Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
BMC Infect Dis ; 21(1): 118, 2021 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-33499820

RESUMO

BACKGROUND: Early infant diagnosis of HIV infection is challenging in sub-Saharan Africa, particularly in rural areas, leading to delays in diagnosis and treatment. Use of a point-of-care test would overcome many challenges. This study evaluated the validity of a novel point-of-care p24 antigen detection test (LYNX) in rural and urban settings in southern Zambia. METHODS: Two studies were conducted: a cross-sectional study from 2014 to 2015 at Macha Hospital (LYNX Hospital study) and a longitudinal study from 2016 to 2018 at 12 health facilities in Southern Province, Zambia (NSEBA study). In both studies, children attending the facilities for early infant diagnosis were enrolled and a blood sample was collected for routine testing at the central lab and immediate on-site testing with the LYNX test. The performance of the LYNX test was measured in comparison to nucleic acid-based testing at the central lab. RESULTS: In the LYNX Hospital study, 210 tests were performed at a median age of 23.5 weeks (IQR: 8.9, 29.0). The sensitivity and specificity of the test were 70.0 and 100.0%, respectively. In the NSEBA study, 2608 tests were performed, including 1305 at birth and 1222 on children ≥4 weeks of age. For samples tested at birth, sensitivity was 13.6% (95% CI: 2.9, 34.9) and specificity was 99.6% (95% CI: 99.1, 99.9). While specificity was high for all ages, sensitivity increased with age and was higher for participants tested at ≥4 weeks of age (80.6%; 95% CI: 67.4, 93.7). Children with positive nucleic acid tests were more likely to be negative by the LYNX test if their mother received antiretroviral therapy during pregnancy (60.7% vs. 24.2%; p = 004). CONCLUSIONS: Considering the high specificity and moderate sensitivity that increased with age, the LYNX test could be of value for early infant diagnosis for infants ≥4 weeks of age, particularly in rural areas where centralized testing leads to long delays. Point-of-care tests with moderate sensitivity and high specificity that are affordable, easy-to-use, and easily implemented and maintained should be developed to expand access to testing and deliver same-day results to infants in areas where it is not feasible to implement nucleic acid-based point-of-care assays.


Assuntos
Proteína do Núcleo p24 do HIV/análise , Infecções por HIV/diagnóstico , Testes Imediatos , Fármacos Anti-HIV/uso terapêutico , Estudos Transversais , Testes Diagnósticos de Rotina , Diagnóstico Precoce , Estudos de Viabilidade , Feminino , Proteína do Núcleo p24 do HIV/sangue , Infecções por HIV/congênito , Infecções por HIV/epidemiologia , Infecções por HIV/transmissão , Humanos , Testes Imunológicos , Ciência da Implementação , Lactente , Recém-Nascido , Transmissão Vertical de Doenças Infecciosas , Estudos Longitudinais , Masculino , Triagem Neonatal/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Gravidez , Complicações Infecciosas na Gravidez/tratamento farmacológico , Complicações Infecciosas na Gravidez/epidemiologia , População Rural , Sensibilidade e Especificidade , Zâmbia/epidemiologia
2.
Proc Natl Acad Sci U S A ; 106(44): 18437-42, 2009 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-19841273

RESUMO

We report the development of a previously undescribed gold nanoparticle bio-barcode assay probe for the detection of prostate specific antigen (PSA) at 330 fg/mL, automation of the assay, and the results of a clinical pilot study designed to assess the ability of the assay to detect PSA in the serum of 18 men who have undergone radical prostatectomy for prostate cancer. Due to a lack of sensitivity, available PSA immunoassays are often not capable of detecting PSA in the serum of men after radical prostatectomy. This new bio-barcode PSA assay is approximately 300 times more sensitive than commercial immunoassays. Significantly, with the barcode assay, every patient in this cohort had a measurable serum PSA level after radical prostatectomy. Patients were separated into categories based on PSA levels as a function of time. One group of patients showed low levels of PSA with no significant increase with time and did not recur. Others showed, at some point postprostatectomy, rising PSA levels. The majority recurred. Therefore, this new ultrasensitive assay points to significant possible outcomes: (i) The ability to tell patients, who have undetectable PSA levels with conventional assays, but detectable and nonrising levels with the barcode assay, that their cancer will not recur. (ii) The ability to assign recurrence earlier because of the ability to measure increasing levels of PSA before conventional tools can make such assignments. (iii) The ability to use PSA levels that are not detectable with conventional assays to follow the response of patients to adjuvant or salvage therapies.


Assuntos
Bioensaio/métodos , Nanopartículas Metálicas/química , Antígeno Prostático Específico/sangue , Prostatectomia , Calibragem , Humanos , Masculino , Sondas Moleculares/metabolismo , Cuidados Pós-Operatórios , Neoplasias da Próstata/cirurgia
3.
BMC Biotechnol ; 3: 6, 2003 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-12801425

RESUMO

BACKGROUND: DNA microarrays are now routinely used to monitor the transcript levels of thousands of genes simultaneously. However, the array fabrication method, hybridization conditions, and oligodeoxyribonucleotide probe length can impact the performance of a DNA microarray platform. RESULTS: We demonstrate solution-phase hybridization behavior of probe:target interactions by showing a strong correlation between the effect of mismatches in probes attached to a three dimensional matrix of a microarray and solution-based, thermodynamic duplex melting studies. The effects of mismatches in the probes attached to the microarray also demonstrate that most, if not all, of the oligodeoxyribonucleotide is available for hybridization. Kinetic parameters were also investigated. As anticipated, hybridization signals increased in a transcript concentration-dependent manner, and mismatch specificity increased with hybridization time. Unexpectedly, hybridization time increased the accuracy of fold changes by relieving the compression observed in expression ratios, and this effect may be more dramatic for larger fold changes. CONCLUSIONS: Taken together, these studies demonstrate that a three-dimensional surface may enable use of shorter oligodeoxyribonucleotide probes and that hybridization time may be critical in improving the accuracy of microarray data.


Assuntos
Perfilação da Expressão Gênica/métodos , Hibridização de Ácido Nucleico/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Sondas de Oligonucleotídeos/química , Sensibilidade e Especificidade , DNA Complementar/análise , Hibridização Genética , Fatores de Tempo
5.
J Virol Methods ; 173(1): 37-42, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21219933

RESUMO

A major requirement for the development of point-of-care tests for the detection of disease analytes is the need to separate plasma from whole blood in an efficient and rapid manner. Furthermore, the separated plasma must be able to elute efficiently the analyte of interest and serve effectively as a physical matrix to deliver the equivalent of neat plasma for downstream diagnostic analysis. Additionally, many applications require the use of heat shock to liberate immunocomplexed antigen found in the collected plasma. A membrane-based filter method is reported for rapid and efficient collection of plasma from a whole blood sample that is compatible with heat shock. Using pediatric human immunodeficiency virus as an example, this device elutes 100% of the input p24 core antigen post-collection and enables heat shock of plasma samples identical to neat plasma treatment.


Assuntos
Filtração/métodos , Infecções por HIV/diagnóstico , Plasma/virologia , Sistemas Automatizados de Assistência Junto ao Leito , Manejo de Espécimes/métodos , Virologia/métodos , Humanos
6.
J Acquir Immune Defic Syndr ; 55(4): 413-9, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20811289

RESUMO

Currently, the majority of HIV-infected infants are found within limited-resource settings, where inadequate screening for HIV due to the lack of access to simple and affordable point-of-care tests impedes implementation of antiretroviral therapy. Here we report development of a low-cost dipstick p24 antigen assay using a visual readout format that can facilitate the diagnosis of HIV for infants in resource-poor conditions. A heat shock methodology was developed to optimize disruption of immune complexes present in the plasma of infected infants. The analytical sensitivity of the assay using recombinant p24 antigen is 50 pg/mL (2 pM) with whole virus detection as low as 42.5k RNA copies per milliliter plasma. In a blinded study comprising 51 archived infant samples from the Women and Infants Transmission Study, our assay demonstrated an overall sensitivity and specificity of 90% and 100%, respectively. In field evaluations of 389 fresh samples from South African infants, a sensitivity of 95% and specificity of 99% was achieved. The assay is simple to perform, requires minimal plasma volume (25 µL), and yields a result in less than 40 minutes making it ideal for implementation in resource-limited settings.


Assuntos
Proteína do Núcleo p24 do HIV/sangue , Infecções por HIV/diagnóstico , HIV/isolamento & purificação , África Subsaariana , Anticorpos Monoclonais/imunologia , Feminino , Anticorpos Anti-HIV/imunologia , Proteína do Núcleo p24 do HIV/imunologia , Humanos , Imunoensaio , Lactente , Recém-Nascido , Fitas Reagentes , Proteínas Recombinantes/sangue , Proteínas Recombinantes/imunologia , Sensibilidade e Especificidade , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA