Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Magn Reson Imaging ; 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39165139

RESUMO

BACKGROUND: Magnetic resonance elastography (MRE) can quantify tissue biomechanics noninvasively, including pathological hepatic states like metabolic dysfunction-associated steatohepatitis. PURPOSE: To compare the performance of 2D/3D-MRE using the gravitational (GT) transducer concept with the current commercial acoustic (AC) solution utilizing a 2D-MRE approach. Additionally, quality index markers (QIs) were proposed to identify image pixels with sufficient quality for reliably estimating tissue biomechanics. STUDY TYPE: Prospective. POPULATION: One hundred seventy participants with suspected or confirmed liver disease (median age, 57 years [interquartile range (IQR), 46-65]; 66 females), and 11 healthy volunteers (median age, 31 years [IQR, 27-34]; 5 females). FIELD STRENGTH/SEQUENCE: Participants were scanned twice at 1.5 T and 60 Hz vibration frequency: first, using AC-MRE (2D-MRE, spin-echo EPI sequence, 11 seconds breath-hold), and second, using GT-MRE (2D- and 3D-MRE, gradient-echo sequence, 14 seconds breath-hold). ASSESSMENT: Image analysis was performed by four independent radiologists and one biomedical engineer. Additionally, superimposed analytic plane shear waves of known wavelength and attenuation at fixed shear modulus were used to propose pertinent QIs. STATISTICAL TESTS: Spearman's correlation coefficient (r) was applied to assess the correlation between modalities. Interreader reproducibility was evaluated using Bland-Altman bias and reproducibility coefficients. P-values <0.05 were considered statistically significant. RESULTS: Liver stiffness quantified via GT-2D/3D correlated well with AC-2D (r ≥ 0.89 [95% CI: 0.85-0.92]) and histopathological grading (r ≥ 0.84 [95% CI: 0.72-0.91]), demonstrating excellent agreement in Bland-Altman plots and between readers (κ ≥ 0.86 [95% CI: 0.81-0.91]). However, GT-2D showed a bias in overestimating stiffness compared to GT-3D. Proposed QIs enabled the identification of pixels deviating beyond 10% from true stiffness based on a combination of total wave amplitude, temporal sinusoidal nonlinearity, and wave signal-to-noise ratio for GT-3D. CONCLUSION: GT-MRE represents an alternative to AC-MRE for noninvasive liver tissue characterization. Both GT-2D and 3D approaches correlated strongly with the established commercial approach, offering advanced capabilities in abdominal imaging compared to AC-MRE. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

2.
J Thromb Thrombolysis ; 57(6): 996-1007, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38762707

RESUMO

An accurate diagnosis of venous thromboembolism (VTE) is crucial, given the potential for high mortality in undetected cases. Strategic D-dimer testing may aid in identifying low-risk patients, preventing overdiagnosis and reducing imaging costs. We conducted a retrospective, comparative analysis to assess the potential cost savings that could be achieved by adopting different approaches to determine the most effective D-dimer cut-off value in cancer patients with suspected VTE, compared to the commonly used rule-out cut-off level of 0.5 mg/L. The study included 526 patients (median age 65, IQR 55-75) with a confirmed cancer diagnosis who underwent D-dimer testing. Among these patients, the VTE prevalence was 29% (n = 152). Each diagnostic strategy's sensitivity, specificity, negative likelihood ratio (NLR), as well as positive likelihood ratio (PLR), and the proportion of patients exhibiting a negative D-dimer test result, were calculated. The diagnostic strategy that demonstrated the best balance between specificity, sensitivity, NLR, and PLR, utilized an inverse age-specific cut-off level for D-dimer [0.5 + (66-age) × 0.01 mg/L]. This method yielded a PLR of 2.9 at a very low NLR for the exclusion of VTE. We observed a significant cost reduction of 4.6% and 1.0% for PE and DVT, respectively. The utilization of an age-adjusted cut-off [patient's age × 0.01 mg/L] resulted in the highest cost savings, reaching 8.1% for PE and 3.4% for DVT. Using specified D-dimer cut-offs in the diagnosis of VTE could improve economics, considering the limited occurrence of confirmed cases among patients with suspected VTE.


Assuntos
Análise Custo-Benefício , Produtos de Degradação da Fibrina e do Fibrinogênio , Neoplasias , Tromboembolia Venosa , Humanos , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/economia , Tromboembolia Venosa/sangue , Pessoa de Meia-Idade , Neoplasias/sangue , Neoplasias/diagnóstico , Idoso , Estudos Retrospectivos , Masculino , Feminino , Alocação de Recursos , Redução de Custos
3.
Langenbecks Arch Surg ; 409(1): 111, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38587539

RESUMO

PURPOSE: The presence of an aberrant right hepatic artery (aRHA), arising from the superior mesenteric artery, is a common variant of the liver vascular anatomy. Considering that tumor spread occurs along vessels, the question arises, whether the presence of an aRHA influences the oncologic outcome after resection for cancer of the pancreatic head. METHODS: Patients with ductal adenocarcinoma of the pancreatic head, who underwent resection from 2011 to 2020 at the Frankfurt University Hospital, Germany, were analyzed retrospectively. Surgical records and computed tomography imaging were reviewed for the presence of aRHA. Overall and disease-free survival as well as hepatic recurrence were analyzed according to the presence of aRHA. RESULTS: aRHA was detected in 21 out of 145 patients (14.5%). The median overall survival was 26 months (95%CI 20.8-34.4), median disease-free survival was 12.1 months (95%CI 8.1-17.3). There was no significant difference in overall survival (26.1 versus 21.4 months, adjusted hazard ratio 1.31, 95%CI 0.7-2.46, p = 0.401) or disease-free survival (14.5 months versus 12 months, adjusted hazard ratio 0.98, 95%CI 0.57-1.71, p = 0.957) without and with aRHA. The hepatic recurrence rate was 24.4.% with conventional anatomy versus 30.8% with aRHA (adjusted odds ratio 1.36, 95%CI 0.3-5.38, p = 0.669). In the multivariable analysis, only lymphatic vessel invasion was an independent prognostic factor for hepatic recurrence. CONCLUSIONS: The presence of an aRHA does not seem to influence the long-term survival and hepatic recurrence after resection for ductal adenocarcinoma of the pancreatic head.


Assuntos
Adenocarcinoma , Artéria Hepática , Humanos , Artéria Hepática/cirurgia , Estudos Retrospectivos , Pâncreas , Pancreatectomia
4.
Emerg Radiol ; 31(3): 303-311, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38523224

RESUMO

PURPOSE: Recent advancements in medical imaging have transformed diagnostic assessments, offering exciting possibilities for extracting biomarker-based information. This study aims to investigate the capabilities of a machine learning classifier that incorporates dual-energy computed tomography (DECT) radiomics. The primary focus is on discerning and predicting outcomes related to pulmonary embolism (PE). METHODS: The study included 131 participants who underwent pulmonary artery DECT angiography between January 2015 and March 2022. Among them, 104 patients received the final diagnosis of PE and 27 patients served as a control group. A total of 107 radiomic features were extracted for every case based on DECT imaging. The dataset was divided into training and test sets for model development and validation. Stepwise feature reduction identified the most relevant features, which were used to train a gradient-boosted tree model. Receiver operating characteristics analysis and Cox regression tests assessed the association of texture features with overall survival. RESULTS: The trained machine learning classifier achieved a classification accuracy of 0.94 for identifying patients with acute PE with an area under the receiver operating characteristic curve of 0.91. Radiomics features could be valuable for predicting outcomes in patients with PE, demonstrating strong prognostic capabilities in survival prediction (c-index, 0.991 [0.979-1.00], p = 0.0001) with a median follow-up of 130 days (IQR, 38-720). Notably, the inclusion of clinical or DECT parameters did not enhance predictive performance. CONCLUSION: In conclusion, our study underscores the promising potential of leveraging radiomics on DECT imaging for the identification of patients with acute PE and predicting their outcomes. This approach has the potential to improve clinical decision-making and patient management, offering efficiencies in time and resources by utilizing existing DECT imaging without the need for an additional scoring system.


Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado de Máquina , Embolia Pulmonar , Humanos , Embolia Pulmonar/diagnóstico por imagem , Masculino , Feminino , Prognóstico , Pessoa de Meia-Idade , Angiografia por Tomografia Computadorizada/métodos , Idoso , Biomarcadores/sangue , Valor Preditivo dos Testes , Estudos Retrospectivos
5.
Chirurgie (Heidelb) ; 95(5): 347-352, 2024 May.
Artigo em Alemão | MEDLINE | ID: mdl-38158411

RESUMO

BACKGROUND: Mesenteric ischemia is a life-threatening condition with a complex etiology and diagnostics. OBJECTIVE: Etiology, incidence, symptoms, and diagnostics of acute and chronic mesenteric ischemia. MATERIAL AND METHODS: Literature search via PubMed with a focus on studies on the epidemiology and diagnostics of mesenteric ischemia and analysis of existing international guidelines. RESULTS: The incidence of acute mesenteric ischemia is given as 0.63-12.9 per 100,000 people per year. There are no sufficiently reliable figures for chronic mesenteric ischemia, but an incidence of up to 3 per 100,000 inhabitants per year is generally assumed. The three-phase computed tomography has the highest diagnostic specificity and sensitivity. CONCLUSION: In the presence of risk factors acute and chronic mesenteric ischemia should be considered as differential diagnoses in the presence of abdominal pain using three-phase computed tomography.


Assuntos
Isquemia Mesentérica , Humanos , Isquemia Mesentérica/diagnóstico por imagem , Isquemia Mesentérica/epidemiologia , Intestinos , Isquemia/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Fatores de Risco
6.
J Pers Med ; 14(4)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38673028

RESUMO

The aim of this study was to evaluate treatment of osteoid osteomas using bipolar radiofrequency ablation (RFA) and patients' quality of life before and after therapy. We retrospectively evaluated patients who underwent bipolar RFA of osteoid osteomas between 2001 and 2016. We assessed patients' symptoms before and after treatment (four weeks after treatment and long-term) using a questionnaire including severity and quality of pain on a 10-point scale (1 = no pain, 10 = severe pain), motion restrictions, pain-related sleep disorders, and necessary pain medication. In addition, we evaluated technical success, complications, hospitalization length, and patients' satisfaction with treatment. This study included 62 patients (43 [69.4%] males, 26.2 ± 13.2 years). Average nidus size was 5.7 ± 2.6 mm. The rate of technical success was 100%. All RFAs were performed without any complications. One patient showed a recurrence, resulting in a recurrence rate of 1.6%, which was successfully treated by another session of RFA. Average hospitalization length was 1.5 ± 0.5 days. A total of 36 patients (58.1%) participated in the questionnaire, reporting an average pain severity of 8.2 ± 1.6 before RFA compared to 3.4 ± 3.0 four weeks after and an average of 2.1 ± 2.3, 6.6 years after therapy, (both p < 0.001). After therapy, 31 (86.1%) patients had no pain. The majority of patients (n = 34, 94.4%) had reduced or absent motion restriction after therapy (p < 0.001). Patient satisfaction rate was 91.7%. In conclusion, bipolar RFA is a safe and effective treatment modality for osteoid osteomas and improves quality of life by reducing pain severity and motion restrictions.

7.
J Clin Med ; 13(4)2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38398377

RESUMO

BACKGROUND: Placenta accreta spectrum (PAS) disorders are a continuum of placental pathologies with increased risk for hemorrhage, blood transfusion and maternal morbidity. Uterine artery embolization (UAE) is a safe approach to the standardization of complex PAS cases. The aim of this study is to analyze anemia and transfusion rate, outcome and anesthesiological management of women who underwent caesarean delivery with subsequent UAE for the management of PAS. MATERIAL AND METHODS: This retrospective observational study included all pregnant women admitted to the University Hospital Frankfurt between January 2012 and September 2023, with a diagnosis of PAS who underwent a two-step surgical approach for delivery and placenta removal. Primary procedure included cesarean delivery with subsequent UAE, secondary procedure included placenta removal after a minim of five weeks via curettage or HE. Maternal characteristics, anesthesiological management, complications, anemia rate, blood loss and administration of blood products were analyzed. RESULTS: In total, 17 women with PAS were included in this study. Of these, 5.9% had placenta increta and 94.1% had placenta percreta. Median blood loss was 300 (200-600) mL during primary procedure and 3600 (450-5500) mL during secondary procedure. In total, 11.8% and 62.5% of women received red blood cell transfusion during the primary and secondary procedures, respectively. After primary procedure, postpartum anemia rate was 76.5%. The HE rate was 64.7%. Regional anesthesia was used in 88.2% during primary procedure. CONCLUSION: The embolization of the uterine artery for women diagnosed with PAS is safe. Anemia management and the implementation of blood conservation strategies are crucial in women undergoing UAE for the management of PAS.

8.
Diagnostics (Basel) ; 14(7)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38611654

RESUMO

OBJECTIVES: The aim of this study is to evaluate the diagnostic accuracy of dual-energy computed tomography (DECT)-based Rho/Z maps in differentiating between metastases and benign liver lesions in patients diagnosed with malignant melanoma compared to conventional CT value measurements. METHODS: This retrospective study included 73 patients (mean age, 70 ± 13 years; 43 m/30 w) suffering from malignant melanoma who had undergone third-generation DECT as part of tumor staging between December 2017 and December 2021. For this study, we measured Rho (electron density) and Z (effective atomic number) values as well as Hounsfield units (HUs) in hypodense liver lesions. Values were compared, and diagnostic accuracy for differentiation was computed using receiver operating characteristic (ROC) curve analyses. Additional performed MRI or biopsies served as a standard of reference. RESULTS: A total of 136 lesions (51 metastases, 71 cysts, and 14 hemangiomas) in contrast-enhanced DECT images were evaluated. The most notable discrepancy (p < 0.001) between measured values and the highest diagnostic accuracy for distinguishing melanoma metastases from benign cysts was observed for the Z (0.992; 95% CI, 0.956-1) parameters, followed by Rho (0.908; 95% CI, 0.842-0.953) and finally HU120kV (0.829; 95% CI, 0.751-0.891). Conversely, when discriminating between liver metastases and hemangiomas, the HU120kV parameters showed the most significant difference (p < 0.001) and yielded the highest values for diagnostic accuracy (0.859; 95% CI, 0.740-0.937), followed by the Z parameters (0.790; 95% CI, 0.681-0.876) and finally the Rho values (0.621; 95% CI, 0.501-0.730). CONCLUSIONS: Rho and Z measurements derived from DECT allow for improved differentiation of liver metastases and benign liver cysts in patients with malignant melanoma compared to conventional CT value measurements. In contrast, in differentiation between liver hemangiomas and metastases, Rho/Z maps show inferior diagnostic accuracy. Therefore, differentiation between these two lesions remains a challenge for CT imaging.

9.
Acad Radiol ; 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38461052

RESUMO

RATIONALE AND OBJECTIVES: Bone non-union is a serious complication of distal radius fractures (DRF) that can result in functional limitations and persistent pain. However, no accepted method has been established to identify patients at risk of developing bone non-union yet. This study aimed to compare various CT-derived metrics for bone mineral density (BMD) assessment to identify predictive values for the development of bone non-union. MATERIALS AND METHODS: CT images of 192 patients with DRFs who underwent unenhanced dual-energy CT (DECT) of the distal radius between 03/2016 and 12/2020 were retrospectively identified. Available follow-up imaging and medical health records were evaluated to determine the occurrence of bone non-union. DECT-based BMD, trabecular Hounsfield unit (HU), cortical HU and cortical thickness ratio were measured in normalized non-fractured segments of the distal radius. RESULTS: Patients who developed bone non-union were significantly older (median age 72 years vs. 54 years) and had a significantly lower DECT-based BMD (median 68.1 mg/cm3 vs. 94.6 mg/cm3, p < 0.001). Other metrics (cortical thickness ratio, cortical HU, trabecular HU) showed no significant differences. ROC and PR curve analyses confirmed the highest diagnostic accuracy for DECT-based BMD with an area under the curve (AUC) of 0.83 for the ROC curve and an AUC of 0.46 for the PR curve. In logistic regression models, DECT-based BMD was the sole metric significantly associated with bone non-union. CONCLUSION: DECT-derived metrics can accurately predict bone non-union in patients who sustained DRF. The diagnostic performance of DECT-based BMD is superior to that of HU-based metrics and cortical thickness ratio.

10.
Diagnostics (Basel) ; 14(5)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38472968

RESUMO

BACKGROUND: Despite a considerable amount of literature on dual-energy CT (DECT) iodine uptake of the head and neck, the physiologic iodine uptake of this region has not been defined yet. This study aims to establish reference values for the iodine uptake of healthy organs to facilitate clinical application. METHODS: Consecutive venous DECT scans of the head and neck were reviewed, and unremarkable exams were included (n = 617). A total of 35 region of interest measurements were performed in 16 anatomical regions. Iodine uptake was compared among different organs/tissues and subgroup analysis was performed (male (n = 403) vs. female (n = 214); young (n = 207) vs. middle-aged (n = 206) vs. old (n = 204); and normal weight (n = 314) vs. overweight (n = 196) vs. obese (n = 107)). RESULTS: Overall mean iodine uptake values ranged between 0.5 and 9.4 mg/mL. Women showed higher iodine concentrations in the cervical vessels and higher uptake for the parotid gland, masseter muscle, submandibular glands, sublingual glands, palatine tonsils, tongue body, thyroid gland, and the sternocleidomastoid muscle than men (p ≤ 0.04). With increasing age, intravascular iodine concentrations increased as well as iodine uptake for cerebellum and thyroid gland, while values for the tongue and palatine tonsils were lower compared to younger subjects (p ≤ 0.03). Iodine concentrations for parotid glands and sternocleidomastoid muscles decreased with a higher BMI (p ≤ 0.004), while normal-weighted patients showed higher iodine values inside the jugular veins, other cervical glands, and tonsils versus patients with a higher BMI (p ≤ 0.04). CONCLUSION: physiologic iodine uptake values of cervical organs and tissues show gender-, age-, and BMI-related differences, which should be considered in the clinical routine of head and neck DECT.

11.
Diagnostics (Basel) ; 14(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38611610

RESUMO

(1) Background: Low bone mineral density (BMD) is a significant risk factor for complicated surgery and leads to the increased use of bone substitutes in patients with distal radius fractures (DRFs). No accepted model has yet been established to predict the use of bone substitutes to facilitate preoperative planning. (2) Methods: Unenhanced dual-energy CT (DECT) images of DRFs were retrospectively acquired between March 2016 and September 2020 using the internal PACS system. Available follow-up imaging and medical health records were reviewed to determine the use of bone substitutes. DECT-based BMD, trabecular Hounsfield units (HU), cortical HU, and cortical thickness ratio were measured in non-fractured segments of the distal radius. Diagnostic accuracy parameters were calculated for all metrics using receiver-operating characteristic (ROC) curves and associations of all metrics with the use of bone substitutes were evaluated using logistic regression models. (3) The final study population comprised 262 patients (median age 55 years [IQR 43-67 years]; 159 females, 103 males). According to logistic regression analysis, DECT-based BMD was the only metric significantly associated with the use of bone substitutes (odds ratio 0.96, p = 0.003). However, no significant associations were found for cortical HU (p = 0.06), trabecular HU (p = 0.33), or cortical thickness ratio (p = 0.21). ROC-curve analysis revealed that a combined model of all four metrics had the highest diagnostic accuracy with an area under the curve (AUC) of 0.76. (4) Conclusions: DECT-based BMD measurements performed better than HU-based measurements and cortical thickness ratio. The diagnostic performance of all four metrics combined was superior to that of the individual parameters.

12.
Eur J Radiol ; 171: 111283, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38183896

RESUMO

BACKGROUND: Dual-energy CT (DECT)-derived bone mineral density (BMD) of the distal radius and other CT-derived metrics related to bone health have been suggested for opportunistic osteoporosis screening and risk evaluation for sustaining distal radius fractures (DRFs). METHODS: The distal radius of patients who underwent DECT between 01/2016 and 08/2021 was retrospectively analyzed. Cortical Hounsfield Unit (HU), trabecular HU, cortical thickness, and DECT-based BMD were acquired from a non-fractured, metaphyseal area in all examinations. Receiver-operating characteristic (ROC) analysis was conducted to determine the area under the curve (AUC) values for predicting DRFs based on DECT-derived BMD, HU values, and cortical thickness. Logistic regression models were then employed to assess the associations of these parameters with the occurrence of DRFs. RESULTS: In this study, 263 patients (median age: 52 years; interquartile range: 36-64; 132 women; 192 fractures) were included. ROC curve analysis revealed a higher area under the curve (AUC) value for DECT-derived BMD compared to cortical HU, trabecular HU, and cortical thickness (0.91 vs. 0.61, 0.64, and 0.69, respectively; p <.001). Logistic regression models confirmed the association between lower DECT-derived BMD and the occurrence of DRFs (Odds Ratio, 0.83; p <.001); however, no influence was observed for cortical HU, trabecular HU, or cortical thickness. CONCLUSIONS: DECT can be used to assess the BMD of the distal radius without dedicated equipment such as calibration phantoms to increase the detection rates of osteoporosis and stratify the individual risk to sustain DRFs. In contrast, assessing HU-based values and cortical thickness does not provide clinical benefit.


Assuntos
Fraturas Ósseas , Osteoporose , Humanos , Feminino , Pessoa de Meia-Idade , Rádio (Anatomia) , Absorciometria de Fóton , Estudos Retrospectivos , Osteoporose/diagnóstico por imagem , Densidade Óssea , Tomografia Computadorizada por Raios X , Medição de Risco
13.
Acad Radiol ; 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39117465

RESUMO

RATIONALE AND OBJECTIVES: This study aimed to compare the diagnostic value of dual-energy CT (DECT)-based volumetric material decomposition with that of Hounsfield units (HU)-based values and cortical thickness ratio for predicting the 2-year risk of osteoporosis-associated fractures. METHODS: The L1 vertebrae of 111 patients (55 men, 56 women; median age, 62 years) who underwent DECT between 01/2015 and 12/2018 were retrospectively analyzed. For phantomless bone mineral density (BMD) assessment, a specialized DECT postprocessing software employing material decomposition was utilized. The digital records of all patients were monitored for two years after the DECT scans to track the incidence of osteoporotic fractures. Diagnostic accuracy parameters were calculated for all metrics using receiver-operating characteristic (ROC) and precision-recall (PR) curves. Logistic regression models were used to determine associations of various predictive metrics with the occurrence of osteoporotic fractures. RESULTS: Patients who sustained one or more osteoporosis-associated fractures in a 2-year interval were significantly older (median age 74.5 years [IQR 57-83 years]) compared those without such fractures (median age 50.5 years [IQR 38.5-69.5 years]). According to logistic regression models, DECT-derived BMD was the sole predictive parameter significantly associated with osteoporotic fracture occurrence across all age groups. ROC and PR curve analyses confirmed the highest diagnostic accuracy for DECT-based BMD, with an area under the curve (AUC) of 0.95 [95% CI: 0.89-0.98] for the ROC curve and an AUC of 0.96 [95% CI: 0.85-0.99] for the PR curve. CONCLUSION: The diagnostic performance of DECT-based BMD in predicting the 2-year risk of osteoporotic fractures is greater than that of HU-based metrics and the cortical thickness ratio. DECT-based BMD values are highly valuable in identifying patients at risk for osteoporotic fractures.

14.
Acad Radiol ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38519304

RESUMO

RATIONALE AND OBJECTIVES: Lumbar disk degeneration is a common condition contributing significantly to back pain. The objective of the study was to evaluate the potential of dual-energy CT (DECT)-derived collagen maps for the assessment of lumbar disk degeneration. PATIENTS AND METHODS: We conducted a retrospective analysis of 127 patients who underwent dual-source DECT and MRI of the lumbar spine between 07/2019 and 10/2022. The level of lumbar disk degeneration was categorized by three radiologists as follows: no/mild (Pfirrmann 1&2), moderate (Pfirrmann 3&4), and severe (Pfirrmann 5). Recall (sensitivity) and accuracy of DECT collagen maps were calculated. Intraclass correlation coefficient (ICC) was used to evaluate inter-reader reliability. Subjective evaluations were performed using 5-point Likert scales for diagnostic confidence and image quality. RESULTS: We evaluated a total of 762 intervertebral disks from 127 patients (median age, 69.7 (range, 23.0-93.7), female, 56). MRI identified 230 non/mildly degenerated disks (30.2%), 484 moderately degenerated disks (63.5%), and 48 severely degenerated disks (6.3%). DECT collagen maps yielded an overall accuracy of 85.5% (1955/2286). Recall (sensitivity) was 79.3% (547/690) for the detection of no/mild lumbar disk degeneration, 88.7% (1288/1452) for the detection of moderate disk degeneration, and 83.3% (120/144) for the detection of severe disk degeneration (ICC=0.9). Subjective evaluations of DECT collagen maps showed high diagnostic confidence (median 4) and good image quality (median 4). CONCLUSION: The use of DECT collagen maps to distinguish different stages of lumbar disk degeneration may have clinical significance in the early diagnosis of disk-related pathologies in patients with contraindications for MRI or in cases of unavailability of MRI.

15.
Acad Radiol ; 31(6): 2610-2619, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38242733

RESUMO

BACKGROUND: The advent of advanced computed tomography (CT) technology and the field of radiomics has opened up new avenues in diagnostic assessments. Increasingly, there is substantial evidence advocating for the incorporation of quantitative imaging biomarkers in the clinical decision-making process. This study aimed to examine the correlation between D-dimer levels and thrombus size in acute pulmonary embolism (PE) combining dual-energy CT (DECT) and radiomics and to investigate the diagnostic utility of a machine learning classifier based on dual-energy computed tomography (DECT) radiomics for identifying patients with a complicated course, defined as at least hospitalization at IMC. METHODS: The study was conducted including 136 participants who underwent pulmonary artery CT angiography from January 2015 to March 2022. Based on DECT imaging, 107 radiomic features were extracted for each patient using standardized image processing. After dividing the dataset into training and test sets, stepwise feature reduction based on reproducibility, variable importance and correlation analyses were performed to select the most relevant features; these were used to train and validate the gradient-boosted tree models.Receiver operating characteristics (ROC) analysis was utilized to evaluate the association between volumetric, laboratory data and adverse outcomes. RESULTS: In the central PE group, we observed a significant correlation between thrombus volumetrics and D-dimer levels (p = 0.0037), as well as between thrombus volumetrics and hospitalization at the Intermediate Care Unit (IMC) (p = 0.0001). In contrast, no statistically significant differences were identified in thrombus sizes between patients who experienced complications and those who had a favorable course (p = 0.3162). The trained machine learning classifier achieved an accuracy of 61% and 55% in identifying patients with a complicated course, as indicated by an area under the ROC curve of 0.63 and 0.58. CONCLUSION: In conclusion, our findings indicate a positive correlation between D-dimer levels and central PE's pulmonary embolic burden. Thrombus volumetrics may serve as an indicator for complications and outcomes in acute PE patients. Thus, thrombus volumetrics, as opposed to D-dimers, could be an additional marker for evaluating embolic disease severity. Moreover, DECT-derived radiomic feature models show promise in identifying patients with a complicated course, such as hospitalization at IMC.


Assuntos
Angiografia por Tomografia Computadorizada , Produtos de Degradação da Fibrina e do Fibrinogênio , Hospitalização , Embolia Pulmonar , Humanos , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/sangue , Feminino , Masculino , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Pessoa de Meia-Idade , Angiografia por Tomografia Computadorizada/métodos , Trombose/diagnóstico por imagem , Trombose/sangue , Aprendizado de Máquina , Biomarcadores/sangue , Idoso , Doença Aguda , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto , Tomografia Computadorizada por Raios X , Radiômica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA