Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 60: 388-396, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31200063

RESUMO

BACKGROUND: The clinical benefits and outcomes of the interventional treatment of small-sized infrapopliteal arteries using stent implantation remain uncertain. The aim of this study was to compare the safety and efficacy of drug-free bioresorbable vascular scaffold (BVS) with that of bare metal stent (BMS) in endovascular treatment of small-sized peripheral arteries. METHODS: In this study, drug-free BVS and BMS were used in eight porcine models. We compared the angiographic and histomorphometric findings in the two groups at 4 weeks. In each pig, BVS and BMS of adequate sizes were implanted in the small branch (<3 mm) of the femoral artery. Angiography, intravascular ultrasound (IVUS), and histomorphometric analysis were performed at 4 weeks. RESULTS: In the 4-week follow-up angiography and IVUS examination, the minimal luminal diameter was smaller and diameter stenosis was more severe in the BVS group. Histomorphometric findings indicated that the lumen area in the BVS group was smaller (0.34 ± 0.28 mm2 vs. 1.40 ± 0.52 mm2, P < 0.001), whereas the neointimal area (2.70 ± 1.28 mm2 vs. 1.76 ± 0.66 mm2, P = 0.013), area stenosis (85.18 ± 13.14 % vs. 54.99 ± 16.13 %, P < 0.001), inflammatory score (2.07 ± 0.861 vs. 28 ± 0.39, P = 0.003), and fibrin scores (1.24 ± 0.70 vs. 0.79 ± 0.72, P = 0.043) were significantly higher in the BVS group. The injury score was higher in the BMS group. In histopathologic findings, restenosis was mainly due to recoil and distortion of the scaffold in the BVS group. CONCLUSIONS: Compared with BMS, drug-free BVS was not feasible for small-sized peripheral arteries based on the angiographic, IVUS, and histomorphometric results primarily due to insufficient mechanical support.


Assuntos
Implantes Absorvíveis , Angioplastia com Balão/instrumentação , Stents Farmacológicos , Artéria Femoral , Metais , Stents , Angiografia , Angioplastia com Balão/efeitos adversos , Animais , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/patologia , Artéria Femoral/fisiopatologia , Masculino , Desenho de Prótese , Sus scrofa , Fatores de Tempo , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA