadolinium volumes whereas 18F-FET PET provided complementary information, suggesting that the metabolically active tumor volume in patients with newly diagnosed untreated HGG is critically underestimated by contrast enhanced MRI. 18F-FET PET imaging may help to improve target volume delineation accuracy for radiotherapy planning.