Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cardiol Young ; 27(6): 1180-1185, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28088920

RESUMO

BACKGROUND: Identification of patients with latent rheumatic heart disease by echocardiography presents a unique opportunity to prevent disease progression. Myocardial strain is a more sensitive indicator of cardiac performance than traditional measures of systolic function. OBJECTIVE: The objective of this study was to test the hypothesis that abnormalities in myocardial strain may be present in children with latent rheumatic heart disease. METHODS: Standard echocardiography images with electrocardiogram gating were obtained from Ugandan children found to have latent rheumatic heart disease as well as control subjects. Traditional echocardiography measures of systolic function were obtained, and offline global longitudinal strain analysis was performed. Comparison between groups was performed using strain as a continuous (Mann-Whitney U-test) and categorical (cut-off 5th percentile for age) variable. RESULTS: Our study included 14 subjects with definite rheumatic heart disease, 13 with borderline rheumatic heart disease, and 112 control subjects. None of the subjects had abnormal left ventricular size or ejection fraction. Global longitudinal strain was lower than the 5th percentile in 44% of the subjects with any rheumatic heart disease (p=0.002 versus controls) and 57% of the subjects with definite rheumatic heart disease (p=0.03). The mean absolute strain values were significantly lower when comparing subjects with any rheumatic heart disease with controls (20.4±3.95 versus 22.4±4.35, p=0.025) and subjects with definite rheumatic heart disease with controls (19.9±4.25 versus 22.4±4.35, p=0.033). CONCLUSION: Global longitudinal strain is decreased in subjects with rheumatic heart disease in the absence of abnormal systolic function. Larger studies with longer-term follow-up are required to determine whether there is a role for strain to help better understand the pathophysiology of latent rheumatic heart disease.


Assuntos
Ecocardiografia/métodos , Ventrículos do Coração/fisiopatologia , Cardiopatia Reumática/diagnóstico , Função Ventricular Esquerda/fisiologia , Adolescente , Estudos de Casos e Controles , Criança , Progressão da Doença , Eletrocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos , Sístole
2.
Circulation ; 125(21): 2630-8, 2012 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-22523314

RESUMO

BACKGROUND: The Pediatric Heart Network trial comparing outcomes in 549 infants with single right ventricle undergoing a Norwood procedure randomized to modified Blalock-Taussig shunt or right ventricle-pulmonary artery shunt (RVPAS) found better 1-year transplant-free survival in those who received RVPAS. We sought to compare the impact of shunt type on echocardiographic indices of cardiac size and function up to 14 months of age. METHODS AND RESULTS: A core laboratory measured indices of cardiac size and function from protocol exams: early after Norwood procedure (age 22.5 ± 13.4 days), before stage II procedure (age 4.8 ± 1.8 months), and at 14 months (age 14.3 ± 1.2 months). Mean right ventricular ejection fraction was <50% at all intervals for both groups and was higher in the RVPAS group after Norwood procedure (49 ± 7% versus 44 ± 8%; P<0.001) but was similar by 14 months. Tricuspid and neoaortic regurgitation, diastolic function, and pulmonary artery and arch dimensions were similar in the 2 groups at all intervals. Neoaortic annulus area (4.2 ± 1.2 versus 4.9 ± 1.2 cm(2)/m(2)), systolic ejection times (214.0 ± 29.4 versus 231.3 ± 28.6 ms), neoaortic flow (6.2 ± 2.4 versus 9.4 ± 3.4 L/min per square meter), and peak arch velocity (1.9 ± 0.7 versus 2.2 ± 0.7 m/s) were lower at both interstage examinations in the RVPAS compared with the modified Blalock-Taussig shunt group (P<0.001 for all), but all were similar at 14 months. CONCLUSIONS: Indices of cardiac size and function after the Norwood procedure are similar for modified Blalock-Taussig shunt and RVPAS by 14 months of age. Interstage differences between shunt types can likely be explained by the physiology created when the shunts are in place rather than by intrinsic differences in cardiac function. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00115934.


Assuntos
Ecocardiografia , Ventrículos do Coração/cirurgia , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Miocárdio/patologia , Procedimentos de Norwood/métodos , Artéria Pulmonar/cirurgia , Anastomose Cirúrgica/métodos , Procedimento de Blalock-Taussig/métodos , Diástole/fisiologia , Ventrículos do Coração/fisiopatologia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Lactente , Recém-Nascido , Tamanho do Órgão , Volume Sistólico/fisiologia , Sístole/fisiologia , Resultado do Tratamento
3.
Pediatr Cardiol ; 33(1): 83-9, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21910018

RESUMO

The authors have demonstrated that histotripsy (pulsed cavitational ultrasound) can create atrial septal defects and ventricular septal defects (VSDs) in an open-chest canine model transcutaneously through the intact chest of neonatal pigs. To assess the potential untoward effects of these applications, the clinical, systemic, and pathologic effects of histotripsy-induced intracardiac communications were analyzed. Six neonatal pigs received noninvasive ultrasound therapy to their ventricular septa, then were allowed to survive 1 month for evaluation of intermediate-term effects. The results were compared with those of six previous animals killed immediately and three others killed 2-3 days after the procedure. Brain magnetic resonance imaging (MRI) and an assessment of cardiac function were performed with long-term survivors, and pathologic specimens were obtained when the animals were killed. In all 15 animals, VSDs 2-6.5 mm wide were successfully created. No fatalities occurred, and all the animals thrived, achieving normal weight gain by the time they were killed. Brain MRI and lung pathology exhibited no evidence of thromboembolic events. No damage to intervening tissue was observed. Pathologic analysis showed demarcated damage to the ventricular septa. Flanking injury and hemorrhage observed acutely were resolved by 1 month, with tissue remodeling present. Transcutaneous histotripsy is a safe and effective technique for creating intracardiac communications noninvasively without intermediate-term untoward effects. With further refinement and development, histotripsy has the potential to become an effective tool for palliation of congenital heart disease.


Assuntos
Cardiopatias Congênitas/terapia , Comunicação Interatrial/etiologia , Comunicação Interventricular/etiologia , Terapia por Ultrassom , Animais , Modelos Animais de Doenças , Suínos , Terapia por Ultrassom/efeitos adversos
4.
Catheter Cardiovasc Interv ; 77(4): 580-8, 2011 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-20853366

RESUMO

OBJECTIVE: To determine if pulsed cavitational ultrasound therapy (histotripsy) can accurately and safely generate ventricular septal defects (VSDs) through the intact chest of a neonatal animal, with the eventual goal of developing a noninvasive technique of creating intra-cardiac communications in patients with congenital heart disease. BACKGROUND: Histotripsy is an innovative ultrasonic technique that generates demarcated, mechanical tissue fractionation utilizing high intensity ultrasound pulses. Previous work has shown that histotripsy can create atrial septal defects in a beating heart in an open-chest canine model. METHODS: Nine neonatal pigs were treated with transcutaneous histotripsy targeting the ventricular septum. Ultrasound pulses of 5-µsec duration at a peak negative pressure of 13 MPa and a pulse repetition frequency of 1 kHz were generated by a 1 MHz focused transducer. The procedure was guided by real-time ultrasound imaging. RESULTS: VSDs were created in all pigs with diameters ranging from 2 to 6.5 mm. Six pigs were euthanized within 2 hrs of treatment, while three were recovered and maintained for 2-3 days to evaluate lesion maturation and clinical side effects. There were only transient clinical effects and pathology revealed mild collateral damage around the VSD with no significant damage to other cardiac or extra-cardiac structures. CONCLUSIONS: Histotripsy can accurately and safely generate VSDs through the intact chest in a neonatal animal model. These results suggest that with further advances, histotripsy can be a useful, noninvasive technique to create intracardiac communications, which currently require invasive catheter-based or surgical procedures, to clinically stabilize newborn infants with complex congenital heart disease.


Assuntos
Modelos Animais de Doenças , Comunicação Interventricular/etiologia , Terapia por Ultrassom/efeitos adversos , Animais , Animais Recém-Nascidos , Ecocardiografia Doppler em Cores , Desenho de Equipamento , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/patologia , Microbolhas , Suínos , Fatores de Tempo , Transdutores , Terapia por Ultrassom/instrumentação , Ultrassonografia de Intervenção
5.
Heart ; 102(1): 35-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26438784

RESUMO

OBJECTIVES: Handheld echocardiography (HAND) has good sensitivity and specificity for rheumatic heart disease (RHD) when performed by cardiologists. However, physician shortages in RHD-endemic areas demand less-skilled users to make RHD screening practical. We examine nurse performance and interpretation of HAND using a simplified approach for RHD screening. METHODS: Two nurses received training on HAND and a simplified screening approach. Consented students at two schools in Uganda were eligible for participation. A simplified approach (HAND performed and interpreted by a non-expert) was compared with the reference standard (standard portable echocardiography, performed and interpreted by experts according to the 2012 World Heart Federation guidelines). Reasons for false-positive and false-negative HAND studies were identified. RESULTS: A total of 1002 children were consented, with 956 (11.1 years, 41.8% male) having complete data for review. Diagnoses included: 913 (95.5%) children were classified normal, 32 (3.3%) borderline RHD and 11 (1.2%) definite RHD. The simplified approach had a sensitivity of 74.4% (58.8% to 86.5%) and a specificity of 78.8% (76.0% to 81.4%) for any RHD (borderline and definite). Sensitivity improved to 90.9% (58.7% to 98.5%) for definite RHD. Identification and measurement of erroneous colour jets was the most common reason for false-positive studies (n=164/194), while missed mitral regurgitation and shorter regurgitant jet lengths with HAND were the most common reasons for false-negative studies (n=10/11). CONCLUSIONS: Non-expert-led HAND screening programmes offer a potential solution to financial and workforce barriers that limit widespread RHD screening. Nurses trained on HAND using a simplified approach had reasonable sensitivity and specificity for RHD screening. Information on reasons for false-negative and false-positive screening studies should be used to inform future training protocols, which could lead to improved screening performance.


Assuntos
Ecocardiografia Doppler em Cores/enfermagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/enfermagem , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/enfermagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Criança , Competência Clínica , Países em Desenvolvimento , Ecocardiografia Doppler em Cores/instrumentação , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Cardiopatia Reumática/fisiopatologia , Análise e Desempenho de Tarefas , Uganda
6.
Eur Heart J Cardiovasc Imaging ; 16(5): 475-82, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25564396

RESUMO

AIMS: The World Heart Federation (WHF) guidelines for rheumatic heart disease (RHD) are designed for a standard portable echocardiography (STAND) machine. A recent study in a tertiary care centre demonstrated that they also had good sensitivity and specificity when modified for use with handheld echocardiography (HAND). Our study aimed to evaluate the performance of HAND for early RHD diagnosis in the setting of a large-scale field screening. METHODS AND RESULTS: STAND was performed in 4773 children in Gulu, Uganda, with 10% randomly assigned to also undergo HAND. Additionally, any child with mitral or aortic regurgitation also underwent HAND. Studies were performed by experienced echocardiographers and blindly reviewed by cardiologists using 2012 WHF criteria, which were modified slightly for HAND--due to the lack of spectral Doppler capability. Paired echocardiograms were performed in 1420 children (mean age 10.8 and 53% female), resulting in 1234 children who were normal, 133 who met criteria for borderline RHD, 47 who met criteria for definite RHD, and 6 who had other diagnoses. HAND had good sensitivity and specificity for RHD detection (78.9 and 87.2%, respectively), but was most sensitive for definite RHD (97.9%). Inter- and intra-reviewer agreement ranged between 66-83 and 71.4-94.1%, respectively. CONCLUSIONS: HAND has good sensitivity and specificity for diagnosis of early RHD, performing best for definite RHD. Protocols for RHD detection utilizing HAND will need to include confirmation by STAND to avoid over-diagnosis. Strategies that evaluate simplified screening protocols and training of non-physicians hold promise for more wide spread deployment of HAND-based protocols.


Assuntos
Ecocardiografia/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Cardiopatia Reumática/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia , Criança , Diagnóstico Precoce , Feminino , Humanos , Masculino , Programas de Rastreamento/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/epidemiologia , Estudos Prospectivos , Cardiopatia Reumática/epidemiologia , Sensibilidade e Especificidade , Uganda/epidemiologia
8.
Am J Cardiol ; 106(7): 1054-8, 2010 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-20854974

RESUMO

Patent foramen ovale (PFO) is associated with cryptogenic stroke, migraine headache, decompression sickness, and platypnea-orthodeoxia syndrome. Patients undergoing transesophageal echocardiography are often hypovolemic from preprocedural fasting and might not demonstrate right to left shunting owing to insufficient right atrial pressure generation, despite provocative maneuvers. We hypothesized that volume replenishment with saline loading could potentially unmask a PFO by favorably modulating the interatrial pressure gradient. Our study sought to examine the role of pre- or intraprocedural intravenous fluid replenishment on PFO detection during transesophageal echocardiography. A total of 103 patients were enrolled. An initial series of bubble injections was performed unprovoked and then with provocative maneuvers such as the Valsalva maneuver and coughing. The patients were then given a rapid 500 ml saline bolus, and the same sequence of bubble injections was repeated. The presence, type, and magnitude of the right to left shunts were noted before and after the saline bolus. The detection rate of PFO increased from 10.6% to 26.2% after saline loading without any provocative maneuvers. When combined with provocative maneuvers (Valsalva or cough), saline loading improved the detection rate from 17.4% to 32.0%. Overall, from amongst the 103 enrolled patients, saline bolusing resulted in a de novo diagnosis of PFO in 15 patients, atrial septal aneurysm in 15, PFO coexisting with an atrial septal aneurysm in 10, and pulmonary arteriovenous fistula in 5 patients. In conclusion, saline infusion in appropriately selected patients during transesophageal echocardiography significantly enhances the detection of PFOs and pulmonary arteriovenous fistulas.


Assuntos
Ecocardiografia Transesofagiana , Hidratação , Forame Oval Patente/diagnóstico por imagem , Idoso , Feminino , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade
9.
J Am Coll Cardiol ; 47(11): 2283-8, 2006 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-16750697

RESUMO

OBJECTIVES: The aim of this work was to evaluate myocardial contractility using the end-systolic wall stress (ESSm)-velocity of circumferential fiber shortening (VCFc) relationship in sickle cell anemia (SCA) patients compared with a similar age group of African-American (AA) control patients. BACKGROUND: Abnormalities of myocardial function have been documented in SCA patients using load-dependent echocardiographic indexes. Whether the systolic dysfunction results from impaired myocardial contractility or altered loading conditions is unknown because controlled studies using a load-independent measure of contractility have not been performed. METHODS: Fifty healthy AA patients and 57 SCA patients age 3 months to 18 years were studied. Simultaneous indirect arterial pulse tracing, phonocardiogram, electrocardiogram, and M-mode tracing of the left ventricular (LV) short-axis were recorded. The LV dimensions, corrected ejection time (ETc), percent fractional shortening (%FS), VCFc, and ESSm were determined. The ESSm-VCFc relationship was calculated and compared between groups. Duration and severity of anemia and effects of exchange transfusion on the ESSm-VCFc relationship were determined. RESULTS: The SCA patients had increased LV dimensions in systole and diastole, and increased indexed LV mass. Load-dependent measurements of LV function (ETc, %FS, and VCFc) were lower in SCA patients, and afterload, as measured by ESSm, was increased. The ESSm-VCFc relationship demonstrated reduced contractility in SCA patients compared with control subjects. Degree and duration of anemia along with exchange transfusions did not impact contractility. CONCLUSIONS: Sickle cell anemia patients have significant LV dilatation and increased LV mass due to abnormal loading conditions. Contractility, measured by the ESSm-VCFc index, is lower in SCA patients and was not negatively impacted by severity or duration of anemia, or exchange transfusions. The underlying mechanism explaining these findings requires further investigation.


Assuntos
Anemia Falciforme/fisiopatologia , Contração Miocárdica , Miofibrilas , Sístole , Função Ventricular Esquerda , Adolescente , Negro ou Afro-Americano , Anemia Falciforme/sangue , Anemia Falciforme/diagnóstico por imagem , Estudos de Casos e Controles , Criança , Pré-Escolar , Ecocardiografia , Feminino , Humanos , Lactente , Masculino , Estudos Prospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Função Ventricular
10.
J Am Soc Echocardiogr ; 18(7): 743-8, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16003272

RESUMO

BACKGROUND: The end-systolic wall stress (ESS)-heart rate-corrected velocity of circumferential fiber shortening (VCFc) relationship provides a load-independent assessment of systolic function. Previously published indices may not be appropriate for studies where ethnicity may introduce bias. OBJECTIVE: We sought to investigate potential differences in the ESS-VCFc relationship between the African American (AA) and Caucasian population. METHODS: In all, 50 AAs and 72 Caucasians, age 3 months to 17 years, were studied. Arterial pulse tracing, phonocardiogram, electrocardiogram, and M-mode of the left ventricle were recorded. Left ventricular dimensions, functional indices, ESS, and ESS-VCFc relationships were compared between groups. RESULTS: AAs had decreased indexed left ventricular end-systolic dimensions and increased septal and posterior wall thickness. AAs had increased percent fractional shortening, VCFc, and decreased ESS. Meridional ESS-VCFc relationships for the groups were similar. CONCLUSIONS: Young AAs have slightly thicker ventricles with increased VCFc, lower systolic volumes, and diminished ESS compared with control subjects. Despite differences, the meridional ESS-VCFc relationships were similar and correlated closely to previously reported normal indices.


Assuntos
Negro ou Afro-Americano/estatística & dados numéricos , Ventrículos do Coração/diagnóstico por imagem , Contração Miocárdica/fisiologia , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , População Branca/estatística & dados numéricos , Adolescente , Distribuição por Idade , Criança , Pré-Escolar , Elasticidade , Feminino , Frequência Cardíaca/fisiologia , Humanos , Lactente , Masculino , Distribuição por Sexo , Estresse Mecânico , Ultrassonografia , Estados Unidos/etnologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA