Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Infection ; 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39177882

RESUMO

PURPOSE: The consequent use of malaria rapid diagnostic tests (RDTs) preceding a treatment decision has improved the global management of malaria. A combination RDT, including an inflammation marker to potentially guide antibiotic prescription, could improve the management of acute febrile illness (AFI). METHODS: We performed a prospective, cross-sectional study in Gabon evaluating the STANDARD Malaria/CRP DUO (S-DUO) RDT. Participants aged 2 to 17 years with fever at presentation and/or a history of fever < 7 days were enrolled. Expert microscopy, SD Bioline Malaria Ag P.f/Pan test for malaria detection, and NycoCard CRP device for CRP were used as comparators. AFI cases were classified on a spectrum encompassing bacterial vs. non-bacterial infection. RESULTS: 415 participants with AFI were enrolled. S-DUO RDT sensitivity and specificity for malaria detection vs. microscopy were 99·1% (95·2-100%) and 72·7% (64·3-80·1%); and for CRP detection (20 mg/L and above) 86·9% (80-92%) and 87% (79·2-92·7%), respectively. The difference in CRP levels between bacterial infection (mean = 41·2 mg/L) and other causes of fever, measured from our study population using the Nycocard device, was statistically significant (p < 0·01); CRP precision-recall AUC to distinguish bacterial infection class vs. non-bacterial classifications was 0·79. CONCLUSION: S-DUO RDT is suitable for malaria detection in moderate-to-high malaria transmission settings such as in Lambaréné; however, a CRP band detection limit > 40 mg/L is more adequate for indication of antibiotic prescription for AFI cases in Gabon.

2.
Viruses ; 16(7)2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-39066237

RESUMO

In response to the 2015 Zika virus (ZIKV) epidemic that occurred in Brazil, numerous commercial serological assays have been developed for clinical and research applications. Diagnosis of recent infection in pregnant women remains challenging. Having standardized, comparative studies of ZIKV tests is important for implementing optimal diagnostic testing and disease surveillance. This is especially important for serology tests used to detect ZIKV infection given that antibodies against ZIKV can cross-react with other arboviruses in the same virus family, such as dengue virus (DENV), yellow fever virus (YFV) and West Nile virus (WNV). We looked at the sensitivity and specificity of tests detecting ZIKV antibodies (IgM, IgG) from multiple manufacturers using panels of samples previously collected with known exposure to ZIKV and other arboviruses. We found that performance of the IgM tests was highly variable, with only one test (Inbios 2.0 IgM capture ELISA) having both high sensitivity and specificity. All IgG tests showed good sensitivity; however, specificity was highly variable, with some assays giving false-positive results on samples infected by another flavivirus. Overall, the results confirmed that accurate ZIKV antibody testing is challenging, especially in specimens from regions endemic for multiple other flaviviruses, and highlight the importance of available and suitable reference samples to evaluate ZIKV diagnostics.


Assuntos
Anticorpos Antivirais , Imunoglobulina G , Imunoglobulina M , Sensibilidade e Especificidade , Testes Sorológicos , Infecção por Zika virus , Zika virus , Humanos , Zika virus/imunologia , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/imunologia , Infecção por Zika virus/sangue , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Testes Sorológicos/métodos , Testes Sorológicos/normas , Imunoglobulina M/sangue , Imunoglobulina G/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Reações Cruzadas/imunologia , Feminino , Gravidez , Brasil
3.
Rev. Soc. Bras. Med. Trop ; 55: e0016, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1387550

RESUMO

ABSTRACT Background: The emergence of variants of concern (VOCs) requires an ongoing assessment of the performance of antigen lateral flow tests (Ag-RDTs). The limit of detection (LOD) of 32 Ag-RDTs was evaluated using the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Gamma variant. Methods: Ag-RDTs were performed according to the manufacturer's instructions with a clinical isolate of the Gamma variant. Results: Twenty-eight of the 32 Ag-RDTs exceeded the World Health Organization criteria. Conclusions: This comprehensive analytical evaluation of Ag-RDTs demonstrated that the test performance was maintained with Gamma VOC.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA