Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38944192

RESUMO

Thoracic aortic aneurysms evolving within a type IIIb chronic aortic dissection are mostly treated with the deployment of an endograft. However, several cases of dissecting aneurysms are associated with a significant dilatation of the aortic arch. These cases are usually managed in two steps : arch reconstruction or supra-aortic trunk debranching at first and a secondary graft deployment for the descending thoracic aorta. We present through this case series an alternative approach for this severe condition which consists in the replacement of the thoracic aorta from its hemi-arch to the distal thoracic or visceral aorta using a left thoracotomy. We deliberately neglected the remaining dissecting aorta if its diameter was below 45 mm, hypothesizing its non evolution after repair. From 2012 to 2021, 9 patients have been treated for a thoracic aneurysm evolving after a IIIb chronic aortic dissection using a left thoracotomy and a 19°C circulatory arrest. Immediate postoperative results show no mortality nor neurological disorders and the 7 years follow up for all of these 9 cases enlightened the absence of aneurysmal evolution especially for the distal anastomosis and the remaining dissected aorta. This work suggests that this direct approach strategy can definitively treat a thoracic dissecting aneurysm unsuitable for a simple endovascular treatment.

2.
Eur Heart J ; 43(7): 654-662, 2022 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-34586392

RESUMO

AIMS: Isolated tricuspid valve surgery (ITVS) is considered to be a high-risk procedure, but in-hospital mortality is markedly variable. This study sought to develop a dedicated risk score model to predict the outcome of patients after ITVS for severe tricuspid regurgitation (TR). METHODS AND RESULTS: All consecutive adult patients who underwent ITVS for severe non-congenital TR at 12 French centres between 2007 and 2017 were included. We identified 466 patients (60 ± 16 years, 49% female, functional TR in 49%). In-hospital mortality rate was 10%. We derived and internally validated a scoring system to predict in-hospital mortality using multivariable logistic regression and bootstrapping with 1000 re-samples. The final risk score ranged from 0 to 12 points and included eight parameters: age ≥70 years, New York Heart Association Class III-IV, right-sided heart failure signs, daily dose of furosemide ≥125 mg, glomerular filtration rate <30 mL/min, elevated bilirubin, left ventricular ejection fraction <60%, and moderate/severe right ventricular dysfunction. Tricuspid regurgitation mechanism was not an independent predictor of outcome. Observed and predicted in-hospital mortality rates increased from 0% to 60% and from 1% to 65%, respectively, as the score increased from 0 up to ≥9 points. Apparent and bias-corrected areas under the receiver operating characteristic curves were 0.81 and 0.75, respectively, much higher than the logistic EuroSCORE (0.67) or EuroSCORE II (0.63). CONCLUSION: We propose TRI-SCORE as a dedicated risk score model based on eight easy to ascertain parameters to inform patients and physicians regarding the risk of ITVS and guide the clinical decision-making process of patients with severe TR, especially as transcatheter therapies are emerging (www.tri-score.com).


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Adulto , Idoso , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Mortalidade Hospitalar , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Função Ventricular Esquerda
3.
Rev Med Suisse ; 19(817): 477-485, 2023 Mar 08.
Artigo em Francês | MEDLINE | ID: mdl-36883709

RESUMO

The negative impact of tricuspid regurgitation on prognosis in now well established. It also appears clear that surgical and possibly percutaneous treatment should be performed before reaching a point of no return with advanced heart failure and deterioration of right ventricle function. Percutaneous treatment has been divided into coaptation restoration devices, annuloplasty devices, and ortho- or heterotopic valve replacement. The present article offers a brief review of diagnostic modalities beyond echocardiography, surgical treatment as well as of the multiple recent development in the percutaneous treatment of this frequent condition.


L'impact pronostique défavorable de l'insuffisance tricuspide (IT) est maintenant bien établi, ainsi que la nécessité d'intervenir chirurgicalement ou de manière percutanée lorsque le traitement médicamenteux est insuffisant. Des données récentes suggèrent par ailleurs qu'il est probablement judicieux d'intervenir avant qu'un stade trop avancé d'insuffisance cardiaque et d'atteinte du ventricule droit ne soit atteint. Le traitement percutané est divisé en dispositifs de restauration de la coaptation valvulaire, d'annuloplastie et de remplacement de valve ortho ou hétérotopique. Cet article propose une brève revue des modalités diagnostiques au-delà de l'échocardiographie, du traitement chirurgical ainsi que des multiples développements récents dans le traitement percutané de cette pathologie fréquente.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Ecocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Transtornos da Memória , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/cirurgia
4.
Int J Mol Sci ; 23(16)2022 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-36012201

RESUMO

The routine use of mechanical circulatory support during lung transplantation (LTx) is still controversial. The use of prophylactic human albumin (HA) or hypertonic sodium lactate (HSL) prime in mechanical circulatory support during LTx could prevent ischemia−reperfusion (IR) injuries and pulmonary endothelial dysfunction and thus prevent the development of pulmonary graft dysfunction. The objective was to investigate the impact of cardiopulmonary bypass (CPB) priming with HA and HSL compared to a CPB prime with Gelofusine (GF) on pulmonary endothelial dysfunction in a lung IR rat model. Rats were assigned to four groups: IR-CPB-GF group, IR-CPB-HA group, IR-CPB-HSL group and a sham group. The study of pulmonary vascular reactivity by wire myograph was the primary outcome. Glycocalyx degradation (syndecan-1 and heparan) was also assessed by ELISA and electron microscopy, systemic and pulmonary inflammation by ELISA (IL-1ß, IL-10, and TNF-α) and immunohistochemistry. Clinical parameters were evaluated. We employed a CPB model with three different primings, permitting femoral−femoral assistance with left pulmonary hilum ischemia for IR. Pulmonary endothelium-dependent relaxation to acetylcholine was significantly decreased in the IR-CPB-GF group (11.9 ± 6.2%) compared to the IR-CPB-HA group (52.8 ± 5.2%, p < 0.0001), the IR-CPB-HSL group (57.7 ± 6.3%, p < 0.0001) and the sham group (80.8 ± 6.5%, p < 0.0001). We did not observe any difference between the groups concerning glycocalyx degradation, and systemic or tissular inflammation. The IR-CPB-HSL group needed more vascular filling and developed significantly more pulmonary edema than the IR-CPB-GF group and the IR-CPB-HA group. Using HA as a prime in CPB during Ltx could decrease pulmonary endothelial dysfunction's IR-mediated effects. No effects of HA were found on inflammation.


Assuntos
Ponte Cardiopulmonar , Traumatismo por Reperfusão , Animais , Ponte Cardiopulmonar/efeitos adversos , Modelos Animais de Doenças , Humanos , Inflamação , Isquemia , Ratos , Reperfusão , Albumina Sérica Humana
5.
Eur Heart J ; 41(45): 4304-4317, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32974668

RESUMO

AIMS: The aim of this study was to identify determinants of in-hospital and mid-term outcomes after isolated tricuspid valve surgery (ITVS) and more specifically the impact of tricuspid regurgitation (TR) mechanism and clinical presentation. METHODS AND RESULTS: Among 5661 consecutive adult patients who underwent a tricuspid valve (TV) surgery at 12 French tertiary centres in 2007-2017 collected from a mandatory administrative database, we identified 466 patients (8% of all tricuspid surgeries) who underwent an ITVS. Most patients presented with advanced disease [47% in New York Heart Association (NYHA) III/IV, 57% with right-sided heart failure (HF) signs]. Tricuspid regurgitation was functional in 49% (22% with prior left-sided heart valve surgery and 27% isolated) and organic in 51% (infective endocarditis in 31% and other causes in 20%). In-hospital mortality and major complications rates were 10% and 31%, respectively. Rates of survival and survival free of HF readmission were 75% and 62% at 5 years. Patients with functional TR incurred a worse in-hospital mortality than those with organic TR (14% vs. 6%, P = 0.004), but presentation was more severe. Independent determinants of outcomes were NYHA Class III/IV [odd ratios (OR) = 2.7 (1.2-6.1), P = 0.01], moderate/severe right ventricular dysfunction [OR = 2.6 (1.2-5.8), P = 0.02], lower prothrombin time [OR = 0.98 (0.96-0.99), P = 0.008], and with borderline statistical significance, right-sided HF signs [OR = 2.4 (0.9-6.5), P = 0.06] while TR mechanism was not [OR = 0.7 (0.3-1.8), P = 0.88]. CONCLUSION: Isolated TV surgery was associated with high mortality and morbidity, both in hospital and during follow-up, predicted by the severity of the presentation but not by TR mechanism. Our results suggest that TV intervention should be performed earlier in the course of the disease.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Disfunção Ventricular Direita , Adulto , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/cirurgia
6.
Br J Haematol ; 180(5): 715-720, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29363751

RESUMO

Heparin anticoagulation followed by protamine reversal is commonly used in cardiopulmonary bypass (CPB). As an alternative to protamine, a recombinant inactive antithrombin (riAT) was designed as an antidote to heparin and was previously shown to be as potent as protamine in-vitro. In the present study, riAT was assessed for its ability to neutralize heparin after CPB in a rat model. After 60 min of CPB under heparin, rats received 5 mg/kg protamine, 37.5 mg/kg riAT or phosphate buffered saline (PBS) as placebo. Residual anticoagulant activity was assessed using the activated partial thromboplastin time assay before, and 10-30 min after reversion. Haemodynamic monitoring was performed and plasma histamine concentration was also measured. In this model, riAT appeared to be as efficient as protamine in neutralizing heparin. Ten minutes after injection, riAT and protamine both decreased heparin activity, to 1.8 ± 1.3 and 4.5 ± 1.4 u/ml, respectively (23.1 ± 5.1 u/ml in placebo group). Furthermore, evolution of mean carotid arterial pressure, heart rate and plasma histamine levels was comparable in rats treated with PBS or riAT, while protamine exhibited haemodynamic side effects and increased histamine plasma concentration. Thus, riAT could represent an advantage over protamine in CPB because it efficiently reverses heparin activity without negative effects on haemodynamic parameters and plasma histamine level.


Assuntos
Anticoagulantes/farmacologia , Ponte Cardiopulmonar , Antagonistas de Heparina/farmacologia , Heparina/farmacologia , Protaminas/farmacologia , Animais , Antitrombinas/farmacologia , Hemodinâmica/efeitos dos fármacos , Histamina/metabolismo , Masculino , Ratos Wistar
7.
Heart Vessels ; 31(11): 1783-1789, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26758734

RESUMO

Interest is growing in the clinical use of sutureless (SU) valves. However, indications in some anatomical sub-settings, like bicuspid aortic valves (BAV), have been so far limited. We discuss herein our initial experience with the implantation of the 3f Enable SU bioprosthesis in patients with a BAV. Patients with a BAV were selected in our unit between March 2011 and September 2014 for a SU 3f Enable valve implantation. Twenty of the 198 patients who underwent a 3f Enable valve implantation in our unit had a BAV. Procedural success was 100 %, but reclamping was necessary in one (5 %) case. Median size of implanted bioprosthesis was 23 mm. After a mean follow-up of 13.8 ± 10.7 months, survival was 100 %. Two patients (10 %) showed an immediate grade 1 paravalvular leak (PVL) that progressed to grade 2 and 3+ (moderate/severe), respectively, during follow-up. Type of bicuspidy (Sievers classification) in these two patients was 0 and intraoperatively aortic annuli admitted the 25 mm calibrator. Among the 18 patients without PVL, no one had a type 0 large BAV. At 1 year, implantation of the 3f Enable SU bioprosthesis appears to be safe in patients with BAV type I and II, while in type 0 use of the SU valve seems to be safe only if the annular diameter is <25 mm. Larger studies are necessary to confirm our findings in order to clarify the indications for SU technology in the subset of bicuspid patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Bioprótese , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos sem Sutura/instrumentação , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Doença da Válvula Aórtica Bicúspide , Feminino , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
8.
Europace ; 15(1): 150-1, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22849975

RESUMO

BACKGROUND: The role of cryoballoon pulmonary vein isolation for the treatment of atrial fibrillation (AF) is unclear. METHODS AND RESULTS: In a 61-year-old man with persistent AF and severe mitral valve regurgitation, surgical cryoballoon pulmonary vein isolation was performed during open-heart surgery, without complication. CONCLUSION: Surgical cryoballoon ablation is feasible and can effectively isolate PV.


Assuntos
Angioplastia com Balão/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Crioterapia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
9.
JACC Case Rep ; 5: 101690, 2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36636511

RESUMO

Percutaneous paravalvular leak closure seems a safe alternative to surgery in frail patients. However, it is a challenging procedure that should be tailored to each patient with optimal imaging guidance. Transesophageal echocardiography during the procedure and computed tomography scan/fluoroscopy fusion provide guidance for critical steps, such as PVL localization and crossing. (Level of Difficulty: Advanced.).

10.
Heart ; 109(12): 951-958, 2023 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-36828623

RESUMO

OBJECTIVES: The TRI-SCORE reliably predicts in-hospital mortality after isolated tricuspid valve surgery (ITVS) on native valve but has not been tested in the setting of redo interventions. We aimed to evaluate the predictive value of the TRI-SCORE for in-hospital mortality in patients with redo ITVS and to compare its accuracy with conventional surgical risk scores. METHODS: Using a mandatory administrative database, we identified all consecutive adult patients who underwent a redo ITVS at 12 French tertiary centres between 2007 and 2017. Baseline characteristics and outcomes were collected from chart review and surgical scores were calculated. RESULTS: We identified 70 patients who underwent a redo ITVS (54±15 years, 63% female). Prior intervention was a tricuspid valve repair in 51% and a replacement in 49%, and was combined with another surgery in 41%. A tricuspid valve replacement was performed in all patients for the redo surgery. Overall, in-hospital mortality and major postoperative complication rates were 10% and 34%, respectively. The TRI-SCORE was the only surgical risk score associated with in-hospital mortality (p=0.005). The area under the receiver operating characteristic curve for the TRI-SCORE was 0.83, much higher than for the logistic EuroSCORE (0.58) or EuroSCORE II (0.61). The TRI-SCORE was also associated with major postoperative complication rates and survival free of readmissions for heart failure. CONCLUSION: Redo ITVS was rarely performed and was associated with an overall high in-hospital mortality and morbidity, but hiding important individual disparities. The TRI-SCORE accurately predicted in-hospital mortality after redo ITVS and may guide clinical decision-making process (www.tri-score.com).


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Adulto , Humanos , Feminino , Masculino , Valva Tricúspide/cirurgia , Mortalidade Hospitalar , Implante de Prótese de Valva Cardíaca/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Fatores de Risco , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 23(7): 778-80, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22783945

RESUMO

Left phrenic nerve stimulation is a well-known complication of cardiac resynchronization therapy (CRT). We report a case where electronic or anatomical repositioning of the left ventricular (LV) electrode (within the coronary sinus tributaries) was not feasible/effective. Surgical graft interpositioning was performed to successfully isolate the phrenic nerve from the previously implanted coronary sinus epicardial LV lead.


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Diafragma/inervação , Contração Muscular , Nervo Frênico/cirurgia , Toracoscopia , Dispositivos de Terapia de Ressincronização Cardíaca , Desenho de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade , Nervo Frênico/diagnóstico por imagem , Toracoscopia/instrumentação , Tomografia Computadorizada por Raios X , Resultado do Tratamento
12.
J Heart Valve Dis ; 21(5): 679-81, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23167235

RESUMO

The durability of a Starr-Edwards valve implanted in the tricuspid position in 1967 to treat Ebstein's disease with tricuspid valve regurgitation. At surgery, cardiac permanent pacing for postoperative complete atrioventricular block was achieved using a nuclear-powered pacemaker (NP). Although the 43rd year of cardiologic follow up was free from complications, the patient--a 74-year-old woman--suffered symptomatic mitral regurgitation and underwent a redo mitral valve replacement, during which the Starr-Edwards valve and NP were left in place.


Assuntos
Anomalia de Ebstein/cirurgia , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Valva Tricúspide , Adulto , Idoso , Feminino , Humanos , Reoperação
13.
Artif Organs ; 36(11): 962-71, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22888788

RESUMO

The aim of this study was to investigate the potential anti-inflammatory and endothelial protective properties of albumin during cardiopulmonary bypass (CPB) in an experimental porcine model. Two groups underwent CPB for 90 min (n = 7 in each group), and a baseline (BL) control group did not undergo CPB (n = 7). Priming consisted of a gelatin solution (4% gelofusine, CPBG group) or colloid solution (5% albumin, CPBA group). Mesenteric arterial segments were isolated and exposed in vitro to phenylephrine (with or without nitric oxide synthase inhibition) to assess contractility, and exposed to acetylcholine and sodium nitroprusside to assess relaxation. Plasma tumor necrosis factor (TNF)-α levels, intestinal and pulmonary TNF-α and heme oxygenase (HO)-1 mRNA expression, and organ injury were studied. Upon sacrifice, TNF-α levels were significantly higher in the CPBG group than in the CPBA and BL groups. The contractile response was significantly higher in the CPBG group, whereas the response to acetylcholine was significantly lower in the CPBG group than in the other groups. HO-1 mRNA expression was significantly higher in intestine samples in the CPBA group than in the CPBG and BL groups. HO-1 mRNA expression was significantly higher in lung samples in the CPBA group than in the CPBG group. Leukocyte infiltration was significantly higher in intestine and lung samples in the CPBG group than in the CPBA and BL groups. Albumin priming reduced CPB-induced mesenteric vascular dysfunction and prevented the development of a systemic inflammatory response by modeling HO-1 expression in target organs.


Assuntos
Anti-Inflamatórios/uso terapêutico , Ponte Cardiopulmonar/métodos , Artérias Mesentéricas/efeitos dos fármacos , Albumina Sérica/uso terapêutico , Fator de Necrose Tumoral alfa/imunologia , Animais , Endotélio Vascular/efeitos dos fármacos , Endotélio Vascular/fisiopatologia , Expressão Gênica/efeitos dos fármacos , Heme Oxigenase-1/genética , Humanos , Mucosa Intestinal/metabolismo , Intestinos/efeitos dos fármacos , Intestinos/imunologia , Intestinos/patologia , Pulmão/efeitos dos fármacos , Pulmão/imunologia , Pulmão/metabolismo , Pulmão/patologia , Artérias Mesentéricas/fisiopatologia , RNA Mensageiro/genética , Suínos , Fator de Necrose Tumoral alfa/genética , Vasoconstrição/efeitos dos fármacos
14.
J Card Surg ; 27(5): 647-9, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22757636

RESUMO

Tachycardia-mediated cardiomyopathy associated with cardiogenic shock is a rare but well-known entity. We report an unusual case of cardiogenic shock with atrial tachycardia in postpartum; the patient underwent successful radiofrequency ablation under extracorporeal membrane oxygenation (ECMO). Radiofrequency ablation is usually used to treat this clinical situation. The use of ECMO has been described only in pediatric case.


Assuntos
Ablação por Cateter/métodos , Oxigenação por Membrana Extracorpórea/métodos , Complicações Cardiovasculares na Gravidez/terapia , Resultado da Gravidez , Taquicardia Supraventricular/terapia , Cesárea/métodos , Terapia Combinada , Eletrocardiografia/métodos , Feminino , Seguimentos , Idade Gestacional , Humanos , Período Pós-Parto , Gravidez , Complicações Cardiovasculares na Gravidez/diagnóstico , Medição de Risco , Taquicardia Supraventricular/diagnóstico
15.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35583290

RESUMO

OBJECTIVES: Despite growing evidence that aortic valve repair improves long-term patient outcomes and quality of life, aortic valves are mostly replaced. We evaluate the effect of aortic valve repair versus replacement in patients with dystrophic aortic root aneurysm up to 4 years. METHODS: The multicentric CAVIAAR (Conservation Aortique Valvulaire dans les Insuffisances Aortiques et les Anévrismes de la Racine aortique) prospective cohort study enrolled 261 patients: 130 underwent standardized aortic valve repair (REPAIR) consisting of remodelling root repair with expansible aortic ring annuloplasty, and 131 received mechanical composite valve and graft replacement (REPLACE). Primary outcome was a composite criterion of mortality, reoperation, thromboembolic or major bleeding events, endocarditis or operating site infections, pacemaker implantation and heart failure, analysed with propensity score-weighted Cox model analysis. Secondary outcomes included major adverse valve-related events and components of primary outcome. RESULTS: The mean age was 56.1 years, and valve was bicuspid in 115 patients (44.7%). Up to 4 years, REPAIR did not significantly differ from REPLACE in terms of primary outcome [Hazard Ratio (HR) 0.66 (0.39; 1.12)] but showed significantly less valve-related deaths (HR 0.09 [0.02; 0.34]) and major bleeding events (HR 0.37 [0.16; 0.85]) without an increased risk of valve-related reoperation (HR 2.10 [0.64; 6.96]). When accounting for the occurrence of multiple events in a single patient, the REPAIR group had half the occurrence of major adverse valve-related events (HR 0.51 [0.31; 0.86]). CONCLUSIONS: Although the primary outcome did not significantly differ between the REPAIR and REPLACE groups, the trend is in favour of REPAIR by a significant reduction of valve-related deaths and major bleeding events. Long-term follow-up beyond 4 years is needed to confirm these findings.


Assuntos
Aneurisma Aórtico , Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Humanos , Pessoa de Meia-Idade , Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/efeitos adversos , Aneurisma Aórtico/cirurgia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Reoperação/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Retrospectivos
18.
J Cardiothorac Surg ; 16(1): 160, 2021 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-34088318

RESUMO

BACKGROUND: The ACURATE neo™ transcatheter heart valve (Boston Scientific, Marlborough, Massachusetts) is predominantly implanted via femoral access. Transcarotid use of this prothesis has never been reported. CASE PRESENTATION: We present the case of an 89-year-old woman referred to us for a transcatheter aortic valve replacement (TAVR). After apparatus imaging of the aortic annulus and the peripheral vascular pathway, the heart team was confronted with a triple challenge: (i) The preferable choice of a self-expanding valve because of a small aortic annulus in an obese woman. (ii) Gaining favorable access to the coronary ostia, considering multiple recent coronary stenting. (iii) Utilizing an alternative arterial access because of iliac and femoral severely calcified stenosis. Implanting the ACURATE neo™ transcatheter heart valve (THV) via carotidal access allowed us to overcome these challenges. The procedure was performed successfully without any short-term complications. CONCLUSION: We report the first case of implantation of an ACURATE neo™ transcatheter heart valve (Boston Scientific, Marlborough, Massachusetts) via the right common carotid artery.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Artéria Carótida Primitiva/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Feminino , Humanos , Substituição da Valva Aórtica Transcateter/instrumentação
19.
Eur J Cardiothorac Surg ; 59(5): 1037-1047, 2021 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-33276375

RESUMO

OBJECTIVES: Endothelial dysfunction during ischaemia-reperfusion (IR) is a major cause of primary graft dysfunction during lung transplantation. The routine use of cardiopulmonary bypass (CPB) during lung transplantation remains controversial. However, the contribution of CPB to pulmonary endothelial dysfunction remains unclear. The objective was to investigate the impact of CPB on endothelial dysfunction in a lung IR rat model. METHODS: Rats were allocated to 4 groups: (i) Sham, (ii) IR, (iii) CPB and (iv) IR-CPB. The primary outcome was the study of pulmonary vascular reactivity by wire myograph. We also assessed glycocalyx degradation by enzyme-linked immunosorbent assay and electron microscopy and both systemic and pulmonary inflammation by enzyme-linked immunosorbent assay and immunohistochemistry. Rats were exposed to 45 min of CPB and IR. We used a CPB model allowing femoro-femoral support with left pulmonary hilum ischaemia for IR. RESULTS: Pulmonary endothelium-dependent relaxation to acetylcholine was markedly reduced in the IR-CPB group (10.7 ± 9.1%) compared to the IR group (50.5 ± 5.2%, P < 0.001), the CPB group (54.1 ± 4.7%, P < 0.001) and the sham group (80.8 ± 6.7%, P < 0.001), suggesting that the association of pulmonary IR and CPB increases endothelial dysfunction. In IR-CPB, IR and CPB groups, vasorelaxation was completely abolished when inhibiting nitric oxide synthase, suggesting that this relaxation process was mainly mediated by nitric oxide. We observed higher syndecan-1 plasma levels in the IR-CPB group in comparison with the other groups, reflecting an increased degradation of glycocalyx. We also observed higher systemic inflammation in the IR-CPB group as shown by the increased plasma levels of IL-1ß, IL-10. CONCLUSIONS: CPB significantly increased the IR-mediated effects on pulmonary endothelial dysfunction. Therefore, the use of CPB during lung transplantation could be deleterious, by increasing endothelial dysfunction.


Assuntos
Ponte Cardiopulmonar , Endotélio Vascular , Animais , Isquemia , Pulmão , Ratos , Reperfusão
20.
Front Cardiovasc Med ; 8: 827515, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35127877

RESUMO

BACKGROUND: European surgeons were the first worldwide to use robotic techniques in cardiac surgery and major steps in procedure development were taken in Europe. After a hype in the early 2000s case numbers decreased but due to technological improvements renewed interest can be noted. We assessed the current activities and outcomes in robotically assisted cardiac surgery on the European continent. METHODS: Data were collected in an international anonymized registry of 26 European centers with a robotic cardiac surgery program. RESULTS: During a 4-year period (2016-2019), 2,563 procedures were carried out [30.0% female, 58.5 (15.4) years old, EuroSCORE II 1.56 (1.74)], including robotically assisted coronary bypass grafting (n = 1266, 49.4%), robotic mitral or tricuspid valve surgery (n = 945, 36.9%), isolated atrial septal defect closure (n = 225, 8.8%), left atrial myxoma resection (n = 54, 2.1%), and other procedures (n = 73, 2.8%). The number of procedures doubled during the study period (from n = 435 in 2016 to n = 923 in 2019). The mean cardiopulmonary bypass time in pump assisted cases was 148.6 (63.5) min and the myocardial ischemic time was 88.7 (46.1) min. Conversion to larger thoracic incisions was required in 56 cases (2.2%). Perioperative rates of revision for bleeding, stroke, and mortality were 56 (2.2%), 6 (0.2 %), and 27 (1.1%), respectively. Median postoperative hospital length of stay was 6.6 (6.6) days. CONCLUSION: Robotic cardiac surgery case numbers in Europe are growing fast, including a large spectrum of procedures. Conversion rates are low and clinical outcomes are favorable, indicating safe conduct of these high-tech minimally invasive procedures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA