Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
N Engl J Med ; 390(17): 1572-1583, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38588025

RESUMO

BACKGROUND: Among low-risk patients with severe, symptomatic aortic stenosis who are eligible for both transcatheter aortic-valve implantation (TAVI) and surgical aortic-valve replacement (SAVR), data are lacking on the appropriate treatment strategy in routine clinical practice. METHODS: In this randomized noninferiority trial conducted at 38 sites in Germany, we assigned patients with severe aortic stenosis who were at low or intermediate surgical risk to undergo either TAVI or SAVR. Percutaneous- and surgical-valve prostheses were selected according to operator discretion. The primary outcome was a composite of death from any cause or fatal or nonfatal stroke at 1 year. RESULTS: A total of 1414 patients underwent randomization (701 to the TAVI group and 713 to the SAVR group). The mean (±SD) age of the patients was 74±4 years; 57% were men, and the median Society of Thoracic Surgeons risk score was 1.8% (low surgical risk). The Kaplan-Meier estimate of the primary outcome at 1 year was 5.4% in the TAVI group and 10.0% in the SAVR group (hazard ratio for death or stroke, 0.53; 95% confidence interval [CI], 0.35 to 0.79; P<0.001 for noninferiority). The incidence of death from any cause was 2.6% in the TAVI group and 6.2% in the SAVR group (hazard ratio, 0.43; 95% CI, 0.24 to 0.73); the incidence of stroke was 2.9% and 4.7%, respectively (hazard ratio, 0.61; 95% CI, 0.35 to 1.06). Procedural complications occurred in 1.5% and 1.0% of patients in the TAVI and SAVR groups, respectively. CONCLUSIONS: Among patients with severe aortic stenosis at low or intermediate surgical risk, TAVI was noninferior to SAVR with respect to death from any cause or stroke at 1 year. (Funded by the German Center for Cardiovascular Research and the German Heart Foundation; DEDICATE-DZHK6 ClinicalTrials.gov number, NCT03112980.).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Estimativa de Kaplan-Meier , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Fatores de Risco , Alemanha
2.
Transpl Int ; 37: 12445, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38962472

RESUMO

While allograft rejection (AR) continues to threaten the success of cardiothoracic transplantation, lack of accurate and repeatable surveillance tools to diagnose AR is a major unmet need in the clinical management of cardiothoracic transplant recipients. Endomyocardial biopsy (EMB) and transbronchial biopsy (TBBx) have been the cornerstone of rejection monitoring since the field's incipience, but both suffer from significant limitations, including poor concordance of biopsy interpretation among pathologists. In recent years, novel molecular tools for AR monitoring have emerged and their performance characteristics have been evaluated in multiple studies. An international working group convened by ESOT has reviewed the existing literature and provides a series of recommendations to guide the use of these biomarkers in clinical practice. While acknowledging some caveats, the group recognized that Gene-expression profiling and donor-derived cell-free DNA (dd-cfDNA) may be used to rule out rejection in heart transplant recipients, but they are not recommended for cardiac allograft vasculopathy screening. Other traditional biomarkers (NT-proBNP, BNP or troponin) do not have sufficient evidence to support their use to diagnose AR. Regarding lung transplant, dd-cfDNA could be used to rule out clinical rejection and infection, but its use to monitor treatment response is not recommended.


Assuntos
Biomarcadores , Rejeição de Enxerto , Transplante de Coração , Transplante de Pulmão , Humanos , Biomarcadores/sangue , Biópsia , Ácidos Nucleicos Livres/sangue , Consenso , Europa (Continente) , Perfilação da Expressão Gênica , Rejeição de Enxerto/diagnóstico , Transplante de Pulmão/efeitos adversos , Sociedades Médicas
3.
Artigo em Inglês | MEDLINE | ID: mdl-38889748

RESUMO

OBJECTIVES: Very precise positioning of the transcatheter heart valve (THV) inside the degenerated SAV is a crucial factor for valve-in-valve (ViV) procedure to achieve optimal hemodynamic results. Therefore, our study aimed to investigate the impact of implantation depth on functional results after ViV procedures in a standardized in vitro setting. METHODS: THV (SAPIEN 3 Ultra 23-mm size) and three SAV models (Magna Ease, Trifecta, and Hancock II-all 21-mm size) were tested at different circulatory conditions in five different positions of the THV (2-6 mm) inside the SAV. Mean pressure gradient (MPG), effective orifice area (EOA), geometric orifice area (GOAmax), and pinwheeling index (PWImean) were analyzed. RESULTS: EOA and MPG of the THV did not differ significantly regarding the position inside the Magna Ease and the Hancock II (p > 0.05). However, EOA differed significantly, depending on the position of the THV inside Trifecta (2 vs. 5 mm; p = 0.021 and 2 vs. 6 mm; p < 0.001). The THV presented the highest EOA (2.047 cm2) and the lowest MPG (5.387 mm Hg) inside the Magna Ease, whereas the lowest EOA (1.335 cm2) and the highest MPG (11.876 mm Hg) were shown inside the Hancock II. Additionally, the highest GOAmax and the lowest PWImean of the THV were noticed inside the Magna Ease. The THV showed lower GOAmax and higher PWImean inside the Trifecta when placed in a deeper position. CONCLUSION: Deep implantation of the SAPIEN 3 Ultra inside the Trifecta correlates with impaired functional results. In contrast, the implantation position of the SAPIEN 3 Ultra inside the Magna Ease and the Hancock II did not have a significant effect on functional results.

4.
Sci Rep ; 14(1): 12212, 2024 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806571

RESUMO

A positive family history is a major independent risk factor for atherosclerosis, and genetic variation is an important aspect of cardiovascular disease research. We identified a heterozygous missense variant p.L245P in the MMP10 gene in two families with premature myocardial infarction using whole-exome sequencing. The aim of this study was to investigate the consequences of this variant using in-silico and functional in-vitro assays. Molecular dynamics simulations were used to analyze protein interactions, calculate free binding energy, and measure the volume of the substrate-binding cleft of MMP10-TIMP1 models. The p.L245P variant showed an altered protein surface, different intra- and intermolecular interactions of MMP10-TIMP1, a lower total free binding energy between MMP10-TIMP1, and a volume-minimized substrate-binding cleft of MMP10 compared to the wild-type. For the functional assays, human THP-1 cells were transfected with plasmids containing MMP10 cDNA carrying the p.L245P and wild-type variant and differentiated into macrophages. Macrophage adhesion and migration assays were then conducted, and pro-inflammatory chemokine levels were evaluated. The p.L245P variant led to macrophages that were more adherent, less migratory, and secreted higher levels of the pro-inflammatory chemokines CXCL1 and CXCL8 than wild-type macrophages. Thus, the p.L245P variant in MMP10 may influence the pathogenesis of atherosclerosis in families with premature myocardial infarction by altering protein - protein interactions, macrophage adhesion and migration, and expression of pro-inflammatory chemokines, which may increase plaque rupture. These results could contribute to the development of selective MMP10 inhibitors and reduce the risk of atherosclerosis in families with a history of premature myocardial infarction.


Assuntos
Metaloproteinase 10 da Matriz , Mutação de Sentido Incorreto , Infarto do Miocárdio , Humanos , Infarto do Miocárdio/genética , Metaloproteinase 10 da Matriz/genética , Metaloproteinase 10 da Matriz/metabolismo , Masculino , Feminino , Linhagem , Adulto , Simulação de Dinâmica Molecular , Macrófagos/metabolismo , Células THP-1 , Pessoa de Meia-Idade , Sequenciamento do Exoma , Movimento Celular/genética , Predisposição Genética para Doença , Adesão Celular/genética , Inibidor Tecidual de Metaloproteinase-1
5.
Health Sci Rep ; 7(8): e2304, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39166121

RESUMO

Background and Aims: The durability of surgical aortic valve bioprostheses (SAV) is limited by the calcification of the leaflets, which results in degeneration. In clinical routine, there seems to be substantial variability in the degeneration of specific SAV models. Our study aims to establish an in vitro calcification model for prosthetic valves, characterizing the calcification behavior of different SAVs. Methods: Five commercially available SAV models (Epic™ Supra, Freestyle®, Intuity®, Perimount®, and Trifecta™) were perfused with double-distilled water and physiological buffer with a defined calcium concentration (CaCl2 = 1.5 mM) at 37°C over 32.9 million cycles in a Hi-Cycle tester which corresponds to approximately 1 patient-year (calcified group). Untreated prosthetic valves served as the negative control group (noncalcified group). Calcium titration, scanning electron microscopy (SEM), histological examination, and tissue thickness measurements were performed to evaluate noncalcified and calcified SAVs (n = 10). Results: Treatment in the Hi-Cycle tester with calcification buffer maintained significantly higher calcium absorption of SAVs compared to the control group (p < 0.001). Additionally, hydroxyapatite crystals were found in the calcified SAV in SEM. Porcine valves rarely demonstrated punctual calcification pattern, while bovine pericardial valves presented distinct planar calcification pattern in histological examination. Further, calcification content differed significantly depending on the SAV model, with the highest calcium content in Trifecta (213 µg/cm2) and the lowest in Epic Supra (8 µg/cm2) (p < 0.001). Conclusion: Data from our study revealed significant differences in leaflet calcification for the various aortic valve bioprostheses models. Further studies are necessary to investigate whether these findings can mimic the clinical data of the implanted prostheses.

6.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38479833

RESUMO

OBJECTIVES: The Ross procedure represents an excellent treatment option in younger patients with aortic stenosis but is limited by poor availability of homografts. In this study, we investigated the hydrodynamic performance of 3 different types of right ventricular outflow tract replacement with pericardium or synthetic material. METHODS: Three different types of valved conduits were constructed using pericardium and/or synthetic material (Group PEPE: pericardial cusps and pericardial conduit, Group PEPR: pericardial cusps and Dacron conduit, Group PRPR: expanded polytetrafluoroethylene cusps and Dacron conduit). The conduits were designed according to the Ozaki method. Their hydrodynamic performance (effective orifice area, mean pressure gradient and leakage volume) were evaluated in a mock circulation loop at different hydrodynamic conditions. RESULTS: Hydrodynamic assessment showed significantly larger effective orifice area of PEPE and PEPR compared to PRPR under all conditions and there were no significant differences between PEPE and PEPR [for condition 2: PEPE 2.43 (2.35-2.54) cm2, PEPR: 2.42 (2.4-2.5) cm2, PRPR: 2.08 (1.97-2.21) cm2, adjusted pairwise comparisons: PEPE versus PEPR: P = 0.80, PEPE versus PRPR: P < 0.001, PEPR versus PRPR: P < 0.001]. Mean pressure gradient was significantly lower for PEPE and PEPR compared with PRPR, whereas no significant differences were seen between PEPE and PEPR. Leakage volume was significantly lower for PEPE and PEPR compared with PRPR under all conditions while leakage was similar between PEPE and PEPR. CONCLUSIONS: Pulmonary graft reconstruction with pericardium cusps showed superior hydrodynamic performance compared with polytetrafluoroethylene cusps. Our results suggest that it could be considered as an alternative substitute for right ventricular outflow tract replacement during the Ross procedure.


Assuntos
Próteses Valvulares Cardíacas , Obstrução do Fluxo Ventricular Externo , Humanos , Polietilenotereftalatos , Prótese Vascular , Desenho de Prótese , Obstrução do Fluxo Ventricular Externo/cirurgia , Politetrafluoretileno , Resultado do Tratamento , Estudos Retrospectivos
7.
Clin Res Cardiol ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38436739

RESUMO

BACKGROUND: In patients not suitable for transfemoral transcatheter aortic valve implantation (TAVI), several access strategies can be chosen. AIM: To evaluate the use and patient outcomes of transaxillary (TAx), transapical (TA), and transaortic (TAo) as alternative access for TAVI in Germany; to further evaluate surgical cutdown vs. percutaneous TAx access. METHODS: All patients entered the German Aortic Valve Registry (GARY) between 2011 and 2019 who underwent non-transfemoral TAVI were included in this analysis. Patients with TA, TAo, or TAx TAVI were compared using a weighted propensity score model. Furthermore, a subgroup analysis was performed for TAx regarding the percutaneous or surgical cutdown approach. RESULTS: Overall, 9686 patients received a non-transfemoral access. A total of 8918 patients (92.1%) underwent TA, 398 (4.1%) TAo, and 370 (3.8%) TAx approaches. Within the TAx subgroup, 141 patients (38.1%) received subclavian cutdown, while 200 (54.1%) underwent a percutaneous approach. The TA patients had a significantly lower 30-day survival than TAx patients (TA 90.92% vs. TAx 95.59%, p = 0.006; TAo 92.22% vs. TAx 95.59%, p = 0.102). Comparing percutaneous and cutdown TAx approaches, no significant differences were seen. However, more vascular complications occurred (TA 1.8%, TAo 2.4%, TAx 12.2%; p < .001), and the hospital length of stay was shorter (TA 12.9 days, TAo 14.1 days, TAx 12 days; p < .001) after TAx access. CONCLUSION: It may be reasonable to consider TAx access first in patients not suitable for TF-TAVI, because the 30-day survival was higher compared with TA access and the 1-year survival was higher compared with TAo access. It remains important for the heart teams to offer alternative access modalities for patients not amenable to the standard TF-TAVI approaches.

8.
Artigo em Inglês | MEDLINE | ID: mdl-39115488

RESUMO

The "International Society for Heart and Lung Transplantation Guidelines for the Evaluation and Care of Cardiac Transplant Candidates-2024" updates and replaces the "Listing Criteria for Heart Transplantation: International Society for Heart and Lung Transplantation Guidelines for the Care of Cardiac Transplant Candidates-2006" and the "2016 International Society for Heart Lung Transplantation Listing Criteria for Heart Transplantation: A 10-year Update." The document aims to provide tools to help integrate the numerous variables involved in evaluating patients for transplantation, emphasizing updating the collaborative treatment while waiting for a transplant. There have been significant practice-changing developments in the care of heart transplant recipients since the publication of the International Society for Heart and Lung Transplantation (ISHLT) guidelines in 2006 and the 10-year update in 2016. The changes pertain to 3 aspects of heart transplantation: (1) patient selection criteria, (2) care of selected patient populations, and (3) durable mechanical support. To address these issues, 3 task forces were assembled. Each task force was cochaired by a pediatric heart transplant physician with the specific mandate to highlight issues unique to the pediatric heart transplant population and ensure their adequate representation. This guideline was harmonized with other ISHLT guidelines published through November 2023. The 2024 ISHLT guidelines for the evaluation and care of cardiac transplant candidates provide recommendations based on contemporary scientific evidence and patient management flow diagrams. The American College of Cardiology and American Heart Association modular knowledge chunk format has been implemented, allowing guideline information to be grouped into discrete packages (or modules) of information on a disease-specific topic or management issue. Aiming to improve the quality of care for heart transplant candidates, the recommendations present an evidence-based approach.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA