Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 50(2): 352-375, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36326868

RESUMO

PURPOSE: The purpose of this guideline is to provide comprehensive information on best practices for robust radiomics analyses for both hand-crafted and deep learning-based approaches. METHODS: In a cooperative effort between the EANM and SNMMI, we agreed upon current best practices and recommendations for relevant aspects of radiomics analyses, including study design, quality assurance, data collection, impact of acquisition and reconstruction, detection and segmentation, feature standardization and implementation, as well as appropriate modelling schemes, model evaluation, and interpretation. We also offer an outlook for future perspectives. CONCLUSION: Radiomics is a very quickly evolving field of research. The present guideline focused on established findings as well as recommendations based on the state of the art. Though this guideline recognizes both hand-crafted and deep learning-based radiomics approaches, it primarily focuses on the former as this field is more mature. This guideline will be updated once more studies and results have contributed to improved consensus regarding the application of deep learning methods for radiomics. Although methodological recommendations in the present document are valid for most medical image modalities, we focus here on nuclear medicine, and specific recommendations when necessary are made for PET/CT, PET/MR, and quantitative SPECT.


Assuntos
Medicina Nuclear , Humanos , Medicina Nuclear/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Ciência de Dados , Cintilografia , Física
2.
Phys Med ; 119: 103307, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38325221

RESUMO

PURPOSE: Radiotherapy outcome modelling often suffers from class imbalance in the modelled endpoints. One of the main options to address this issue is by introducing new synthetically generated datapoints, using generative models, such as Denoising Diffusion Probabilistic Models (DDPM). In this study, we implemented DDPM to improve performance of a tumor local control model, trained on imbalanced dataset, and compare this approach with other common techniques. METHODS: A dataset of 535 NSCLC patients treated with SBRT (50 Gy/5 fractions) was used to train a deep learning outcome model for tumor local control prediction. The dataset included complete treatment planning data (planning CT images, 3D planning dose distribution and patient demographics) with sparsely distributed endpoints (6-7 % experiencing local failure). Consequently, we trained a novel conditional 3D DDPM model to generate synthetic treatment planning data. Synthetically generated treatment planning datapoints were used to supplement the real training dataset and the improvement in the model's performance was studied. Obtained results were also compared to other common techniques for class imbalanced training, such as Oversampling, Undersampling, Augmentation, Class Weights, SMOTE and ADASYN. RESULTS: Synthetic DDPM-generated data were visually trustworthy, with Fréchet inception distance (FID) below 50. Extending the training dataset with the synthetic data improved the model's performance by more than 10%, while other techniques exhibited only about 4% improvement. CONCLUSIONS: DDPM introduces a novel approach to class-imbalanced outcome modelling problems. The model generates realistic synthetic radiotherapy planning data, with a strong potential to increase performance and robustness of outcome models.


Assuntos
Bisacodil/análogos & derivados , Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Difusão , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia
3.
Radiother Oncol ; 196: 110277, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38670264

RESUMO

Radiotherapy developed empirically through experience balancing tumour control and normal tissue toxicities. Early simple mathematical models formalized this practical knowledge and enabled effective cancer treatment to date. Remarkable advances in technology, computing, and experimental biology now create opportunities to incorporate this knowledge into enhanced computational models. The ESTRO DREAM (Dose Response, Experiment, Analysis, Modelling) workshop brought together experts across disciplines to pursue the vision of personalized radiotherapy for optimal outcomes through advanced modelling. The ultimate vision is leveraging quantitative models dynamically during therapy to ultimately achieve truly adaptive and biologically guided radiotherapy at the population as well as individual patient-based levels. This requires the generation of models that inform response-based adaptations, individually optimized delivery and enable biological monitoring to provide decision support to clinicians. The goal is expanding to models that can drive the realization of personalized therapy for optimal outcomes. This position paper provides their propositions that describe how innovations in biology, physics, mathematics, and data science including AI could inform models and improve predictions. It consolidates the DREAM team's consensus on scientific priorities and organizational requirements. Scientifically, it stresses the need for rigorous, multifaceted model development, comprehensive validation and clinical applicability and significance. Organizationally, it reinforces the prerequisites of interdisciplinary research and collaboration between physicians, medical physicists, radiobiologists, and computational scientists throughout model development. Solely by a shared understanding of clinical needs, biological mechanisms, and computational methods, more informed models can be created. Future research environment and support must facilitate this integrative method of operation across multiple disciplines.


Assuntos
Neoplasias , Radiobiologia , Humanos , Neoplasias/radioterapia , Medicina de Precisão/métodos
4.
Radiat Oncol ; 16(1): 237, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34911546

RESUMO

BACKGROUND: Magnetic Resonance Image guided Stereotactic body radiotherapy (MRgRT) is an emerging technology that is increasingly used in treatment of visceral cancers, such as pancreatic adenocarcinoma (PDAC). Given the variable response rates and short progression times of PDAC, there is an unmet clinical need for a method to assess early RT response that may allow better prescription personalization. We hypothesize that quantitative image feature analysis (radiomics) of the longitudinal MR scans acquired before and during MRgRT may be used to extract information related to early treatment response. METHODS: Histogram and texture radiomic features (n = 73) were extracted from the Gross Tumor Volume (GTV) in 0.35T MRgRT scans of 26 locally advanced and borderline resectable PDAC patients treated with 50 Gy RT in 5 fractions. Feature ratios between first (F1) and last (F5) fraction scan were correlated with progression free survival (PFS). Feature stability was assessed through region of interest (ROI) perturbation. RESULTS: Linear normalization of image intensity to median kidney value showed improved reproducibility of feature quantification. Histogram skewness change during treatment showed significant association with PFS (p = 0.005, HR = 2.75), offering a potential predictive biomarker of RT response. Stability analyses revealed a wide distribution of feature sensitivities to ROI delineation and was able to identify features that were robust to variability in contouring. CONCLUSIONS: This study presents a proof-of-concept for the use of quantitative image analysis in MRgRT for treatment response prediction and providing an analysis pipeline that can be utilized in future MRgRT radiomic studies.


Assuntos
Adenocarcinoma/radioterapia , Imageamento por Ressonância Magnética/métodos , Neoplasias Pancreáticas/radioterapia , Radioterapia Guiada por Imagem/métodos , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/mortalidade , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/mortalidade , Carga Tumoral
5.
Pattern Recognit ; 42(6): 1162-1171, 2009 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20161266

RESUMO

Accumulating evidence suggests that characteristics of pre-treatment FDG-PET could be used as prognostic factors to predict outcomes in different cancer sites. Current risk analyses are limited to visual assessment or direct uptake value measurements. We are investigating intensity-volume histogram metrics and shape and texture features extracted from PET images to predict patient's response to treatment. These approaches were demonstrated using datasets from cervix and head and neck cancers, where AUC of 0.76 and 1.0 were achieved, respectively. The preliminary results suggest that the proposed approaches could potentially provide better tools and discriminant power for utilizing functional imaging in clinical prognosis.

6.
Phys Med Biol ; 52(17): N375-85, 2007 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-17762073

RESUMO

Monte Carlo (MC) dose calculations can be accurate but are also computationally intensive. In contrast, convolution superposition (CS) offers faster and smoother results but by making approximations. We investigated MC denoising techniques, which use available convolution superposition results and new noise filtering methods to guide and accelerate MC calculations. Two main approaches were developed to combine CS information with MC denoising. In the first approach, the denoising result is iteratively updated by adding the denoised residual difference between the result and the MC image. Multi-scale methods were used (wavelets or contourlets) for denoising the residual. The iterations are initialized by the CS data. In the second approach, we used a frequency splitting technique by quadrature filtering to combine low frequency components derived from MC simulations with high frequency components derived from CS components. The rationale is to take the scattering tails as well as dose levels in the high-dose region from the MC calculations, which presumably more accurately incorporates scatter; high-frequency details are taken from CS calculations. 3D Butterworth filters were used to design the quadrature filters. The methods were demonstrated using anonymized clinical lung and head and neck cases. The MC dose distributions were calculated by the open-source dose planning method MC code with varying noise levels. Our results indicate that the frequency-splitting technique for incorporating CS-guided MC denoising is promising in terms of computational efficiency and noise reduction.


Assuntos
Artefatos , Modelos Biológicos , Método de Monte Carlo , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Algoritmos , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
7.
Phys Med Biol ; 51(22): 5719-35, 2006 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-17068361

RESUMO

Radiotherapy treatment outcome models are a complicated function of treatment, clinical and biological factors. Our objective is to provide clinicians and scientists with an accurate, flexible and user-friendly software tool to explore radiotherapy outcomes data and build statistical tumour control or normal tissue complications models. The software tool, called the dose response explorer system (DREES), is based on Matlab, and uses a named-field structure array data type. DREES/Matlab in combination with another open-source tool (CERR) provides an environment for analysing treatment outcomes. DREES provides many radiotherapy outcome modelling features, including (1) fitting of analytical normal tissue complication probability (NTCP) and tumour control probability (TCP) models, (2) combined modelling of multiple dose-volume variables (e.g., mean dose, max dose, etc) and clinical factors (age, gender, stage, etc) using multi-term regression modelling, (3) manual or automated selection of logistic or actuarial model variables using bootstrap statistical resampling, (4) estimation of uncertainty in model parameters, (5) performance assessment of univariate and multivariate analyses using Spearman's rank correlation and chi-square statistics, boxplots, nomograms, Kaplan-Meier survival plots, and receiver operating characteristics curves, and (6) graphical capabilities to visualize NTCP or TCP prediction versus selected variable models using various plots. DREES provides clinical researchers with a tool customized for radiotherapy outcome modelling. DREES is freely distributed. We expect to continue developing DREES based on user feedback.


Assuntos
Modelos Biológicos , Neoplasias/radioterapia , Avaliação de Resultados em Cuidados de Saúde/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos , Software , Interface Usuário-Computador , Simulação por Computador , Relação Dose-Resposta à Radiação , Humanos , Linguagens de Programação , Dosagem Radioterapêutica
8.
Phys Med Biol ; 50(5): 909-22, 2005 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-15798264

RESUMO

Recent studies have demonstrated that Monte Carlo (MC) denoising techniques can reduce MC radiotherapy dose computation time significantly by preferentially eliminating statistical fluctuations ('noise') through smoothing. In this study, we compare new and previously published approaches to MC denoising, including 3D wavelet threshold denoising with sub-band adaptive thresholding, content adaptive mean-median-hybrid (CAMH) filtering, locally adaptive Savitzky-Golay curve-fitting (LASG), anisotropic diffusion (AD) and an iterative reduction of noise (IRON) method formulated as an optimization problem. Several challenging phantom and computed-tomography-based MC dose distributions with varying levels of noise formed the test set. Denoising effectiveness was measured in three ways: by improvements in the mean-square-error (MSE) with respect to a reference (low noise) dose distribution; by the maximum difference from the reference distribution and by the 'Van Dyk' pass/fail criteria of either adequate agreement with the reference image in low-gradient regions (within 2% in our case) or, in high-gradient regions, a distance-to-agreement-within-2% of less than 2 mm. Results varied significantly based on the dose test case: greater reductions in MSE were observed for the relatively smoother phantom-based dose distribution (up to a factor of 16 for the LASG algorithm); smaller reductions were seen for an intensity modulated radiation therapy (IMRT) head and neck case (typically, factors of 2-4). Although several algorithms reduced statistical noise for all test geometries, the LASG method had the best MSE reduction for three of the four test geometries, and performed the best for the Van Dyk criteria. However, the wavelet thresholding method performed better for the head and neck IMRT geometry and also decreased the maximum error more effectively than LASG. In almost all cases, the evaluated methods provided acceleration of MC results towards statistically more accurate results.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias Pulmonares/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Algoritmos , Anisotropia , Bases de Dados como Assunto , Difusão , Elétrons , Humanos , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Processamento de Sinais Assistido por Computador , Tomografia Computadorizada por Raios X/métodos
9.
Phys Med Biol ; 60(14): 5471-96, 2015 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-26119045

RESUMO

This study aims at developing a joint FDG-PET and MRI texture-based model for the early evaluation of lung metastasis risk in soft-tissue sarcomas (STSs). We investigate if the creation of new composite textures from the combination of FDG-PET and MR imaging information could better identify aggressive tumours. Towards this goal, a cohort of 51 patients with histologically proven STSs of the extremities was retrospectively evaluated. All patients had pre-treatment FDG-PET and MRI scans comprised of T1-weighted and T2-weighted fat-suppression sequences (T2FS). Nine non-texture features (SUV metrics and shape features) and forty-one texture features were extracted from the tumour region of separate (FDG-PET, T1 and T2FS) and fused (FDG-PET/T1 and FDG-PET/T2FS) scans. Volume fusion of the FDG-PET and MRI scans was implemented using the wavelet transform. The influence of six different extraction parameters on the predictive value of textures was investigated. The incorporation of features into multivariable models was performed using logistic regression. The multivariable modeling strategy involved imbalance-adjusted bootstrap resampling in the following four steps leading to final prediction model construction: (1) feature set reduction; (2) feature selection; (3) prediction performance estimation; and (4) computation of model coefficients. Univariate analysis showed that the isotropic voxel size at which texture features were extracted had the most impact on predictive value. In multivariable analysis, texture features extracted from fused scans significantly outperformed those from separate scans in terms of lung metastases prediction estimates. The best performance was obtained using a combination of four texture features extracted from FDG-PET/T1 and FDG-PET/T2FS scans. This model reached an area under the receiver-operating characteristic curve of 0.984 ± 0.002, a sensitivity of 0.955 ± 0.006, and a specificity of 0.926 ± 0.004 in bootstrapping evaluations. Ultimately, lung metastasis risk assessment at diagnosis of STSs could improve patient outcomes by allowing better treatment adaptation.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Sarcoma/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Extremidades/diagnóstico por imagem , Extremidades/patologia , Feminino , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/secundário , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Sarcoma/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA