1.
J Cardiovasc Electrophysiol ; 32(4): 941-948, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33527562

RESUMO

Catheter ablation is an established effective approach for the treatment of atrial fibrillation (AF) in patients with heart failure, however, the role of cryoablation in this setting is unclear. Procedural success and left ventricular systolic dysfunction (LVEF) improvement in patients with LVEF ≤ 45% undergoing index catheter ablation with cryoablation were evaluated. Freedom from AF recurrence was seen in 43% rising to 59% following repeat procedure. There were significant improvements in LVEF and functional status at long-term follow-up. Results were comparable to a contemporaneous cohort of heart failure patients undergoing index ablation with radiofrequency ablation. Cryoablation is an effective first-line AF ablation approach in the setting of heart failure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Insuficiência Cardíaca Sistólica , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 29(3): 395-403, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29364554

RESUMO

INTRODUCTION: This study sought to validate a novel wavefront mapping system utilizing whole-chamber basket catheters (CARTOFINDER, Biosense Webster). The system was validated in terms of (1) mapping atrial-paced beats and (2) mapping complex wavefront patterns in atrial tachycardia (AT). METHODS AND RESULTS: Patients undergoing catheter ablation for AT and persistent AF were included. A 64-pole-basket catheter was used to acquire unipolar signals that were processed by CARTOFINDER mapping system to generate dynamic wavefront propagation maps. The left atrium was paced from four sites to demonstrate focal activation. ATs were mapped with the mechanism confirmed by conventional mapping, entrainment, and response to ablation. Twenty-two patients were included in the study (16 with AT and 6 with AF initially who terminated to AT during ablation). In total, 172 maps were created with the mapping system. It correctly identified atrial-pacing sites in all paced maps. It accurately mapped 9 focal/microreentrant and 18 macroreentrant ATs both in the left and right atrium. A third and fourth observer independently identified the sites of atrial pacing and the AT mechanism from the CARTOFINDER maps, while being blinded to the conventional activation maps. CONCLUSIONS: This novel mapping system was effectively validated by mapping focal activation patterns from atrial-paced beats. The system was also effective in mapping complex wavefront patterns in a range of ATs in patients with scarred atria. The system may therefore be of practical use in the mapping and ablation of AT and could have potential for mapping wavefront activations in AF.


Assuntos
Potenciais de Ação , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Supraventricular/diagnóstico , Idoso , Cateteres Cardíacos , Estimulação Cardíaca Artificial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
4.
Int J Cardiol ; 278: 114-119, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30391065

RESUMO

BACKGROUND: Low voltage zones (LVZs) are associated with conduction velocity (CV) slowing. Rate-dependent CV slowing may play a role in reentry mechanisms. METHODS: Patients undergoing catheter ablation for AT were enrolled. Aim was to assess the relationship between rate-dependent CV slowing and sites of localized reentrant atrial tachycardias (AT). On a bipolar voltage map regions were defined as non-LVZs [≥0.5 mV], LVZs [0.2-0.5 mV] and very-LVZs [<0.2 mV]. Unipolar electrograms were recorded with a 64-pole basket catheter during uninterrupted atrial pacing at four pacing intervals (PIs) during sinus rhythm. CVs were measured between pole pairs along the wavefront path. Sites of rate-dependent CV slowing were defined as exhibiting a reduction in CV between PI = 600 ms and 250 ms of ≥20% more than the mean CV reduction seen between these PIs for that voltage zone. Rate-dependent CV slowing sites were correlated to sites of localized reentrant ATs as confirmed with conventional mapping, entrainment and response to ablation. RESULTS: Eighteen patients were included (63 ±â€¯10 years). Mean CV at 600 ms was 1.53 ±â€¯0.19 m/s in non-LVZs, 1.14 ±â€¯0.15 m/s in LVZs, and 0.73 ±â€¯0.13 m/s in very-LVZs respectively (p < 0.001). Rate-dependent CV slowing sites were predominantly in LVZs [0.2-0.5 mV] (74.4 ±â€¯10.3%; p < 0.001). Localized reentrant ATs were mapped to these sites in 81.8% of cases (sensitivity 81.8%, 95% CI 48.2-97.9% and specificity 83.9%, 95% CI 81.8-86.0%). Macro-reentrant or focal ATs were not mapped to sites of rate-dependent CV slowing. CONCLUSIONS: Rate-dependent CV slowing sites are predominantly confined to LVZs [0.2-0.5 mV] and the resultant CV heterogeneity may promote reentry mechanisms. These may represent a novel adjunctive target for AT ablation.


Assuntos
Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/tendências , Feminino , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos
5.
J Interv Card Electrophysiol ; 56(2): 199-203, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29858762

RESUMO

PURPOSE: Audit has played a key role in monitoring and improving clinical practice. However, audit often fails to drive change as summative institutional data alone may be insufficient to do so. We hypothesised that the practice of attributed audit, wherein each individual's procedural performance is presented will have a greater impact on clinical practice. This hypothesis was tested in an observational study evaluating improvement in fluoroscopy times for AF ablation. METHODS: Retrospective analyses of fluoroscopy times in AF ablations at the Barts Heart Centre (BHC) from 2012-2017. Fluoroscopy times were compared pre- and post- the introduction of attributed audit in 2012 at St Bartholomew's Hospital (SBH). In order to test the hypothesis, this concept was introduced to a second group of experienced operators from the Heart Hospital (HH) as part of a merger of the two institutions in 2015 and change in fluoroscopy times recorded. RESULTS: A significant drop in fluoroscopy times (33.3 ± 9.14 to 8.95 ± 2.50, p < 0.0001) from 2012-2014 was noted after the introduction of attributed audit. At the time of merger, a significant difference in fluoroscopy times between operators from the two centres was seen in 2015. Each operator's procedural performance was shared openly at the audit meeting. Subsequent audits showed a steady decrease in fluoroscopy times for each operator with the fluoroscopy time (min, mean±SD) decreasing from 13.29 ± 7.3 in 2015 to 8.84 ± 4.8 (p < 0.0001) in 2017 across the entire group. CONCLUSIONS: Systematic improvement in fluoroscopy times for AF ablation procedures was noted byevaluating individual operators' performance. Attributing data to physicians in attributed audit can promptsignificant improvement and hence should be adopted in clinical practice.


Assuntos
Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas/normas , Auditoria Médica , Ablação por Cateter , Estudos Transversais , Feminino , Fluoroscopia , Humanos , Londres , Masculino , Duração da Cirurgia , Melhoria de Qualidade , Radiografia Intervencionista , Estudos Retrospectivos
7.
J Interv Card Electrophysiol ; 19(2): 129-32, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17674170

RESUMO

We present a case of a 21-year-old female with congenitally corrected transposition of the great vessels and episodes of supraventricular tachycardia. We performed an electrophysiological study and successful ablation using an electro-anatomical mapping system. A single His bundle appeared to be located at the apex of the triangle of Koch and at electrophysiological study there was evidence of triple antegrade AV nodal pathways--slow, intermediate and fast, with two types of AV nodal re-entrant tachycardias. A series of radiofrequency ablations in the right posteroseptal area eliminated both slow and intermediate pathway conduction and cured the tachycardias.


Assuntos
Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/cirurgia , Adulto , Vasos Sanguíneos/fisiopatologia , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter , Anormalidades Congênitas/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Radiocirurgia , Taquicardia por Reentrada no Nó Atrioventricular/etiologia , Taquicardia Supraventricular/etiologia , Transposição dos Grandes Vasos/complicações
8.
Heart ; 103(15): 1210-1215, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28249993

RESUMO

OBJECTIVE: Cardiac electrophysiology (EP) procedures can be performed under moderate sedation without the direct involvement of an anaesthetist. However, concerns have been raised over the safety of this approach. This study examines the use of a standardised nurse-led physician-directed sedation protocol for EP procedures to determine the safety of moderate sedation administered by non-anaesthesia personnel who have been trained in sedation techniques. METHODS AND RESULTS: Consecutive EP procedures done under moderate sedation over 12 years at our institution were evaluated. Serious adverse events were defined as (i) procedural death related to sedation; (ii) intubation and ventilation; and (iii) hypotension requiring inotropic support. Reversal of sedation constituted a minor adverse event. Up to 7117 procedures were included. These comprised ablations (55%), devices (43%) and other procedures (2%). A majority of patients were men with a mean age of 61±10 years. 99.98% of procedures were completed successfully without sedation-related serious adverse events. Two patients (0.02%) required anaesthetic support for intubation. Sedation was reversed in 1.2% of procedures with less than 1% requiring reversal because of persistent drop in oxygen saturation, hypoventilation or markedly reduced level of consciousness. There was no significant difference in the patient characteristics, mean doses of sedative agents and procedure types in the group requiring reversal of sedation when compared with the whole cohort. CONCLUSIONS: Our study demonstrates that nurse-led, physician-directed moderate sedation is safe. Anaesthesia services are not required routinely for invasive cardiac EP procedures and should be available on a need basis.


Assuntos
Eletrofisiologia Cardíaca/métodos , Procedimentos Cirúrgicos Cardíacos , Sedação Consciente/métodos , Monitorização Fisiológica/métodos , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
9.
Heart ; 103(18): 1413-1418, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-27613170

RESUMO

INTRODUCTION: Supraventricular tachycardias (SVTs) are a common cause of acute hospital presentations. Adenosine is an effective treatment. To date, no studies have directly compared paramedic-with hospital-delivered treatment of acute SVT with adenosine. METHOD: Randomised controlled trial comparing the treatment of SVT and discharge by paramedics with conventional emergency department (ED)-based care. Patients were excluded if they had structural heart disease or contraindication to adenosine. Discharge time, follow-up management, costs and patient satisfaction were compared. RESULTS: Eighty-six patients were enrolled: 44 were randomised to paramedic-delivered adenosine (PARA) and 42 to conventional care (ED). Of the 37 patients in the PARA group given adenosine, the tachycardia was successfully terminated in 81%. There was a 98% correlation between the paramedics' ECG diagnosis and that of two electrophysiologists. No patients had any documented adverse events in either group. The discharge time was lower in the PARA group than in the ED group (125 min (range 55-9513) vs 222 min (range 72-26 153); p=0.01), and this treatment strategy was more cost-effective (£282 vs £423; p=0.01). The majority of patients preferred this management approach. Being treated and discharged by paramedics did not result in the patients being less likely to receive ongoing management of their arrhythmia and cardiology follow-up. CONCLUSIONS: Patients with SVT can effectively and safely be treated with adenosine delivered by trained paramedics. Implementation of paramedic-delivered acute SVT care has the potential to reduce healthcare costs without compromising patient care. TRIAL REGISTRATION NUMBER: NCT02216240.


Assuntos
Adenosina/administração & dosagem , Pessoal Técnico de Saúde , Eletrocardiografia/efeitos dos fármacos , Serviços Médicos de Emergência/métodos , Satisfação do Paciente , Taquicardia Supraventricular/tratamento farmacológico , Antiarrítmicos/administração & dosagem , Análise Custo-Benefício , Relação Dose-Resposta a Droga , Serviços Médicos de Emergência/economia , Serviço Hospitalar de Emergência , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Supraventricular/economia , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
10.
Int J Cardiol ; 228: 280-285, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27865198

RESUMO

BACKGROUND: Subcutaneous implantable cardioverter defibrillators (S-ICD) have become more widely available. However, comparisons with conventional transvenous ICDs (TV-ICD) are scarce. METHODS: We conducted a propensity matched case-control study including all patients that underwent S-ICD implantation over a five-year period in a single tertiary centre. Controls consisted of all TV-ICD implant patients over a contemporary time period excluding those with pacing indication, biventricular pacemakers and those with sustained monomorphic ventricular tachycardia requiring anti-tachycardia pacing. Data was collected on device-related complications and mortality rates. A cost efficacy analysis was performed. RESULTS: Sixty-nine S-ICD cases were propensity matched to 69 TV-ICD controls. During a mean follow-up of 31±19 (S-ICD) and 32±21months (TV-ICD; p=0.88) there was a higher rate of device-related complications in the TV-ICD group predominantly accounted for by lead failures (n=20, 29% vs. n=6, 9%; p=0.004). The total mean cost for each group, including the complication-related costs was £9967±4511 ($13,639±6173) and £12,601±1786 ($17,243±2444) in the TV-ICD and S-ICD groups respectively (p=0.0001). Even though more expensive S-ICD was associated with a relative risk reduction of device-related complication of 70% with a HR of 0.30 (95%CI 0.12-0.76; p=0.01) compared to TV-ICDs. CONCLUSIONS: TV-ICDs are associated with increased device-related complication rates compared to a propensity matched S-ICD group during a similar follow-up period. Despite the existing significant difference in unit cost of the S-ICD, overall S-ICD costs may be mitigated versus TV-ICDs over a longer follow-up period.


Assuntos
Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/terapia , Análise Custo-Benefício , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/métodos , Segurança do Paciente , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Estudos de Casos e Controles , Causas de Morte , Desfibriladores Implantáveis/economia , Cardioversão Elétrica/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Pontuação de Propensão , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/terapia , Resultado do Tratamento
11.
Br J Hosp Med (Lond) ; 77(8): 460-6, 2016 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-27487056

RESUMO

The management of atrial fibrillation extends from stroke prevention to rate or rhythm control strategies. The role of an invasive strategy is expanding and it remains important to identify suitable candidates early in the disease process.


Assuntos
Fibrilação Atrial/terapia , Antiarrítmicos/uso terapêutico , Anticoagulantes/uso terapêutico , Ablação por Cateter , Gerenciamento Clínico , Cardioversão Elétrica , Humanos
12.
Int J Cardiol ; 222: 57-61, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27454616

RESUMO

BACKGROUND: Current guidelines for epicardial catheter ablation for ventricular tachycardia (VT) advocate that epicardial access is avoided in anticoagulated patients and should be performed prior to heparinisation. Recent studies have shown that epicardial access may be safe in heparinised patients. However, no data exist for patients on oral anticoagulants. We investigated the safety of obtaining epicardial access on uninterrupted warfarin. METHODS: A prospective registry of patients undergoing epicardial VT ablation over two years was analysed. Consecutive patients in whom epicardial access was attempted were included. All patients were heparinised prior to epicardial access with a target activated clotting time (ACT) of 300-350s. Patients who had procedures performed on uninterrupted warfarin (in addition to heparin) were compared to those not taking an oral anticoagulant. RESULTS: 46 patients were included of which 13 were taking warfarin. There was no significant difference in clinical and procedural characteristics (except INR and AF) between the two groups. Epicardial access was achieved in all patients. There were no deaths and no patients required surgery. A higher proportion of patients in the warfarin group had a drop in haemoglobin of >2g/dL compared to the no-warfarin group (38.5% versus 27.3%, p=0.74) and delayed pericardial drain removal (7.8% versus 3.03%, p=0.47). There was no difference in overall procedural complication rate. No patients required warfarin reversal or blood transfusion. CONCLUSION: Epicardial access can be achieved safely and effectively in patients' anticoagulated with warfarin and heparinised with therapeutic ACT. This may be an attractive option for patients with a high stroke risk.


Assuntos
Ablação por Cateter , Heparina , Complicações Intraoperatórias/prevenção & controle , Pericárdio/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Acidente Vascular Cerebral , Taquicardia Ventricular , Varfarina , Idoso , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Heparina/administração & dosagem , Heparina/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória/métodos , Assistência Perioperatória/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/cirurgia , Reino Unido , Varfarina/administração & dosagem , Varfarina/efeitos adversos
13.
Int J Cardiol ; 207: 157-63, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26803233

RESUMO

BACKGROUND: Implantable cardioverter defibrillators (ICDs) reduce mortality in patients with ischaemic cardiomyopathy at high risk of ventricular arrhythmias (VA). However, the current indication for ICD prescription needs improvement. Telomere and telomerase in leucocytes have been shown to associate with biological ageing and pathogenesis of cardiovascular diseases. We hypothesised that leucocyte telomere length, load-of-short telomeres and/or telomerase activity are associated with VA occurrence in ischaemic cardiomyopathy patients. METHODS AND RESULTS: 90 ischaemic cardiomyopathy patients with primary prevention ICDs were recruited. 35 had received appropriate therapy from the ICD for potentially-fatal VA while the remaining 55 patients had not. No significant differences in baseline demographic data relevant to telomere biology were seen between the two groups. There was no significant difference in the age and sex adjusted mean telomere length analysed by qPCR between the groups (p=0.88). In contrast, the load-of-short telomeres assessed by Universal-STELA method and telomerase activity by TRAP assay were both higher in patients who had appropriate ICD therapy and were significantly associated with incidence of ICD therapy (p=0.02, p=0.02). ROC analyses demonstrated that the sensitivity and specificity of these telomere dynamics in predicting potentially-fatal VA was higher than the current gold-standard - left ventricular ejection fraction (AUC 0.82 versus 0.47). CONCLUSION: The load-of-short telomeres and telomerase activity had a significant association with ICD therapy (for VA) in ischaemic cardiomyopathy patients. These biomarkers should be tested in prospective studies to assess their clinical utility in predicting VA after myocardial infarction and guiding primary prevention ICD prescription.


Assuntos
Cardiomiopatias/metabolismo , Desfibriladores Implantáveis , Isquemia Miocárdica/metabolismo , Taquicardia Ventricular/metabolismo , Telomerase/metabolismo , Encurtamento do Telômero/fisiologia , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Biomarcadores/metabolismo , Cardiomiopatias/diagnóstico , Cardiomiopatias/terapia , Estudos de Casos e Controles , Estudos Transversais , Ativação Enzimática/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/terapia , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Telomerase/sangue
14.
J Hand Surg Br ; 11(2): 163-74, 1986 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-3734551

RESUMO

A detailed examination of twenty cadaver hands has been carried out in order to elucidate the arterial blood supply of the thumb, first web, and index finger, relating this to revascularization, replantation and possible flaps in that area. The vessels are described in turn, and it is demonstrated that the terms "princeps pollicis" and "arteria radialis indicis" are misnomers. The results of the dissections are compared to those of others and the differences recorded.


Assuntos
Dedos/irrigação sanguínea , Polegar/irrigação sanguínea , Artérias/anatomia & histologia , Cadáver , Dedos/cirurgia , Humanos , Reimplante , Retalhos Cirúrgicos , Polegar/cirurgia
15.
J Hand Surg Br ; 14(4): 434-40, 1989 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2482855

RESUMO

Eleven patients have had second dorsal metacarpal sensate island flaps used to cover local skin defects in the hand. The arterial supply is reliable but if the flap is extended beyond the proximal interphalangeal joint, distal flap necrosis or donor site difficulties may occur. Possible applications for this flap are demonstrated and some untried variations to increase its range are suggested. Its main use appears to be in the release of first web contractures and for resurfacing radio-palmar and thumb defects.


Assuntos
Artérias/cirurgia , Dedos/cirurgia , Mãos/cirurgia , Retalhos Cirúrgicos , Adolescente , Adulto , Idoso , Criança , Dedos/irrigação sanguínea , Mãos/irrigação sanguínea , Humanos , Métodos , Músculos/cirurgia , Neovascularização Patológica
16.
J Hand Surg Br ; 14(1): 65-9, 1989 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2926226

RESUMO

Cadaveric dissections demonstrated a constant blood supply to the skin of the first web. An island advancement flap from the dorsum of the first web was used to release first web contractures in six patients and to resurface palmar burns in two. There were no flap losses and its use is recommended in release of moderate contractures and minor loss of palmar skin.


Assuntos
Mãos/cirurgia , Retalhos Cirúrgicos , Adolescente , Adulto , Idoso , Queimaduras por Corrente Elétrica/cirurgia , Criança , Contratura/cirurgia , Mãos/irrigação sanguínea , Humanos , Métodos , Pessoa de Meia-Idade , Pele/irrigação sanguínea
17.
J Hand Surg Br ; 10(3): 347-50, 1985 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-4078464

RESUMO

Revascularisation of a thumb pulp by restoring volar venous drainage is described, stressing the need to search for volar veins in distal replants or revascularisations. The literature describing digital volar venous drainage is reviewed and the author's own findings during the course of dissecting twenty thumbs are presented.


Assuntos
Amputação Traumática/cirurgia , Microcirurgia , Polegar/lesões , Acidentes de Trabalho , Humanos , Masculino , Pessoa de Meia-Idade , Reimplante , Polegar/irrigação sanguínea , Veias/anatomia & histologia , Veias/transplante
18.
J Hand Surg Br ; 9(1): 98-102, 1984 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-6707514

RESUMO

Of 40 patients with amputated thumbs referred for replantation to the Manchester Microsurgical Unit over five and a half years, 10 (25%) were not considered to be feasible replants, 6(15%) were abandoned at the primary operation, and 24 were replanted. Mode of selection of patients for replantation and operative methods are considered. The 14 thumb replants that survived were studied in detail and functional results are presented. Only one patient had a result that prevented normal activities, the remainder having returned to former occupations.


Assuntos
Amputação Traumática/cirurgia , Reimplante , Polegar/cirurgia , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Métodos , Pessoa de Meia-Idade , Cuidados Pós-Operatórios , Reoperação , Polegar/lesões , Polegar/fisiologia
19.
J Hand Surg Br ; 18(3): 285-8, 1993 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8345250

RESUMO

Congenital pseudarthrosis of the ulna is an extremely rare condition for which current surgical techniques have been unsatisfactory in restoring a normal two-bone forearm. We report a case which was treated by excision of the ulnar pseudarthrosis and interposition of a free vascularized fibular graft with a skin island to monitor anastomotic patency. Forearm rotation has been restored and the potential for normal forearm growth has been preserved.


Assuntos
Fíbula/transplante , Pseudoartrose/cirurgia , Ulna/lesões , Feminino , Humanos , Lactente , Pseudoartrose/congênito , Pseudoartrose/diagnóstico por imagem , Radiografia
20.
J Hand Surg Br ; 20(4): 505-8, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7594994

RESUMO

The risks of foreign implantation may be avoided in tendon repair by the use of absorbable sutures, for example polydioxanone. In this study, the in vivo tensile strength half-life of 4/0 polydioxanone was found to be approximately 4 weeks. Using a rabbit model, we compared polydioxanone tendon repairs with polypropylene tendon repairs. Unilateral flexor digitorum longus repairs were performed on 46 rabbits using either polydioxanone or polypropylene. Tendons were harvested at 3 days, 2 weeks and 4 weeks and the tensile breaking strengths were obtained. 30 intact rabbit flexor digitorum longus tendons and 20 freshly repaired tendons were also tested. By 4 weeks, the repair strength had increased eight-fold from approximately 20 N to 166 N. The sutures made little contribution to the overall strength of a 4-week-old repair. There was no significant difference between polydioxanone and polypropylene repairs at any stage. These results show that polydioxanone repairs were as strong as polypropylene during the first critical weeks of tendon healing.


Assuntos
Polidioxanona , Polipropilenos , Suturas , Tendões/cirurgia , Absorção , Animais , Feminino , Masculino , Coelhos , Resistência à Tração , Fatores de Tempo , Cicatrização
SELEÇÃO DE REFERÊNCIAS